MB354CA
35 Amp Single Phase
Bridge Rectifier
400 Volts
MB-35
Features
•
Mounting Hole For #8 Screw
•
High Conductivity Metal Case
•
Any Mounting Position
•
Surge Rating Of 400 Amps
DIMENSIONS
Maximum Ratings
•
Operating Temperature: -55
°
C to +175
°
C
•
Storage Temperature: -55
°
C to +175
°
C
MCC
Catalog
Number
Device
Marking
Maximum
Reccurrent
Peak Reverse
Voltage
Maximum
Avalanche
Blockdown
Maximum
Avalanche
Blockdown
Voltage
V
RRM
(V) V
BR
(V)
V
BR
(V)
Electrical Characteristics @ 25
°
C Unless Otherwise Specified
Average Forward
Current
I
F(AV)
35.0A
T
C
= 55
°
C
Peak Forward Surge
Current
I
FSM
400A
8.3ms, half sine
Maximum Forward
Voltage Drop Per
Element
V
F
1.2V
I
FM
= 17.5A per
element;
T
J
= 25
°
C
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
I
R
10
µ
A
1.0mA
T
J
= 25
°
C
T
J
= 100
°
C
*Pulse test: Pulse width 300
µ
sec, Duty cycle 1%
B
C
E
AC
+
-
A
AC
G
H
A
D
J
www
.
mccsemi
.com
Voltage
MB354CA
MB354CA
400V
450V
900V
INCHES
MM
DIM
MIN
MAX
MIN
MAX
NOTE
A
1.115
1.135
28.33
28.83
B
.427
.447
10.85
11.35
C
.428
.468
10.87 11.89
D
.688
.730
17.48
18.50
E
.618
.658
15.70 16.71
G
.193
---
4.90
---
∅
H
.618
.658
15.70
16.71
J
.530
.570
13.46
14.48
omp
onents
21201 Itasca Street Chatsworth
!
"
#
$
%
!
"
#
MCC
MB35
4
CA
Instantaneous Reverse Leakage Current - MicroAmperes
versus
Percent Of Rated Peak Reverse Voltage - Volts
Average Forward Rectified Current - Amperes
versus
Case Temperature -
°
C
Figure 3
Forward Derating Curve
25
50
100
150
175
0
0
10
20
30
Single Phase, Half Wave
60Hz Resistive or Inductive Load
Amps
°
C
75
40
50
60
Instantaneous Forward Current - Amperes
versus
Instantaneous Forward Voltage - Volts
Figure 1
Typical Forward Characteristics
Volts
4
6
20
10
Amps
.2
1.2
.4
.6
.8
1.0
.01
.02
.04
.06
.1
.2
.4
.6
1
2
25
°
C
40
60
100
1.4
Figure 2
Typical Reverse Characteristics
Volts
.4
.6
2
1
µ
Amps
20
120
40
60
80
100
.001
.002
.00
4
.006
.01
.02
.04
.06
.1
.2
4
6
10
140
T
J
=25
°
C
1
100
4
0
100
200
300
8
Figure 4
Peak Forward Surge Current
Peak Forward Surge Current - Amperes
versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2
6
10
20
60
80
40
00
400
500
600
www
.
mccsemi
.com
MCC
Suppliers Inquiry
Previous
Next
Link
Name *
Reason for Contact
General Inquiry
Place Order
Report Issue
Target Price (Option)
Email Address *
Message *
BOM / Attach Files (Option)
Maximum allowed file size is 10MB