Film Capacitors - Power Factor Correction PhaseCap Compact capacitors Series/Type: Ordering code: MKK525-D-16.7-02 B25673A5162A720 Date: Version: January 2012 2 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the color to "white". This ensures that the table disappears (invisible) for the customer PDF. Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it! Identification/Classification 1 (header 1 + top left bar): Film Capacitors - Power Factor Correction Identification/Classification 2 (header 2 + bottom left header bar): PhaseCap Compact capacitors Ordering code: (top right header bar) B25673A5162A720 Series/Type: (top right header bar) MKK525-D-16.7-02 Preliminary data (optional): (if necessary) Department: FILM PFC PM Date: January 2012 Version: 2 EPCOS AG 2012. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Film Capacitors - Power Factor Correction PhaseCap Compact capacitors B25673A5162A720 MKK525-D-16.7-02 Construction Dielectric: Polypropylene film Non-PCB, semi-dry biodegradable resin Concentric winding Wave cut Extruded round aluminium can with stud Provided with ceramic discharge module Overpressure disconnector Features Three-phase, delta connected Self-healing technology Naturally air cooled (or forced air cooling) Indoor mounting Typical applications For Power Factor Correction Terminals Optimized capacitor safety terminals Mounting Threaded stud at bottom of can (max. torque for M12 = 10 Nm) FILM PFC PM Please read Cautions and warnings and Important notes at the end of this document. January 2012 Page 2 of 10 Film Capacitors - Power Factor Correction PhaseCap Compact capacitors B25673A5162A720 MKK525-D-16.7-02 Technical data and specifications Characteristics MKK525-D-16.7-02 Rated capacitance CN 3 * 64.3 F Tolerance -5 / +10% Connection D (Delta) Rated voltage VN 525 V AC rms Rated frequency fN 50 Hz 60 Hz Output 16.7 kvar 20.0 kvar Rated current IR 18 A 22 A tan 0 (dielectric) ~0.2 W / kvar WN 53 Ws RS 4.12 m Ris * C 30000 s *tan (50 Hz) 0.45 W / kvar * Without discharge resistor Maximum ratings Vmax (up to 8 h daily) 580 V AC rms / 820 V peak Vmax (up to 1 min) 680 V AC rms / 962 V peak Imax Up to 1.8 * IR (A) including combined effects of harmonics, overvoltages and capacitance tolerance* IS 400 * IR (A) VTC imp 8000 Vpk (Standard 1.2/50 s impulse) Care must be taken to ensure that the maximum permissible voltages and operating temperatures are not exceeded Test data VTT 1150 V AC / 50 Hz for 10 s VTC 3000 V AC / 50 Hz for 10 s Design data Dimensions (d x h) 116 x 200 mm Weight approx 2.2 kg Impregnation Non PCB, semi-dry biodegradable resin Fixing Threaded bolt M12 Max. torque (Al can stud) 10 Nm Mounting position Any mounting position possible. See "Maintenance and Installation Manual" for further details. FILM PFC PM Please read Cautions and warnings and Important notes at the end of this document. January 2012 Page 3 of 10 Film Capacitors - Power Factor Correction PhaseCap Compact capacitors B25673A5162A720 MKK525-D-16.7-02 Climatic category -40/60 min -40 C max 60 C Storage temperature -40 C....+85 C hotspot Max. 85 C Maximum power loss at ambient P max at ambient 7.5 W 55 C 5.0 W 65 C 2.5 W 75 C 0.0 W 85 C Humidity av. rel. < 95% Degree of protection IP 20 Maximum altitude 4,000 m * M ax. allo wable po wer lo ss at specific ambient Temp. B 25673A 5162A 720 M ax. allo wable current (rms) at specific ambient Temp. B 25673A 5162A 720 20 35 28 max 10 I P max 15 5 21 14 7 0 0 15 35 55 75 95 15 75 95 amb M ax. allo wable ambient Temp. at specific current (rms) B 25673A 5162A 720 90 90 75 75 amb 60 amb 55 amb M ax. allo wable ambient Temp. at specific po wer lo ss B 25673A 5162A 720 35 45 30 60 45 30 15 15 0 5 10 P 15 20 5 10 15 I max FILM PFC PM Please read Cautions and warnings and Important notes at the end of this document. 0 20 25 30 max January 2012 Page 4 of 10 Film Capacitors - Power Factor Correction PhaseCap Compact capacitors B25673A5162A720 MKK525-D-16.7-02 Mean life expectancy tLD Up to 200 000 hours (temperature class -40/C) ; HS 70C Up to 150 000 hours (temperature class -40/60) ; HS 70C Max. 10000 switchings per year Terminals Protection degree Isolated terminals, IP20 Max. torque 2.0 Nm Terminal cross section 25 mm2 Maximum terminal current 80 A Creepage distance (min) 12.7 mm Clearance (min) 9.6 mm Safety Mechanical safety Overpressure disconnector Max. short circuit current (AFC: 10 kA) Discharge resistor time 60 s to 75 V or less Reference standards IEC 60831-1/2, UL 810-5th edition FILM PFC PM Please read Cautions and warnings and Important notes at the end of this document. January 2012 Page 5 of 10 Film Capacitors - Power Factor Correction PhaseCap Compact capacitors Label design B25673A5162A720 MKK525-D-16.7-02 Dimensional drawing FILM PFC PM Please read Cautions and warnings and Important notes at the end of this document. January 2012 Page 6 of 10 Film Capacitors - Power Factor Correction PhaseCap Compact capacitors B25673A5162A720 MKK525-D-16.7-02 Cautions and warnings In case of dents of more than 1 mm depth or any other mechanical damage, capacitors must not be used at all. This applies also in cases of oil leakages. To ensure the full functionality of the overpressure disconnector, elastic elements must not be hindered and a minimum space of 12 mm has to be kept above each capacitor. Do not handle the capacitor before it is discharged. Resonance cases must be avoided by appropriate application design in any case. Handle capacitors carefully, because they may still be charged even after disconnection due to faulty discharging devices. Protect the capacitor properly against over current and short circuit. Failure to follow cautions may result, worst case, in premature failures, bursting and fire. Discharging Capacitors must be discharged to a maximum of 10% of rated voltage before they are switched in again. This prevents an electric impulse discharge in the application, influences the capacitor's service life and protects against electric shock. The capacitor must be discharged to 75 V or less within 3 minutes. There must be not any switch, fuse or any other disconnecting device in the circuit between the power capacitor and the discharging device. PhaseCap Compact-capacitors either have a pre-mounted ceramic discharge module inserted from above into the middle section of the terminal, or for high voltages/high loads a plastic discharge module mounted at one side of the terminal; alternatively discharge reactors are available from EPCOS. Discharge and short circuit capacitor before handling! Service life expectancy Electrical components do not have an unlimited service life expectancy; this applies to self-healing capacitors too. The maximum service life expectancy may vary depending on the application the capacitor is used in. Safety Electrical or mechanical misapplication of capacitors may be hazardous. Personal injury or property damage may result from bursting of the capacitor or from expulsion of oil or melted material due to mechanical disruption of the capacitor. Ensure good, effective grounding for capacitor enclosures. Provide means of disconnecting and insulating a faulty component/bank. The terminals of capacitors, connected bus bars and cables as well as other devices may also be energized. Follow good engineering practice. Thermal load/over-temperature After installation of the capacitor it is necessary to verify that maximum hot-spot temperature is not exceeded at extreme service conditions. FILM PFC PM Please read Cautions and warnings and Important notes at the end of this document. January 2012 Page 7 of 10 Film Capacitors - Power Factor Correction PhaseCap Compact capacitors B25673A5162A720 MKK525-D-16.7-02 Overpressure disconnector To ensure full functionality of an overpressure disconnector, the following must be observed: 1. The elastic elements must not be hindered, i.e. Connecting lines must be flexible leads (cables). There must be sufficient space (min. 12 mm) for expansion above the connections. This will enable a longitudinal extension of the can to secure the overpressure disconnector work. Folding beads must not be retained by clamps. 2. The maximum allowed fault current of 10000 A in accordance with UL 810 standard must be assured by the application. 3. Stress parameters of the capacitor must be within the IEC60831 specification. Overcurrent and short circuit protection Use HRC fuses or MCCBs for short circuit protection. Short circuit protection and connecting cables should be selected so that 1.5 times the rated capacitor current can be permanently handled. HRC fuses do not protect a capacitor against overload - they are only for short circuit protection. The HRC fuse rating should be 1.6 to 1.8 times rated capacitor current. Do not use HRC fuses to switch capacitors (risk of arcing). Use thermal magnetic over current relays for overload protection. Resonance cases Resonance cases must be avoided by appropriate application design in any case. Maximum total RMS capacitor current (incl. fundamental harmonic current) specified in technical data must not be exceeded. Re-switching vs. phase-opposition In case of voltage interruption, a sufficient discharge time has to be ensured to avoid phaseopposition and resulting high inrush currents. Vibration resistance The resistance to vibration of capacitors corresponds to IEC 68, part 2-6. Max. test conditions: Test duration 6 h* Frequency range 1 10 ... 55 Hz* Displacement amplitude 0.75 mm* *corresponding to max. 98.1 m/s or 10 g FILM PFC PM Please read Cautions and warnings and Important notes at the end of this document. January 2012 Page 8 of 10 Film Capacitors - Power Factor Correction PhaseCap Compact capacitors B25673A5162A720 MKK525-D-16.7-02 These figures apply to the capacitor alone. Because the fixing and the terminals may influence the vibration properties, it is necessary to check stability when a capacitor is built in and exposed to vibration. Irrespective of this, you are advised not to locate capacitors where vibration amplitude reaches the maximum in strongly vibrating equipment. Mechanical protection The capacitor has to be installed in a way that mechanical damages and dents in the aluminum can are avoided. Grounding The threaded bottom stud of the capacitor has to be used for grounding. In case grounding is done via metal chassis that the capacitor is mounted to, the layer of varnish beneath the washer and nut should be removed. The maximum tightening torque is 10 Nm. Maintenance Check tightness of the connections/terminals periodically. Take current reading twice a year and compare with nominal current. Use a harmonic analyser or true effective RMS-meter. In case of current above the nominal current check your application for modifications. If a significant increase in the amount of non-linear loads has been detected, then a consultant has to be called in for a harmonic study. In case of the presence of harmonics installation of a de-tuned capacitor bank (reactors) must be considered. Check the discharge resistors/reactors and in case of doubt, check their function: (1) Power the capacitor up and down. (2) After 90 seconds the voltage between the terminals must decline to less than 75 V. Check the temperature of capacitors directly after operation for a longer period, but make sure that the capacitors have been switched off. In case of excessive temperature of individual capacitors, it is recommended to replace these capacitors, as this should be an indication for loss factor increase, which is a sign for reaching end of life. Storage and operating conditions Do not use or store capacitors in corrosive atmosphere, especially where chloride gas, sulfide gas, acid, alkali, salt or the like are present. In dusty environments regular maintenance and cleaning especially of the terminals is required to avoid conductive path between phases and/or phases and ground. Note For detailed information about PFC capacitors and cautions, refer to the latest version of EPCOS PFC Product Profile. FILM PFC PM Please read Cautions and warnings and Important notes at the end of this document. January 2012 Page 9 of 10 Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap, DigiSiMic, DSSP, MiniBlue, MiniCell, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. Page 10 of 10