SARA-G3 series
Dual and quad-band GSM/GPRS modules
Data Sheet
Abstract
Technical data sheet describing SARA-G3 series GSM/GPRS cellular modules. These modules are
complete and cost efficient solutions offering two-band or quad-band GSM/GPRS voice and/or data
transmission technology in a compact form factor.
www.u-blox.com
www.u-blox.com
UBX-13000993 - R21
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Page 2 of 49
Document Information
Title
SARA-G3 series
Subtitle
Dual and quad-band GSM/GPRS modules
Document type
Data Sheet
Document number
UBX-13000993
Revision and date
R21
27-Mar-2018
Disclosure restriction
Corresponding content status
Draft
For functional testing. Revised and supplementary data will be published
later.
Objective Specification
Target values. Revised and supplementary data will be published later.
Advance Information
Data based on early testing. Revised and supplementary data will be
published later.
Early Prod. Information
Data from product verification. Revised and supplementary data may be
published later.
Production Information
Final product specification.
This document applies to the following products:
Product name
Type number
Modem
version
Application
version
PCN reference
Product status
SARA-G300
SARA-G300-00S-01
08.58
A01.01
UBX-16010060
Mass Production
SARA-G310
SARA-G310-00S-01
08.58
A01.01
UBX-16010060
Mass Production
SARA-G340
SARA-G340-00S-00
08.49
N.A.
UBX-14000382
End of Life
SARA-G340-01S-00
08.70
A00.02
UBX-14039634
End of Life
SARA-G340-02S-00
08.90
A00.02
UBX-16001074
End of Life
SARA-G340-02S-01
08.90
A01.13
UBX-18008871
Mass Production
SARA-G340 ATEX
SARA-G340-02X-00
08.90
A00.02
UBX-16017766
End of Life
SARA-G340-02X-01
08.90
A01.13
UBX-18008871
Mass Production
SARA-G350
SARA-G350-00S-00
08.49
N.A.
GSM.G2-TN-13002
End of Life
SARA-G350-01S-00
08.70
A00.02
UBX-14039634
End of Life
SARA-G350-01B-00
08.70
A00.02
UBX-14039634
End of Life
SARA-G350-02S-00
08.90
A00.02
UBX-16001074
End of Life
SARA-G350-02S-01
08.90
A01.13
UBX-18008871
Mass Production
SARA-G350 ATEX
SARA-G350-00X-00
08.49
N.A.
GSM.G2-TN-13002
End of Life
SARA-G350-02X-00
08.90
A00.02
UBX-17048555
End of Life
SARA-G350-02X-01
08.90
A01.13
UBX-18008871
Mass Production
u-blox or third parties may hold intellectual property rights in the products, names, logos and designs included in this
document. Copying, reproduction, modification or disclosure to third parties of this document or any part thereof is only
permitted with the express written permission of u-blox.
The information contained herein is provided “as is” and u-blox assumes no liability for its use. No warranty, either express or
implied, is given, including but not limited to, with respect to the accuracy, correctness, reliability and fitness for a particular
purpose of the information. This document may be revised by u-blox at any time without notice. For the most recent
documents, visit www.u-blox.com.
Copyright © u-blox AG.
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Page 3 of 49
Contents
Document Information ................................................................................................................................ 2
Contents .......................................................................................................................................................... 3
1 Functional description ......................................................................................................................... 5
1.1 Overview ........................................................................................................................................................ 5
1.2 Product features ......................................................................................................................................... 5
1.3 Block diagram .............................................................................................................................................. 6
1.4 Product description .................................................................................................................................... 7
1.5 AT command support ................................................................................................................................ 8
1.6 Supported features .................................................................................................................................... 8
2 Interfaces ............................................................................................................................................... 12
2.1 Power management .................................................................................................................................. 12
2.1.1 Module supply input (VCC) .............................................................................................................. 12
2.1.2 RTC supply input/output (V_BCKP) ............................................................................................... 12
2.1.3 Digital I/O interfaces supply output (V_INT) ................................................................................ 12
2.2 Antenna ........................................................................................................................................................ 12
2.2.1 Antenna RF interface (ANT) ............................................................................................................ 12
2.2.2 Antenna detection (ANT_DET) ....................................................................................................... 12
2.3 System functions ...................................................................................................................................... 13
2.3.1 Module power-on (PWR_ON) .......................................................................................................... 13
2.3.2 Module power-off .............................................................................................................................. 13
2.3.3 Module reset (RESET_N) ................................................................................................................. 13
2.3.4 External 32 kHz signal input (EXT32K) ........................................................................................ 13
2.3.5 Internal 32 kHz signal output (32K_OUT) .................................................................................... 14
2.4 SIM ............................................................................................................................................................... 14
2.4.1 (U)SIM interface ................................................................................................................................ 14
2.4.2 SIM card detection (SIM_DET) ....................................................................................................... 14
2.5 Serial interfaces ........................................................................................................................................ 14
2.5.1 Asynchronous serial interface (UART) ......................................................................................... 15
2.5.2 Auxiliary asynchronous serial interface (AUX UART) ................................................................ 16
2.5.3 DDC (I2C compatible) interface ...................................................................................................... 16
2.6 Audio ............................................................................................................................................................. 17
2.7 GPIO .............................................................................................................................................................. 17
3 Pin definition ......................................................................................................................................... 18
3.1 Pin assignment .......................................................................................................................................... 18
4 Electrical specifications ................................................................................................................... 23
4.1 Absolute maximum rating ....................................................................................................................... 23
4.1.1 Maximum ESD ................................................................................................................................... 23
4.2 Operating conditions ................................................................................................................................ 24
4.2.1 Operating temperature range ........................................................................................................ 24
4.2.2 Module thermal resistance ............................................................................................................. 24
4.2.3 Supply/Power pins ............................................................................................................................ 25
4.2.4 Current consumption ....................................................................................................................... 25
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Page 4 of 49
4.2.5 RF performance ................................................................................................................................ 27
4.2.6 ANT_DET pin ...................................................................................................................................... 27
4.2.7 PWR_ON pin ....................................................................................................................................... 28
4.2.8 RESET_N pin ...................................................................................................................................... 28
4.2.9 EXT32K pin ......................................................................................................................................... 28
4.2.10 SIM pins .............................................................................................................................................. 29
4.2.11 Generic Digital Interfaces pins ....................................................................................................... 29
4.2.12 DDC (I2C) pins ..................................................................................................................................... 32
4.2.13 Audio pins ........................................................................................................................................... 32
5 Mechanical specifications ............................................................................................................... 34
6 Qualification and approvals ............................................................................................................. 35
6.1 Reliability tests .......................................................................................................................................... 35
6.2 Approvals .................................................................................................................................................... 35
6.2.1 SARA-G3 series ................................................................................................................................. 35
6.2.2 SARA-G340 ATEX and SARA-G350 ATEX .................................................................................. 36
7 Product handling ................................................................................................................................. 38
7.1 Packaging ................................................................................................................................................... 38
7.1.1 Reels .................................................................................................................................................... 38
7.1.2 Tapes ................................................................................................................................................... 39
7.2 Moisture sensitivity levels ....................................................................................................................... 39
7.3 Reflow soldering ........................................................................................................................................ 40
7.4 ESD precautions ........................................................................................................................................ 40
8 Default settings ................................................................................................................................... 41
9 Labeling and ordering information ............................................................................................... 42
9.1 Product labeling ......................................................................................................................................... 42
9.2 Explanation of codes ................................................................................................................................ 43
9.3 Ordering information ................................................................................................................................ 44
Appendix ....................................................................................................................................................... 45
Related documents .................................................................................................................................... 47
Revision history .......................................................................................................................................... 48
Contact .......................................................................................................................................................... 49
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Functional description Page 5 of 49
1 Functional description
1.1 Overview
SARA-G3 series modules are versatile 2.5G GSM/GPRS cellular modules in a miniature LGA (Land
Grid Array) form factor. Featuring low power consumption, the SARA-G3 series combines baseband,
RF transceiver, power management unit, and power amplifier in a single, easy-to-integrate solution.
SARA-G3 modules provide a fully qualified and certified solution, reducing cost and enabling short
time to market. These modules are ideally suited for M2M applications such as: Automatic Meter
Reading (AMR), Remote Monitoring Automation and Control (RMAC), surveillance and security,
eCall, road pricing, asset tracking, fleet management, anti-theft systems and Point of Sales (PoS)
terminals.
SARA-G340 (dual-band) and SARA-G350 (quad-band) are full feature GSM/GPRS cellular modules
with a comprehensive feature set including an extensive set of internet protocols. The modules also
provide fully integrated access to u-blox GNSS positioning chips and modules, with embedded A-
GPS (AssistNow Online and AssistNow Offline) functionality. Any host processor connected to the
cellular module through a single serial port can control both the cellular module and the positioning
chip / module.
SARA-G310 (quad-band) and SARA-G300 (dual-band) are GSM/GPRS cellular modules targeted for
high volume cost-sensitive applications, providing GSM/GPRS functionalities with a reduced set of
additional features to minimize the customer’s total cost of ownership. The SARA-G3 series’
compact form factor and LGA pads allow fully automated assembly with standard pick & place and
reflow soldering equipment for cost-efficient, high-volume production.
1.2 Product features
Module
Data
Rate
Bands
Positioning
Interfaces
Audio
Features
Grade
GPRS multi-slot class 10
GSM/GPRS 4-band
GSM/GPRS 2-band 900/1800
GNSS receiver
GNSS via modem
AssistNow Software
CellLocate®
UART
SPI
USB 2.0
GPIO
DDC for u-blox GNSS receivers
Analog Audio
Digital Audio
Network indication
Antenna supervisor
Jamming detection
Embedded TCP/UDP stack
Embedded FTP, HTTP, SMTP
Embedded SSL
Dual stack IPv4/IPv6
FW update via serial interface
eCall / ERA-GLONASS
Low power idle-mode
ATEX certification
Standard
Professional
Automotive
SARA-G300
2
SARA-G310
2
SARA-G340
2
4
SARA-G340 ATEX
2
4
SARA-G350
2
4
SARA-G350 ATEX
2
4
= supported by all product versions
= supported by product versions “01” onwards
= 32 kHz signal at EXT32K input is required for low power idle-mode
= supported by product versions “02” onwards
Table 1: SARA-G3 series summary of modules’ main features
1
1
SARA-G340 ATEX and SARA-G350 ATEX modules provide the same feature set as the SARA-G340 and SARA-G350 modules
respectively, with the additional certification for use in potentially explosive atmospheres. Unless otherwise specified, SARA-
G340 refers to all SARA-G340 ATEX and SARA-G340 modules; in the same way SARA-G350 refers to both SARA-G350 ATEX
and SARA-G350 modules.
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Functional description Page 6 of 49
1.3 Block diagram
Memory
V_BCKP (RTC)
V_INT (I/O)
32 kHz
26 MHz
RF
Transceiver
Power
Management
Baseband
ANT SAW
Filter
Switch
PA
VCC (Supply)
32 kHz
Auxiliary UART
SIM card
UART
Power-On
Reset
Figure 1: SARA-G300 and SARA-G310 block diagram
Memory
V_BCKP (RTC)
V_INT (I/O)
26 MHz 32.768 kHz
RF
Transceiver
Power
Management
Baseband
ANT SAW
Filter
Switch
PA
VCC (Supply)
Auxiliary UART
DDC (for GPS/GNSS)
SIM card detection
SIM card
UART
Power-On
Reset
Digital Audio
Analog Audio
GPIO
Antenna detection
Figure 2: SARA-G340 and SARA-G350 block diagram
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Functional description Page 7 of 49
1.4 Product description
Item
SARA-G300
SARA-G310
SARA-G340
SARA-G350
GSM/GPRS
Protocol
Stack
3GPP Release 99
3GPP Release 99
3GPP Release 99
3GPP Release 99
Mobile
Station
Class
Class B 2
Class B 2
Class B 2
Class B 2
GSM/GPRS
Bands
E-GSM 900 MHz
DCS 1800 MHz
GSM 850 MHz
E-GSM 900 MHz
DCS 1800 MHz
PCS 1900 MHz
E-GSM 900 MHz
DCS 1800 MHz
GSM 850 MHz
E-GSM 900 MHz
DCS 1800 MHz
PCS 1900 MHz
GSM/GPRS
Power Class
Class 4 (33 dBm)
for 900 band
Class 1 (30 dBm)
for 1800 band
Class 4 (33 dBm)
for 850/900 bands
Class 1 (30 dBm)
for 1800/1900 bands
Class 4 (33 dBm)
for 900 band
Class 1 (30 dBm)
for 1800 band
Class 4 (33 dBm)
for 850/900 bands
Class 1 (30 dBm)
for 1800/1900 bands
Packet
Switched
Data Rate
GPRS multi-slot class 10 3
Coding scheme CS1-CS4
Up to 85.6 kb/s DL 4
Up to 42.8 kb/s UL 4
GPRS multi-slot class 10 3
Coding scheme CS1-CS4
Up to 85.6 kb/s DL 4
Up to 42.8 kb/s UL 4
GPRS multi-slot class 10 3
Coding scheme CS1-CS4
Up to 85.6 kb/s DL 4
Up to 42.8 kb/s UL 4
GPRS multi-slot class 10 3
Coding scheme CS1-CS 4
Up to 85.6 kb/s DL 4
Up to 42.8 kb/s UL 4
Circuit
Switched
Data Rate
Up to 9.6 kb/s DL/UL 4
Transparent mode
Non-transparent mode
Up to 9.6 kb/s DL/UL 4
Transparent mode
Non-transparent mode
Up to 9.6 kb/s DL/UL 4
Transparent mode
Non-transparent mode
Up to 9.6 kb/s DL/UL 4
Transparent mode
Non-transparent mode
Network
Operation
Modes
I to III
I to III
I to III
I to III
Table 2: SARA-G3 series GSM/GPRS characteristics summary
The network automatically configures the channel encoding used by the module, depending on
conditions and the quality of the radio link between cell phone and base station. If the channel is very
noisy, the network may use the most robust coding scheme (CS-1) to ensure higher reliability. If the
channel provides good conditions, the network can use the least robust but fastest coding scheme
(CS-4) to obtain optimum speed.
2
Device can be attached to both GPRS and GSM services (i.e. Packet Switch and Circuit Switch mode) using one service at a time.
3
GPRS multi-slot class 10 implies a maximum of 4 slots in DL (reception) and 2 slots in UL (transmission) with 5 slots in total.
4
The maximum bit rate of the module depends on the current network settings.
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Functional description Page 8 of 49
Basic features
Supplementary services
Short Message Service (SMS)
Display of Called Number 5
Call Hold/Resume (HOLD) 5
Text and PDU mode supported
Indication of Call Progress Signals 5
Call Waiting (CW) 5
Mobile-Originating SMS (MO SMS)
Country/PLMN Indication
Call Forwarding (CFU, CFB, CFNRy, CFNRc) 5
Mobile-Terminating SMS (MT SMS)
Country/PLMN Selection
Call Barring (BAOC, BOIC, BOIC-exHC, BAIC,
BIC_Roam) 5
SMS indication and
acknowledgement
International Access Function 5
Call Deflection (CD) 5
SMS Cell Broadcast (CBS)
Service Indicator
Explicit Call Transfer (ECT) 5
SMS during circuit-switched calls 5
TBD
Emergency Calls Capabilities 5
Multi-Party (MTPY) 5
SMS over CSD TBD
Dual Tone Multi Frequency (DTMF) 5
Calling Line Identification Presentation (CLIP)5
SMS over PSD
Subscription Identity Management
Calling Line Identification Restriction (CLIR)5
SMS storage on SIM
Service Provider Indication
Connected Line Identification Presentation (CoLP) 5
SMS storage on module memory 5
TBD
Abbreviated Dialing 5
Connected Line Identification Restriction (CoLR) 5
Concatenated SMS
Fixed Number Dialing 5
Unstructured Supplementary Services Data (USSD)
SMS Classes 0, 1, 2, 3 and classless
TBD
Barring of Dialed Numbers 5
Advice of Charge Charging (AoCC, AoCI)5
SIM Application Toolkit 5
Calling Name Presentation (CNAP) 5
ME-SIM lock
Network Identify and Time Zone (NITZ)
Table 3: SARA-G3 series mobile stations: basic features, supplementary services, and SMS service summary
6
1.5 AT command support
The module supports AT commands according to 3GPP standards: TS 27.007 [9], 27.005 [10],
27.010 [11], and the u-blox AT command extension.
For the complete list of the supported AT commands and their syntax, see the document u-blox
AT Commands Manual [1].
RIL (Radio Interface Layer) software for Android and Embedded Windows is available for SARA-G3
modules free of charge; see the Android RIL Production delivery [6] and the Windows Embedded RIL
Production delivery [7] application notes for more information.
1.6 Supported features
Table 4 describes the main features supported by SARA-G3 modules. For more details, see the
SARA-G3 / SARA-U2 Series System Integration Manual [2] and the u-blox AT commands manual [1].
Feature
Module
Description
Network Indication
SARA-G340 /
SARA-G350
GPIO configured to indicate the network status: registered home network,
registered roaming, voice or data call enabled, no service.
The network indication feature can be enabled through a custom AT command
(see the u-blox AT commands manual [1], +UGPIOC AT command).
5
Supported only by SARA-G340 and SARA-G350 modules
6
These functionalities are supported via AT commands (for more details see the u-blox AT Commands Manual [1]).
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Functional description Page 9 of 49
Feature
Module
Description
Antenna Detection
SARA-G340 /
SARA-G350
The ANT_DET pin provides antenna presence detection capability, evaluating
the resistance from the ANT pin to GND by means of an external antenna
detection circuit implemented on the application board.
The antenna detection feature can be enabled through a custom AT command
(see the u-blox AT commands manual [1], +UANTR AT command).
Jamming detection
SARA-G340 /
SARA-G350
Detects “artificial” interference that obscures the operator’s carriers providing
access to the GSM service and reports the start and stop of such conditions to
the application processor (AP). The AP can react appropriately, e.g. by
switching off the radio transceiver to reduce power consumption and
monitoring the environment at constant periods.
The jamming detection feature can be enabled and configured through a
custom AT command (see the u-blox AT commands manual [1], +UCD AT
command).
Jamming condition
indication over GPIO 7
SARA-G340 /
SARA-G350
The jamming condition can be reported by a GPIO of the module as enabled and
configured through a custom AT commands (see the u-blox AT commands
manual [1], +UCD and +UGPIOC AT commands).
Second AT interface 7
SARA-G340 /
SARA-G350
AT command mode available on both the UART and the Auxiliary UART
interfaces.
See the u-blox AT commands manual [1], +USIO AT command for further details
regarding serial interfaces configuration selection.
Embedded TCP/IP and
UDP/IP
SARA-G340 /
SARA-G350
Embedded TCP/IP and UDP/IP stack including direct link mode for TCP and UDP
sockets.
The sockets can be configured in Direct Link mode to establish a transparent
end-to-end communication with an already connected TCP or UDP socket via
serial interface.
FTP, FTPS 8
SARA-G340 /
SARA-G350
File Transfer Protocol as well as Secure File Transfer Protocol (SSL encryption
of FTP control channel) functionalities are supported via AT commands.
HTTP, HTTPS 8
SARA-G340 /
SARA-G350
Hyper-Text Transfer Protocol as well as Secure Hyper-Text Transfer Protocol
(SSL encryption) functionalities are supported via AT commands. HEAD, GET,
POST, DELETE and PUT operations are available. Up to 4 client contexts can be
simultaneously used.
Embedded TLS 1.2 7
SARA-G340 /
SARA-G350
With the support of X.509 certificates, Embedded TLS 1.2 provides server and
client authentication, data encryption, data signature and enables TCP/IP
applications like HTTPS and FTPS to communicate over a secured and trusted
connection.
The feature can be configured and enabled by +USECMNG and +USECPRF AT
commands.
IPv4/IPv6 dual-stack 9
SARA-G340 /
SARA-G350
Capability to move between IPv4 and dual stack network infrastructures. IPv4
and IPv6 addresses can be used.
GPS/GNSS via Modem
SARA-G340 /
SARA-G350
Full access to u-blox positioning chips and modules is available through a
dedicated DDC (I2C) interface. A single serial port from any host processor can
control both the cellular module and the positioning chips / modules.
For more details, see the GNSS Implementation Application Note [3].
AssistNow Software
SARA-G340 /
SARA-G350
Embedded AssistNow Online and AssistNow Offline clients to provide full
developed to provide better GNSS performance and faster Time-to-First-Fix.
The clients can be enabled / disabled with an AT command.
CellLocate®
SARA-G340 /
SARA-G350
Enables the estimation of device position based on the parameters of the
mobile network cells visible to the specific device based on the CellLocate®
database:
Normal scan: parameters of the visible home network cells are only sent
Deep scan: parameters of all surrounding cells of all mobile operators are
sent
CellLocate® is implemented using a set of AT commands for CellLocate® service
configuration and position request.
7
Supported by “02” product versions onwards
8
FTPS and HTTPS supported by “01” product versions onwards
9
Supported by “02” product versions onwards
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Functional description Page 10 of 49
Feature
Module
Description
Hybrid Positioning
SARA-G340 /
SARA-G350
Provides the module’s current position using a u-blox positioning chip or module
or the estimated position from CellLocate®, depending on which positioning
method provides the best and fastest solution according to the user
configuration.
Hybrid positioning is implemented through a set of AT commands that allow
the configuration and the position request.
Firmware update Over
AT commands (FOAT)
All
Firmware module upgrade over the UART interface using AT command.
BIP 9
SARA-G340 /
SARA-G350
Bearer Independent Protocol for Over-the-Air SIM provisioning. The data
transfer to/from the SIM uses either an already active PDP context or a new
PDP context established with the APN provided by the SIM card.
In-Band modem
SARA-G340 /
SARA-G350
In-Band modem solution for eCall and ERA-GLONASS emergency call
applications over cellular networks implemented according to the 3GPP TS
26.267 specification [12].
When activated, the in-vehicle eCall / ERA-GLONASS system (IVS) creates an
emergency call carrying both voice and data (including vehicle position data)
directly to the nearest Public Safety Answering Point (PSAP) to determine
whether rescue services should be dispatched to the known position.
DTMF decoder
SARA-G340 /
SARA-G350
During a voice call, the Dual-Tone Multi-Frequency detector analyses the RX
speech (coming from remote party). The detected DTMF symbols can be
output via related URC.
For more details, see the +UDTMFD AT command.
Automatic selection of
authentication type 9
SARA-G340 /
SARA-G350
Automatic selection of authentication type during PDP context activation. The
module will sequentially try different authentication protocols
(none/CHAP/PAP) until the authentication succeeds.
The feature can be enabled through the +UPSD and +UAUTHREQ AT
commands.
Signal quality report
for PS calls 9
SARA-G340 /
SARA-G350
The quality of the GPRS UL and/or DL connection is returned by the AT+CSQ
command.
Network Friendly
Mode 9
SARA-G340 /
SARA-G350
When the Network Friendly Mode is enabled, the module reacts to service
request denials by using time-spaced, randomized or delayed retry schemes
according to GSMA IoT Device Connection Efficiency Guidelines [13].
The feature can be enabled through the +UNFM, +UNFMCONF, +URPM AT
commands.
Smart Temperature
Supervisor
SARA-G340 /
SARA-G350
Constant monitoring of the module board temperature:
Warning notification when the temperature approaches an upper or lower
predefined threshold
Shutdown notified and forced when the temperature value is outside the
specified range (shutdown suspended in case of an emergency call in
progress)
The Smart Temperature Supervisor feature can be enabled or disabled through
an AT command (see the u-blox AT commands manual [1], +USTS AT
command)
The sensor measures board temperature inside the shields, which can
differ from ambient temperature.
Power saving
All
The power saving configuration is by default disabled, but it can be configured
using an AT command. When power saving is enabled, the module
automatically enters the low power idle-mode whenever possible, reducing
current consumption.
During idle-mode, the module processor core runs with the RTC 32 kHz
reference clock, which is generated by:
The internal 32 kHz oscillator, in case of SARA-G340 and SARA-G350
modules
The 32 kHz signal provided at the EXT32K input pin, in case of SARA-G300
and SARA-G310 modules
For more details, see the SARA-G3 / SARA-U2 Series System Integration
Manual [2] and the u-blox AT commands manual [1], +UPSV AT command.
Table 4: SARA-G3 series’ main supported features
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Functional description Page 11 of 49
u-blox is extremely mindful of user privacy. When a position is sent to the CellLocate® server,
u-blox is unable to track the SIM used or the specific device.
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Interfaces Page 12 of 49
2 Interfaces
2.1 Power management
2.1.1 Module supply input (VCC)
SARA-G3 modules must be supplied through the three VCC pins by a DC power supply. Voltages
must be stable: during operation, the current drawn from VCC can vary by some order of magnitude,
especially due to the surging consumption profile of the GSM system (described in the SARA-G3 /
SARA-U2 Series System Integration Manual [2]). It is important that the system power supply
circuit is able to support peak power.
SARA-G3 modules product versions “02” onwards provide separate supply inputs over the three
VCC pins:
VCC pins #52 and #53 represent the supply input for the internal RF power amplifier, demanding
most of the total current drawn of the module when RF transmission is enabled during a
voice/data call
VCC pin #51 represents the supply input for the internal baseband Power Management Unit and
the internal transceiver, demanding minor part of the total current drawn of the module when RF
transmission is enabled during a voice/data call
2.1.2 RTC supply input/output (V_BCKP)
V_BCKP is the Real Time Clock (RTC) supply of SARA-G3 modules. When VCC voltage is within the
valid operating range, the internal Power Management Unit (PMU) supplies the RTC and the same
supply voltage is available on V_BCKP pin. If the VCC voltage is under the minimum operating limit
(e.g. during not powered mode), the V_BCKP pin can externally supply the RTC.
2.1.3 Digital I/O interfaces supply output (V_INT)
SARA-G3 modules provide an internally generated supply rail output for digital interfaces (V_INT).
This can be used in place of an external discrete regulator to supply pull-up resistors on the DDC
interface. This optimizes the bill of material for various applications, e.g. with u-blox positioning
modules operating at 1.8 V.
2.2 Antenna
2.2.1 Antenna RF interface (ANT)
The ANT pin has an impedance of 50 and provides the RF antenna interface of SARA-G3 modules.
2.2.2 Antenna detection (ANT_DET)
The ANT_DET pin is an Analog to Digital Converter (ADC) input provided only by SARA-G340 and
SARA-G350 modules to sense the antenna presence (as optional feature), evaluating the resistance
from the ANT pin to GND by means of an external antenna detection circuit implemented on the
application board. For more details, see the SARA-G3 / SARA-U2 Series System Integration Manual
[2] and the u-blox AT Commands Manual [1], +UANTR.
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Interfaces Page 13 of 49
2.3 System functions
2.3.1 Module power-on (PWR_ON)
SARA-G3 modules can be switched on in one of the following ways:
Rising edge on the VCC pin to a valid voltage for module supply, i.e. applying module supply
Low level on the PWR_ON input pin, i.e. forcing the pin (normally high with external pull-up) to
a low level for a valid time period (see section 4.2.7). The PWR_ON pin requires an external
pull-up resistor to set its value to logic high and may not be left floating
RTC alarm, i.e. pre-programmed scheduled time (see the u-blox AT Commands Manual [1],
AT+CALA)
SARA-G300 and SARA-G310 cannot be switched on with RTC alarm.
2.3.2 Module power-off
SARA-G3 modules can be properly switched off, with storage of current settings and network
detach, by:
AT+CPWROFF command
An abrupt under-voltage shutdown occurs on SARA-G3 modules when the VCC supply drops below
the extended operating range minimum limit, but in this case it is not possible to perform the
storing of the current parameter settings in the module’s non-volatile memory as well as the proper
network detach.
An over-temperature or an under-temperature shutdown occurs on SARA-G3 modules when the
temperature measured within the cellular module reaches the dangerous area, if the optional Smart
Temperature Supervisor feature is enabled and configured by the dedicated AT command. For more
details, see the SARA-G3 / SARA-U2 Series System Integration Manual [2] and the u-blox AT
commands manual [1], +USTS AT command.
2.3.3 Module reset (RESET_N)
SARA-G3 modules can be properly reset (rebooted), with storage of current parameter settings in
the module’s non-volatile memory and proper network detach, in this way:
AT+CFUN command (see the u-blox AT Commands Manual [1]). This causes an “internal” or
“software” reset of the module.
An abrupt “external” or “hardware” reset occurs when a low level is applied to the RESET_N pin,
which is normally set high by an internal pull-up, for a valid time period (see section 4.2.8), but in this
case it is not possible to perform the storing of the current parameter settings as well as the proper
network detach.
2.3.4 External 32 kHz signal input (EXT32K)
SARA-G300 and SARA-G310 provide the EXT32K input pin that must be fed by a proper 32 kHz
signal to furnish the reference clock for the RTC, allowing very low power idle-mode and RTC
functions support. See section 4.2.9 for detailed electrical specifications for the 32 kHz signal.
SARA-G340 and SARA-G350 do not provide the EXT32K input pin. An internal 32 kHz oscillator
automatically generates the reference clock for the RTC, allowing very low power idle-mode and RTC
functions support.
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Interfaces Page 14 of 49
2.3.5 Internal 32 kHz signal output (32K_OUT)
SARA-G300 and SARA-G310 provide the 32K_OUT output pin which gives a 32 kHz reference signal
suitable only to feed the EXT32K input pin of SARA-G300 / SARA-G310 modules, furnishing the
reference clock for the RTC, allowing low power idle-mode and RTC functions support with modules
switched on.
SARA-G340 and SARA-G350 do not provide the 32K_OUT output; there is no EXT32K input on these
modules.
2.4 SIM
2.4.1 (U)SIM interface
A (U)SIM card interface is available via the VSIM, SIM_IO, SIM_CLK, SIM_RST pins of SARA-G3
series modules: the high-speed SIM/ME interface is implemented as well as the automatic detection
of the required SIM supporting voltage.
Both 1.8 V and 3 V SIM types are supported: activation and deactivation with automatic voltage
switch from 1.8 V to 3 V are implemented, according to ISO-IEC 7816-3 Specifications. The SIM driver
supports the PPS procedure for baud-rate selection, according to the values proposed by the SIM
Card.
2.4.2 SIM card detection (SIM_DET)
Not supported by SARA-G300-00S and SARA-G310-00S modules.
The SIM_DET pin of SARA-G3 modules is a digital input provided to sense the SIM card presence (as
an optional feature), when it is properly connected to the mechanical switch of the SIM card holder
(for more details, see the SARA-G3 / SARA-U2 Series System Integration Manual [2]).
2.5 Serial interfaces
SARA-G3 modules provide the following serial communication interfaces:
UART interface: 9-wire unbalanced 1.8 V asynchronous serial interface supporting
AT command mode
Data mode and Online command mode
10
MUX functionality, including dedicated GNSS tunneling virtual channel
11
FW upgrades by means of the FOAT feature
Auxiliary UART interface: 3-wire unbalanced 1.8 V asynchronous serial interface supporting
AT command mode
12
GNSS tunneling 12
FW upgrades by means of the u-blox EasyFlash tool
Trace log capture (diagnostic purpose)
DDC interface
13
: I2C-bus compatible interface supporting
Communication with u-blox GPS/GNSS positioning chips / modules
10
See the u-blox AT Commands Manual [1] for the definition of the interface data mode and online command mode.
11
GNSS tunneling is not supported by SARA-G300 and SARA-G310 modules.
12
AT command mode and GNSS tunneling are not supported over the Auxiliary UART of SARA-G3 modules product versions
“00” and “01”.
13
DDC I2C-bus compatible interface is not supported by SARA-G300 and SARA-G310 modules.
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Interfaces Page 15 of 49
2.5.1 Asynchronous serial interface (UART)
The UART interface is a 9-wire unbalanced 1.8 V asynchronous serial interface provided on all
SARA-G3 modules for communication with an application processor, supporting:
AT command mode
Data mode and Online command mode
14
MUX functionality, including dedicated GNSS tunneling virtual channel
15
FW upgrades by means of the FOAT feature
UART characteristics are:
Complete serial port with RS-232 functionality conforming to the ITU-T V.24
Recommendation [8], with CMOS compatible signal levels (0 V for low data bit or ON state
and 1.8 V for high data bit or OFF state)
Data lines (RXD as output, TXD as input), hardware flow control lines (CTS as output, RTS as
input), modem status and control lines (DTR as input, DSR as output, DCD as output, RI as
output) are provided
Hardware flow control (default value), software flow control, or none flow control are
supported
Power saving indication available on the hardware flow control output (CTS line): the line is
driven to the OFF state when the module is not ready to accept data signals
2400, 4800, 9600, 19200, 38400, 57600, 115200 b/s baud rates are supported
Auto baud rate detection (autobauding) is the default configuration
Frame format can be: 8N1 (8 data bits, no parity, 1 stop bit), or 8N2 (8 data bits, no parity,
2 stop bits), or 8E1 (8 data bits, even parity, 1 stop bit), or 8O1 (8 data bits, odd parity, 1 stop
bit), or 7E1 (7 data bits, even parity, 1 stop bit), or 7O1 (7 data bits, odd parity, 1 stop bit)
Automatic frame recognition is supported: this feature is the default configuration and it is
enabled in conjunction with the auto baud rate detection only
Default frame configuration with fixed baud is 8N1 (8 data bits, no parity, 1 stop bit),
2.5.1.1 Multiplexer protocol
SARA-G3 module has a software layer with MUX functionality, 3GPP TS 27.010 [11], available on the
UART physical link.
This is a data link protocol (layer 2 of OSI model) which uses HDLC-like framing and operates
between the module (DCE) and the application processor (DTE), and allows a number of
simultaneous sessions over the physical link (UART): the user can concurrently use AT command
interface on one MUX channel and data communication on another MUX channel.
SARA-G340 and SARA-G350 modules define the following virtual channels:
Channel 0: control channel
Channel 1 5: AT commands / data connection
Channel 6: GNSS tunneling
SARA-G300 and SARA-G310 modules define the following virtual channels:
Channel 0: control channel
Channel 1 2: AT commands / data connection
For more details, see the Mux Implementation Application Note [4].
14
See the u-blox AT Commands Manual [1] for the definition of the interface data mode and online command mode.
15
GNSS tunneling is not supported by SARA-G300 and SARA-G310 modules.
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Interfaces Page 16 of 49
2.5.2 Auxiliary asynchronous serial interface (AUX UART)
The auxiliary UART interface is a 3-wire unbalanced 1.8 V asynchronous serial interface available on
all SARA-G3 modules, supporting
16
AT command mode
17
GNSS tunneling mode 17
FW upgrades by means of the u-blox EasyFlash tool
Trace log capture (diagnostic purpose)
Auxiliary UART characteristics are:
Only the RXD_AUX data output and the TXD_AUX data input are provided, with CMOS
compatible signal levels (0 V for low data bit or ON state and 1.8 V for high data bit or OFF
state)
Characteristics in AT command mode 17:
Baud rate can be: 2400, 4800, 9600, 19200, 38400, 57600, 115200 b/s, with default value
115200 b/s
Frame format can be: 8N1, or 8N2, or 8E1, or 8O1, or 7E1, or 7O1, with default value 8N1
Automatic baud rate detection (autobauding) and automatic frame recognition are not
supported
Software flow control, or None flow control (default value) are supported
Characteristics in GNSS tunneling mode 17:
Baud rate is 115200 b/s
Frame format is 8N1 (8 data bits, no parity, 1 stop bit)
None flow control is supported
Characteristics for FW upgrade and diagnostic trace modes:
115200, 230400, 460800, 921600 b/s baud rates are supported
Frame format is 8N1 (8 data bits, no parity, 1 stop bit)
None flow control is supported
2.5.3 DDC (I2C compatible) interface
SARA-G340 and SARA-G350 modules provide an I2C compatible DDC interface on the SCL and SDA
pins exclusively for the communication with u-blox GNSS positioning chips / modules.
16
See the u-blox AT Commands Manual [1], +USIO AT command for further details regarding serial interfaces configuration selection.
17
AT command mode and GNSS tunneling are not supported over the Auxiliary UART of SARA-G3 modules product versions “00” and “01”.
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Interfaces Page 17 of 49
2.6 Audio
SARA-G340 and SARA-G350 modules provide analog and digital audio interfaces:
Analog audio input:
Differential analog audio input (MIC_P, MIC_N) shared for all the analog audio path modes: the
pins can be connected to the output of an external analog audio device or can be connected to
an external microphone by means of a simple circuit implemented on the application board
Supply output for an external microphone (MIC_BIAS): the pin can provide the bias to an
external microphone by means of a simple circuit implemented on the application board
Local ground for the external microphone (MIC_GND): the pin can provide the reference for the
differential analog audio input as sense ground line for the external microphone circuit
Analog audio output:
Differential audio output (SPK_P, SPK_N) shared for all the analog audio path modes: the pins
can be connected to the input of an external analog audio device or can be connected to an
external speaker
I2S digital audio interface:
4-wire digital audio interface (I2S_TXD, I2S_RXD, I2S_CLK, I2S_WA) that can be configured by
AT command in PCM or in normal I2S mode
For more details regarding audio interfaces configuration and usage, see the u-blox AT Commands
Manual [1] and the SARA-G3 / SARA-U2 Series System Integration Manual [2].
2.7 GPIO
SARA-G340 and SARA-G350 modules provide 4 GPIO pins (GPIO1-GPIO4) that can be configured for
general purpose input/output, or to provide custom functions via u-blox AT commands (for further
details, see the SARA-G3 / SARA-U2 Series System Integration Manual [2] and to u-blox AT
Commands Manual [1], +UGPIOC, +UGPIOR, +UGPIOW, +UGPS, +UGPRF).
Table 5 summarizes the custom functions available on the GPIO pins of SARA-G340 / SARA-G350
modules.
Function
Description
Default GPIO
Configurable GPIOs
GNSS supply enable
Enable/disable the supply of u-blox positioning chips and
modules connected to cellular module
GPIO2
GPIO1, GPIO2,
GPIO3, GPIO4
GNSS data ready
Sense when u-blox positioning chip / module connected to
cellular module is ready for sending data by the DDC (I2C)
GPIO3
GPIO3
GNSS RTC sharing
RTC (Real Time Clock) synchronization signal to u-blox
positioning chips and modules connected to cellular module
GPIO4
GPIO4
Network status
indication
Indicates network status: registered home network,
registered roaming, data transmission, no service
--
GPIO1, GPIO2,
GPIO3, GPIO4
GSM Tx-burst
indication
Indicates when a GSM Tx burst/slot occurs
--
GPIO1
Jamming condition
indication
Indicates when a jamming condition occurs
--
GPIO1, GPIO2,
GPIO3, GPIO4
General purpose
input
Input to sense high or low digital level
--
GPIO1, GPIO2,
GPIO3, GPIO4
General purpose
output
Output to set the high or the low digital level
--
GPIO1, GPIO2,
GPIO3, GPIO4
Pad disabled
Tri-state with an internal active pull-down enabled
GPIO1
GPIO1, GPIO2,
GPIO3, GPIO4
Table 5: GPIO custom functions configuration
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Pin definition Page 18 of 49
3 Pin definition
3.1 Pin assignment
64 63 61 60 58 57 55 54
22 23 25 26 28 29 31 32
11
10
8
7
5
4
2
1
21
19
18
16
15
13
12
43
44
46
47
49
50
52
53
33
35
36
38
39
41
42
65 66 67 68 69 70
71 72 73 74 75 76
77 78
79 80
81 82
83 84
85 86 87 88 89 90
91 92 93 94 95 96
CTS
RTS
DCD
RI
V_INT
V_BCKP
GND
RSVD
RESET_N
RSVD
PWR_ON
RXD
TXD
3
20
17
14
9
6
24 27 30
51
48
45
40
37
34
5962 56
GND
GND
DSR
DTR
GND
RSVD
GND
GND
RXD_AUX
TXD_AUX
EXT32K
GND
RSVD
32K_OUT
RSVD
RSVD
RSVD
GND
GND
GND
RSVD
RSVD
RSVD
RSVD
GND
VCC
VCC
RSVD
RSVD
RSVD
SIM_CLK
SIM_IO
VSIM
SIM_DET
VCC
RSVD
RSVD
SIM_RST
RSVD
RSVD
GND
GND
GND
GND
GND
GND
GND
GND
GND
RSVD
ANT
SARA-G300
SARA-G310
Top View
Pin 65-96: GND
64 63 61 60 58 57 55 54
22 23 25 26 28 29 31 32
11
10
8
7
5
4
2
1
21
19
18
16
15
13
12
43
44
46
47
49
50
52
53
33
35
36
38
39
41
42
65 66 67 68 69 70
71 72 73 74 75 76
77 78
79 80
81 82
83 84
85 86 87 88 89 90
91 92 93 94 95 96
CTS
RTS
DCD
RI
V_INT
V_BCKP
GND
RSVD
RESET_N
GPIO1
PWR_ON
RXD
TXD
3
20
17
14
9
6
24 27 30
51
48
45
40
37
34
5962 56
GND
GND
DSR
DTR
GND
RSVD
GND
GND
RXD_AUX
TXD_AUX
RSVD
GND
GPIO2
GPIO3
SDA
SCL
GPIO4
GND
GND
GND
SPK_P
MIC_BIAS
MIC_GND
MIC_P
GND
VCC
VCC
RSVD
I2S_TXD
I2S_CLK
SIM_CLK
SIM_IO
VSIM
SIM_DET
VCC
MIC_N
SPK_N
SIM_RST
I2S_RXD
I2S_WA
GND
GND
GND
GND
GND
GND
GND
GND
GND
ANT_DET
ANT
SARA-G340
SARA-G350
Top View
Pin 65-96: GND
Figure 3: SARA-G3 series modules pin assignments
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Pin definition Page 19 of 49
No
Module
Name
Power
domain
I/O
Description
Remarks
1
All
GND
-
N/A
Ground
All the GND pads must be connected to ground.
2
All
V_BCKP
-
I/O
Real Time
Clock supply
input/output
V_BCKP = 2.3 V (typical) generated by the module
to supply the Real Time Clock when VCC supply
voltage is within valid operating range.
See section 4.2.3 for detailed electrical specs.
3
All
GND
-
N/A
Ground
All the GND pads must be connected to ground.
4
All
V_INT
-
O
Digital I/O
Interfaces
supply output
V_INT = 1.8V (typical) generated by the module
when it is switched-on.
See section 4.2.3 for detailed electrical specs.
5
All
GND
-
N/A
Ground
All the GND pads must be connected to ground.
6
All
DSR
GDI
O
UART data set
ready
Circuit 107 (DSR) in ITU-T V.24.
Output driver class A.
PU/PD class a. Value at reset: T/PU.
See section 4.2.11 for detailed electrical specs.
7
All
RI
GDI
O
UART ring
indicator
Circuit 125 (RI) in ITU-T V.24.
Output driver class A.
PU/PD class b. Value at reset: T/PU.
See section 4.2.11 for detailed electrical specs.
8
All
DCD
GDI
O
UART data
carrier detect
Circuit 109 (DCD) in ITU-T V.24.
Output driver class A.
PU/PD class a. Value at reset: T/PU.
See section 4.2.11 for detailed electrical specs.
9
All
DTR
GDI
I
UART data
terminal ready
Circuit 108/2 (DTR) in ITU-T V.24.
Internal active pull-up to V_INT enabled.
PU/PD class b. Value at reset: T/PU.
See section 4.2.11 for detailed electrical specs.
10
All
RTS
GDI
I
UART ready to
send
Circuit 105 (RTS) in ITU-T V.24.
Internal active pull-up to V_INT enabled.
PU/PD class c. Value at reset: T/PU.
See section 4.2.11 for detailed electrical specs.
11
All
CTS
GDI
O
UART clear to
send
Circuit 106 (CTS) in ITU-T V.24.
Output driver class A.
PU/PD class c. Value at reset: T/PD.
See section 4.2.11 for detailed electrical specs.
12
All
TXD
GDI
I
UART
transmitted
data
Circuit 103 (TxD) in ITU-T V.24.
Internal active pull-up to V_INT enabled.
PU/PD class a. Value at reset: T/PU.
See section 4.2.11 for detailed electrical specs.
13
All
RXD
GDI
O
UART received
data
Circuit 104 (RxD) in ITU-T V.24.
Output driver class B.
PU/PD class a. Value at reset: T/PU.
See section 4.2.11 for detailed electrical specs.
14
All
GND
-
N/A
Ground
All the GND pads must be connected to ground.
15
All
PWR_ON
POS
I
Power-on
input
The PWR_ON pin has high input impedance:
don’t leave it floating in noisy environment
(an external pull-up resistor is required).
See section 4.2.7 for detailed electrical specs.
16
SARA-G350
SARA-G340
GPIO1
GDI
I/O
GPIO
Configurable GPIO: see Table 5 for the available
custom functions.
Output driver class A.
PU/PD class b. Value at reset: T/PD.
See section 4.2.11 for detailed electrical specs.
SARA-G310
SARA-G300
RSVD
-
N/A
RESERVED pin
Pin disabled. Leave unconnected.
17
All
RSVD
-
N/A
RESERVED pin
Leave unconnected.
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Pin definition Page 20 of 49
No
Module
Name
Power
domain
I/O
Description
Remarks
18
All
RESET_N
ERS
I
Reset signal
A series Schottky diode is integrated in the
module as protection, and then an internal 10 k
pull-up resistor to V_INT is provided.
See section 4.2.8 for detailed electrical specs.
For more details regarding module reset, see [2].
19
All
RSVD
-
N/A
RESERVED pin
Leave unconnected.
20
All
GND
-
N/A
Ground
All the GND pads must be connected to ground.
21
All
GND
-
N/A
Ground
All the GND pads must be connected to ground.
22
All
GND
-
N/A
Ground
All the GND pads must be connected to ground.
23
SARA-G350
SARA-G340
GPIO2
GDI
I/O
GPIO
By default, the pin is configured to provide the
GNSS supply enable function.
Output driver class A.
PU/PD class b. Value at reset: T/PD.
See section 4.2.11 for detailed electrical specs.
SARA-G310
SARA-G300
RSVD
-
N/A
RESERVED pin
Pin disabled. Leave unconnected.
24
SARA-G350
SARA-G340
GPIO3
GDI
I/O
GPIO
By default, the pin is configured to provide the
GNSS data ready function.
Output driver class B.
PU/PD class c. Value at reset: T/PD.
See section 4.2.11 for detailed electrical specs.
SARA-G310
SARA-G300
32K_OUT
-
O
32 kHz output
32 kHz output suitable only to feed the EXT32K
input giving the RTC reference clock, allowing low
power idle-mode and RTC functions support.
25
SARA-G350
SARA-G340
GPIO4
GDI
I/O
GPIO
By default, the pin is configured to provide the
GNSS RTC sharing function.
Output driver class A.
PU/PD class b. Value at reset: T/PD.
See section 4.2.11 for detailed electrical specs.
SARA-G310
SARA-G300
RSVD
-
N/A
RESERVED pin
Pin disabled. Leave unconnected.
26
SARA-G350
SARA-G340
SDA
DDC
I/O
I2C bus data
line
Fixed open drain. No internal pull-up.
Value at reset: T.
See section 4.2.12 for detailed electrical specs.
SARA-G310
SARA-G300
RSVD
-
N/A
RESERVED pin
Pin disabled. Leave unconnected.
27
SARA-G350
SARA-G340
SCL
DDC
O
I2C bus clock
line
Fixed open drain. No internal pull-up.
Value at reset: T.
See section 4.2.12 for detailed electrical specs.
SARA-G310
SARA-G300
RSVD
-
N/A
RESERVED pin
Pin disabled. Leave unconnected.
28
All
RXD_AUX
GDI
O
Auxiliary UART
received data
Circuit 104 (RxD) in ITU-T V.24.
Output driver class B.
PU/PD class a. Value at reset: T/PU.
See section 4.2.11 for detailed electrical specs.
29
All
TXD_AUX
GDI
I
Auxiliary UART
transmitted
data
Circuit 103 (TxD) in ITU-T V.24.
Internal active pull-up to V_INT enabled.
PU/PD class a. Value at reset: T/PU.
See section 4.2.11 for detailed electrical specs.
30
All
GND
-
N/A
Ground
All the GND pads must be connected to ground.
31
SARA-G350
SARA-G340
RSVD
-
N/A
RESERVED pin
Internally not connected. Leave unconnected.
SARA-G310
SARA-G300
EXT32K
-
I
32 kHz input
Input for RTC reference clock, needed to enter
the low power idle-mode and provide RTC
functions.
See section 4.2.9 for detailed electrical specs.
32
All
GND
-
N/A
Ground
All the GND pads must be connected to ground.
33
All
RSVD
-
N/A
RESERVED pin
This pin must be connected to GND.
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Pin definition Page 21 of 49
No
Module
Name
Power
domain
I/O
Description
Remarks
34
SARA-G350
SARA-G340
I2S_WA
GDI
O
I2S word
alignment
Output driver class A.
PU/PD class c. Value at reset: T/PU.
See section 4.2.11 for detailed electrical specs.
SARA-G310
SARA-G300
RSVD
-
N/A
RESERVED pin
Pin disabled. Leave unconnected.
35
SARA-G350
SARA-G340
I2S_TXD
GDI
O
I2S transmit
data
Output driver class B.
PU/PD class c. Value at reset: T/PD.
See section 4.2.11 for detailed electrical specs.
SARA-G310
SARA-G300
RSVD
-
N/A
RESERVED pin
Pin disabled. Leave unconnected.
36
SARA-G350
SARA-G340
I2S_CLK
GDI
O
I2S clock
Output driver class B.
PU/PD class a. Value at reset: T/PU.
See section 4.2.11 for detailed electrical specs.
SARA-G310
SARA-G300
RSVD
-
N/A
RESERVED pin
Pin disabled. Leave unconnected.
37
SARA-G350
SARA-G340
I2S_RXD
GDI
I
I2S receive
data
Internal active pull-down enabled.
PU/PD class a. Value at reset: T/PD.
See section 4.2.11 for detailed electrical specs.
SARA-G310
SARA-G300
RSVD
-
N/A
RESERVED pin
Pin disabled. Leave unconnected.
38
All
SIM_CLK
SIM
O
SIM clock
Value at reset: L.
See section 4.2.10 for detailed electrical specs.
39
All
SIM_IO
SIM
I/O
SIM data
Internal 4.7k pull-up to VSIM.
Value at reset: L.
See section 4.2.10 for detailed electrical specs.
40
All
SIM_RST
SIM
O
SIM reset
Value at reset: L.
See section 4.2.10 for detailed electrical specs.
41
All
VSIM
-
O
SIM supply
output
VSIM = 1.80 V typical if SIM card = 1.8V type.
VSIM = 2.85 V typical if SIM card = 3.0V type.
See section 4.2.3 for detailed electrical specs.
42
All
SIM_DET
GDI
I
SIM detection
SIM card presence detection function.
PU/PD class a. Value at reset: T/PU.
See section 4.2.11 for detailed electrical specs.
43
All
GND
-
N/A
Ground
All the GND pads must be connected to ground.
44
SARA-G350
SARA-G340
SPK_P
AUDIO
O
Differential
analog audio
output
(positive)
Differential analog audio output shared for all the
analog audio path modes.
See section 4.2.13 for detailed electrical specs.
SARA-G310
SARA-G300
RSVD
-
N/A
RESERVED pin
Leave unconnected.
45
SARA-G350
SARA-G340
SPK_N
AUDIO
O
Differential
analog audio
output
(negative)
Differential analog audio output shared for all the
analog audio path modes.
See section 4.2.13 for detailed electrical specs.
SARA-G310
SARA-G300
RSVD
-
N/A
RESERVED pin
Leave unconnected.
46
SARA-G350
SARA-G340
MIC_BIAS
AUDIO
O
Microphone
supply output
Supply output for the external microphone.
See section 4.2.13 for detailed electrical specs.
SARA-G310
SARA-G300
RSVD
-
N/A
RESERVED pin
Leave unconnected.
47
SARA-G350
SARA-G340
MIC_GND
AUDIO
I
Microphone
analog
reference
Local ground for the external microphone
(reference for the differential analog audio input).
See section 4.2.13 for detailed electrical specs.
SARA-G310
SARA-G300
RSVD
-
N/A
RESERVED pin
Leave unconnected.
48
SARA-G350
SARA-G340
MIC_N
AUDIO
I
Differential
analog audio
input
(negative)
Differential analog audio input shared for all the
analog audio path modes.
See section 4.2.13 for detailed electrical specs.
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Pin definition Page 22 of 49
No
Module
Name
Power
domain
I/O
Description
Remarks
SARA-G310
SARA-G300
RSVD
-
N/A
RESERVED pin
Leave unconnected.
49
SARA-G350
SARA-G340
MIC_P
AUDIO
I
Differential
analog audio
input (positive)
Differential analog audio input shared for all the
analog audio path modes.
See section 4.2.13 for detailed electrical specs.
SARA-G310
SARA-G300
RSVD
-
N/A
RESERVED pin
Leave unconnected.
50
All
GND
-
N/A
Ground
All the GND pads must be connected to ground.
51
All
VCC
-
I
Module supply
input
All VCC pins must be connected to external
supply.
Supply input for internal BB PMU and transceiver
on SARA-G3 modules product versions ‘02’
onward.
See section 4.2.3, 4.2.4 for detailed electrical
spec.
52
All
VCC
-
I
Module supply
input
All VCC pins must be connected to external
supply.
Supply input for the internal RF power amplifier
on SARA-G3 modules product versions ‘02’
onward.
See section 4.2.3, 4.2.4 for detailed electrical
spec.
53
All
VCC
-
I
Module supply
input
All VCC pins must be connected to external
supply.
Supply input for the internal RF power amplifier
on SARA-G3 modules product versions ‘02’
onward.
See section 4.2.3, 4.2.4 for detailed electrical
spec.
54
All
GND
-
N/A
Ground
All the GND pads must be connected to ground.
55
All
GND
-
N/A
Ground
All the GND pads must be connected to ground.
56
All
ANT
-
I/O
RF antenna
50 nominal impedance
See section 4.2.5 for detailed electrical specs.
57
All
GND
-
N/A
Ground
All the GND pads must be connected to ground.
58
All
GND
-
N/A
Ground
All the GND pads must be connected to ground.
59
All
GND
-
N/A
Ground
All the GND pads must be connected to ground.
60
All
GND
-
N/A
Ground
All the GND pads must be connected to ground.
61
All
GND
-
N/A
Ground
All the GND pads must be connected to ground.
62
SARA-G350
SARA-G340
ANT_DET
ADC
I
Antenna
detection
Antenna presence detection function.
See section 4.2.6 for detailed electrical specs.
SARA-G310
SARA-G300
RSVD
-
N/A
RESERVED pin
Leave unconnected.
63
All
GND
-
N/A
Ground
All the GND pads must be connected to ground.
64
All
GND
-
N/A
Ground
All the GND pads must be connected to ground.
65-
96
All
GND
-
N/A
Ground
All the GND pads must be connected to ground.
Table 6: SARA-G3 series module pin-out
For more information about pin-out, see the SARA-G3 / SARA-U2 Series System Integration
Manual [2].
For an explanation of abbreviations and terms used, see Appendix A.
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Electrical specifications Page 23 of 49
4 Electrical specifications
Stressing the device above one or more of the ratings listed in the Absolute Maximum Rating
section may cause permanent damage. These are stress ratings only. Operating the module at
these or at any conditions other than those specified in the Operating Conditions sections
(chapter 4.2) of the specification should be avoided. Exposure to Absolute Maximum Rating
conditions for extended periods may affect device reliability.
Operating conditions ranges define those limits within which the functionality of the device is
guaranteed.
Electrical characteristics are defined according to the verification on a representative number of
samples or according to the simulation.
Where application information is given, it is advisory only and does not form part of the
specification.
4.1 Absolute maximum rating
Limiting values given below are in accordance with the Absolute Maximum Rating System
(IEC 134).
Symbol
Description
Condition
Min
Max
Unit
VCC
Module supply voltage
Input DC voltage at VCC pins
-0.15
5.5
V
V_BCKP
RTC supply voltage
Input DC voltage at V_BCKP pin
-0.15
2.5
V
GDI
Generic digital interfaces
Input DC voltage at Generic digital interfaces pins
-0.15
2.2
V
DDC
DDC interface
Input DC voltage at DDC interface pins
-0.15
3.6
V
SIM
SIM interface
Input DC voltage at SIM interface pins
-0.30
3.6
V
ERS
External reset signal
Input DC voltage at RESET_N pin
-0.15
6.0
V
POS
Power-on signal
Input DC voltage at PWR_ON pin
-0.15
6.0
V
AUDIO
Audio pins
Input DC voltage at Audio pins
-0.15
3.0
V
ADC
Antenna detection pin
Input DC voltage at ANT_DET pin
-0.15
3.0
V
P_ANT
Antenna power
In-band input RF power at ANT pin
-8
dBm
Rho_ANT
Antenna ruggedness
Output RF load mismatch ruggedness at ANT pin
20:1
VSWR
Tstg
Storage temperature
range
-40
+85
°C
Table 7: Absolute maximum ratings
The product is not protected against overvoltage or reversed voltages. If necessary, voltage
spikes exceeding the power supply voltage specification, given in table above, must be limited to
values within the specified boundaries by using appropriate protection devices.
4.1.1 Maximum ESD
Parameter
Min
Typical
Max
Unit
Remarks
ESD sensitivity for all pins except
ANT pin
1000
V
Human Body Model according to JESD22-A114
ESD sensitivity for ANT pin
1000
V
Human Body Model according to JESD22-A114
ESD immunity for ANT pin
4000
V
Contact Discharge according to IEC 61000-4-2
8000
V
Air Discharge according to IEC 61000-4-2
Table 8: Maximum ESD ratings
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Electrical specifications Page 24 of 49
u-blox cellular modules are Electrostatic Sensitive Devices (ESD) and require special
precautions when handling. See section 7.4 for ESD handling instructions.
4.2 Operating conditions
Unless otherwise specified, all operating condition specifications are at an ambient
temperature of +25 °C.
Operation beyond the operating conditions is not recommended and extended exposure beyond
them may affect device reliability
4.2.1 Operating temperature range
Symbol
Parameter
Module
Min
Typical
Max
Units
Remarks
Topr
Operating temperature range
All
-40
+25
+85
°C
All
-30
+85
°C
Normal operating range
see chapter 4.2.1.1
All
-40
+85
°C
Extended operating range
see chapter 4.2.1.2
Table 9: Environmental conditions
4.2.1.1 Normal operating temperature range
SARA-G3 series modules are fully functional and meet 3GPP specifications across the specified
temperature range.
4.2.1.2 Extended operating temperature range
SARA-G3 series modules are fully functional across the specified temperature range. RF
performance may be affected outside the normal operating temperature range.
4.2.2 Module thermal resistance
Symbol
Parameter
Min
Typical
Max
Unit
Remarks
Rth,M-A
Module-to-Ambient
thermal resistance
10.6
°C/W
Thermal resistance from the module internal
temperature sensor to the ambient, with the module
mounted on a 79 mm x 62 mm x 1.41 mm 4-layer PCB
with a high coverage of copper in still air conditions
Rth,M-C
Module-to-Case
thermal resistance
1.7
°C/W
Thermal resistance from the module internal
temperature sensor to the module case, evaluated
as the thermal resistance from the module internal
temperature sensor to the ambient, with the module
mounted on a 79 mm x 62 mm x 1.41 mm 4-layer PCB
with a high coverage of copper, with a robust
aluminum heat-sink on the back of the application
board, with forced air ventilation.
Table 10: SARA-G3 series modules thermal resistance
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Electrical specifications Page 25 of 49
4.2.3 Supply/Power pins
Symbol
Parameter
Min
Typical
Max
Unit
VCC
Module supply normal operating voltage 18
3.35
3.80
4.50
V
Module supply extended operating voltage 19
3.00
4.50
V
Module supply extended operating voltage 20
2.80
4.50
V
ICC_PEAK 21
Module peak of current consumption through all the
VCC pins, during a GSM 1-slot transmit burst at
maximum power level, with a matched antenna
1.50
1.60
A
Module peak of current consumption through all the
VCC pins, during a GSM 1-slot transmit burst at
maximum power level, with a mismatched antenna
1.90
A
Module peak of current consumption through the VCC
pin #51 of SARA-G3 modules product versions “02”
onwards
300
mA
V_BCKP
Real Time Clock Supply input voltage
1.00
2.30
2.40
V
I_BCKP
Real Time Clock Supply average current consumption,
at V_BCKP = 2.3 V
2.00
µA
Table 11: Input characteristics of Supply/Power pins
Symbol
Parameter
Min
Typical
Max
Unit
VSIM
SIM Supply
1.76
1.80
1.84
V
2.78
2.85
2.91
V
V_BCKP
Real Time Clock Supply output voltage
2.19
2.30
2.42
V
I_BCKP
Real Time Clock Supply output current capability
2
mA
V_INT
Digital I/O Interfaces supply output voltage
1.75
1.80
1.85
V
V_INT_RIPPLE
Digital I/O Interfaces supply output peak-to-peak
voltage ripple during active or connected mode
15
mV
Digital I/O Interfaces supply output peak-to-peak
voltage ripple during low power idle mode with power
saving enabled
90
mV
I_INT
Digital I/O Interfaces supply output current capability
70
mA
Table 12: Output characteristics of Supply/Power pins
4.2.4 Current consumption
Mode
Module
Band
Condition
Min
Typ
Max
Unit
Power Off Mode
All
-
Module is switched off by
AT+CPWROFF
36
40
µA
Idle-Mode
(Power Saving enabled by
AT+UPSV,
module in low power idle-
mode, equivalent to
+CFUN=4 or +COPS=2)
SARA-G300
SARA-G310
-
Averaged current over a 100-ms
period, EXT32K fed by external
32.768 kHz signal
0.3
0.4
mA
Averaged current over a 100-ms
period, EXT32K fed by 32K_OUT
output signal
3.9
4.0
mA
SARA-G340
SARA-G350
-
Averaged current over a 100-ms
period
0.3
0.4
mA
18
The input voltage at all the VCC must be above the normal operating range minimum limit to switch-on the module. Module
is still fully functional when the input voltage at the VCC pins drops below the herein stated normal operating range minimum
limit, but RF performance may be affected.
19
Range defined for all the VCC pins of product versions “00” and “01”, and the VCC pin #51 (supply input for internal baseband
Power Management Unit and the internal transceiver) of product versions “02” onwards. Module may switch off when the input
voltage at the related pins drops below the herein stated extended operating range minimum limit.
20
Range defined for the VCC pins #52 and #53 (supply input for the internal power amplifier) of product versions “02” onwards.
21
Use this figure to dimension maximum current capability of power supply.
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Electrical specifications Page 26 of 49
Mode
Module
Band
Condition
Min
Typ
Max
Unit
Cyclic Idle/Active-Mode
(Power Saving enabled by
AT+UPSV, Module
registered with network)
SARA-G300
SARA-G310
All
Averaged current over a 10-minute
period, DRX = 922, AT+UPSV=2
EXT32K fed by external 32.768 kHz
signal
0.6
0.8
mA
Averaged current over a 10-minute
period, DRX = 922, AT+UPSV=2
EXT32K fed by 32K_OUT output signal
4.2
4.4
mA
Averaged current over a 10-minute
period, DRX = 523, AT+UPSV=1
EXT32K fed by external 32.768 kHz
signal
0.9
1.1
mA
Averaged current over a 10-minute
period, DRX = 523, AT+UPSV=1
EXT32K fed by 32K_OUT output signal
4.5
4.7
mA
SARA-G340
SARA-G350
All
Averaged current over a 10-minute
period, DRX = 922, AT+UPSV=2
0.6
0.8
mA
Averaged current over a 10-minute
period, DRX = 523, AT+UPSV=1
0.9
1.1
mA
Active-Mode
(Power Saving disabled by
AT+UPSV, Module
registered with network)
SARA-G300
SARA-G310
All
Averaged current over a 10-minute
period, DRX = 523, AT+UPSV=0
(default)
EXT32K fed by external 32.768 kHz
signal
4.2
4.4
mA
Averaged current over a 10-minute
period, DRX = 523, AT+UPSV=0
(default)
EXT32K fed by 32K_OUT output signal
4.5
4.7
mA
Averaged current over a 10-minute
period, DRX = 523, AT+UPSV=0
(default)
EXT32K not fed
18.0
18.2
mA
SARA-G340
SARA-G350
All
Averaged current over a 10-minute
period, DRX = 523, AT+UPSV=0
(default)24
2.9
3.1
mA
GSM Connected Mode
(Call enabled)
All
850,
900
Averaged current over a 10-second
period,
1 Tx + 1 Rx slot
Maximum Tx power (32.2 dBm typ.)
200
250
mA
1800,
1900
Averaged current over a 10-second
period,
1 Tx + 1 Rx slot
Maximum Tx power (29.2 dBm typ.)
150
200
mA
GPRS Connected Mode
(Call enabled)
All
850,
900
Averaged current over a 10-second
period,
2 Tx + 3 Rx slots
Maximum Tx power (30.5 dBm typ.)
300
350
mA
1800,
1900
Averaged current over a 10-second
period,
2 Tx + 3 Rx slots
Maximum Tx power (27.5 dBm typ.)
210
260
mA
Table 13: VCC current consumption
25
22
Module is registered with the network, with a paging period of 2.12 s (2G network DRX setting = 9), with none neighbour cell.
23
Module is registered with the network, with a paging period of 1.18 s (2G network DRX setting = 5), with 16 neighbour cells.
24
18.2 mA typical, 18.4 mA maximum for SARA-G340 and SARA-G350 modules product versions “00”
25
Averaged values for module current consumption through VCC pins in the listed modes/conditions
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Electrical specifications Page 27 of 49
4.2.5 RF performance
Parameter
Min
Max
Unit
Remarks
Frequency range
GSM 850
Uplink
824
849
MHz
Module transmit
Downlink
869
894
MHz
Module receive
Frequency range
E-GSM 900
Uplink
880
915
MHz
Module transmit
Downlink
925
960
MHz
Module receive
Frequency range
DCS 1800
Uplink
1710
1785
MHz
Module transmit
Downlink
1805
1880
MHz
Module receive
Frequency range
PCS 1900
Uplink
1850
1910
MHz
Module transmit
Downlink
1930
1990
MHz
Module receive
Table 14: Operating RF frequency bands
Parameter
Min
Typical
Max
Unit
Remarks
Receiver input sensitivity
GSM 850
-109
dBm
Downlink RF level @ BER Class II < 2.4 %
Receiver input sensitivity
E-GSM 900
-109
dBm
Downlink RF level @ BER Class II < 2.4 %
Receiver input sensitivity
DCS 1800
-109
dBm
Downlink RF level @ BER Class II < 2.4 %
Receiver input sensitivity
PCS 1900
-109
dBm
Downlink RF level @ BER Class II < 2.4 %
Condition: 50 source
Table 15: Receiver sensitivity performance
Parameter
Min
Typical
Max
Unit
Remarks
Maximum output power
GSM 850 / E-GSM 900
32.2
dBm
Uplink burst RF power for GSM or GPRS 1-slot TCH
at maximum output power control level (PCL 5 or
Gamma 3)
30.5
dBm
Uplink burst RF power for GPRS 2-slot TCH
at maximum output power control level (Gamma 3)
Maximum output power
DCS 1800 / PCS 1900
29.2
dBm
Uplink burst RF power for GSM or GPRS 1-slot TCH
at maximum output power control level (PCL 0 or
Gamma 3)
27.5
dBm
Uplink burst RF power for GPRS 2-slot TCH
at maximum output power control level (Gamma 3)
Condition: 50 output load
Table 16: Transmitter maximum output power
4.2.6 ANT_DET pin
Pin Name
Parameter
Min
Typical
Max
Unit
Remarks
ANT_DET
Output DC current pulse
value
20
µA
Output DC current pulse
time length
3.7
5.4
8.1
ms
Table 17: ANT_DET pin characteristics
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Electrical specifications Page 28 of 49
4.2.7 PWR_ON pin
Pin Name
Parameter
Min
Typical
Max
Unit
Remarks
PWR_ON
Internal supply for
Power-On Input Signal
2.19
2.30
2.42
V
Real Time Clock supply (V_BCKP)
L-level input
-0.10
0.65
V
High input impedance (no internal pull-up)
H-level input
2.00
4.50
V
High input impedance (no internal pull-up)
L-level input current
-8
µA
PWR_ON low time
to switch-on the module
5
ms
Table 18: PWR_ON pin characteristics
4.2.8 RESET_N pin
Pin Name
Parameter
Min
Typical
Max
Unit
Remarks
RESET_N
Internal supply for
External Reset Signal
1.75
1.80
1.85
V
Digital I/O Interfaces supply (V_INT)
L-level input
-0.10
0.15
V
A series Schottky diode is integrated in the
module as protection:
the module senses a low level when the
RESET_N pin is forced low.
H-level input
1.40
4.50
V
A series Schottky diode is integrated in the
module as protection:
the module senses a low level when the
RESET_N pin is forced low.
Pull-up resistance
10
k
Internal pull-up to V_INT after the internal
series Schottky diode
L-level input current
-180
µA
RESET_N low time
to perform a proper
reset
50
ms
SARA-G340, SARA-G350
RESET_N low time
to perform a proper
reset
3000
ms
SARA-G300, SARA-G310
Table 19: RESET_N pin characteristics
4.2.9 EXT32K pin
Pin Name
Parameter
Min
Typical
Max
Unit
Remarks
EXT32K
L-level input
-0.25
0.20
V
H-level input
V_BCKP
0.20
V_BCKP
+ 0.25
V
V_BCKP = 2.3 V (typical) generated by
the internal LDO linear regulator
when valid VCC supply is present.
Input clock frequency
32.765
32.768
32.771
kHz
Frequency tolerance: +/- 100 ppm
Table 20: EXT32K pin characteristics
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Electrical specifications Page 29 of 49
4.2.10 SIM pins
Parameter
Min
Typical
Max
Unit
Remarks
Low-level input
0.37
V
VSIM = 1.80 V
0.60
V
VSIM = 2.85 V
High-level input
1.22
3.30
V
VSIM = 1.80 V
1.95
3.30
V
VSIM = 2.85 V
Low-level output
0.00
0.35
V
VSIM = 1.80 V, Max value at IOL = +1.0 mA
0.00
0.35
V
VSIM = 2.85 V, Max value at IOL = +1.0 mA
High-level output
1.45
1.80
V
VSIM = 1.80 V, Min value at IOH = -1.0 mA
2.50
2.85
V
VSIM = 2.85 V, Min value at IOH = -1.0 mA
Input/Output leakage current
0.7
µA
0.2 V < VIN < 3.3 V
Internal pull-up resistor on
SIM_IO to VSIM
4.7
k
Clock frequency on SIM_CLK
3.25
MHz
Table 21: SIM pins characteristics
4.2.11 Generic Digital Interfaces pins
Parameter
Min
Typical
Max
Unit
Remarks
Internal supply for GDI domain
1.75
1.80
1.85
V
Digital I/O Interfaces supply (V_INT)
Input characteristic:
L-level input
-0.20
0.35
V
Input characteristic:
H-level input
1.30
1.95
V
Output characteristics:
L-level output
0.00
0.20
V
Max value at IOL = +3.0 mA for Driver Class A
0.00
0.35
V
Max value at IOL = +6.0 mA for Driver Class A
0.00
0.20
V
Max value at IOL = +2.5 mA for Driver Class B
0.00
0.35
V
Max value at IOL = +5.0 mA for Driver Class B
Output characteristics:
H-level output
1.60
1.80
V
Min value at IOH = -3.0 mA for Driver Class A
1.45
1.80
V
Min value at IOH = -6.0 mA for Driver Class A
1.60
1.80
V
Min value at IOH = -2.5 mA for Driver Class B
1.45
1.80
V
Min value at IOH = -5.0 mA for Driver Class B
Input/Output leakage current
0.7
µA
0.2 V < VIN < 1.95 V
Pull-up input current
-102
µA
PU Class a
-55
µA
PU Class b
-31
µA
PU Class c
Pull-down input current
103
µA
PD Class a
51
µA
PD Class b
27
µA
PD Class c
Table 22: GDI pins characteristics
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Electrical specifications Page 30 of 49
4.2.11.1 AC characteristics of digital audio interfaces pins
The 4-wire I2S digital audio interfaces can be configured in 2 different modes:
Normal I2S mode with Master role
PCM mode with Master role
4.2.11.1.1 Normal I2S mode with Master role
I2S_TX / I2S_WA
T6
T7
I2S_RX
T1
T2
T3
I2S_CLK
T4
T5
Figure 4: AC characteristics of digital audio interface in normal I2S mode (<I2S_mode> = 2, 4, 6, 8, 10, 12)
I2S_TX / I2S_WA
T6
T7
I2S_RX
T1
T2
T3
I2S_CLK
T4
T5
Figure 5: AC characteristics of digital audio interface in normal I2S mode (<I2S_mode> = 3, 5, 7, 9, 11, 13)
Parameter
Description
Min
Typical
Max
Unit
Remarks
T1
I2S_CLK period
3.902
3.906
µs
<I2S_mode> = 2,..,13
1/T1
I2S_CLK frequency
256
kHz
<I2S_mode> = 2,..,13
T2
I2S_CLK high time
1.933
1.953
µs
<I2S_mode> = 2,..,13
T3
I2S_CLK low time
1.933
1.953
µs
<I2S_mode> = 2,..,13
I2S_WA period
125.0
µs
<I2S_mode> = 2,..,13
I2S_WA frequency
8
kHz
<I2S_mode> = 2,..,13
T4
I2S_TX invalid before I2S_CLK low end
24
ns
<I2S_mode> = 2,4,6,8,10,12
I2S_TX invalid before I2S_CLK high end
24
ns
<I2S_mode> = 3,5,7,9,11,13
T5
I2S_TX valid after I2S_CLK high begin
31
ns
<I2S_mode> = 2,4,6,8,10,12
I2S_TX valid after I2S_CLK low begin
31
ns
<I2S_mode> = 3,5,7,9,11,13
T6
I2S_RX setup time before I2S_CLK high
end
60
ns
<I2S_mode> = 2,4,6,8,10,12
I2S_RX setup time before I2S_CLK low
end
60
ns
<I2S_mode> = 3,5,7,9,11,13
T7
I2S_RX hold time after I2S_CLK low
begin
12
ns
<I2S_mode> = 2,4,6,8,10,12
I2S_RX hold time after I2S_CLK high
begin
12
ns
<I2S_mode> = 3,5,7,9,11,13
Table 23: AC characteristics of digital audio interface in normal I2S mode (<I2S_mode> = 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13)
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Electrical specifications Page 31 of 49
4.2.11.1.2 PCM mode with Master role
T4 T5
T6 T7
I2S_RX
I2S_CLK
T8
T9
I2S_WA
LSB
I2S_TX
LSB
MSB
MSB
T1
T2
T3
Figure 6: AC characteristics of digital audio interface in PCM mode (<I2S_mode> = 0)
T4 T5
T6 T7
I2S_WA
I2S_CLK
I2S_RX
LSB
MSB
MSB
I2S_TX
LSB
T8
T9
T1
T2
T3
Figure 7: AC characteristics of digital audio interface in PCM mode (<I2S_mode> = 1)
Parameter
Description
Min
Typical
Max
Unit
Remarks
T1
I2S_CLK period
6.940
6.944
µs
<I2S_mode> = 0
7.349
7.353
µs
<I2S_mode> = 1
1/T1
I2S_CLK frequency
144
kHz
<I2S_mode> = 0
136
kHz
<I2S_mode> = 1
T2
I2S_CLK low time
3.452
3.472
µs
<I2S_mode> = 0
3.656
3.676
µs
<I2S_mode> = 1
T3
I2S_CLK high time
3.452
3.472
µs
<I2S_mode> = 0
3.656
3.676
µs
<I2S_mode> = 1
I2S_WA period
125.0
µs
<I2S_mode> = 0,1
I2S_WA frequency
8
kHz
<I2S_mode> = 0,1
T4
I2S_CLK high begin to I2S_WA high
begin
-24
31
ns
<I2S_mode> = 0,1
T5
I2S_CLK low end to I2S_WA high end
-24
31
ns
<I2S_mode> = 0,1
T6
I2S_TX invalid before I2S_CLK low end
24
ns
<I2S_mode> = 0,1
T7
I2S_TX valid after I2S_CLK high begin
22
ns
<I2S_mode> = 0,1
T8
I2S_RX setup time before I2S_CLK high
end
60
ns
<I2S_mode> = 0,1
T9
I2S_RX hold time after I2S_CLK low
begin
12
ns
<I2S_mode> = 0,1
Table 24: AC characteristics of digital audio interface in PCM mode (<I2S_mode> = 0, 1)
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Electrical specifications Page 32 of 49
4.2.12 DDC (I2C) pins
Parameter
Min
Typical
Max
Unit
Remarks
Internal supply for DDC domain
1.75
1.80
1.85
V
Digital I/O Interfaces supply (V_INT)
L-level input
-0.20
0.35
V
In accordance with I2C bus specification
H-level input
1.30
3.30
V
In accordance with I2C bus specification
L-level output
0.00
0.40
V
Max value at IOL = +3.0 mA
Input/Output leakage current
0.7
µA
0.2 V < VIN < 3.3 V
Clock frequency on SCL
100
kHz
Table 25: DDC pins characteristics
4.2.13 Audio pins
Pin Name
Parameter
Min
Typical
Max
Unit
Remarks
MIC_BIAS
Microphone supply
output voltage
2.2
V
Provided by MIC_BIAS output pin with
MIC_GND pin as reference.
Microphone supply
output current
4.0
mA
Provided by MIC_BIAS output pin with
MIC_GND pin as reference
Load capacitance
0
nF
Proper internal bypass capacitor is
already provided to guarantee stable
operation: an external capacitor cannot
be directly connected to MIC_BIAS pin,
but can be provided after a proper
series resistor.
Load resistance
1
k
MIC_GND
Microphone ground
0
V
MIC_GND pin is internally connected to
GND as a sense line
Table 26: Microphone supply (MIC_BIAS) characteristics
Pin Name
Parameter
Min
Typical
Max
Unit
Remarks
MIC_P/MIC_N
Differential input
voltage
0.8
Vpp
Full scale differential voltage
Differential input
resistance
50
k
Common mode DC
voltage
0.5
V
No internal DC blocking capacitor
Input capacitance
5
10
pF
No internal DC blocking capacitor
Signal to noise
75
dB
Gain stage = +12 dB,
Bandwidth 300-3900 Hz
Signal to distortion
(THD)
65
dB
Power supply rejection
49
85
dB
Table 27: Differential audio transmit path (MIC_P, MIC_N) input characteristics
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Electrical specifications Page 33 of 49
Pin Name
Parameter
Min
Typical
Max
Unit
Remarks
SPK_P/SPK_N
Maximum differential
output voltage
4.0
4.1
4.2
Vpp
Full scale differential open circuit
voltage
Common mode output
voltage
1.25
V
Output current limit
200
mA
Output load
resistance
14
Single-ended output
load capacitance
250
pF
Signal to noise
70
80
dB
Load = 16 , Gain stage = +0 dB,
Input signal = 0 dBFS, Code 0, A-
weighted
Signal to distortion
(THD)
60
70
dB
Load = 16 , Input signal = 0 dBFS
Table 28: Differential audio receive path (SPK_P, SPK_N) output characteristics
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Mechanical specifications Page 34 of 49
5 Mechanical specifications
C
R
R
P
Q
KM1 M1 M2
E
G
H1
J1
H
2
J2
J2
H
2
E
ANT
pin
B
Pin 1
Indicator
K
GH1 J1
A
D D
O
O
L
N
L
I
F
F
Figure 8: SARA-G3 series dimensions (bottom and sides views)
Parameter
Description
Typical
Tolerance
A
Module Height [mm]
26.0
(1023.6 mil)
+0.20/-0.20
(+7.9/-7.9 mil)
B
Module Width [mm]
16.0
(629.9 mil)
+0.20/-0.20
(+7.9/-7.9 mil)
C
Module Thickness 26 [mm]
2.4
(94.5 mil)
+0.25/-0.15
(+9.8/-5.9 mil)
D
Horizontal Edge to Lateral Pin Pitch [mm]
2.0
(78.7 mil)
+0.20/-0.20
(+7.9/-7.9 mil)
E
Vertical Edge to Lateral Pin Pitch [mm]
2.5
(98.4 mil)
+0.20/-0.20
(+7.9/-7.9 mil)
F
Edge to Lateral Pin Pitch [mm]
1.05
(41.3 mil)
+0.20/-0.20
(+7.9/-7.9 mil)
G
Lateral Pin to Pin Pitch [mm]
1.1
(43.3 mil)
+0.02/-0.02
(+0.8/-0.8 mil)
H1
Lateral Pin Height [mm]
0.8
(31.5 mil)
+0.02/-0.02
(+0.8/-0.8 mil)
H2
Lateral Pin close to ANT Height [mm]
0.9
(35.4 mil)
+0.02/-0.02
(+0.8/-0.8 mil)
I
Lateral Pin Width [mm]
1.5
(59.1 mil)
+0.02/-0.02
(+0.8/-0.8 mil)
J1
Lateral Pin to Pin Distance [mm]
0.3
(11.8 mil)
+0.02/-0.02
(+0.8/-0.8 mil)
J2
Lateral Pin to Pin close to ANT Distance [mm]
0.2
(7.9 mil)
+0.02/-0.02
(+0.8/-0.8 mil)
K
Horizontal Edge to Central Pin Pitch [mm]
2.75
(108.3 mil)
+0.20/-0.20
(+7.9/-7.9 mil)
L
Vertical Edge to Central Pin Pitch [mm]
2.75
(108.3 mil)
+0.20/-0.20
(+7.9/-7.9 mil)
M1
Central Pin to Pin Horizontal Pitch [mm]
1.8
(70.9 mil)
+0.02/-0.02
(+0.8/-0.8 mil)
M2
Central Pin to Pin Horizontal Pitch [mm]
3.6
(141.7 mil)
+0.02/-0.02
(+0.8/-0.8 mil)
N
Central Pin to Pin Vertical Pitch [mm]
2.1
(82.7 mil)
+0.02/-0.02
(+0.8/-0.8 mil)
O
Central Pin Height and Width [mm]
1.1
(43.3 mil)
+0.02/-0.02
(+0.8/-0.8 mil)
P
Horizontal Edge to Pin 1 Indicator Pitch [mm]
0.9
(35.4 mil)
+0.20/-0.20
(+7.9/-7.9 mil)
Q
Vertical Edge to Pin 1 Indicator Pitch [mm]
1.0
(39.4 mil)
+0.20/-0.20
(+7.9/-7.9 mil)
R
Pin 1 Indicator Height and Width [mm]
0.6
(23.6 mil)
+0.02/-0.02
(+0.8/-0.8 mil)
Weight
Module Weight [g]
< 3
Table 29: SARA-G3 series dimensions
The module height tolerance +/0.20 mm may be exceeded close to the corners of the PCB due
to the cutting process: in the worst cases, the height could be +0.40 mm longer than the typical
value.
For information regarding suggested footprint (i.e. copper mask) and stencil (i.e. paste mask)
layout to be implemented on the application board, see SARA-G3 / SARA-U2 series System
Integration Manual [2].
26
3.0 mm typical module thickness for SARA-G3 modules product versions “00” and “01”
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Qualification and approvals Page 35 of 49
6 Qualification and approvals
6.1 Reliability tests
Tests for product family qualifications are according to ISO 16750 “Road vehicles - Environmental
conditions and testing for electrical and electronic equipment“, and appropriate standards.
6.2 Approvals
6.2.1 SARA-G3 series
Products marked with this lead-free symbol on the product label comply with
the “Directive 2002/95/EC of the European Parliament and the Council on the
Restriction of Use of certain Hazardous Substances in Electrical and Electronic
Equipment“ RoHS).
SARA-G3 series GSM/GPRS modules are RoHS compliant.
No natural rubbers, hygroscopic materials, or materials containing asbestos
are employed.
Table 30 lists the SARA-G3 series modules main approvals.
Certification Scheme
SARA-G300
SARA-G310
SARA-G340
SARA-G350
GCF (Global Certification Forum)
PTCRB (PCS Type Certification Review Board)
CE (Conformité Européenne)
FCC (US Federal Communications Commission)
FCC Identification number
XPYSARAG350
XPYSARAG350
ISED (Innovation, Science and Economic Development
Canada)27
IC certification number
8595A-SARAG350
8595A-SARAG350
Anatel (Agência Nacional de Telecomunicações Brazil)
A-tick / RCM (Australia Regulatory Compliance Mark)
EurAsEC (Eurasian Economic Community Certification)
Ukraine Certification
Israel Certification
China Certification
NCC (National Communications Commission Taiwan)
ICASA (Ind. Communications Authority South Africa)
Vodafone (Network Operator)
Orange (Network Operator)
TIM (Telecom Italia Mobile Network Operator)
Rogers (Canadian Network Operator)
Table 30: SARA-G3 series main certification approvals
For the complete list of approvals and for specific details on all country and network operators’
certifications, see our website (www.u-blox.com) or please contact the u-blox office or sales
representative nearest you.
27
Formerly known as IC (Industry Canada)
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Qualification and approvals Page 36 of 49
6.2.2 SARA-G340 ATEX and SARA-G350 ATEX
SARA-G340 ATEX and SARA-G350 ATEX modules, in addition to the approvals for main certification
schemes (see section 6.2.1), are certified as components intended for use in potentially explosive
atmospheres compliant to the following standards:
IEC 60079-0: 2011
IEC 60079-11: 2011
IEC 60079-26: 2006
The certification number of SARA-G340 ATEX and SARA-G350 ATEX modules according to the
ATEX directive 2014/34/EU is:
SIQ 13 ATEX 032 U
The certification number of SARA-G340 ATEX and SARA-G350 ATEX modules according to the
IECEx conformity assessment system is:
IECEx SIQ 13.0004U
According to the standards listed above, the SARA-G340 ATEX and SARA-G350 ATEX modules are
certified with the following marking:
Ex II 1G, Ex ia IIC/IIB
According to the marking stated above, the SARA-G340 ATEX and SARA-G350 ATEX modules are
certified as electrical equipment of:
group ‘II’: intended for use in areas with explosive gas atmosphere other than mines
susceptible to firedamp
category ‘1G’: intended for use in zone 0 hazardous areas, in which explosive atmospheres
caused by mixtures of air and gases, vapors or mists are present continuously, for long
periods or frequently
level of protection ‘ia’: intrinsically safe apparatus with very high level of protection, not
capable of causing ignition in normal operation and with the application of one countable
fault or a combination of any two countable fault plus those non-countable faults which give
the most onerous condition
subdivision ‘IIC/IIB’: intended for use in areas where the nature of the explosive gas
atmosphere is considered very dangerous based on the Maximum Experimental Safe Gap or
the Minimum Ignition Current ratio of the explosive gas atmosphere in which the equipment
may be installed (a typical gas is hydrogen), so that the modules are also suitable for
applications intended for use in subdivision IIB (typical gas is ethylene) and subdivision IIA (a
typical gas is propane)
Section 4.2.1 defines the temperature range of use of SARA-G340 ATEX and SARA-G350 ATEX
modules.
The RF radiating profile of SARA-G340 ATEX and SARA-G350 ATEX modules is compliant to all the
applicable 3GPP / ETSI standards, with a maximum of 2 W RF pulse power and 1.15 mJ RF pulse
energy according to the GSM/GPRS power class stated in Table 2.
Section 9.1 describes the nameplate of SARA-G340 ATEX and SARA-G350 ATEX modules (see
Figure 12 and Figure 13).
The following maximum input and equivalent parameters must be considered in sub-division IIC:
Ui = 3.8 V
Ii = 1.6 A (burst)
Pi = 2.5 W
Ci = 103 µF
Li = 4.1 µH
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Qualification and approvals Page 37 of 49
The following maximum input and equivalent parameters must be considered in sub-divisions IIB,
IIA:
Ui = 4.2 V
Ii = 2.5 A (burst)
Pi = 2.5 W
Ci = 103 µF
Li = 4.1 µH
For more information about the integration of SARA-G340 ATEX and SARA-G350 ATEX
modules in applications intended for use in potentially explosive atmospheres, see the SARA-G3
/ SARA-U2 Series System Integration Manual [2].
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Product handling Page 38 of 49
7 Product handling
7.1 Packaging
SARA-G3 series modules are delivered as hermetically sealed, reeled tapes to enable efficient
production, production lot set-up and tear-down. For more information about packaging, see the
u-blox Package Information Guide [5].
Figure 9: Reeled SARA-G3 series modules
7.1.1 Reels
SARA-G3 series modules are deliverable in quantities of 250 pieces on a reel. SARA-G3 series
modules are delivered using reel Type B as described in the u-blox Package Information Guide [5].
Parameter
Specification
Reel Type
B
Delivery Quantity
250
Table 31: Reel information for SARA-G3 series modules
Quantities of less than 250 pieces are also available. Contact u-blox for more information.
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Product handling Page 39 of 49
7.1.2 Tapes
Figure 10 specifies the dimensions and orientations of the tapes for SARA-G3 series module.
Figure 10: Dimensions for SARA-G3 series on tape
Parameter
Value
A0
16.8
B0
26.8
K0
3.2
Table 32: SARA-G3 series tape dimensions (mm)
Note 1: 10 sprocket hole pitch cumulative tolerance ± 0.2.
Note 2: Pocket position relative to sprocket hole measured as true position of pocket, not
pocket hole.
Note 3: A0 and B0 are calculated on a plane at a distance “R” above the bottom of the pocket.
7.2 Moisture sensitivity levels
SARA-G3 series modules are Moisture Sensitive Devices (MSD) in accordance to the IPC/JEDEC
specification.
The Moisture Sensitivity Level (MSL) relates to the packaging and handling precautions required.
SARA-G3 series modules are rated at MSL level 4. For more information regarding moisture
sensitivity levels, labeling, storage and drying, see the u-blox Package Information Guide [5].
For MSL standard see IPC/JEDEC J-STD-020 (can be downloaded from www.jedec.org).
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Product handling Page 40 of 49
7.3 Reflow soldering
Reflow profiles are to be selected according to u-blox recommendations (see SARA-G3 / SARA-U2
Series System Integration Manual [2]).
Failure to observe these precautions can result in severe damage to the device!
7.4 ESD precautions
SARA-G3 series modules contain highly sensitive electronic circuitry and are Electrostatic
Sensitive Devices (ESD). Handling SARA-G3 series modules without proper ESD protection may
destroy or damage them permanently.
SARA-G3 series modules are Electrostatic Sensitive Devices (ESD) and require special ESD
precautions typically applied to ESD sensitive components.
Table 8 reports the maximum ESD ratings of the SARA-G3 modules.
Proper ESD handling and packaging procedures must be applied throughout the processing,
handling and operation of any application that incorporates SARA-G3 series modules.
ESD precautions should be implemented on the application board where the module is mounted, as
described in the SARA-G3 / SARA-U2 Series System Integration Manual [2].
Failure to observe these precautions can result in severe damage to the device!
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Default settings Page 41 of 49
8 Default settings
Interface
Settings
Comments
UART interface
AT interface: enabled
AT command interface is by default enabled on the UART physical
interface
AT+IPR=0
Automatic baud rate detection enabled by default
AT+ICF=0
Automatic frame format recognition enabled by default
AT&K3
HW flow control enabled
AT&S1
DSR line set ON in data mode and set OFF in command mode
AT&D1
Upon an ON-to-OFF transition of DTR, the DCE enters online command
state and issues an OK result code
AT&C1
Circuit 109 changes in accordance with the Carrier detect status; ON if the
Carrier is detected, OFF otherwise
MUX protocol:
disabled
Multiplexing mode is by default disabled and it can be configured by
AT+CMUX command.
SARA-G340 and SARA-G350 modules define the following virtual channels:
Channel 0: control channel
Channel 1 5: AT commands / data connection
Channel 6: GNSS tunneling
SARA-G300 and SARA-G310 modules define the following virtual channels:
Channel 0: control channel
Channel 1 2: AT commands / data connection
AUX UART interface
AT interface: disabled
AT command interface is by default disabled on the AUX UART physical
interface, and it can be configured by AT+USIO command (see the u-blox
AT Commands Manual [1])
Power Saving
AT+UPSV=0
Disabled
Network registration
AT+COPS=0
Self network registration
Table 33: SARA-G3 series default settings
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Labeling and ordering information Page 42 of 49
9 Labeling and ordering information
9.1 Product labeling
The labels of SARA-G3 series modules include important product information as described in this
section.
Figure 11 illustrates the label of all the SARA-G3 series modules except for SARA-G340 ATEX and
SARA-G350 ATEX, and includes: u-blox logo, production lot, Pb-free marking, product Type Number,
IMEI number, certification info and production country.
XXXXXXXXXX
XXXXXXXXXX
XXXXX-XXXXXXXX
ANATEL:
xxx-xx
FCC ID:
IC:
Figure 11: Label of SARA-G3 modules (except for SARA-G340 ATEX and SARA-G350 ATEX)
Figure 12 illustrates the label of SARA-G350 ATEX modules, and includes: u-blox logo, production lot,
Pb-free marking, product Type Number, IMEI number, ATEX marking with the IECEx and ATEX
certificate numbers and category classification, FCC and IC certification numbers and production
country.
02X-00
Figure 12: Label of SARA-G350 ATEX modules
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Labeling and ordering information Page 43 of 49
Figure 13 illustrates the label of SARA-G340 ATEX modules, and includes: u-blox logo, production lot,
Pb-free marking, product Type Number, IMEI number, ATEX marking with the IECEx and ATEX
certificate numbers and category classification, Notified Body number and production country.
SARA-G340
02X-00
Figure 13: Label of SARA-G340 ATEX modules
For information about the approval codes and for all the certificates of compliancy of SARA-G3
series modules, see our website (www.u-blox.com) or contact the u-blox office or sales
representative nearest you.
9.2 Explanation of codes
Three different product code formats are used. The Product Name is used in documentation such as
this data sheet and identifies all u-blox products, independent of packaging and quality grade. The
Ordering Code includes options and quality, while the Type Number includes the hardware and
firmware versions. Table 34 below details these three different formats:
Format
Structure
Product Name
SARA-TGVV
Ordering Code
SARA-TGVV-TTQ
Type Number
SARA-TGVV-TTQ-XX
Table 34: Product code formats
Table 35 explains the parts of the product code.
Code
Meaning
Example
SARA
Form factor
SARA
T
Platform [G: GSM; U: HSUPA; C: CDMA 1xRTT; N: NB-IoT;
R: LTE low data rate (Cat 1 and below); L: LTE high data rate (Cat 3 and
above)]
G: GSM
G
Platform generation, e.g. chip or function set [1…9]
3
VV
Variant based on the same platform [00…99]
50
TT
Product Version [00…99]
00
Q
Quality grade / Production site
S = professional / made in Austria
A = automotive / made in Austria
X = ATEX / made in Austria
B = professional / made in Brazil
S
XX
Default value is 00
Table 35: Part identification code
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Labeling and ordering information Page 44 of 49
9.3 Ordering information
Ordering No.
Description
SARA-G300-00S
2-band GSM/GPRS class 10 module
26.0 x 16.0 x 3.0 mm, 250 pcs/reel
SARA-G310-00S
4-band GSM/GPRS class 10 module
26.0 x 16.0 x 3.0 mm, 250 pcs/reel
SARA-G340-00S
2-band GSM/GPRS class 10 module
Supporting Audio, I2C for u-blox GNSS receivers, AssistNow, CellLocate®, Embedded TCP/UDP,
FTP/HTTP/SMTP, eCall / ERA-GLONASS, Network indication, Antenna supervisor, Jamming
detection and other features
26.0 x 16.0 x 3.0 mm, 250 pcs/reel
SARA-G340-01S
2-band GSM/GPRS class 10 module
Supporting the same feature-set of the “00” product version plus SSL for FTP and HTTP, Multi
GNSS Assistance (MGA) server and other features
26.0 x 16.0 x 3.0 mm, 250 pcs/reel
SARA-G340-02S
2-band GSM/GPRS class 10 module
Supporting the same feature-set of the “01” product version plus second AT interface, improved
SSL/TLS, IPv4/IPv6 dual-stack, Bearer Independent Protocol, Network Friendly Mode and other
features
26.0 x 16.0 x 2.4 mm, 250 pcs/reel
SARA-G340-02X
2-band GSM/GPRS class 10 module
Supporting the same feature-set of the “02S” product version
ATEX / IECEx certified
26.0 x 16.0 x 2.4 mm, 250 pcs/reel
SARA-G350-00S
4-band GSM/GPRS class 10 module
Supporting Audio, I2C for u-blox GNSS receivers, AssistNow, CellLocate®, Embedded TCP/UDP,
FTP/HTTP/SMTP, eCall / ERA-GLONASS, Network indication, Antenna supervisor, Jamming
detection and other features
26.0 x 16.0 x 3.0 mm, 250 pcs/reel
SARA-G350-00X
4-band GSM/GPRS class 10 module
Supporting the same feature-set of the “00S” product version
ATEX / IECEx certified
26.0 x 16.0 x 3.0 mm, 250 pcs/reel
SARA-G350-01S
4-band GSM/GPRS class 10 module
Supporting the same feature-set of the “00” product version plus SSL for FTP and HTTP, Multi
GNSS Assistance (MGA) server and other features
26.0 x 16.0 x 3.0 mm, 250 pcs/reel
SARA-G350-01B
4-band GSM/GPRS class 10 module
Supporting the same feature-set of the “01S” product version
Made in Brazil
26.0 x 16.0 x 3.0 mm, 250 pcs/reel
SARA-G350-02S
4-band GSM/GPRS class 10 module
Supporting the same feature-set of the “01” product version plus second AT interface, improved
SSL/TLS, IPv4/IPv6 dual-stack, Bearer Independent Protocol, Network Friendly Mode and other
features
26.0 x 16.0 x 2.4 mm, 250 pcs/reel
SARA-G350-02X
4-band GSM/GPRS class 10 module
Supporting the same feature-set of the “02S” product version
ATEX / IECEx certified
26.0 x 16.0 x 3.0 mm, 250 pcs/reel
Table 36: Product ordering codes
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Appendix Page 45 of 49
Appendix
A Glossary
Abbreviation
Definition
ADC
Analog to Digital Converter
AT
AT Command Interpreter Software Subsystem, or attention
ATEX
Atmospheres Explosive
BB
Base-Band
BER
Bit Error Rate
DCE
Data Communication Equipment
DDC
Display Data Channel (I2C compatible) Interface
DL
Down-link (Reception)
Driver Class
Output Driver Class: see Table 22 for definition
DRX
Discontinuous Reception
DTE
Data Terminal Equipment
ERS
External Reset Input Signal
GDI
Generic Digital Interfaces (power domain)
GND
Ground
GNSS
Global Navigation Satellite System
GPIO
General Purpose Input Output
GPRS
General Packet Radio Service
GPS
Global Positioning System
GSM
Global System for Mobile Communication
H
High logic digital level
HBM
Human Body Model
I2C
Inter-Integrated Circuit Interface
I2S
Inter-IC Sound Interface
L
Low logic digital level
LGA
Land Grid Array
N/A
Not Applicable
OD
Open Drain
PA
Power Amplifier
PCN / IN
Product Change Notification / Information Note
PD
Pull-Down
PMU
Power Management Unit
POS
Power-On Input Signal
PU
Pull-Up
PU/PD Class
Pull-Up / Pull-Down Class: see Table 22 for definition
RMC
Reference Measurement Channel
SIM
Subscriber Identity Module
SPI
Serial Peripheral Interface
T
Tristate (Output of the pin set to tri-state, i.e. high impedance state)
T/PD
Tristate with internal active Pull-Down enabled
T/PU
Tristate with internal active Pull-Up enabled
TBD
To Be Defined
UART
Universal Asynchronous Receiver-Transmitter serial interface
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Appendix Page 46 of 49
Abbreviation
Definition
UL
Up-link (Transmission)
USB
Universal Serial Bus interface
Table 37: Explanation of the abbreviations and terms used
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Related documents Page 47 of 49
Related documents
[1] u-blox AT Commands Manual, Doc. No. UBX-13002752
[2] u-blox SARA-G3 / SARA-U2 Series System Integration Manual, Doc. No. UBX-13000995
[3] u-blox GNSS Implementation Application Note, Doc. No. UBX-13001849
[4] u-blox Mux Implementation Application Note for cellular modules, Doc. No. UBX-13001887
[5] u-blox Package Information Guide, Doc. No. UBX-14001652
[6] u-blox Android RIL Production delivery Application note, Doc. No. UBX-13002041
[7] u-blox Windows Embedded RIL Production delivery Application note, Doc. No. UBX-13002043
[8] ITU-T Recommendation V24, 02-2000. List of definitions for interchange circuits between Data
Terminal Equipment (DTE) and Data Connection Equipment (DCE)
[9] 3GPP TS 27.007 Technical Specification Group Core Network and Terminals; AT command set
for User Equipment (UE)
[10] 3GPP TS 27.005 Technical Specification Group Terminals; Use of Data Terminal Equipment
Data Circuit terminating Equipment (DTE-DCE) interface for Short Message Services (SMS) and
Cell Broadcast Service (CBS)
[11] 3GPP TS 27.010 Terminal Equipment to User Equipment (TE-UE) multiplexer protocol
[12] 3GPP TS 26.267 Technical Specification Group Services and System Aspects; eCall Data
Transfer; In-band modem solution; General description
[13] GSM Association - Official Document CLP.03 - IoT Device Connection Efficiency Guidelines
For regular updates to u-blox documentation and to receive product change notifications,
register on our homepage (www.u-blox.com).
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Revision history Page 48 of 49
Revision history
Revision
Date
Name
Comments
-
Jun. 22, 2012
lpah / sses
Initial release
1
Sep. 05, 2012
sses
Corrected module pin numbering and dimensions
2
Oct. 19, 2012
sses
Added ESD immunity rating for ANT pin; Added current consumption ratings
3
Nov. 07, 2012
sses
Added the technical description of SARA-G300 and SARA-G310 modules
Updated current consumption ratings
4
Mar. 08, 2013
lpah / sses
Updated status to Advance Information
5
Apr. 12, 2013
lpah
Updated status to Preliminary
6
May 23, 2013
lpah
Updated status to Objective Specification; CSD supported by SARA-G300 /
SARA-G310
7
May 27, 2013
lpah
GPRS multi-slot class 10 supported by SARA-G300 / SARA-G310
Last revision with docu number GSM.G2-HW-12001
A
Jul. 05, 2013
sses
Updated status to Advance Information
Added the technical description of SARA-G350 ATEX modules; Added
description of 32K_OUT pin for SARA-G300 / SARA-G310; Updated current
consumption ratings
A1
Jul. 31, 2013
lpah
Updated status to Preliminary
SIM detection not supported by SARA-G300 and SARA-G310 modules
Last revision with old document number GSM.G2-HW-12001
R11
23-Jan-2014
lpah
Updated status to Objective Specification
Extended the document applicability to SARA-G340 modules
R12
30-Jun-2014
mrod
Updated document status to Advance Information.
Extended the document applicability to the SARA-G340-01S, SARA-G350-01S
and SARA-G350-01B modules versions.
Updated information about RIL and USSD.
Updated current consumption ratings with AT+UPSV=0.
R13
17-Oct-2014
mrod
Updated document status to Early Preliminary Information.
R14
14-May-2015
lpah
Updated document status to Preliminary Information.
Updated allowed baud rates for AT interface
R15
15-Dec-2015
sses
Reverted status to Advanced Information
Extended the document applicability to SARA-G3 modules “02” product
versions
R16
29-Jan-2016
sses
Updated document status to Early Preliminary Information.
Added detailed VCC current consumption characteristics and enlarged VCC
supply extended operating voltage range for SARA-G3 modules “02”
product versions.
R17
12-May-2016
sses
Extended the document applicability to SARA-G300-00S-01 /
SARA-G310-00S-01.
Updated the ATEX label.
R18
21-Jul-2016
lpah
Extended the document applicability to SARA-G340 ATEX module
R19
24-Apr-2017
lpah
"Disclosure restriction" replaces "Document status" on page 2 and document
footer
R20
03-Aug-2017
lpah
Extended document applicability to SARA-G350-02X
Updated label and approvals information
R21
27-Mar-2018
lpah
Extended document applicability to SARA-G340-02S-01, SARA-G340-02X-01,
SARA-G350-02S-01, SARA-G350-02X-01
SARA-G3 series - Data Sheet
UBX-13000993 - R21 Contact Page 49 of 49
Contact
For complete contact information, visit us at www.u-blox.com.
u-blox Offices
North, Central and South America
u-blox America, Inc.
Phone: +1 703 483 3180
E-mail: info_us@u-blox.com
Regional Office West Coast:
Phone: +1 408 573 3640
E-mail: info_us@u-blox.com
Technical Support:
Phone: +1 703 483 3185
E-mail: support@u-blox.com
Headquarters
Europe, Middle East, Africa
u-blox AG
Phone: +41 44 722 74 44
E-mail: info@u-blox.com
Support: support@u-blox.com
Asia, Australia, Pacific
u-blox Singapore Pte. Ltd.
Phone: +65 6734 3811
E-mail: info_ap@u-blox.com
Support: support_ap@u-blox.com
Regional Office Australia:
Phone: +61 2 8448 2016
E-mail: info_anz@u-blox.com
Support: support_ap@u-blox.com
Regional Office China (Beijing):
Phone: +86 10 68 133 545
E-mail: info_cn@u-blox.com
Support: support_cn@u-blox.com
Regional Office China (Chongqing):
Phone: +86 23 6815 1588
E-mail: info_cn@u-blox.com
Support: support_cn@u-blox.com
Regional Office China (Shanghai):
Phone: +86 21 6090 4832
E-mail: info_cn@u-blox.com
Support: support_cn@u-blox.com
Regional Office China (Shenzhen):
Phone: +86 755 8627 1083
E-mail: info_cn@u-blox.com
Support: support_cn@u-blox.com
Regional Office India:
Phone: +91 80 405 092 00
E-mail: info_in@u-blox.com
Support: support_in@u-blox.com
Regional Office Japan (Osaka):
Phone: +81 6 6941 3660
E-mail: info_jp@u-blox.com
Support: support_jp@u-blox.com
Regional Office Japan (Tokyo):
Phone: +81 3 5775 3850
E-mail: info_jp@u-blox.com
Support: support_jp@u-blox.com
Regional Office Korea:
Phone: +82 2 542 0861
E-mail: info_kr@u-blox.com
Support: support_kr@u-blox.com
Regional Office Taiwan:
Phone: +886 2 2657 1090
E-mail: info_tw@u-blox.com