SARA-G3 series Dual and quad-band GSM/GPRS modules Data Sheet Abstract Technical data sheet describing SARA-G3 series GSM/GPRS cellular modules. These modules are complete and cost efficient solutions offering two-band or quad-band GSM/GPRS voice and/or data transmission technology in a compact form factor. www.u-blox.com UBX-13000993 - R21 SARA-G3 series - Data Sheet Document Information Title SARA-G3 series Subtitle Dual and quad-band GSM/GPRS modules Document type Data Sheet Document number UBX-13000993 Revision and date R21 27-Mar-2018 Disclosure restriction Product Status Corresponding content status Functional Sample Draft For functional testing. Revised and supplementary data will be published later. In Development / Prototype Objective Specification Target values. Revised and supplementary data will be published later. Engineering Sample Advance Information Data based on early testing. Revised and supplementary data will be published later. Initial Production Early Prod. Information Data from product verification. Revised and supplementary data may be published later. Mass Production / End of Life Production Information Final product specification. This document applies to the following products: Product name Type number Modem version Application version PCN reference Product status SARA-G300 SARA-G300-00S-01 08.58 A01.01 UBX-16010060 Mass Production SARA-G310 SARA-G310-00S-01 08.58 A01.01 UBX-16010060 Mass Production SARA-G340 SARA-G340-00S-00 08.49 N.A. UBX-14000382 End of Life SARA-G340-01S-00 08.70 A00.02 UBX-14039634 End of Life SARA-G340-02S-00 08.90 A00.02 UBX-16001074 End of Life SARA-G340-02S-01 08.90 A01.13 UBX-18008871 Mass Production SARA-G340-02X-00 08.90 A00.02 UBX-16017766 End of Life SARA-G340-02X-01 08.90 A01.13 UBX-18008871 Mass Production SARA-G350-00S-00 08.49 N.A. GSM.G2-TN-13002 End of Life SARA-G350-01S-00 08.70 A00.02 UBX-14039634 End of Life SARA-G350-01B-00 08.70 A00.02 UBX-14039634 End of Life SARA-G350-02S-00 08.90 A00.02 UBX-16001074 End of Life SARA-G350-02S-01 08.90 A01.13 UBX-18008871 Mass Production SARA-G350-00X-00 08.49 N.A. GSM.G2-TN-13002 End of Life SARA-G350-02X-00 08.90 A00.02 UBX-17048555 End of Life SARA-G350-02X-01 08.90 A01.13 UBX-18008871 Mass Production SARA-G340 ATEX SARA-G350 SARA-G350 ATEX u-blox or third parties may hold intellectual property rights in the products, names, logos and designs included in this document. Copying, reproduction, modification or disclosure to third parties of this document or any part thereof is only permitted with the express written permission of u-blox. The information contained herein is provided "as is" and u-blox assumes no liability for its use. No warranty, either express or implied, is given, including but not limited to, with respect to the accuracy, correctness, reliability and fitness for a particular purpose of the information. This document may be revised by u-blox at any time without notice. For the most recent documents, visit www.u-blox.com. Copyright (c) u-blox AG. UBX-13000993 - R21 Page 2 of 49 SARA-G3 series - Data Sheet Contents Document Information ................................................................................................................................ 2 Contents .......................................................................................................................................................... 3 1 2 Functional description ......................................................................................................................... 5 1.1 Overview ........................................................................................................................................................ 5 1.2 Product features ......................................................................................................................................... 5 1.3 Block diagram .............................................................................................................................................. 6 1.4 Product description .................................................................................................................................... 7 1.5 AT command support ................................................................................................................................ 8 1.6 Supported features .................................................................................................................................... 8 Interfaces ............................................................................................................................................... 12 2.1 Power management ..................................................................................................................................12 2.1.1 Module supply input (VCC) ..............................................................................................................12 2.1.2 RTC supply input/output (V_BCKP) ...............................................................................................12 2.1.3 Digital I/O interfaces supply output (V_INT) ................................................................................12 2.2 Antenna........................................................................................................................................................12 2.2.1 Antenna RF interface (ANT) ............................................................................................................12 2.2.2 Antenna detection (ANT_DET) .......................................................................................................12 2.3 System functions ...................................................................................................................................... 13 2.3.1 Module power-on (PWR_ON) .......................................................................................................... 13 2.3.2 Module power-off .............................................................................................................................. 13 2.3.3 Module reset (RESET_N) ................................................................................................................. 13 2.3.4 External 32 kHz signal input (EXT32K) ........................................................................................ 13 2.3.5 Internal 32 kHz signal output (32K_OUT) .................................................................................... 14 2.4 SIM ............................................................................................................................................................... 14 2.4.1 (U)SIM interface ................................................................................................................................ 14 2.4.2 SIM card detection (SIM_DET) ....................................................................................................... 14 2.5 Serial interfaces ........................................................................................................................................ 14 2.5.1 Asynchronous serial interface (UART) ......................................................................................... 15 2.5.2 Auxiliary asynchronous serial interface (AUX UART) ................................................................ 16 2.5.3 DDC (I2C compatible) interface ...................................................................................................... 16 2.6 Audio ............................................................................................................................................................. 17 2.7 GPIO .............................................................................................................................................................. 17 3 Pin definition ......................................................................................................................................... 18 3.1 4 Pin assignment .......................................................................................................................................... 18 Electrical specifications ................................................................................................................... 23 4.1 Absolute maximum rating....................................................................................................................... 23 4.1.1 Maximum ESD ................................................................................................................................... 23 4.2 Operating conditions ................................................................................................................................ 24 4.2.1 Operating temperature range ........................................................................................................ 24 4.2.2 Module thermal resistance ............................................................................................................. 24 4.2.3 Supply/Power pins ............................................................................................................................ 25 4.2.4 Current consumption ....................................................................................................................... 25 UBX-13000993 - R21 Page 3 of 49 SARA-G3 series - Data Sheet 4.2.5 RF performance ................................................................................................................................ 27 4.2.6 ANT_DET pin...................................................................................................................................... 27 4.2.7 PWR_ON pin ....................................................................................................................................... 28 4.2.8 RESET_N pin ...................................................................................................................................... 28 4.2.9 EXT32K pin ......................................................................................................................................... 28 4.2.10 SIM pins .............................................................................................................................................. 29 4.2.11 Generic Digital Interfaces pins ....................................................................................................... 29 4.2.12 DDC (I2C) pins..................................................................................................................................... 32 4.2.13 Audio pins ........................................................................................................................................... 32 5 Mechanical specifications ............................................................................................................... 34 6 Qualification and approvals............................................................................................................. 35 6.1 Reliability tests ..........................................................................................................................................35 6.2 Approvals ....................................................................................................................................................35 7 6.2.1 SARA-G3 series .................................................................................................................................35 6.2.2 SARA-G340 ATEX and SARA-G350 ATEX .................................................................................. 36 Product handling ................................................................................................................................. 38 7.1 Packaging ...................................................................................................................................................38 7.1.1 Reels ....................................................................................................................................................38 7.1.2 Tapes ................................................................................................................................................... 39 7.2 Moisture sensitivity levels ....................................................................................................................... 39 7.3 Reflow soldering ........................................................................................................................................40 7.4 ESD precautions ........................................................................................................................................40 8 Default settings ................................................................................................................................... 41 9 Labeling and ordering information ............................................................................................... 42 9.1 Product labeling......................................................................................................................................... 42 9.2 Explanation of codes ................................................................................................................................ 43 9.3 Ordering information ................................................................................................................................ 44 Appendix ....................................................................................................................................................... 45 Related documents ....................................................................................................................................47 Revision history .......................................................................................................................................... 48 Contact .......................................................................................................................................................... 49 UBX-13000993 - R21 Page 4 of 49 SARA-G3 series - Data Sheet 1 Functional description 1.1 Overview SARA-G3 series modules are versatile 2.5G GSM/GPRS cellular modules in a miniature LGA (Land Grid Array) form factor. Featuring low power consumption, the SARA-G3 series combines baseband, RF transceiver, power management unit, and power amplifier in a single, easy-to-integrate solution. SARA-G3 modules provide a fully qualified and certified solution, reducing cost and enabling short time to market. These modules are ideally suited for M2M applications such as: Automatic Meter Reading (AMR), Remote Monitoring Automation and Control (RMAC), surveillance and security, eCall, road pricing, asset tracking, fleet management, anti-theft systems and Point of Sales (PoS) terminals. SARA-G340 (dual-band) and SARA-G350 (quad-band) are full feature GSM/GPRS cellular modules with a comprehensive feature set including an extensive set of internet protocols. The modules also provide fully integrated access to u-blox GNSS positioning chips and modules, with embedded AGPS (AssistNow Online and AssistNow Offline) functionality. Any host processor connected to the cellular module through a single serial port can control both the cellular module and the positioning chip / module. SARA-G310 (quad-band) and SARA-G300 (dual-band) are GSM/GPRS cellular modules targeted for high volume cost-sensitive applications, providing GSM/GPRS functionalities with a reduced set of additional features to minimize the customer's total cost of ownership. The SARA-G3 series' compact form factor and LGA pads allow fully automated assembly with standard pick & place and reflow soldering equipment for cost-efficient, high-volume production. Product features SARA-G300 * SARA-G310 * * * * * 2 * * SARA-G340 * * * * * 2 4 * * * * * * * * * * * * * * * * 2 4 * * * * * * * * * * * SARA-G350 * * * * * 2 4 * * * * * * * * * * * SARA-G350 ATEX * * * * * 2 4 * * * * * * * * * * * Automotive Professional Standard 2 SARA-G340 ATEX = supported by all product versions = supported by product versions "01" onwards ATEX certification Low power idle-mode eCall / ERA-GLONASS Grade FW update via serial interface Dual stack IPv4/IPv6 Embedded SSL Embedded FTP, HTTP, SMTP Embedded TCP/UDP stack Jamming detection Antenna supervisor Features Network indication Digital Audio Analog Audio Audio DDC for u-blox GNSS receivers GPIO USB 2.0 SPI UART Interfaces CellLocate(R) AssistNow Software GNSS via modem Positioning GNSS receiver Bands GSM/GPRS 2-band 900/1800 Data Rate GPRS multi-slot class 10 Module GSM/GPRS 4-band 1.2 * * * * * * = 32 kHz signal at EXT32K input is required for low power idle-mode = supported by product versions "02" onwards Table 1: SARA-G3 series - summary of modules' main features1 SARA-G340 ATEX and SARA-G350 ATEX modules provide the same feature set as the SARA-G340 and SARA-G350 modules respectively, with the additional certification for use in potentially explosive atmospheres. Unless otherwise specified, SARAG340 refers to all SARA-G340 ATEX and SARA-G340 modules; in the same way SARA-G350 refers to both SARA-G350 ATEX and SARA-G350 modules. 1 UBX-13000993 - R21 Functional description Page 5 of 49 SARA-G3 series - Data Sheet 1.3 Block diagram 26 MHz 32 kHz 32 kHz PA ANT Power-On SAW Filter Switch RF Transceiver Reset SIM card UART Memory Auxiliary UART Baseband VCC (Supply) V_BCKP (RTC) Power Management V_INT (I/O) Figure 1: SARA-G300 and SARA-G310 block diagram 32.768 kHz 26 MHz PA ANT Power-On SAW Filter Switch RF Transceiver Reset SIM card SIM card detection UART Memory Auxiliary UART Baseband VCC (Supply) V_BCKP (RTC) DDC (for GPS/GNSS) Analog Audio Digital Audio Power Management GPIO V_INT (I/O) Antenna detection Figure 2: SARA-G340 and SARA-G350 block diagram UBX-13000993 - R21 Functional description Page 6 of 49 SARA-G3 series - Data Sheet 1.4 Product description Item SARA-G300 SARA-G310 SARA-G340 SARA-G350 GSM/GPRS Protocol Stack 3GPP Release 99 3GPP Release 99 3GPP Release 99 3GPP Release 99 Mobile Station Class Class B 2 Class B 2 Class B 2 Class B 2 GSM/GPRS Bands E-GSM 900 MHz DCS 1800 MHz GSM 850 MHz E-GSM 900 MHz DCS 1800 MHz PCS 1900 MHz E-GSM 900 MHz DCS 1800 MHz GSM 850 MHz E-GSM 900 MHz DCS 1800 MHz PCS 1900 MHz GSM/GPRS Power Class Class 4 (33 dBm) for 900 band Class 1 (30 dBm) for 1800 band Class 4 (33 dBm) for 850/900 bands Class 1 (30 dBm) for 1800/1900 bands Class 4 (33 dBm) for 900 band Class 1 (30 dBm) for 1800 band Class 4 (33 dBm) for 850/900 bands Class 1 (30 dBm) for 1800/1900 bands Packet Switched Data Rate GPRS multi-slot class 10 3 Coding scheme CS1-CS4 Up to 85.6 kb/s DL 4 Up to 42.8 kb/s UL 4 GPRS multi-slot class 10 3 Coding scheme CS1-CS4 Up to 85.6 kb/s DL 4 Up to 42.8 kb/s UL 4 GPRS multi-slot class 10 3 Coding scheme CS1-CS4 Up to 85.6 kb/s DL 4 Up to 42.8 kb/s UL 4 GPRS multi-slot class 10 3 Coding scheme CS1-CS 4 Up to 85.6 kb/s DL 4 Up to 42.8 kb/s UL 4 Circuit Switched Data Rate Up to 9.6 kb/s DL/UL 4 Transparent mode Non-transparent mode Up to 9.6 kb/s DL/UL 4 Transparent mode Non-transparent mode Up to 9.6 kb/s DL/UL 4 Transparent mode Non-transparent mode Up to 9.6 kb/s DL/UL 4 Transparent mode Non-transparent mode Network Operation Modes I to III I to III I to III I to III Table 2: SARA-G3 series GSM/GPRS characteristics summary The network automatically configures the channel encoding used by the module, depending on conditions and the quality of the radio link between cell phone and base station. If the channel is very noisy, the network may use the most robust coding scheme (CS-1) to ensure higher reliability. If the channel provides good conditions, the network can use the least robust but fastest coding scheme (CS-4) to obtain optimum speed. 2 Device can be attached to both GPRS and GSM services (i.e. Packet Switch and Circuit Switch mode) using one service at a time. GPRS multi-slot class 10 implies a maximum of 4 slots in DL (reception) and 2 slots in UL (transmission) with 5 slots in total. 4 The maximum bit rate of the module depends on the current network settings. 3 UBX-13000993 - R21 Functional description Page 7 of 49 SARA-G3 series - Data Sheet Basic features Supplementary services Display of Called Number Call Hold/Resume (HOLD) 5 Short Message Service (SMS) 5 Text and PDU mode supported Indication of Call Progress Signals 5 Call Waiting (CW) 5 Mobile-Originating SMS (MO SMS) Country/PLMN Indication Call Forwarding (CFU, CFB, CFNRy, CFNRc) 5 Mobile-Terminating SMS (MT SMS) Country/PLMN Selection Call Barring (BAOC, BOIC, BOIC-exHC, BAIC, BIC_Roam) 5 SMS indication and acknowledgement International Access Function 5 Call Deflection (CD) 5 SMS Cell Broadcast (CBS) Service Indicator Explicit Call Transfer (ECT) 5 SMS during circuit-switched calls 5 TBD Multi-Party (MTPY) 5 SMS over CSD TBD Calling Line Identification Presentation (CLIP)5 SMS over PSD Subscription Identity Management Calling Line Identification Restriction (CLIR)5 SMS storage on SIM Service Provider Indication Connected Line Identification Presentation (CoLP) 5 SMS storage on module memory 5 TBD Abbreviated Dialing 5 Connected Line Identification Restriction (CoLR) 5 Fixed Number Dialing 5 Unstructured Supplementary Services Data (USSD) SMS Classes 0, 1, 2, 3 and classless TBD Emergency Calls Capabilities 5 Dual Tone Multi Frequency (DTMF) 5 Barring of Dialed Numbers 5 Advice of Charge Charging (AoCC, AoCI)5 SIM Application Toolkit Calling Name Presentation (CNAP) 5 5 ME-SIM lock Concatenated SMS Network Identify and Time Zone (NITZ) Table 3: SARA-G3 series mobile stations: basic features, supplementary services, and SMS service summary6 1.5 AT command support The module supports AT commands according to 3GPP standards: TS 27.007 [9], 27.005 [10], 27.010 [11], and the u-blox AT command extension. For the complete list of the supported AT commands and their syntax, see the document u-blox AT Commands Manual [1]. RIL (Radio Interface Layer) software for Android and Embedded Windows is available for SARA-G3 modules free of charge; see the Android RIL Production delivery [6] and the Windows Embedded RIL Production delivery [7] application notes for more information. 1.6 Supported features Table 4 describes the main features supported by SARA-G3 modules. For more details, see the SARA-G3 / SARA-U2 Series System Integration Manual [2] and the u-blox AT commands manual [1]. 5 6 Feature Module Description Network Indication SARA-G340 / SARA-G350 GPIO configured to indicate the network status: registered home network, registered roaming, voice or data call enabled, no service. The network indication feature can be enabled through a custom AT command (see the u-blox AT commands manual [1], +UGPIOC AT command). Supported only by SARA-G340 and SARA-G350 modules These functionalities are supported via AT commands (for more details see the u-blox AT Commands Manual [1]). UBX-13000993 - R21 Functional description Page 8 of 49 SARA-G3 series - Data Sheet Feature Module Description Antenna Detection SARA-G340 / SARA-G350 The ANT_DET pin provides antenna presence detection capability, evaluating the resistance from the ANT pin to GND by means of an external antenna detection circuit implemented on the application board. The antenna detection feature can be enabled through a custom AT command (see the u-blox AT commands manual [1], +UANTR AT command). Jamming detection SARA-G340 / SARA-G350 Detects "artificial" interference that obscures the operator's carriers providing access to the GSM service and reports the start and stop of such conditions to the application processor (AP). The AP can react appropriately, e.g. by switching off the radio transceiver to reduce power consumption and monitoring the environment at constant periods. The jamming detection feature can be enabled and configured through a custom AT command (see the u-blox AT commands manual [1], +UCD AT command). Jamming condition indication over GPIO 7 SARA-G340 / SARA-G350 The jamming condition can be reported by a GPIO of the module as enabled and configured through a custom AT commands (see the u-blox AT commands manual [1], +UCD and +UGPIOC AT commands). Second AT interface 7 SARA-G340 / SARA-G350 AT command mode available on both the UART and the Auxiliary UART interfaces. See the u-blox AT commands manual [1], +USIO AT command for further details regarding serial interfaces configuration selection. Embedded TCP/IP and UDP/IP SARA-G340 / SARA-G350 Embedded TCP/IP and UDP/IP stack including direct link mode for TCP and UDP sockets. The sockets can be configured in Direct Link mode to establish a transparent end-to-end communication with an already connected TCP or UDP socket via serial interface. FTP, FTPS 8 SARA-G340 / SARA-G350 File Transfer Protocol as well as Secure File Transfer Protocol (SSL encryption of FTP control channel) functionalities are supported via AT commands. HTTP, HTTPS 8 SARA-G340 / SARA-G350 Hyper-Text Transfer Protocol as well as Secure Hyper-Text Transfer Protocol (SSL encryption) functionalities are supported via AT commands. HEAD, GET, POST, DELETE and PUT operations are available. Up to 4 client contexts can be simultaneously used. Embedded TLS 1.2 7 SARA-G340 / SARA-G350 With the support of X.509 certificates, Embedded TLS 1.2 provides server and client authentication, data encryption, data signature and enables TCP/IP applications like HTTPS and FTPS to communicate over a secured and trusted connection. The feature can be configured and enabled by +USECMNG and +USECPRF AT commands. IPv4/IPv6 dual-stack 9 SARA-G340 / SARA-G350 Capability to move between IPv4 and dual stack network infrastructures. IPv4 and IPv6 addresses can be used. GPS/GNSS via Modem SARA-G340 / SARA-G350 Full access to u-blox positioning chips and modules is available through a dedicated DDC (I2C) interface. A single serial port from any host processor can control both the cellular module and the positioning chips / modules. For more details, see the GNSS Implementation Application Note [3]. AssistNow Software SARA-G340 / SARA-G350 Embedded AssistNow Online and AssistNow Offline clients to provide full developed to provide better GNSS performance and faster Time-to-First-Fix. The clients can be enabled / disabled with an AT command. CellLocate(R) SARA-G340 / SARA-G350 Enables the estimation of device position based on the parameters of the mobile network cells visible to the specific device based on the CellLocate(R) database: Normal scan: parameters of the visible home network cells are only sent Deep scan: parameters of all surrounding cells of all mobile operators are sent CellLocate(R) is implemented using a set of AT commands for CellLocate(R) service configuration and position request. Supported by "02" product versions onwards FTPS and HTTPS supported by "01" product versions onwards 9 Supported by "02" product versions onwards 7 8 UBX-13000993 - R21 Functional description Page 9 of 49 SARA-G3 series - Data Sheet Feature Module Description Hybrid Positioning SARA-G340 / SARA-G350 Provides the module's current position using a u-blox positioning chip or module or the estimated position from CellLocate(R), depending on which positioning method provides the best and fastest solution according to the user configuration. Hybrid positioning is implemented through a set of AT commands that allow the configuration and the position request. Firmware update Over AT commands (FOAT) All Firmware module upgrade over the UART interface using AT command. BIP 9 SARA-G340 / SARA-G350 Bearer Independent Protocol for Over-the-Air SIM provisioning. The data transfer to/from the SIM uses either an already active PDP context or a new PDP context established with the APN provided by the SIM card. In-Band modem SARA-G340 / SARA-G350 In-Band modem solution for eCall and ERA-GLONASS emergency call applications over cellular networks implemented according to the 3GPP TS 26.267 specification [12]. When activated, the in-vehicle eCall / ERA-GLONASS system (IVS) creates an emergency call carrying both voice and data (including vehicle position data) directly to the nearest Public Safety Answering Point (PSAP) to determine whether rescue services should be dispatched to the known position. DTMF decoder SARA-G340 / SARA-G350 During a voice call, the Dual-Tone Multi-Frequency detector analyses the RX speech (coming from remote party). The detected DTMF symbols can be output via related URC. For more details, see the +UDTMFD AT command. Automatic selection of authentication type 9 SARA-G340 / SARA-G350 Automatic selection of authentication type during PDP context activation. The module will sequentially try different authentication protocols (none/CHAP/PAP) until the authentication succeeds. The feature can be enabled through the +UPSD and +UAUTHREQ AT commands. Signal quality report for PS calls 9 SARA-G340 / SARA-G350 The quality of the GPRS UL and/or DL connection is returned by the AT+CSQ command. Network Friendly Mode 9 SARA-G340 / SARA-G350 When the Network Friendly Mode is enabled, the module reacts to service request denials by using time-spaced, randomized or delayed retry schemes according to GSMA IoT Device Connection Efficiency Guidelines [13]. The feature can be enabled through the +UNFM, +UNFMCONF, +URPM AT commands. Smart Temperature Supervisor SARA-G340 / SARA-G350 Constant monitoring of the module board temperature: Warning notification when the temperature approaches an upper or lower predefined threshold Shutdown notified and forced when the temperature value is outside the specified range (shutdown suspended in case of an emergency call in progress) The Smart Temperature Supervisor feature can be enabled or disabled through an AT command (see the u-blox AT commands manual [1], +USTS AT command) Power saving All The sensor measures board temperature inside the shields, which can differ from ambient temperature. The power saving configuration is by default disabled, but it can be configured using an AT command. When power saving is enabled, the module automatically enters the low power idle-mode whenever possible, reducing current consumption. During idle-mode, the module processor core runs with the RTC 32 kHz reference clock, which is generated by: The internal 32 kHz oscillator, in case of SARA-G340 and SARA-G350 modules The 32 kHz signal provided at the EXT32K input pin, in case of SARA-G300 and SARA-G310 modules For more details, see the SARA-G3 / SARA-U2 Series System Integration Manual [2] and the u-blox AT commands manual [1], +UPSV AT command. Table 4: SARA-G3 series' main supported features UBX-13000993 - R21 Functional description Page 10 of 49 SARA-G3 series - Data Sheet u-blox is extremely mindful of user privacy. When a position is sent to the CellLocate(R) server, u-blox is unable to track the SIM used or the specific device. UBX-13000993 - R21 Functional description Page 11 of 49 SARA-G3 series - Data Sheet 2 Interfaces 2.1 Power management 2.1.1 Module supply input (VCC) SARA-G3 modules must be supplied through the three VCC pins by a DC power supply. Voltages must be stable: during operation, the current drawn from VCC can vary by some order of magnitude, especially due to the surging consumption profile of the GSM system (described in the SARA-G3 / SARA-U2 Series System Integration Manual [2]). It is important that the system power supply circuit is able to support peak power. SARA-G3 modules product versions "02" onwards provide separate supply inputs over the three VCC pins: VCC pins #52 and #53 represent the supply input for the internal RF power amplifier, demanding most of the total current drawn of the module when RF transmission is enabled during a voice/data call VCC pin #51 represents the supply input for the internal baseband Power Management Unit and the internal transceiver, demanding minor part of the total current drawn of the module when RF transmission is enabled during a voice/data call 2.1.2 RTC supply input/output (V_BCKP) V_BCKP is the Real Time Clock (RTC) supply of SARA-G3 modules. When VCC voltage is within the valid operating range, the internal Power Management Unit (PMU) supplies the RTC and the same supply voltage is available on V_BCKP pin. If the VCC voltage is under the minimum operating limit (e.g. during not powered mode), the V_BCKP pin can externally supply the RTC. 2.1.3 Digital I/O interfaces supply output (V_INT) SARA-G3 modules provide an internally generated supply rail output for digital interfaces (V_INT). This can be used in place of an external discrete regulator to supply pull-up resistors on the DDC interface. This optimizes the bill of material for various applications, e.g. with u-blox positioning modules operating at 1.8 V. 2.2 Antenna 2.2.1 Antenna RF interface (ANT) The ANT pin has an impedance of 50 and provides the RF antenna interface of SARA-G3 modules. 2.2.2 Antenna detection (ANT_DET) The ANT_DET pin is an Analog to Digital Converter (ADC) input provided only by SARA-G340 and SARA-G350 modules to sense the antenna presence (as optional feature), evaluating the resistance from the ANT pin to GND by means of an external antenna detection circuit implemented on the application board. For more details, see the SARA-G3 / SARA-U2 Series System Integration Manual [2] and the u-blox AT Commands Manual [1], +UANTR. UBX-13000993 - R21 Interfaces Page 12 of 49 SARA-G3 series - Data Sheet 2.3 System functions 2.3.1 Module power-on (PWR_ON) SARA-G3 modules can be switched on in one of the following ways: Rising edge on the VCC pin to a valid voltage for module supply, i.e. applying module supply Low level on the PWR_ON input pin, i.e. forcing the pin (normally high with external pull-up) to a low level for a valid time period (see section 4.2.7). The PWR_ON pin requires an external pull-up resistor to set its value to logic high and may not be left floating RTC alarm, i.e. pre-programmed scheduled time (see the u-blox AT Commands Manual [1], AT+CALA) SARA-G300 and SARA-G310 cannot be switched on with RTC alarm. 2.3.2 Module power-off SARA-G3 modules can be properly switched off, with storage of current settings and network detach, by: AT+CPWROFF command An abrupt under-voltage shutdown occurs on SARA-G3 modules when the VCC supply drops below the extended operating range minimum limit, but in this case it is not possible to perform the storing of the current parameter settings in the module's non-volatile memory as well as the proper network detach. An over-temperature or an under-temperature shutdown occurs on SARA-G3 modules when the temperature measured within the cellular module reaches the dangerous area, if the optional Smart Temperature Supervisor feature is enabled and configured by the dedicated AT command. For more details, see the SARA-G3 / SARA-U2 Series System Integration Manual [2] and the u-blox AT commands manual [1], +USTS AT command. 2.3.3 Module reset (RESET_N) SARA-G3 modules can be properly reset (rebooted), with storage of current parameter settings in the module's non-volatile memory and proper network detach, in this way: AT+CFUN command (see the u-blox AT Commands Manual [1]). This causes an "internal" or "software" reset of the module. An abrupt "external" or "hardware" reset occurs when a low level is applied to the RESET_N pin, which is normally set high by an internal pull-up, for a valid time period (see section 4.2.8), but in this case it is not possible to perform the storing of the current parameter settings as well as the proper network detach. 2.3.4 External 32 kHz signal input (EXT32K) SARA-G300 and SARA-G310 provide the EXT32K input pin that must be fed by a proper 32 kHz signal to furnish the reference clock for the RTC, allowing very low power idle-mode and RTC functions support. See section 4.2.9 for detailed electrical specifications for the 32 kHz signal. SARA-G340 and SARA-G350 do not provide the EXT32K input pin. An internal 32 kHz oscillator automatically generates the reference clock for the RTC, allowing very low power idle-mode and RTC functions support. UBX-13000993 - R21 Interfaces Page 13 of 49 SARA-G3 series - Data Sheet 2.3.5 Internal 32 kHz signal output (32K_OUT) SARA-G300 and SARA-G310 provide the 32K_OUT output pin which gives a 32 kHz reference signal suitable only to feed the EXT32K input pin of SARA-G300 / SARA-G310 modules, furnishing the reference clock for the RTC, allowing low power idle-mode and RTC functions support with modules switched on. SARA-G340 and SARA-G350 do not provide the 32K_OUT output; there is no EXT32K input on these modules. 2.4 SIM 2.4.1 (U)SIM interface A (U)SIM card interface is available via the VSIM, SIM_IO, SIM_CLK, SIM_RST pins of SARA-G3 series modules: the high-speed SIM/ME interface is implemented as well as the automatic detection of the required SIM supporting voltage. Both 1.8 V and 3 V SIM types are supported: activation and deactivation with automatic voltage switch from 1.8 V to 3 V are implemented, according to ISO-IEC 7816-3 Specifications. The SIM driver supports the PPS procedure for baud-rate selection, according to the values proposed by the SIM Card. 2.4.2 SIM card detection (SIM_DET) Not supported by SARA-G300-00S and SARA-G310-00S modules. The SIM_DET pin of SARA-G3 modules is a digital input provided to sense the SIM card presence (as an optional feature), when it is properly connected to the mechanical switch of the SIM card holder (for more details, see the SARA-G3 / SARA-U2 Series System Integration Manual [2]). 2.5 Serial interfaces SARA-G3 modules provide the following serial communication interfaces: UART interface: 9-wire unbalanced 1.8 V asynchronous serial interface supporting AT command mode Data mode and Online command mode 10 MUX functionality, including dedicated GNSS tunneling virtual channel 11 FW upgrades by means of the FOAT feature Auxiliary UART interface: 3-wire unbalanced 1.8 V asynchronous serial interface supporting AT command mode 12 GNSS tunneling 12 FW upgrades by means of the u-blox EasyFlash tool Trace log capture (diagnostic purpose) DDC interface 13: I2C-bus compatible interface supporting Communication with u-blox GPS/GNSS positioning chips / modules See the u-blox AT Commands Manual [1] for the definition of the interface data mode and online command mode. GNSS tunneling is not supported by SARA-G300 and SARA-G310 modules. 12 AT command mode and GNSS tunneling are not supported over the Auxiliary UART of SARA-G3 modules product versions "00" and "01". 13 DDC I2C-bus compatible interface is not supported by SARA-G300 and SARA-G310 modules. 10 11 UBX-13000993 - R21 Interfaces Page 14 of 49 SARA-G3 series - Data Sheet 2.5.1 Asynchronous serial interface (UART) The UART interface is a 9-wire unbalanced 1.8 V asynchronous serial interface provided on all SARA-G3 modules for communication with an application processor, supporting: AT command mode Data mode and Online command mode 14 MUX functionality, including dedicated GNSS tunneling virtual channel 15 FW upgrades by means of the FOAT feature UART characteristics are: Complete serial port with RS-232 functionality conforming to the ITU-T V.24 Recommendation [8], with CMOS compatible signal levels (0 V for low data bit or ON state and 1.8 V for high data bit or OFF state) Data lines (RXD as output, TXD as input), hardware flow control lines (CTS as output, RTS as input), modem status and control lines (DTR as input, DSR as output, DCD as output, RI as output) are provided Hardware flow control (default value), software flow control, or none flow control are supported Power saving indication available on the hardware flow control output (CTS line): the line is driven to the OFF state when the module is not ready to accept data signals 2400, 4800, 9600, 19200, 38400, 57600, 115200 b/s baud rates are supported Auto baud rate detection (autobauding) is the default configuration Frame format can be: 8N1 (8 data bits, no parity, 1 stop bit), or 8N2 (8 data bits, no parity, 2 stop bits), or 8E1 (8 data bits, even parity, 1 stop bit), or 8O1 (8 data bits, odd parity, 1 stop bit), or 7E1 (7 data bits, even parity, 1 stop bit), or 7O1 (7 data bits, odd parity, 1 stop bit) Automatic frame recognition is supported: this feature is the default configuration and it is enabled in conjunction with the auto baud rate detection only Default frame configuration with fixed baud is 8N1 (8 data bits, no parity, 1 stop bit), 2.5.1.1 Multiplexer protocol SARA-G3 module has a software layer with MUX functionality, 3GPP TS 27.010 [11], available on the UART physical link. This is a data link protocol (layer 2 of OSI model) which uses HDLC-like framing and operates between the module (DCE) and the application processor (DTE), and allows a number of simultaneous sessions over the physical link (UART): the user can concurrently use AT command interface on one MUX channel and data communication on another MUX channel. SARA-G340 and SARA-G350 modules define the following virtual channels: Channel 0: control channel Channel 1 - 5: AT commands / data connection Channel 6: GNSS tunneling SARA-G300 and SARA-G310 modules define the following virtual channels: Channel 0: control channel Channel 1 - 2: AT commands / data connection For more details, see the Mux Implementation Application Note [4]. 14 15 See the u-blox AT Commands Manual [1] for the definition of the interface data mode and online command mode. GNSS tunneling is not supported by SARA-G300 and SARA-G310 modules. UBX-13000993 - R21 Interfaces Page 15 of 49 SARA-G3 series - Data Sheet 2.5.2 Auxiliary asynchronous serial interface (AUX UART) The auxiliary UART interface is a 3-wire unbalanced 1.8 V asynchronous serial interface available on all SARA-G3 modules, supporting 16 AT command mode 17 GNSS tunneling mode 17 FW upgrades by means of the u-blox EasyFlash tool Trace log capture (diagnostic purpose) Auxiliary UART characteristics are: 2.5.3 Only the RXD_AUX data output and the TXD_AUX data input are provided, with CMOS compatible signal levels (0 V for low data bit or ON state and 1.8 V for high data bit or OFF state) Characteristics in AT command mode 17: Baud rate can be: 2400, 4800, 9600, 19200, 38400, 57600, 115200 b/s, with default value 115200 b/s Frame format can be: 8N1, or 8N2, or 8E1, or 8O1, or 7E1, or 7O1, with default value 8N1 Automatic baud rate detection (autobauding) and automatic frame recognition are not supported Software flow control, or None flow control (default value) are supported Characteristics in GNSS tunneling mode 17: Baud rate is 115200 b/s Frame format is 8N1 (8 data bits, no parity, 1 stop bit) None flow control is supported Characteristics for FW upgrade and diagnostic trace modes: 115200, 230400, 460800, 921600 b/s baud rates are supported Frame format is 8N1 (8 data bits, no parity, 1 stop bit) None flow control is supported DDC (I2C compatible) interface SARA-G340 and SARA-G350 modules provide an I2C compatible DDC interface on the SCL and SDA pins exclusively for the communication with u-blox GNSS positioning chips / modules. 16 17 See the u-blox AT Commands Manual [1], +USIO AT command for further details regarding serial interfaces configuration selection. AT command mode and GNSS tunneling are not supported over the Auxiliary UART of SARA-G3 modules product versions "00" and "01". UBX-13000993 - R21 Interfaces Page 16 of 49 SARA-G3 series - Data Sheet 2.6 Audio SARA-G340 and SARA-G350 modules provide analog and digital audio interfaces: Analog audio input: Supply output for an external microphone (MIC_BIAS): the pin can provide the bias to an external microphone by means of a simple circuit implemented on the application board Local ground for the external microphone (MIC_GND): the pin can provide the reference for the differential analog audio input as sense ground line for the external microphone circuit Analog audio output: Differential analog audio input (MIC_P, MIC_N) shared for all the analog audio path modes: the pins can be connected to the output of an external analog audio device or can be connected to an external microphone by means of a simple circuit implemented on the application board Differential audio output (SPK_P, SPK_N) shared for all the analog audio path modes: the pins can be connected to the input of an external analog audio device or can be connected to an external speaker I2S digital audio interface: 4-wire digital audio interface (I2S_TXD, I2S_RXD, I2S_CLK, I2S_WA) that can be configured by AT command in PCM or in normal I2S mode For more details regarding audio interfaces configuration and usage, see the u-blox AT Commands Manual [1] and the SARA-G3 / SARA-U2 Series System Integration Manual [2]. 2.7 GPIO SARA-G340 and SARA-G350 modules provide 4 GPIO pins (GPIO1-GPIO4) that can be configured for general purpose input/output, or to provide custom functions via u-blox AT commands (for further details, see the SARA-G3 / SARA-U2 Series System Integration Manual [2] and to u-blox AT Commands Manual [1], +UGPIOC, +UGPIOR, +UGPIOW, +UGPS, +UGPRF). Table 5 summarizes the custom functions available on the GPIO pins of SARA-G340 / SARA-G350 modules. Function Description Default GPIO Configurable GPIOs GNSS supply enable Enable/disable the supply of u-blox positioning chips and modules connected to cellular module GPIO2 GPIO1, GPIO2, GPIO3, GPIO4 GNSS data ready Sense when u-blox positioning chip / module connected to cellular module is ready for sending data by the DDC (I2C) GPIO3 GPIO3 GNSS RTC sharing RTC (Real Time Clock) synchronization signal to u-blox positioning chips and modules connected to cellular module GPIO4 GPIO4 Network status indication Indicates network status: registered home network, registered roaming, data transmission, no service -- GPIO1, GPIO2, GPIO3, GPIO4 GSM Tx-burst indication Indicates when a GSM Tx burst/slot occurs -- GPIO1 Jamming condition indication Indicates when a jamming condition occurs -- GPIO1, GPIO2, GPIO3, GPIO4 General purpose input Input to sense high or low digital level -- GPIO1, GPIO2, GPIO3, GPIO4 General purpose output Output to set the high or the low digital level -- GPIO1, GPIO2, GPIO3, GPIO4 Pad disabled Tri-state with an internal active pull-down enabled GPIO1 GPIO1, GPIO2, GPIO3, GPIO4 Table 5: GPIO custom functions configuration UBX-13000993 - R21 Interfaces Page 17 of 49 64 63 62 61 60 59 58 57 56 55 54 VCC GND 1 52 VCC V_BCKP 2 51 VCC GND 3 50 GND V_INT 4 49 RSVD GND 5 DSR GND GND ANT GND GND GND 49 6 48 RSVD DSR MIC_P 6 48 RI 7 47 RSVD MIC_N RI 7 47 DCD 8 46 MIC_GND RSVD DCD 8 46 DTR 9 MIC_BIAS 45 RSVD DTR 9 45 RTS 10 SPK_N 44 RSVD RTS 10 44 CTS 11 SPK_P 43 GND CTS 11 43 TXD 12 GND 42 SIM_DET TXD 12 42 RXD 13 SIM_DET 41 VSIM RXD 13 41 GND 14 VSIM 40 SIM_RST GND 14 40 PWR_ON SIM_RST 15 39 SIM_IO PWR_ON 15 39 SIM_IO RSVD 16 38 SIM_CLK GPIO1 16 38 SIM_CLK RSVD 17 37 RSVD RSVD 17 37 I2S_RXD RESET_N 18 36 RSVD RESET_N 18 36 I2S_CLK RSVD 19 35 RSVD RSVD 19 35 I2S_TXD GND 20 34 RSVD GND 20 34 I2S_WA GND 21 33 RSVD GND 21 33 RSVD 71 72 73 74 75 76 77 78 79 80 SARA-G300 SARA-G310 Top View 81 82 83 84 Pin 65-96: GND 85 86 91 87 92 88 93 89 94 90 95 96 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 SARA-G340 SARA-G350 Top View 81 82 83 84 Pin 65-96: GND 85 86 91 87 92 88 93 89 94 90 95 96 22 23 24 25 26 27 28 29 30 31 32 GND GND EXT32K GND TXD_AUX RXD_AUX RSVD RSVD RSVD 32K_OUT GND RSVD 22 23 24 25 26 27 28 29 30 31 32 65 GND 5 70 RSVD GND GND VCC 50 69 GND 4 68 TXD_AUX V_INT GND VCC 51 67 RXD_AUX 3 GND VCC 52 66 SCL GND ANT_DET 53 65 SDA 2 GPIO4 V_BCKP 64 63 62 61 60 59 58 57 56 55 54 53 GPIO3 1 GPIO2 GND GND GND GND ANT GND GND GND GND GND Pin assignment RSVD 3.1 GND Pin definition GND 3 GND SARA-G3 series - Data Sheet Figure 3: SARA-G3 series modules - pin assignments UBX-13000993 - R21 Pin definition Page 18 of 49 SARA-G3 series - Data Sheet No Module Name Power domain I/O Description Remarks 1 All GND - N/A Ground All the GND pads must be connected to ground. 2 All V_BCKP - I/O Real Time Clock supply input/output V_BCKP = 2.3 V (typical) generated by the module to supply the Real Time Clock when VCC supply voltage is within valid operating range. See section 4.2.3 for detailed electrical specs. 3 All GND - N/A Ground All the GND pads must be connected to ground. 4 All V_INT - O Digital I/O Interfaces supply output V_INT = 1.8V (typical) generated by the module when it is switched-on. See section 4.2.3 for detailed electrical specs. 5 All GND - N/A Ground All the GND pads must be connected to ground. 6 All DSR GDI O UART data set ready Circuit 107 (DSR) in ITU-T V.24. Output driver class A. PU/PD class a. Value at reset: T/PU. See section 4.2.11 for detailed electrical specs. 7 All RI GDI O UART ring indicator Circuit 125 (RI) in ITU-T V.24. Output driver class A. PU/PD class b. Value at reset: T/PU. See section 4.2.11 for detailed electrical specs. 8 All DCD GDI O UART data carrier detect Circuit 109 (DCD) in ITU-T V.24. Output driver class A. PU/PD class a. Value at reset: T/PU. See section 4.2.11 for detailed electrical specs. 9 All DTR GDI I UART data terminal ready Circuit 108/2 (DTR) in ITU-T V.24. Internal active pull-up to V_INT enabled. PU/PD class b. Value at reset: T/PU. See section 4.2.11 for detailed electrical specs. 10 All RTS GDI I UART ready to send Circuit 105 (RTS) in ITU-T V.24. Internal active pull-up to V_INT enabled. PU/PD class c. Value at reset: T/PU. See section 4.2.11 for detailed electrical specs. 11 All CTS GDI O UART clear to send Circuit 106 (CTS) in ITU-T V.24. Output driver class A. PU/PD class c. Value at reset: T/PD. See section 4.2.11 for detailed electrical specs. 12 All TXD GDI I UART transmitted data Circuit 103 (TxD) in ITU-T V.24. Internal active pull-up to V_INT enabled. PU/PD class a. Value at reset: T/PU. See section 4.2.11 for detailed electrical specs. 13 All RXD GDI O UART received data Circuit 104 (RxD) in ITU-T V.24. Output driver class B. PU/PD class a. Value at reset: T/PU. See section 4.2.11 for detailed electrical specs. 14 All GND - N/A Ground All the GND pads must be connected to ground. 15 All PWR_ON POS I Power-on input The PWR_ON pin has high input impedance: don't leave it floating in noisy environment (an external pull-up resistor is required). See section 4.2.7 for detailed electrical specs. 16 SARA-G350 SARA-G340 GPIO1 GDI I/O GPIO Configurable GPIO: see Table 5 for the available custom functions. Output driver class A. PU/PD class b. Value at reset: T/PD. See section 4.2.11 for detailed electrical specs. SARA-G310 SARA-G300 RSVD - N/A RESERVED pin Pin disabled. Leave unconnected. All RSVD - N/A RESERVED pin Leave unconnected. 17 UBX-13000993 - R21 Pin definition Page 19 of 49 SARA-G3 series - Data Sheet No Module Name Power domain I/O Description Remarks 18 All RESET_N ERS I Reset signal A series Schottky diode is integrated in the module as protection, and then an internal 10 k pull-up resistor to V_INT is provided. See section 4.2.8 for detailed electrical specs. For more details regarding module reset, see [2]. 19 All RSVD - N/A RESERVED pin Leave unconnected. 20 All GND - N/A Ground All the GND pads must be connected to ground. 21 All GND - N/A Ground All the GND pads must be connected to ground. 22 All GND - N/A Ground All the GND pads must be connected to ground. 23 SARA-G350 SARA-G340 GPIO2 GDI I/O GPIO By default, the pin is configured to provide the GNSS supply enable function. Output driver class A. PU/PD class b. Value at reset: T/PD. See section 4.2.11 for detailed electrical specs. SARA-G310 SARA-G300 RSVD - N/A RESERVED pin Pin disabled. Leave unconnected. SARA-G350 SARA-G340 GPIO3 GDI I/O GPIO By default, the pin is configured to provide the GNSS data ready function. Output driver class B. PU/PD class c. Value at reset: T/PD. See section 4.2.11 for detailed electrical specs. SARA-G310 SARA-G300 32K_OUT - O 32 kHz output 32 kHz output suitable only to feed the EXT32K input giving the RTC reference clock, allowing low power idle-mode and RTC functions support. SARA-G350 SARA-G340 GPIO4 GDI I/O GPIO By default, the pin is configured to provide the GNSS RTC sharing function. Output driver class A. PU/PD class b. Value at reset: T/PD. See section 4.2.11 for detailed electrical specs. SARA-G310 SARA-G300 RSVD - N/A RESERVED pin Pin disabled. Leave unconnected. SARA-G350 SARA-G340 SDA DDC I/O I2C bus data line Fixed open drain. No internal pull-up. Value at reset: T. See section 4.2.12 for detailed electrical specs. SARA-G310 SARA-G300 RSVD - N/A RESERVED pin Pin disabled. Leave unconnected. SARA-G350 SARA-G340 SCL DDC O I2C bus clock line Fixed open drain. No internal pull-up. Value at reset: T. See section 4.2.12 for detailed electrical specs. SARA-G310 SARA-G300 RSVD - N/A RESERVED pin Pin disabled. Leave unconnected. 28 All RXD_AUX GDI O Auxiliary UART received data Circuit 104 (RxD) in ITU-T V.24. Output driver class B. PU/PD class a. Value at reset: T/PU. See section 4.2.11 for detailed electrical specs. 29 All TXD_AUX GDI I Auxiliary UART transmitted data Circuit 103 (TxD) in ITU-T V.24. Internal active pull-up to V_INT enabled. PU/PD class a. Value at reset: T/PU. See section 4.2.11 for detailed electrical specs. 30 All GND - N/A Ground All the GND pads must be connected to ground. 31 SARA-G350 SARA-G340 RSVD - N/A RESERVED pin Internally not connected. Leave unconnected. SARA-G310 SARA-G300 EXT32K - I 32 kHz input Input for RTC reference clock, needed to enter the low power idle-mode and provide RTC functions. See section 4.2.9 for detailed electrical specs. 32 All GND - N/A Ground All the GND pads must be connected to ground. 33 All RSVD - N/A RESERVED pin This pin must be connected to GND. 24 25 26 27 UBX-13000993 - R21 Pin definition Page 20 of 49 SARA-G3 series - Data Sheet No Module Name Power domain I/O Description Remarks 34 SARA-G350 SARA-G340 I2S_WA GDI O I2S word alignment Output driver class A. PU/PD class c. Value at reset: T/PU. See section 4.2.11 for detailed electrical specs. SARA-G310 SARA-G300 RSVD - N/A RESERVED pin Pin disabled. Leave unconnected. SARA-G350 SARA-G340 I2S_TXD GDI O I2S transmit data Output driver class B. PU/PD class c. Value at reset: T/PD. See section 4.2.11 for detailed electrical specs. SARA-G310 SARA-G300 RSVD - N/A RESERVED pin Pin disabled. Leave unconnected. SARA-G350 SARA-G340 I2S_CLK GDI O I2S clock Output driver class B. PU/PD class a. Value at reset: T/PU. See section 4.2.11 for detailed electrical specs. SARA-G310 SARA-G300 RSVD - N/A RESERVED pin Pin disabled. Leave unconnected. SARA-G350 SARA-G340 I2S_RXD GDI I I2S receive data Internal active pull-down enabled. PU/PD class a. Value at reset: T/PD. See section 4.2.11 for detailed electrical specs. SARA-G310 SARA-G300 RSVD - N/A RESERVED pin Pin disabled. Leave unconnected. 38 All SIM_CLK SIM O SIM clock Value at reset: L. See section 4.2.10 for detailed electrical specs. 39 All SIM_IO SIM I/O SIM data Internal 4.7k pull-up to VSIM. Value at reset: L. See section 4.2.10 for detailed electrical specs. 40 All SIM_RST SIM O SIM reset Value at reset: L. See section 4.2.10 for detailed electrical specs. 41 All VSIM - O SIM supply output VSIM = 1.80 V typical if SIM card = 1.8V type. VSIM = 2.85 V typical if SIM card = 3.0V type. See section 4.2.3 for detailed electrical specs. 42 All SIM_DET GDI I SIM detection SIM card presence detection function. PU/PD class a. Value at reset: T/PU. See section 4.2.11 for detailed electrical specs. 43 All GND - N/A Ground All the GND pads must be connected to ground. 44 SARA-G350 SARA-G340 SPK_P AUDIO O Differential analog audio output (positive) Differential analog audio output shared for all the analog audio path modes. See section 4.2.13 for detailed electrical specs. SARA-G310 SARA-G300 RSVD - N/A RESERVED pin Leave unconnected. SARA-G350 SARA-G340 SPK_N AUDIO O Differential analog audio output (negative) Differential analog audio output shared for all the analog audio path modes. See section 4.2.13 for detailed electrical specs. SARA-G310 SARA-G300 RSVD - N/A RESERVED pin Leave unconnected. SARA-G350 SARA-G340 MIC_BIAS AUDIO O Microphone supply output Supply output for the external microphone. See section 4.2.13 for detailed electrical specs. SARA-G310 SARA-G300 RSVD - N/A RESERVED pin Leave unconnected. SARA-G350 SARA-G340 MIC_GND AUDIO I Microphone analog reference Local ground for the external microphone (reference for the differential analog audio input). See section 4.2.13 for detailed electrical specs. SARA-G310 SARA-G300 RSVD - N/A RESERVED pin Leave unconnected. SARA-G350 SARA-G340 MIC_N AUDIO I Differential analog audio input (negative) Differential analog audio input shared for all the analog audio path modes. See section 4.2.13 for detailed electrical specs. 35 36 37 45 46 47 48 UBX-13000993 - R21 Pin definition Page 21 of 49 SARA-G3 series - Data Sheet Module Name Power domain I/O Description Remarks SARA-G310 SARA-G300 RSVD - N/A RESERVED pin Leave unconnected. SARA-G350 SARA-G340 MIC_P AUDIO I Differential analog audio input (positive) Differential analog audio input shared for all the analog audio path modes. See section 4.2.13 for detailed electrical specs. SARA-G310 SARA-G300 RSVD - N/A RESERVED pin Leave unconnected. 50 All GND - N/A Ground All the GND pads must be connected to ground. 51 All VCC - I Module supply input All VCC pins must be connected to external supply. Supply input for internal BB PMU and transceiver on SARA-G3 modules product versions `02' onward. See section 4.2.3, 4.2.4 for detailed electrical spec. 52 All VCC - I Module supply input All VCC pins must be connected to external supply. Supply input for the internal RF power amplifier on SARA-G3 modules product versions `02' onward. See section 4.2.3, 4.2.4 for detailed electrical spec. 53 All VCC - I Module supply input All VCC pins must be connected to external supply. Supply input for the internal RF power amplifier on SARA-G3 modules product versions `02' onward. See section 4.2.3, 4.2.4 for detailed electrical spec. 54 All GND - N/A Ground All the GND pads must be connected to ground. 55 All GND - N/A Ground All the GND pads must be connected to ground. 56 All ANT - I/O RF antenna 50 nominal impedance See section 4.2.5 for detailed electrical specs. 57 All GND - N/A Ground All the GND pads must be connected to ground. 58 All GND - N/A Ground All the GND pads must be connected to ground. 59 All GND - N/A Ground All the GND pads must be connected to ground. 60 All GND - N/A Ground All the GND pads must be connected to ground. 61 All GND - N/A Ground All the GND pads must be connected to ground. 62 SARA-G350 SARA-G340 ANT_DET ADC I Antenna detection Antenna presence detection function. See section 4.2.6 for detailed electrical specs. SARA-G310 SARA-G300 RSVD - N/A RESERVED pin Leave unconnected. 63 All GND - N/A Ground All the GND pads must be connected to ground. 64 All GND - N/A Ground All the GND pads must be connected to ground. 6596 All GND - N/A Ground All the GND pads must be connected to ground. No 49 Table 6: SARA-G3 series module pin-out For more information about pin-out, see the SARA-G3 / SARA-U2 Series System Integration Manual [2]. For an explanation of abbreviations and terms used, see Appendix A. UBX-13000993 - R21 Pin definition Page 22 of 49 SARA-G3 series - Data Sheet 4 Electrical specifications Stressing the device above one or more of the ratings listed in the Absolute Maximum Rating section may cause permanent damage. These are stress ratings only. Operating the module at these or at any conditions other than those specified in the Operating Conditions sections (chapter 4.2) of the specification should be avoided. Exposure to Absolute Maximum Rating conditions for extended periods may affect device reliability. Operating conditions ranges define those limits within which the functionality of the device is guaranteed. Electrical characteristics are defined according to the verification on a representative number of samples or according to the simulation. Where application information is given, it is advisory only and does not form part of the specification. 4.1 Absolute maximum rating Limiting values given below are in accordance with the Absolute Maximum Rating System (IEC 134). Symbol Description Condition Min Max Unit VCC Module supply voltage Input DC voltage at VCC pins -0.15 5.5 V V_BCKP RTC supply voltage Input DC voltage at V_BCKP pin -0.15 2.5 V GDI Generic digital interfaces Input DC voltage at Generic digital interfaces pins -0.15 2.2 V DDC DDC interface Input DC voltage at DDC interface pins -0.15 3.6 V SIM SIM interface Input DC voltage at SIM interface pins -0.30 3.6 V ERS External reset signal Input DC voltage at RESET_N pin -0.15 6.0 V POS Power-on signal Input DC voltage at PWR_ON pin -0.15 6.0 V AUDIO Audio pins Input DC voltage at Audio pins -0.15 3.0 V ADC Antenna detection pin Input DC voltage at ANT_DET pin -0.15 3.0 V P_ANT Antenna power In-band input RF power at ANT pin -8 dBm Rho_ANT Antenna ruggedness Output RF load mismatch ruggedness at ANT pin 20:1 VSWR Tstg Storage temperature range +85 C -40 Table 7: Absolute maximum ratings The product is not protected against overvoltage or reversed voltages. If necessary, voltage spikes exceeding the power supply voltage specification, given in table above, must be limited to values within the specified boundaries by using appropriate protection devices. 4.1.1 Maximum ESD Parameter Max Unit Remarks ESD sensitivity for all pins except ANT pin Min Typical 1000 V Human Body Model according to JESD22-A114 ESD sensitivity for ANT pin 1000 V Human Body Model according to JESD22-A114 ESD immunity for ANT pin 4000 V Contact Discharge according to IEC 61000-4-2 8000 V Air Discharge according to IEC 61000-4-2 Table 8: Maximum ESD ratings UBX-13000993 - R21 Electrical specifications Page 23 of 49 SARA-G3 series - Data Sheet u-blox cellular modules are Electrostatic Sensitive Devices (ESD) and require special precautions when handling. See section 7.4 for ESD handling instructions. 4.2 Operating conditions Unless otherwise specified, all operating condition specifications are at an ambient temperature of +25 C. Operation beyond the operating conditions is not recommended and extended exposure beyond them may affect device reliability 4.2.1 Operating temperature range Symbol Parameter Module Min Typical Max Units Remarks Topr Operating temperature range All -40 +25 +85 C All -30 +85 C Normal operating range see chapter 4.2.1.1 All -40 +85 C Extended operating range see chapter 4.2.1.2 Table 9: Environmental conditions 4.2.1.1 Normal operating temperature range SARA-G3 series modules are fully functional and meet 3GPP specifications across the specified temperature range. 4.2.1.2 Extended operating temperature range SARA-G3 series modules are fully functional across the specified temperature range. RF performance may be affected outside the normal operating temperature range. 4.2.2 Module thermal resistance Symbol Parameter Unit Remarks Rth,M-A Module-to-Ambient thermal resistance Min Typical 10.6 Max C/W Thermal resistance from the module internal temperature sensor to the ambient, with the module mounted on a 79 mm x 62 mm x 1.41 mm 4-layer PCB with a high coverage of copper in still air conditions Rth,M-C Module-to-Case thermal resistance 1.7 C/W Thermal resistance from the module internal temperature sensor to the module case, evaluated as the thermal resistance from the module internal temperature sensor to the ambient, with the module mounted on a 79 mm x 62 mm x 1.41 mm 4-layer PCB with a high coverage of copper, with a robust aluminum heat-sink on the back of the application board, with forced air ventilation. Table 10: SARA-G3 series modules thermal resistance UBX-13000993 - R21 Electrical specifications Page 24 of 49 SARA-G3 series - Data Sheet 4.2.3 Supply/Power pins Symbol Parameter VCC Module supply normal operating voltage ICC_PEAK 21 Min Typical Max Unit 3.35 3.80 4.50 V Module supply extended operating voltage 19 3.00 4.50 V Module supply extended operating voltage 20 2.80 4.50 V 1.60 A Module peak of current consumption through all the VCC pins, during a GSM 1-slot transmit burst at maximum power level, with a mismatched antenna 1.90 A Module peak of current consumption through the VCC pin #51 of SARA-G3 modules product versions "02" onwards 300 mA 2.40 V 18 1.50 Module peak of current consumption through all the VCC pins, during a GSM 1-slot transmit burst at maximum power level, with a matched antenna V_BCKP Real Time Clock Supply input voltage I_BCKP Real Time Clock Supply average current consumption, at V_BCKP = 2.3 V 1.00 2.30 2.00 A Table 11: Input characteristics of Supply/Power pins Symbol Parameter Min Typical Max Unit VSIM SIM Supply 1.76 1.80 1.84 V 2.78 2.85 2.91 V V_BCKP Real Time Clock Supply output voltage 2.19 2.30 2.42 V I_BCKP Real Time Clock Supply output current capability 2 mA V_INT Digital I/O Interfaces supply output voltage 1.85 V V_INT_RIPPLE Digital I/O Interfaces supply output peak-to-peak voltage ripple during active or connected mode 15 mV Digital I/O Interfaces supply output peak-to-peak voltage ripple during low power idle mode with power saving enabled 90 mV Digital I/O Interfaces supply output current capability 70 mA I_INT 1.75 1.80 Table 12: Output characteristics of Supply/Power pins 4.2.4 Current consumption Mode Module Band Condition Typ Max Unit Power Off Mode All - Module is switched off by AT+CPWROFF 36 40 A Idle-Mode (Power Saving enabled by AT+UPSV, module in low power idlemode, equivalent to +CFUN=4 or +COPS=2) SARA-G300 SARA-G310 - Averaged current over a 100-ms period, EXT32K fed by external 32.768 kHz signal 0.3 0.4 mA Averaged current over a 100-ms period, EXT32K fed by 32K_OUT output signal 3.9 4.0 mA Averaged current over a 100-ms period 0.3 0.4 mA SARA-G340 SARA-G350 - Min The input voltage at all the VCC must be above the normal operating range minimum limit to switch-on the module. Module is still fully functional when the input voltage at the VCC pins drops below the herein stated normal operating range minimum limit, but RF performance may be affected. 19 Range defined for all the VCC pins of product versions "00" and "01", and the VCC pin #51 (supply input for internal baseband Power Management Unit and the internal transceiver) of product versions "02" onwards. Module may switch off when the input voltage at the related pins drops below the herein stated extended operating range minimum limit. 20 Range defined for the VCC pins #52 and #53 (supply input for the internal power amplifier) of product versions "02" onwards. 21 Use this figure to dimension maximum current capability of power supply. 18 UBX-13000993 - R21 Electrical specifications Page 25 of 49 SARA-G3 series - Data Sheet Mode Module Band Condition Cyclic Idle/Active-Mode (Power Saving enabled by AT+UPSV, Module registered with network) SARA-G300 SARA-G310 All SARA-G340 SARA-G350 Active-Mode (Power Saving disabled by AT+UPSV, Module registered with network) GSM Connected Mode (Call enabled) GPRS Connected Mode (Call enabled) SARA-G300 SARA-G310 All All Min Typ Max Unit Averaged current over a 10-minute period, DRX = 922, AT+UPSV=2 EXT32K fed by external 32.768 kHz signal 0.6 0.8 mA Averaged current over a 10-minute period, DRX = 922, AT+UPSV=2 EXT32K fed by 32K_OUT output signal 4.2 4.4 mA Averaged current over a 10-minute period, DRX = 523, AT+UPSV=1 EXT32K fed by external 32.768 kHz signal 0.9 1.1 mA Averaged current over a 10-minute period, DRX = 523, AT+UPSV=1 EXT32K fed by 32K_OUT output signal 4.5 4.7 mA Averaged current over a 10-minute period, DRX = 922, AT+UPSV=2 0.6 0.8 mA Averaged current over a 10-minute period, DRX = 523, AT+UPSV=1 0.9 1.1 mA Averaged current over a 10-minute period, DRX = 523, AT+UPSV=0 (default) EXT32K fed by external 32.768 kHz signal 4.2 4.4 mA Averaged current over a 10-minute period, DRX = 523, AT+UPSV=0 (default) EXT32K fed by 32K_OUT output signal 4.5 4.7 mA Averaged current over a 10-minute period, DRX = 523, AT+UPSV=0 (default) EXT32K not fed 18.0 18.2 mA SARA-G340 SARA-G350 All Averaged current over a 10-minute period, DRX = 523, AT+UPSV=0 (default)24 2.9 3.1 mA All 850, 900 Averaged current over a 10-second period, 1 Tx + 1 Rx slot Maximum Tx power (32.2 dBm typ.) 200 250 mA 1800, 1900 Averaged current over a 10-second period, 1 Tx + 1 Rx slot Maximum Tx power (29.2 dBm typ.) 150 200 mA 850, 900 Averaged current over a 10-second period, 2 Tx + 3 Rx slots Maximum Tx power (30.5 dBm typ.) 300 350 mA 1800, 1900 Averaged current over a 10-second period, 2 Tx + 3 Rx slots Maximum Tx power (27.5 dBm typ.) 210 260 mA All Table 13: VCC current consumption25 Module is registered with the network, with a paging period of 2.12 s (2G network DRX setting = 9), with none neighbour cell. Module is registered with the network, with a paging period of 1.18 s (2G network DRX setting = 5), with 16 neighbour cells. 24 18.2 mA typical, 18.4 mA maximum for SARA-G340 and SARA-G350 modules product versions "00" 25 Averaged values for module current consumption through VCC pins in the listed modes/conditions 22 23 UBX-13000993 - R21 Electrical specifications Page 26 of 49 SARA-G3 series - Data Sheet 4.2.5 RF performance Parameter Min Max Unit Remarks Frequency range GSM 850 Uplink 824 849 MHz Module transmit Downlink 869 894 MHz Module receive Frequency range E-GSM 900 Uplink 880 915 MHz Module transmit Downlink 925 960 MHz Module receive Frequency range DCS 1800 Uplink 1710 1785 MHz Module transmit Downlink 1805 1880 MHz Module receive Frequency range PCS 1900 Uplink 1850 1910 MHz Module transmit Downlink 1930 1990 MHz Module receive Typical Max Table 14: Operating RF frequency bands Parameter Unit Remarks Receiver input sensitivity GSM 850 Min -109 dBm Downlink RF level @ BER Class II < 2.4 % Receiver input sensitivity E-GSM 900 -109 dBm Downlink RF level @ BER Class II < 2.4 % Receiver input sensitivity DCS 1800 -109 dBm Downlink RF level @ BER Class II < 2.4 % Receiver input sensitivity PCS 1900 -109 dBm Downlink RF level @ BER Class II < 2.4 % Condition: 50 source Table 15: Receiver sensitivity performance Parameter Min Maximum output power GSM 850 / E-GSM 900 Maximum output power DCS 1800 / PCS 1900 Typical Max Unit Remarks 32.2 dBm Uplink burst RF power for GSM or GPRS 1-slot TCH at maximum output power control level (PCL 5 or Gamma 3) 30.5 dBm Uplink burst RF power for GPRS 2-slot TCH at maximum output power control level (Gamma 3) 29.2 dBm Uplink burst RF power for GSM or GPRS 1-slot TCH at maximum output power control level (PCL 0 or Gamma 3) 27.5 dBm Uplink burst RF power for GPRS 2-slot TCH at maximum output power control level (Gamma 3) Condition: 50 output load Table 16: Transmitter maximum output power 4.2.6 ANT_DET pin Pin Name Parameter ANT_DET Output DC current pulse value Output DC current pulse time length Min Typical Max 20 3.7 5.4 Unit Remarks A 8.1 ms Table 17: ANT_DET pin characteristics UBX-13000993 - R21 Electrical specifications Page 27 of 49 SARA-G3 series - Data Sheet 4.2.7 PWR_ON pin Pin Name Parameter Min Typical Max Unit Remarks PWR_ON Internal supply for Power-On Input Signal 2.19 2.30 2.42 V Real Time Clock supply (V_BCKP) L-level input -0.10 0.65 V High input impedance (no internal pull-up) H-level input 2.00 4.50 V High input impedance (no internal pull-up) L-level input current PWR_ON low time to switch-on the module -8 A 5 ms Table 18: PWR_ON pin characteristics 4.2.8 RESET_N pin Pin Name Parameter Min Typical Max Unit Remarks RESET_N Internal supply for External Reset Signal 1.75 1.80 1.85 V Digital I/O Interfaces supply (V_INT) L-level input -0.10 0.15 V A series Schottky diode is integrated in the module as protection: the module senses a low level when the RESET_N pin is forced low. H-level input 1.40 4.50 V A series Schottky diode is integrated in the module as protection: the module senses a low level when the RESET_N pin is forced low. 10 k Internal pull-up to V_INT after the internal series Schottky diode -180 A Pull-up resistance L-level input current RESET_N low time to perform a proper reset 50 ms SARA-G340, SARA-G350 RESET_N low time to perform a proper reset 3000 ms SARA-G300, SARA-G310 Table 19: RESET_N pin characteristics 4.2.9 EXT32K pin Pin Name Parameter Min Typical Max Unit EXT32K L-level input H-level input Input clock frequency 32.765 -0.25 0.20 V V_BCKP - 0.20 V_BCKP + 0.25 V V_BCKP = 2.3 V (typical) generated by the internal LDO linear regulator when valid VCC supply is present. 32.771 kHz Frequency tolerance: +/- 100 ppm 32.768 Remarks Table 20: EXT32K pin characteristics UBX-13000993 - R21 Electrical specifications Page 28 of 49 SARA-G3 series - Data Sheet 4.2.10 SIM pins Parameter Min Typical Max Unit Remarks 0.37 V VSIM = 1.80 V 0.60 V VSIM = 2.85 V 1.22 3.30 V VSIM = 1.80 V 1.95 3.30 V VSIM = 2.85 V 0.00 0.35 V VSIM = 1.80 V, Max value at IOL = +1.0 mA 0.00 0.35 V VSIM = 2.85 V, Max value at IOL = +1.0 mA Low-level input High-level input Low-level output High-level output 1.45 1.80 V VSIM = 1.80 V, Min value at IOH = -1.0 mA 2.50 2.85 V VSIM = 2.85 V, Min value at IOH = -1.0 mA A 0.2 V < VIN < 3.3 V Input/Output leakage current 0.7 Internal pull-up resistor on SIM_IO to VSIM 4.7 k Clock frequency on SIM_CLK 3.25 MHz Table 21: SIM pins characteristics 4.2.11 Generic Digital Interfaces pins Parameter Min Typical Max Unit Remarks Internal supply for GDI domain 1.75 1.80 1.85 V Digital I/O Interfaces supply (V_INT) Input characteristic: L-level input -0.20 0.35 V Input characteristic: H-level input 1.30 1.95 V 0.00 0.20 V Max value at IOL = +3.0 mA for Driver Class A 0.00 0.35 V Max value at IOL = +6.0 mA for Driver Class A 0.00 0.20 V Max value at IOL = +2.5 mA for Driver Class B 0.00 0.35 V Max value at IOL = +5.0 mA for Driver Class B Output characteristics: L-level output Output characteristics: H-level output 1.60 1.80 V Min value at IOH = -3.0 mA for Driver Class A 1.45 1.80 V Min value at IOH = -6.0 mA for Driver Class A 1.60 1.80 V Min value at IOH = -2.5 mA for Driver Class B 1.45 1.80 V Min value at IOH = -5.0 mA for Driver Class B A 0.2 V < VIN < 1.95 V -102 A PU Class a -55 A PU Class b -31 A PU Class c 103 A PD Class a 51 A PD Class b 27 A PD Class c Input/Output leakage current Pull-up input current Pull-down input current 0.7 Table 22: GDI pins characteristics UBX-13000993 - R21 Electrical specifications Page 29 of 49 SARA-G3 series - Data Sheet 4.2.11.1 AC characteristics of digital audio interfaces pins The 4-wire I2S digital audio interfaces can be configured in 2 different modes: Normal I2S mode with Master role PCM mode with Master role 4.2.11.1.1 Normal I2S mode with Master role T1 T2 T3 I2S_CLK T4 T5 I2S_TX / I2S_WA T6 T7 I2S_RX Figure 4: AC characteristics of digital audio interface in normal I2S mode ( = 2, 4, 6, 8, 10, 12) T1 T2 T3 I2S_CLK T4 T5 I2S_TX / I2S_WA T6 T7 I2S_RX Figure 5: AC characteristics of digital audio interface in normal I2S mode ( = 3, 5, 7, 9, 11, 13) Parameter Description Min Typical T1 I2S_CLK period 3.902 1/T1 I2S_CLK frequency T2 I2S_CLK high time T3 I2S_CLK low time T4 T5 T6 T7 Max Unit Remarks 3.906 s = 2,..,13 256 kHz = 2,..,13 1.933 1.953 s = 2,..,13 1.933 1.953 s = 2,..,13 I2S_WA period 125.0 s = 2,..,13 I2S_WA frequency 8 kHz = 2,..,13 I2S_TX invalid before I2S_CLK low end 24 ns = 2,4,6,8,10,12 I2S_TX invalid before I2S_CLK high end 24 ns = 3,5,7,9,11,13 I2S_TX valid after I2S_CLK high begin 31 ns = 2,4,6,8,10,12 I2S_TX valid after I2S_CLK low begin 31 ns = 3,5,7,9,11,13 I2S_RX setup time before I2S_CLK high end 60 ns = 2,4,6,8,10,12 I2S_RX setup time before I2S_CLK low end 60 ns = 3,5,7,9,11,13 I2S_RX hold time after I2S_CLK low begin 12 ns = 2,4,6,8,10,12 I2S_RX hold time after I2S_CLK high begin 12 ns = 3,5,7,9,11,13 Table 23: AC characteristics of digital audio interface in normal I2S mode ( = 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13) UBX-13000993 - R21 Electrical specifications Page 30 of 49 SARA-G3 series - Data Sheet 4.2.11.1.2 PCM mode with Master role I2S_WA T4 T1 T5 I2S_CLK T2 I2S_TX T3 T6 LSB T7 M SB T8 I2S_RX LSB T9 M SB Figure 6: AC characteristics of digital audio interface in PCM mode ( = 0) I2S_WA T4 T5 T1 I2S_CLK T6 I2S_TX LSB T7 T2 M SB T8 I2S_RX T3 LSB T9 M SB Figure 7: AC characteristics of digital audio interface in PCM mode ( = 1) Parameter Description Min Typical T1 I2S_CLK period 6.940 7.349 1/T1 T2 T3 Unit Remarks 6.944 s = 0 7.353 s = 1 144 kHz = 0 136 kHz = 1 3.452 3.472 s = 0 3.656 3.676 s = 1 3.452 3.472 s = 0 3.656 3.676 s = 1 I2S_WA period 125.0 s = 0,1 I2S_WA frequency 8 kHz = 0,1 I2S_CLK frequency I2S_CLK low time I2S_CLK high time Max T4 I2S_CLK high begin to I2S_WA high begin -24 31 ns = 0,1 T5 I2S_CLK low end to I2S_WA high end -24 31 ns = 0,1 T6 I2S_TX invalid before I2S_CLK low end 24 ns = 0,1 T7 I2S_TX valid after I2S_CLK high begin 22 ns = 0,1 T8 I2S_RX setup time before I2S_CLK high end 60 ns = 0,1 T9 I2S_RX hold time after I2S_CLK low begin 12 ns = 0,1 Table 24: AC characteristics of digital audio interface in PCM mode ( = 0, 1) UBX-13000993 - R21 Electrical specifications Page 31 of 49 SARA-G3 series - Data Sheet 4.2.12 DDC (I2C) pins Parameter Min Typical Max Unit Remarks Internal supply for DDC domain 1.75 1.80 1.85 V Digital I/O Interfaces supply (V_INT) L-level input -0.20 0.35 V In accordance with I2C bus specification H-level input 1.30 3.30 V In accordance with I2C bus specification 0.40 V Max value at IOL = +3.0 mA 0.7 A 0.2 V < VIN < 3.3 V L-level output 0.00 Input/Output leakage current Clock frequency on SCL 100 kHz Table 25: DDC pins characteristics 4.2.13 Audio pins Pin Name Parameter MIC_BIAS Microphone supply output voltage Typical Max 2.2 Unit Remarks V Provided by MIC_BIAS output pin with MIC_GND pin as reference. Microphone supply output current 4.0 mA Provided by MIC_BIAS output pin with MIC_GND pin as reference Load capacitance 0 nF Proper internal bypass capacitor is already provided to guarantee stable operation: an external capacitor cannot be directly connected to MIC_BIAS pin, but can be provided after a proper series resistor. Load resistance MIC_GND Min 1 k Microphone ground 0 V MIC_GND pin is internally connected to GND as a sense line Max Unit Remarks 0.8 Vpp Full scale differential voltage Table 26: Microphone supply (MIC_BIAS) characteristics Pin Name Parameter MIC_P/MIC_N Differential input voltage Min Typical Differential input resistance 50 k Common mode DC voltage 0.5 V No internal DC blocking capacitor Input capacitance pF No internal DC blocking capacitor Signal to noise 75 5 10 dB Gain stage = +12 dB, Bandwidth 300-3900 Hz Signal to distortion (THD) 65 dB Power supply rejection 49 85 dB Table 27: Differential audio transmit path (MIC_P, MIC_N) input characteristics UBX-13000993 - R21 Electrical specifications Page 32 of 49 SARA-G3 series - Data Sheet Pin Name Parameter Min Typical Max Unit Remarks SPK_P/SPK_N Maximum differential output voltage 4.0 4.1 4.2 Vpp Full scale differential open circuit voltage 1.25 Common mode output voltage Output current limit Output load resistance V 200 14 mA 250 Single-ended output load capacitance pF Signal to noise 70 80 dB Load = 16 , Gain stage = +0 dB, Input signal = 0 dBFS, Code 0, Aweighted Signal to distortion (THD) 60 70 dB Load = 16 , Input signal = 0 dBFS Table 28: Differential audio receive path (SPK_P, SPK_N) output characteristics UBX-13000993 - R21 Electrical specifications Page 33 of 49 SARA-G3 series - Data Sheet 5 Mechanical specifications Pin 1 Indicator K M1 M2 K F Q E M1 P R L R G H1 J1 B N J2 H 2 ANT pin H J2 2 E O O L I F D G H1 J1 D A C Figure 8: SARA-G3 series dimensions (bottom and sides views) Parameter A B C D E F G H1 H2 I J1 J2 K L M1 M2 N O P Q R Weight Description Typical Module Height [mm] Module Width [mm] Module Thickness 26 [mm] Horizontal Edge to Lateral Pin Pitch [mm] Vertical Edge to Lateral Pin Pitch [mm] Edge to Lateral Pin Pitch [mm] Lateral Pin to Pin Pitch [mm] Lateral Pin Height [mm] Lateral Pin close to ANT Height [mm] Lateral Pin Width [mm] Lateral Pin to Pin Distance [mm] Lateral Pin to Pin close to ANT Distance [mm] Horizontal Edge to Central Pin Pitch [mm] Vertical Edge to Central Pin Pitch [mm] Central Pin to Pin Horizontal Pitch [mm] Central Pin to Pin Horizontal Pitch [mm] Central Pin to Pin Vertical Pitch [mm] Central Pin Height and Width [mm] Horizontal Edge to Pin 1 Indicator Pitch [mm] Vertical Edge to Pin 1 Indicator Pitch [mm] Pin 1 Indicator Height and Width [mm] Module Weight [g] 26.0 16.0 2.4 2.0 2.5 1.05 1.1 0.8 0.9 1.5 0.3 0.2 2.75 2.75 1.8 3.6 2.1 1.1 0.9 1.0 0.6 <3 Tolerance (1023.6 mil) (629.9 mil) (94.5 mil) (78.7 mil) (98.4 mil) (41.3 mil) (43.3 mil) (31.5 mil) (35.4 mil) (59.1 mil) (11.8 mil) (7.9 mil) (108.3 mil) (108.3 mil) (70.9 mil) (141.7 mil) (82.7 mil) (43.3 mil) (35.4 mil) (39.4 mil) (23.6 mil) +0.20/-0.20 +0.20/-0.20 +0.25/-0.15 (+7.9/-7.9 mil) (+7.9/-7.9 mil) (+9.8/-5.9 mil) +0.20/-0.20 +0.20/-0.20 +0.20/-0.20 +0.02/-0.02 +0.02/-0.02 +0.02/-0.02 +0.02/-0.02 +0.02/-0.02 +0.02/-0.02 +0.20/-0.20 +0.20/-0.20 +0.02/-0.02 +0.02/-0.02 +0.02/-0.02 +0.02/-0.02 +0.20/-0.20 +0.20/-0.20 +0.02/-0.02 (+7.9/-7.9 mil) (+7.9/-7.9 mil) (+7.9/-7.9 mil) (+0.8/-0.8 mil) (+0.8/-0.8 mil) (+0.8/-0.8 mil) (+0.8/-0.8 mil) (+0.8/-0.8 mil) (+0.8/-0.8 mil) (+7.9/-7.9 mil) (+7.9/-7.9 mil) (+0.8/-0.8 mil) (+0.8/-0.8 mil) (+0.8/-0.8 mil) (+0.8/-0.8 mil) (+7.9/-7.9 mil) (+7.9/-7.9 mil) (+0.8/-0.8 mil) Table 29: SARA-G3 series dimensions 26 The module height tolerance +/-0.20 mm may be exceeded close to the corners of the PCB due to the cutting process: in the worst cases, the height could be +0.40 mm longer than the typical value. For information regarding suggested footprint (i.e. copper mask) and stencil (i.e. paste mask) layout to be implemented on the application board, see SARA-G3 / SARA-U2 series System Integration Manual [2]. 3.0 mm typical module thickness for SARA-G3 modules product versions "00" and "01" UBX-13000993 - R21 Mechanical specifications Page 34 of 49 SARA-G3 series - Data Sheet 6 Qualification and approvals 6.1 Reliability tests Tests for product family qualifications are according to ISO 16750 "Road vehicles - Environmental conditions and testing for electrical and electronic equipment", and appropriate standards. 6.2 Approvals 6.2.1 SARA-G3 series Products marked with this lead-free symbol on the product label comply with the "Directive 2002/95/EC of the European Parliament and the Council on the Restriction of Use of certain Hazardous Substances in Electrical and Electronic Equipment" RoHS). SARA-G3 series GSM/GPRS modules are RoHS compliant. No natural rubbers, hygroscopic materials, or materials containing asbestos are employed. Table 30 lists the SARA-G3 series modules main approvals. Certification Scheme SARA-G300 GCF (Global Certification Forum) * PTCRB (PCS Type Certification Review Board) CE (Conformite Europeenne) SARA-G310 * SARA-G340 * * * FCC (US Federal Communications Commission) FCC Identification number * SARA-G350 * * * * * XPYSARAG350 * XPYSARAG350 ISED (Innovation, Science and Economic Development Canada)27 IC certification number * 8595A-SARAG350 * 8595A-SARAG350 Anatel (Agencia Nacional de Telecomunicacoes Brazil) * * A-tick / RCM (Australia Regulatory Compliance Mark) * * EurAsEC (Eurasian Economic Community Certification) * Ukraine Certification * * * * Israel Certification * * China Certification * * NCC (National Communications Commission Taiwan) * * ICASA (Ind. Communications Authority South Africa) * * Vodafone (Network Operator) * * * Orange (Network Operator) * TIM (Telecom Italia Mobile Network Operator) * Rogers (Canadian Network Operator) * Table 30: SARA-G3 series main certification approvals For the complete list of approvals and for specific details on all country and network operators' certifications, see our website (www.u-blox.com) or please contact the u-blox office or sales representative nearest you. 27 Formerly known as IC (Industry Canada) UBX-13000993 - R21 Qualification and approvals Page 35 of 49 SARA-G3 series - Data Sheet 6.2.2 SARA-G340 ATEX and SARA-G350 ATEX SARA-G340 ATEX and SARA-G350 ATEX modules, in addition to the approvals for main certification schemes (see section 6.2.1), are certified as components intended for use in potentially explosive atmospheres compliant to the following standards: IEC 60079-0: 2011 IEC 60079-11: 2011 IEC 60079-26: 2006 The certification number of SARA-G340 ATEX and SARA-G350 ATEX modules according to the ATEX directive 2014/34/EU is: SIQ 13 ATEX 032 U The certification number of SARA-G340 ATEX and SARA-G350 ATEX modules according to the IECEx conformity assessment system is: IECEx SIQ 13.0004U According to the standards listed above, the SARA-G340 ATEX and SARA-G350 ATEX modules are certified with the following marking: Ex II 1G, Ex ia IIC/IIB According to the marking stated above, the SARA-G340 ATEX and SARA-G350 ATEX modules are certified as electrical equipment of: group `II': intended for use in areas with explosive gas atmosphere other than mines susceptible to firedamp category `1G': intended for use in zone 0 hazardous areas, in which explosive atmospheres caused by mixtures of air and gases, vapors or mists are present continuously, for long periods or frequently level of protection `ia': intrinsically safe apparatus with very high level of protection, not capable of causing ignition in normal operation and with the application of one countable fault or a combination of any two countable fault plus those non-countable faults which give the most onerous condition subdivision `IIC/IIB': intended for use in areas where the nature of the explosive gas atmosphere is considered very dangerous based on the Maximum Experimental Safe Gap or the Minimum Ignition Current ratio of the explosive gas atmosphere in which the equipment may be installed (a typical gas is hydrogen), so that the modules are also suitable for applications intended for use in subdivision IIB (typical gas is ethylene) and subdivision IIA (a typical gas is propane) Section 4.2.1 defines the temperature range of use of SARA-G340 ATEX and SARA-G350 ATEX modules. The RF radiating profile of SARA-G340 ATEX and SARA-G350 ATEX modules is compliant to all the applicable 3GPP / ETSI standards, with a maximum of 2 W RF pulse power and 1.15 mJ RF pulse energy according to the GSM/GPRS power class stated in Table 2. Section 9.1 describes the nameplate of SARA-G340 ATEX and SARA-G350 ATEX modules (see Figure 12 and Figure 13). The following maximum input and equivalent parameters must be considered in sub-division IIC: Ui = 3.8 V Ii = 1.6 A (burst) Pi = 2.5 W Ci = 103 F Li = 4.1 H UBX-13000993 - R21 Qualification and approvals Page 36 of 49 SARA-G3 series - Data Sheet The following maximum input and equivalent parameters must be considered in sub-divisions IIB, IIA: Ui = 4.2 V Ii = 2.5 A (burst) Pi = 2.5 W Ci = 103 F Li = 4.1 H For more information about the integration of SARA-G340 ATEX and SARA-G350 ATEX modules in applications intended for use in potentially explosive atmospheres, see the SARA-G3 / SARA-U2 Series System Integration Manual [2]. UBX-13000993 - R21 Qualification and approvals Page 37 of 49 SARA-G3 series - Data Sheet 7 Product handling 7.1 Packaging SARA-G3 series modules are delivered as hermetically sealed, reeled tapes to enable efficient production, production lot set-up and tear-down. For more information about packaging, see the u-blox Package Information Guide [5]. Figure 9: Reeled SARA-G3 series modules 7.1.1 Reels SARA-G3 series modules are deliverable in quantities of 250 pieces on a reel. SARA-G3 series modules are delivered using reel Type B as described in the u-blox Package Information Guide [5]. Parameter Specification Reel Type B Delivery Quantity 250 Table 31: Reel information for SARA-G3 series modules Quantities of less than 250 pieces are also available. Contact u-blox for more information. UBX-13000993 - R21 Product handling Page 38 of 49 SARA-G3 series - Data Sheet 7.1.2 Tapes Figure 10 specifies the dimensions and orientations of the tapes for SARA-G3 series module. Figure 10: Dimensions for SARA-G3 series on tape Parameter Value A0 16.8 B0 26.8 K0 3.2 Table 32: SARA-G3 series tape dimensions (mm) Note 1: 10 sprocket hole pitch cumulative tolerance 0.2. Note 3: A0 and B0 are calculated on a plane at a distance "R" above the bottom of the pocket. Note 2: Pocket position relative to sprocket hole measured as true position of pocket, not pocket hole. 7.2 Moisture sensitivity levels SARA-G3 series modules are Moisture Sensitive Devices (MSD) in accordance to the IPC/JEDEC specification. The Moisture Sensitivity Level (MSL) relates to the packaging and handling precautions required. SARA-G3 series modules are rated at MSL level 4. For more information regarding moisture sensitivity levels, labeling, storage and drying, see the u-blox Package Information Guide [5]. For MSL standard see IPC/JEDEC J-STD-020 (can be downloaded from www.jedec.org). UBX-13000993 - R21 Product handling Page 39 of 49 SARA-G3 series - Data Sheet 7.3 Reflow soldering Reflow profiles are to be selected according to u-blox recommendations (see SARA-G3 / SARA-U2 Series System Integration Manual [2]). Failure to observe these precautions can result in severe damage to the device! 7.4 ESD precautions SARA-G3 series modules contain highly sensitive electronic circuitry and are Electrostatic Sensitive Devices (ESD). Handling SARA-G3 series modules without proper ESD protection may destroy or damage them permanently. SARA-G3 series modules are Electrostatic Sensitive Devices (ESD) and require special ESD precautions typically applied to ESD sensitive components. Table 8 reports the maximum ESD ratings of the SARA-G3 modules. Proper ESD handling and packaging procedures must be applied throughout the processing, handling and operation of any application that incorporates SARA-G3 series modules. ESD precautions should be implemented on the application board where the module is mounted, as described in the SARA-G3 / SARA-U2 Series System Integration Manual [2]. Failure to observe these precautions can result in severe damage to the device! UBX-13000993 - R21 Product handling Page 40 of 49 SARA-G3 series - Data Sheet 8 Default settings Interface Settings Comments UART interface AT interface: enabled AT command interface is by default enabled on the UART physical interface AT+IPR=0 Automatic baud rate detection enabled by default AT+ICF=0 Automatic frame format recognition enabled by default AT&K3 HW flow control enabled AT&S1 DSR line set ON in data mode and set OFF in command mode AT&D1 Upon an ON-to-OFF transition of DTR, the DCE enters online command state and issues an OK result code AT&C1 Circuit 109 changes in accordance with the Carrier detect status; ON if the Carrier is detected, OFF otherwise MUX protocol: disabled Multiplexing mode is by default disabled and it can be configured by AT+CMUX command. SARA-G340 and SARA-G350 modules define the following virtual channels: Channel 0: control channel Channel 1 - 5: AT commands / data connection Channel 6: GNSS tunneling SARA-G300 and SARA-G310 modules define the following virtual channels: Channel 0: control channel Channel 1 - 2: AT commands / data connection AUX UART interface AT interface: disabled AT command interface is by default disabled on the AUX UART physical interface, and it can be configured by AT+USIO command (see the u-blox AT Commands Manual [1]) Power Saving AT+UPSV=0 Disabled Network registration AT+COPS=0 Self network registration Table 33: SARA-G3 series default settings UBX-13000993 - R21 Default settings Page 41 of 49 SARA-G3 series - Data Sheet 9 Labeling and ordering information 9.1 Product labeling The labels of SARA-G3 series modules include important product information as described in this section. Figure 11 illustrates the label of all the SARA-G3 series modules except for SARA-G340 ATEX and SARA-G350 ATEX, and includes: u-blox logo, production lot, Pb-free marking, product Type Number, IMEI number, certification info and production country. xxx-xx FCC ID: XXXXXXXXXX XXXXX-XXXXXXXX IC: ANATEL: XXXXXXXXXX Figure 11: Label of SARA-G3 modules (except for SARA-G340 ATEX and SARA-G350 ATEX) Figure 12 illustrates the label of SARA-G350 ATEX modules, and includes: u-blox logo, production lot, Pb-free marking, product Type Number, IMEI number, ATEX marking with the IECEx and ATEX certificate numbers and category classification, FCC and IC certification numbers and production country. 02X-00 Figure 12: Label of SARA-G350 ATEX modules UBX-13000993 - R21 Labeling and ordering information Page 42 of 49 SARA-G3 series - Data Sheet Figure 13 illustrates the label of SARA-G340 ATEX modules, and includes: u-blox logo, production lot, Pb-free marking, product Type Number, IMEI number, ATEX marking with the IECEx and ATEX certificate numbers and category classification, Notified Body number and production country. 02X-00 SARA-G340 Figure 13: Label of SARA-G340 ATEX modules For information about the approval codes and for all the certificates of compliancy of SARA-G3 series modules, see our website (www.u-blox.com) or contact the u-blox office or sales representative nearest you. 9.2 Explanation of codes Three different product code formats are used. The Product Name is used in documentation such as this data sheet and identifies all u-blox products, independent of packaging and quality grade. The Ordering Code includes options and quality, while the Type Number includes the hardware and firmware versions. Table 34 below details these three different formats: Format Structure Product Name SARA-TGVV Ordering Code SARA-TGVV-TTQ Type Number SARA-TGVV-TTQ-XX Table 34: Product code formats Table 35 explains the parts of the product code. Code Meaning Example SARA Form factor SARA T Platform [G: GSM; U: HSUPA; C: CDMA 1xRTT; N: NB-IoT; R: LTE low data rate (Cat 1 and below); L: LTE high data rate (Cat 3 and above)] G: GSM G Platform generation, e.g. chip or function set [1...9] 3 VV Variant based on the same platform [00...99] 50 TT Product Version [00...99] 00 Q Quality grade / Production site S = professional / made in Austria A = automotive / made in Austria X = ATEX / made in Austria B = professional / made in Brazil S XX Default value is 00 Table 35: Part identification code UBX-13000993 - R21 Labeling and ordering information Page 43 of 49 SARA-G3 series - Data Sheet 9.3 Ordering information Ordering No. Description SARA-G300-00S 2-band GSM/GPRS class 10 module 26.0 x 16.0 x 3.0 mm, 250 pcs/reel SARA-G310-00S 4-band GSM/GPRS class 10 module 26.0 x 16.0 x 3.0 mm, 250 pcs/reel SARA-G340-00S 2-band GSM/GPRS class 10 module Supporting Audio, I2C for u-blox GNSS receivers, AssistNow, CellLocate(R), Embedded TCP/UDP, FTP/HTTP/SMTP, eCall / ERA-GLONASS, Network indication, Antenna supervisor, Jamming detection and other features 26.0 x 16.0 x 3.0 mm, 250 pcs/reel SARA-G340-01S 2-band GSM/GPRS class 10 module Supporting the same feature-set of the "00" product version plus SSL for FTP and HTTP, Multi GNSS Assistance (MGA) server and other features 26.0 x 16.0 x 3.0 mm, 250 pcs/reel SARA-G340-02S 2-band GSM/GPRS class 10 module Supporting the same feature-set of the "01" product version plus second AT interface, improved SSL/TLS, IPv4/IPv6 dual-stack, Bearer Independent Protocol, Network Friendly Mode and other features 26.0 x 16.0 x 2.4 mm, 250 pcs/reel SARA-G340-02X 2-band GSM/GPRS class 10 module Supporting the same feature-set of the "02S" product version ATEX / IECEx certified 26.0 x 16.0 x 2.4 mm, 250 pcs/reel SARA-G350-00S 4-band GSM/GPRS class 10 module Supporting Audio, I2C for u-blox GNSS receivers, AssistNow, CellLocate(R), Embedded TCP/UDP, FTP/HTTP/SMTP, eCall / ERA-GLONASS, Network indication, Antenna supervisor, Jamming detection and other features 26.0 x 16.0 x 3.0 mm, 250 pcs/reel SARA-G350-00X 4-band GSM/GPRS class 10 module Supporting the same feature-set of the "00S" product version ATEX / IECEx certified 26.0 x 16.0 x 3.0 mm, 250 pcs/reel SARA-G350-01S 4-band GSM/GPRS class 10 module Supporting the same feature-set of the "00" product version plus SSL for FTP and HTTP, Multi GNSS Assistance (MGA) server and other features 26.0 x 16.0 x 3.0 mm, 250 pcs/reel SARA-G350-01B 4-band GSM/GPRS class 10 module Supporting the same feature-set of the "01S" product version Made in Brazil 26.0 x 16.0 x 3.0 mm, 250 pcs/reel SARA-G350-02S 4-band GSM/GPRS class 10 module Supporting the same feature-set of the "01" product version plus second AT interface, improved SSL/TLS, IPv4/IPv6 dual-stack, Bearer Independent Protocol, Network Friendly Mode and other features 26.0 x 16.0 x 2.4 mm, 250 pcs/reel SARA-G350-02X 4-band GSM/GPRS class 10 module Supporting the same feature-set of the "02S" product version ATEX / IECEx certified 26.0 x 16.0 x 3.0 mm, 250 pcs/reel Table 36: Product ordering codes UBX-13000993 - R21 Labeling and ordering information Page 44 of 49 SARA-G3 series - Data Sheet Appendix A Glossary Abbreviation Definition ADC Analog to Digital Converter AT AT Command Interpreter Software Subsystem, or attention ATEX Atmospheres Explosive BB Base-Band BER Bit Error Rate DCE Data Communication Equipment DDC Display Data Channel (I2C compatible) Interface DL Down-link (Reception) Driver Class Output Driver Class: see Table 22 for definition DRX Discontinuous Reception DTE Data Terminal Equipment ERS External Reset Input Signal GDI Generic Digital Interfaces (power domain) GND Ground GNSS Global Navigation Satellite System GPIO General Purpose Input Output GPRS General Packet Radio Service GPS Global Positioning System GSM Global System for Mobile Communication H High logic digital level HBM Human Body Model IC Inter-Integrated Circuit Interface IS Inter-IC Sound Interface L Low logic digital level LGA Land Grid Array N/A Not Applicable OD Open Drain PA Power Amplifier PCN / IN Product Change Notification / Information Note PD Pull-Down PMU Power Management Unit POS Power-On Input Signal PU Pull-Up PU/PD Class Pull-Up / Pull-Down Class: see Table 22 for definition RMC Reference Measurement Channel SIM Subscriber Identity Module SPI Serial Peripheral Interface T Tristate (Output of the pin set to tri-state, i.e. high impedance state) T/PD Tristate with internal active Pull-Down enabled T/PU Tristate with internal active Pull-Up enabled TBD To Be Defined UART Universal Asynchronous Receiver-Transmitter serial interface 2 2 UBX-13000993 - R21 Appendix Page 45 of 49 SARA-G3 series - Data Sheet Abbreviation Definition UL Up-link (Transmission) USB Universal Serial Bus interface Table 37: Explanation of the abbreviations and terms used UBX-13000993 - R21 Appendix Page 46 of 49 SARA-G3 series - Data Sheet Related documents [1] [2] [3] [4] [5] [6] [7] [8] u-blox AT Commands Manual, Doc. No. UBX-13002752 u-blox SARA-G3 / SARA-U2 Series System Integration Manual, Doc. No. UBX-13000995 u-blox GNSS Implementation Application Note, Doc. No. UBX-13001849 u-blox Mux Implementation Application Note for cellular modules, Doc. No. UBX-13001887 u-blox Package Information Guide, Doc. No. UBX-14001652 u-blox Android RIL Production delivery Application note, Doc. No. UBX-13002041 u-blox Windows Embedded RIL Production delivery Application note, Doc. No. UBX-13002043 ITU-T Recommendation V24, 02-2000. List of definitions for interchange circuits between Data Terminal Equipment (DTE) and Data Connection Equipment (DCE) [9] 3GPP TS 27.007 - Technical Specification Group Core Network and Terminals; AT command set for User Equipment (UE) [10] 3GPP TS 27.005 - Technical Specification Group Terminals; Use of Data Terminal Equipment - Data Circuit terminating Equipment (DTE-DCE) interface for Short Message Services (SMS) and Cell Broadcast Service (CBS) [11] 3GPP TS 27.010 - Terminal Equipment to User Equipment (TE-UE) multiplexer protocol [12] 3GPP TS 26.267 - Technical Specification Group Services and System Aspects; eCall Data Transfer; In-band modem solution; General description [13] GSM Association - Official Document CLP.03 - IoT Device Connection Efficiency Guidelines For regular updates to u-blox documentation and to receive product change notifications, register on our homepage (www.u-blox.com). UBX-13000993 - R21 Related documents Page 47 of 49 SARA-G3 series - Data Sheet Revision history Revision Date Name Comments - Jun. 22, 2012 lpah / sses Initial release 1 Sep. 05, 2012 sses Corrected module pin numbering and dimensions 2 Oct. 19, 2012 sses Added ESD immunity rating for ANT pin; Added current consumption ratings 3 Nov. 07, 2012 sses Added the technical description of SARA-G300 and SARA-G310 modules Updated current consumption ratings 4 Mar. 08, 2013 lpah / sses Updated status to Advance Information 5 Apr. 12, 2013 lpah Updated status to Preliminary 6 May 23, 2013 lpah 7 May 27, 2013 lpah Updated status to Objective Specification; CSD supported by SARA-G300 / SARA-G310 GPRS multi-slot class 10 supported by SARA-G300 / SARA-G310 A Jul. 05, 2013 sses Last revision with docu number GSM.G2-HW-12001 Updated status to Advance Information A1 Jul. 31, 2013 lpah R11 23-Jan-2014 lpah Added the technical description of SARA-G350 ATEX modules; Added description of 32K_OUT pin for SARA-G300 / SARA-G310; Updated current consumption ratings Updated status to Preliminary SIM detection not supported by SARA-G300 and SARA-G310 modules Last revision with old document number GSM.G2-HW-12001 Updated status to Objective Specification Extended the document applicability to SARA-G340 modules Updated document status to Advance Information. Extended the document applicability to the SARA-G340-01S, SARA-G350-01S and SARA-G350-01B modules versions. Updated information about RIL and USSD. R12 30-Jun-2014 mrod R13 17-Oct-2014 mrod Updated document status to Early Preliminary Information. R14 14-May-2015 lpah Updated document status to Preliminary Information. R15 15-Dec-2015 sses Updated allowed baud rates for AT interface Reverted status to Advanced Information sses Extended the document applicability to SARA-G3 modules "02" product versions Updated document status to Early Preliminary Information. Updated current consumption ratings with AT+UPSV=0. R16 29-Jan-2016 Added detailed VCC current consumption characteristics and enlarged VCC supply extended operating voltage range for SARA-G3 modules "02" product versions. R17 12-May-2016 sses R18 21-Jul-2016 lpah Extended the document applicability to SARA-G340 ATEX module R19 24-Apr-2017 lpah R20 03-Aug-2017 lpah "Disclosure restriction" replaces "Document status" on page 2 and document footer Extended document applicability to SARA-G350-02X Extended the document SARA-G310-00S-01. applicability to SARA-G300-00S-01 / Updated the ATEX label. Updated label and approvals information R21 27-Mar-2018 UBX-13000993 - R21 lpah Extended document applicability to SARA-G340-02S-01, SARA-G340-02X-01, SARA-G350-02S-01, SARA-G350-02X-01 Revision history Page 48 of 49 SARA-G3 series - Data Sheet Contact For complete contact information, visit us at www.u-blox.com. u-blox Offices North, Central and South America u-blox America, Inc. Phone: E-mail: +1 703 483 3180 info_us@u-blox.com Regional Office West Coast: Phone: E-mail: Headquarters Europe, Middle East, Africa u-blox AG Phone: +41 44 722 74 44 E-mail: info@u-blox.com Support: support@u-blox.com +1 408 573 3640 info_us@u-blox.com u-blox Singapore Pte. Ltd. Phone: +65 6734 3811 E-mail: info_ap@u-blox.com Support: support_ap@u-blox.com Regional Office Australia: Phone: +61 2 8448 2016 E-mail: info_anz@u-blox.com Support: support_ap@u-blox.com Technical Support: Phone: E-mail: Asia, Australia, Pacific +1 703 483 3185 support@u-blox.com Regional Office China (Beijing): Phone: +86 10 68 133 545 E-mail: info_cn@u-blox.com Support: support_cn@u-blox.com Regional Office China (Chongqing): Phone: +86 23 6815 1588 E-mail: info_cn@u-blox.com Support: support_cn@u-blox.com Regional Office China (Shanghai): Phone: +86 21 6090 4832 E-mail: info_cn@u-blox.com Support: support_cn@u-blox.com Regional Office China (Shenzhen): Phone: +86 755 8627 1083 E-mail: info_cn@u-blox.com Support: support_cn@u-blox.com Regional Office India: Phone: +91 80 405 092 00 E-mail: info_in@u-blox.com Support: support_in@u-blox.com Regional Office Japan (Osaka): Phone: +81 6 6941 3660 E-mail: info_jp@u-blox.com Support: support_jp@u-blox.com Regional Office Japan (Tokyo): Phone: +81 3 5775 3850 E-mail: info_jp@u-blox.com Support: support_jp@u-blox.com Regional Office Korea: Phone: +82 2 542 0861 E-mail: info_kr@u-blox.com Support: support_kr@u-blox.com Regional Office Taiwan: Phone: +886 2 2657 1090 E-mail: info_tw@u-blox.com Support: support_tw@u-blox.com UBX-13000993 - R21 Contact Page 49 of 49