Features
■ Balanced Mini-TRIGARD™
■ 5 mm diameter, 7.5 mm long
■ UL Recognized
■ RoHS compliant* versions available
Applications
■ Telecommunications
■ Industrial electronics
■ Commercial electronics
■ Consumer electronics
■ Automotive, aircraft, military electronics
Characteristics
2036 Series - Miniature 3-Pole Gas Discharge Tube
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifi cations are subject to change without notice.
Customers should verify actual device performance in their specifi c applications.
Test Methods per ITU-T (CCITT) K.12, IEEE C62.31
Characteristic Model No.
2036-07 2036-09 2036-15 2036-20 2036-23 2036-25
DC Sparkover ±20 % @ 100 V/s 75 V 90 V 150 V 200 V 230 V 250V
Impulse Sparkover
100 V/µs
1000 V/µs
250 V
525 V
250 V
550 V
350 V
500 V
425 V
575 V
450 V
600 V
475 V
625 V
Impulse Transverse Delay ..................100 V/µs ................................................................................. < 75 ns
Insulation Resistance .........................100 V (50 V for Model 2036–07 & 2036-09) ........................... > 1010 Ω
Glow Voltage ......................................10 mA ..................................................................................... ~ 70 V
Arc Voltage .........................................1 A .......................................................................................... ~ 10 V
Glow-Arc Transition Current ............................................................................................................... < 0.5 A
Capacitance........................................1 MHz ..................................................................................... < 2 pF
DC Holdover Voltage1 .......................135 V, (52 V for Model 2036-07 & 2036-09, ........................... < 150 ms
80 V for Model 2036-15)
Impulse Discharge Current .................20000 A, 8/20 µs2 ................................................................... 1 operation minimum
10000 A, 8/20 µs .................................................................... > 10 operations
2000 A, 10/350 µs .................................................................. 1 operation
200 A, 10/1000 µs ................................................................. > 300 operations
200 A, 10/700 µs ................................................................... > 500 operations
Alternating Discharge Current ............20 Arms, 1 s2 .......................................................................... 1 operation minimum
10 Arms, 1 s ........................................................................... > 10 operations
Operating Temperature ....................................................................................................................... -55 to +85 °C
Climatic Category (IEC 60068-1)........................................................................................................ 40/90/21
Optional Switch-Grade Fail-Short device available.
Notes:
• UL recognized component, UL File E153537.
• No model number marking on tube; date code and voltage only: month year digits, xxxV (e.g. 0209 400V).
• The rated discharge current for Mini-TRIGARD™ Gas Discharge Tubes is the total current equally divided between each line to
ground.
• Sparkover limits after life ±25 %, IR >108Ω (-25 %,+30 % for Model 2036-07, 2036-09 and 2036-60).
• Operating characteristics per RUS PE-80 and Telcordia GR 1361 available, contact factory.
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
• At delivery AQL 0.65 Level II, DIN ISO 2859.
1 Network applied.
2 DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.
Characteristic Model No.
2036-30 2036-35 2036-40 2036-42 2036-47 2036-60
DC Sparkover ±20 % @ 100 V/s 300 V 350 V 400 V 420 V 470 V 600 V
Impulse Sparkover
100 V/µs
1000 V/µs
500 V
650 V
600 V
750 V
650 V
825 V
675 V
850 V
750 V
950 V
850 V
1100 V
*RoHS COMPLIANT
VERSIONS
AVAILABLE