SSR/SSRT Series TELEDYNE RELAYS SINGLE SCR OR TRIAC OUTPUT TO 125 AMPS 1600 VOLTS Industrial Solid State Products PART NUMBERS Package & Chip Type Max Blocking Input Type Voltage (piv)/ Line Rating SSRT-Triac 600240 SSR-SCR 1600660 1200480 600240 Output Current Amps D-DC Input, 10-Triac Zero Cross 25-Triac Switching 25 R-DC Input, 40 Random 55 Turn-On 75 A-AC Input, Zero 90 Cross Switching 125 (600240/1200480 only) Options See Table Below and Page 40 Options (Add Suffix to Part Number) - See Page 40 for full description -016 MOV -002 Control Status LED -021 TransAxTM (Available for D -006 Faston Terminals or R input SCR output only) -010 #8-32 Load Terminal -022 24 VAC Control Hardware -023 0.1" Mounting Flange -012 EZ MountTM -027 VDE Certified Model -014 Plastic Cover Contact factory for certified -034 part numbers. Polarized input/output terminals Part Number Example: SSR1200480D125 MECHANICAL SPECIFICATION FEATURES/BENEFITS * Industry Standard Package. * Floating screw type terminals in a high temperature plastic housing for exceptional ruggedness. * Triac output option for economy; Back-to-Back SCR output option for higher current and voltage ratings. * Constant Current Input minimizes source current requirement (standard on D and A inputs only) * Exposed ceramic baseplate for reduced thermal resistance and best thermal performance. * Constructed using Teledyne's unique PowerthermTM or Fused CopperTM (for higher current models) processes. These processes yield superior thermal impedance and power cycling capabilities through reduced thermal interconnections, allowing for cooler, more reliable operation. * Optional TransAXTM transient eliminator offers up to 6000V Protection! * Certifications: - UL and ULC Recognized File #E128555 - CE # EN60947-1 - VDE # 5928 (for applicable part numbers, see Option -027 on page 40). TYPICAL APPLICATIONS C L See page 42 for mounting information. BLOCK DIAGRAM * On/Off controls of medium power AC equipment. * Interfacing of microprocessor controls to AC loads - lights, motors, heaters, valves, solenoids etc. * Electromechanical line relay replacement. * Industrial and Process Controls. * Uninterruptable Power Supplies. * Robotics motor position and speed controls. * Light dimmers. * Transformer tap switch. * Phase Proportional Drives GENERAL DESCRIPTION The SS/SSRT series AC Solid State Relays are designed to control heavy loads. Optical isolation ensures complete protection of control elements from load transients. Teledyne's advanced design featuring the PowerthermTM or Fused CopperTM process offers users superior thermal management resulting in superior performance, quality and reliability. page 6 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. SSR/SSRT Series TELEDYNE RELAYS Industrial Solid State Products SINGLE SCR OR TRIAC OUTPUT TO 125 AMPS 1600 VOLTS ELECTRICAL SPECIFICATIONS INPUT (CONTROL) SPECIFICATIONS Load Voltage/ Input Code Parameter Control Voltage Range Input Current OUTPUT (LOAD) SPECIFICATIONS (Contd) Min 600240D 3 32 1200480D 3 32 1600660D 4.5 32 600240R 4 26 1200480R 4 26 1600660R 5 26 A (Note 4) 90 280 D,R(@5Vdc) 15 A(@90Vac) (Note 4) Must Turn-Off Voltage D,R Reverse Voltage 10 A (Note 4) A (Note 4) 2.5 0.5 1.0 Weight (typical) 3.0 oz (85g) 25 0.05 25 40 0.05 40 55 0.05 55 75 0.05 75 90 0.05 125 Load Voltage Rating Min Max 600240 24 280 1200480 48 530 1600660 60 660 Frequency Range (Note 2) Triac Output SCR Output 47 400 90 10 100 25 250 40 400 55 600 75 800 90 1000 125 Vac Over Voltage Range 10 Triac Output 1.1 25 Triac Output 1.1 Hz Thermal Resistance 25 SCR Output 0.4 Junction to Case (JC) 40 SCR Output 0.4 600 1200480 1200 1600660 1600 On-State Voltage Drop Triac Output 1.5 @ Max Rated Current SCR Output 1.4 Turn-On Time Leakage Current (Off-State) @rated voltage; 60hz VPeak V ms R 0.02 ms 8.3 ms 0.5 mA SSR = 1600660 with -021 option 90 SCR Output 0.33 125 SCR Output 8.3 SSRT = C/W 75 SCR Output 0.3 D,A Turn-Off Time A 1400 55 SCR Output 0.4 600240 A 125 (Non-Repetitive Units 70 47 0.05 Surge Current Rating 16.7 mS) Voltage Code 10 (Base temp @85C) OUTPUT (LOAD) SPECIFICATION Parameter 0.05 Output Current Rating Vdc mA(AC) C Power Factor Range mA mA(DC) Units 125 10 Vac Max -55 N/A 0.25 Output Current Min Storage Ambient Temperature Vac -32 D,R Vdc Parameter Vdc D,R Turn-Off Current Units 15 1 A (Note 4) Protection Max 5 mA 20 mA 500 V/s 0.25 NOTES: 1.) Where overvoltage transient spikes are present, suppression may be required. A suppressor and/or a snubber circuit across the AC terminals of the module will provide additional transient immunity. 2.) For 400 Hz inductive load, contact factory. 3.) All parameters at 25C unless otherwise noted. 4.) AC input not available for 1600660 model. dV/dt (Typical) Dielectric Strength (60 hz) 4000 V Insulation Resistance (500Vdc) 109 y Operating Ambient Temperature -40 100 C Industrial Solid State Products * 800-284-7007 * www.teledynerelays.com page 7