201 Digital Laser Sensor Amplifier-separated LS-500 SERIES FIBER SENSORS Related Information LASER SENSORS General terms and conditions.............. F-3 SC-GU3......................................... P.971~ About laser beam........................ P.1593~ Selection guide.............................. P.169~ Glossary of terms / General precautions........ P.1549~ / P.1552~ PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Conforming to FDA regulations AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS This product is classified as a Class 1 Laser Product in IEC / JIS standards and in FDA* regulations. Do not look at the laser beam through optical system such as a lens. PARTICULAR USE SENSORS *This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS diagnosis MEASUREMENT SENSORS Self-diagnosis PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS Industry's smallest* Industry's smallest* + Stainless steel (SUS) enclosure Stainless steel (SUS) body Featuring stainless steel (SUS) enclosure that won't break when bumped during installation or maintenance. One-point M6 installation The LS-H101 features an easy-to-install design. UV CURING SYSTEMS Body: Stainless steel (SUS) Actual size Selection Guide Amplifier Built-in Amplifierseparated LS-500 LS-400 *Amplifier-separated type laser sensor head as of September 2014, in-company survey Operation indicator (receiver only) PNP output type available Timer Light intensity Interference Automatic monitor prevention sensitivity setting *Amplifier-separated type laser sensor head as of September 2014, in-company survey LS-H101 1 m 3.281 ft sensing range (In STD amplifier response time mode) Beam-emitting part o2 o2.3 o3.5 o0.079 o0.091 o0.138 o5 o0.197 5 LASER MARKERS Test input panasonic.net/id/pidsx/global STATIC CONTROL DEVICES 100 3.937 500 19.685 1,000 39.370 Unit: mm in M6 30 mm 1.181 in Industry's smallest* + IP67 Waterproof IP67 Featuring waterproof IP67 to allow use in the presence of large amounts of water or dust. Simple positioning Check the optimal receiving location at a glance while watching the red spot on the beam axis adjustment screen. *Amplifier-separated type laser sensor head as of September 2014, in-company survey LS-H102 Two-point installation The thru-beam type LS-H102 features the same form as the EX-L200 amplifier built-in ultra-compact laser sensor. And it can be used as an EX-L200 with a digital indicator. Installation pitch 13 mm 0.512 in LS-H102 1 m 3.281 ft sensing range (In STD amplifier response time mode) The LS-H102 delivers sufficient sensing range for use with 450 mm 17.717 in wafers. EX-L211 / EX-L212 Same installation pitch as the EX-L200 series Digital Laser Sensor LS-500 SERIES APPLICATIONS 202 FIBER SENSORS Lead frame position detection Wafer inclination detection IC float detection LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS Detection of workpieces through a workbench Detection of gaskets in caps Detection of the top of DVDs, substrate, etc. PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS Gasket STATIC CONTROL DEVICES LASER MARKERS *Amplifier-separated type laser sensor head as of September 2014, in-company survey Industry's smallest* + Thinnest profile Featuring a 60% smaller design (by volume) than previous coaxial reflective models Our smallest unit is smaller in every dimension at just W8 x H23 x D18 mm W0.315 x H0.906 x D0.709 in (excluding indicators). LS-H201 HUMAN MACHINE INTERFACES 18mm 0.709 in ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS 23mm 0.906 in UV CURING SYSTEMS 8mm 0.315 in Coaxial design By using a laser with high linearity in a coaxial design, the LS-H201 is able to deliver stable sensing in confined spaces as well as simple installation. Reflective surface Emitting element Reflective photoelectric sensor Laser light Sensing object Reflected light Emitting part Receiving part Coaxial design Receiving lens Receiving element Coaxial principle Receiving part Small, long-range spot Easy-to-see operation indicator The LS-H201 produces a spot with a diameter of 2 mm 0.079 in at a sensing range of up to 300 mm 11.811 in (in STD amplifier response time mode). The LS-H201's operation indicator is visible from all directions. 300 mm 11.811 in o2 mm o0.079 in PLC Selection Guide Amplifier Built-in Amplifierseparated LS-500 LS-400 203 LS-500 SERIES Digital Laser Sensor *Amplifier-separated type laser sensor head as of September 2014, in-company survey Industry's smallest* + Horizontal symmetry FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS LS-H901 Horizontal symmetry Featuring a simple system design process thanks to a light source that is placed in the center of the sensor head and a coaxial design. Industry's smallest* and thinnest design Sensing range of 10 mm to 1 m 0.394 in to 3.281 ft (In STD amplifier response time mode) The LS-H901 supports close-range sensing The LS-H901 is even thinner than previous models, measuring just W8 x H23 (excluding indicators) x D18 mm W0.315 x H0.906 x D0.709 in. 8 mm 0.315 in AREA SENSORS 4 mm 0.157 in SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS 10 mm 0.394 in 1 m 3.281 ft PARTICULAR USE SENSORS SENSOR OPTIONS *Amplifier-separated type laser sensor head as of September 2014, in-company survey SIMPLE WIRE-SAVING UNITS Among industry's fastest response times* 60 s WIRE-SAVING SYSTEMS Maximum compatibility with fiber sensors Stable sensing over the long term The LS-500 series features the same operation, menu displays, and form factor as the FX-500 series for increased compatibility with fiber sensors. The LS-500's threshold-tracking function helps maintain stable sensing over the long term and reduce maintenance man-hours. The incident light intensity can be checked and the threshold automatically reset at a user-selected interval to track changes in light intensity due to environmental changes (such as dust, etc.) over extended periods of time. MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC FX-500 series fiber sensor LS-500 series laser sensor FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in Amplifierseparated LS-501 Logic operations HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS *Amplifier-separated type laser sensor head as of September 2014, in-company survey Detection of beam axis misalignment Dual outputs (self-diagnosis output) The LS-500 series can detect any reduction in incident light intensity, for example due to the accumulation of dirt such as dust, and issue an alarm. Sensing output 2 can be set as self-diagnosis output. When you teach the threshold for sensing output 1, sensing output 2 is set accordingly, allowing you to shift the threshold by a previously set margin. The LS-500's ability to perform three logic operations (AND, OR, and XOR) on a standalone basis eliminates the need for a dedicated controller, cuts down on wiring, and lowers costs. This functionality can also be combined with the FX-500 series. Data bank Eight sets of amplifier settings can be stored in the unit's built-in memory. The ability to save and load settings reduces workload when changing the setup in a multimodel production environment. LS-501 Network communication possible Can connect to Open Network CC-Link IE Field / CC-Link / DeviceNet / EtherCAT via Communication Unit for Open Network SC-GU3 series. Monitoring and various settings can be done from PLC, PC, etc. LS-500 LS-400 Current values of connected sensors are shown. 1ch 90 65 9ch 0 0 2ch 50 0 10ch 0 0 3ch 40 70 11ch 0 0 4ch 0 0 12ch 0 0 5ch 0 0 13ch 0 0 6ch 0 0 14ch 0 0 7ch 0 0 15ch 0 0 8ch 0 0 16ch 0 0 End unit [Touch panel display example] Threshold values of connected sensors are shown. Communication Unit for Open Network SC-GU3 series Digital laser sensor Digital fiber sensor Digital fiber sensor Digital pressure sensor LS-403/501 FX-501/502 FX-301/305 DPS-401/402 *CC-Link and CC-Link IE Field are a registered trademark of Mitsubishi Electric Corporation. DeviceNet is a registered trademark of ODVA (Open DeviceNet Vender Association, Inc.). EtherCAT is a registered trademark of Beckhoff Automation GmbH. *Refer to p.971~ for details of SC-GU3 series. Digital Laser Sensor LS-500 SERIES ORDER GUIDE FIBER SENSORS LASER SENSORS Sensor heads Thru-beam type Type 204 Appearance Model No. LS-H101 Cylindrical LS-H102 Square Coaxial reflective type LS-H201 Coaxial retroreflective type Sensing range : HYPR : U-LG : LONG : STD : FAST : H-SP 1 m 3.281 ft 1 m 3.281 ft 1 m 3.281 ft 1 m 3.281 ft 1 m 3.281 ft 1 m 3.281 ft 1 m 3.281 ft 1 m 3.281 ft 1 m 3.281 ft 1 m 3.281 ft 1 m 3.281 ft 1 m 3.281 ft 750 mm 29.528 in 600 mm 23.622 in 450 mm 17.717 in 300 mm 11.811 in 200 mm 7.874 in 150 mm 5.906 in SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS 5 m 16.404 ft cable length type 5 m 16.404 ft cable length types (Standard: 2 m 6.562 ft) are available. When ordering this type, suffix "-C5" to the model No. LS-H101-C5 LS-H102-C5 LS-H201-C5 MICRO PHOTOELECTRIC SENSORS AREA SENSORS 0.01 to 2.5 m 0.033 to 8.202 ft 0.01 to 2 m 0.033 to 6.562 ft 0.01 to 1.5m 0.033 to 4.921 ft 0.01 to 1m 0.033 to 3.281 ft 0.01 to 1m 0.033 to 3.281 ft 0.01 to 1m 0.033 to 3.281 ft LS-H901 PHOTOELECTRIC SENSORS LS-H901-C5 SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS Package without reflector The LS-H901 is also available without a reflector (RF-330). When ordering this type, suffix "-Y" to the model No. PLC LS-H901-Y HUMAN MACHINE INTERFACES Amplifiers ENERGY MANAGEMENT SOLUTIONS Type Appearance Connector type Cable type With external input Model No. Output LS-501 NPN open-collector transistor two outputs LS-501P PNP open-collector transistor two outputs LS-501-C2 NPN open-collector transistor two outputs LS-501P-C2 PNP open-collector transistor two outputs Connection method MACHINE VISION SYSTEMS Use quick-connection cable (optional) Appearance Model No. CN-74-C1 Main cable (4-core) Sub cable (2-core) Selection Guide Connector for amplifier Appearance Amplifierseparated LS-500 Length: 1 m 3.281 ft CN-74-C2 Length: 2 m 6.562 ft CN-74-C5 Length: 5 m 16.404 ft CN-72-C1 Length: 1 m 3.281 ft CN-72-C2 Length: 2 m 6.562 ft CN-72-C5 Length: 5 m 16.404 ft Model No. CN-EP4 Amplifier Built-in Description 0.2 mm2 4-core cabtyre cable, with connector on one end Cable outer diameter: o3.3 mm o0.130 in 0.2 mm2 2-core cabtyre cable, with connector on one end Cable outer diameter: o3.3 mm o0.130 in Connectable to a main cable up to 15 cables Connector Type UV CURING SYSTEMS 2 m 6.562 ft cabtyre cable (6-core) included Cable outer diameter: o4 mm o0.157 in Quick-connection cables Quick-connection cable is not supplied with the connector type amplifier. Please order it separately. Type FA COMPONENTS Description Connector included with sensor head Use for maintenance, for example when another connector is damaged. Five pcs. per set LS-400 205 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS Digital Laser Sensor LS-500 SERIES ORDER GUIDE End plates End plates are not supplied with the amplifier. Please order them separately when the amplifiers are mounted in cascade. Appearance Model No. MICRO PHOTOELECTRIC SENSORS MS-DIN-E AREA SENSORS INDUCTIVE PROXIMITY SENSORS When cascading multiple amplifiers, or when it moves depending on the way it is installed on a DIN rail, these end plates clamp amplifiers into place on both sides. Make sure to use end plates when cascading multiple amplifiers together. Two pcs. per set SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS Description Accessories MS-LS-1 (Sensor head mounting bracket) For LS-H201 / LS-H901 RF-330 (Reflector) MS-EXL2-2 (Mounting plate for thru-beam type) PARTICULAR USE SENSORS 13 mm 0.512 in SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES Mounting plate MS-EXL2-2 (Accessory) Foot angled mounting t 0.8 mm t 0.031 in 8.2 mm 0.323 in Back angled mounting Material: Stainless steel (SUS304) Two M2 (length 12 mm 0.472 in) screws with washers [stainless steel (SUS)] are attached. M3 screw (Purchase separately.) Material: Stainless steel (SUS304) OPTIONS LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Designation LS-500 Description MS-EXL2-5 For LS-H102 (square side sensing type) Foot angled mounting bracket For LS-H102 (square side sensing type) Universal sensor mounting bracket For LS-H102 (square side sensing type) Back angled mounting bracket Amplifier mounting bracket MS-DIN-2 Mounting bracket for amplifier Amplifier protective seal FX-MB1 10 sets of 2 communication window seals and 1 connector seal Communication window seal: It prevents malfunction due to transmission signal from another amplifier, as well as, prevents effect on another amplifier. Connector seal: It prevents contact of any metal, etc., with the pins of the quick-connection cable. Reflector RF-310 For coaxial retroreflective type Compact reflector RF-31 For coaxial retroreflective type Size: 9.2 x 9.2 x t 0.4 mm 0.362 x 0.362 x t 0.016 in For coaxial retroreflective type Size: 25.2 x 27.8 x t 0.4 mm 0.992 x 1.094 x t 0.016 in Sensor head mounting bracket Reflective tape Amplifier Built-in Amplifierseparated Model No. MS-EXL2-1 MS-EXL2-4 RF-33 Sensor head mounting bracket * MS-EXL2-4 * MS-EXL2-1 Adjustment 3 LS-400 360 rotation Move vertically 15 mm 0.591 in Material: Stainless steel (SUS304) Two M3 (length 14 mm 0.551 in) screws with washers [stainless steel (SUS)] are attached. * MS-EXL2-5 Material: Die-cast zinc alloy Sensing range: 0.01 to 1 m 0.033 to 3.281 ft Sensing range: Same as the RF-330. Reflector Reflective tape * RF-310 * RF-33 12 mm 0.472 in 4 mm 0.157 in 24 mm 0.945 in 27.8 mm 1.094 in 0.4 mm 0.016 in * RF-31 Material: Stainless steel (SUS304) Two M3 (length 14 mm 0.551 in) screws with washers [stainless steel (SUS)] are attached. 25.2 mm 0.992 in 9.2 mm 0.362 in 0.4 mm 0.016 in Two M3 (length 14 mm 0.551 in) screws with washers [stainless steel (SUS)], one M3 (length 10 mm 0.394 in) hexagon-socket-head bolt [stainless steel (SUS)], and one M3 hexagon nut [stainless steel (SUS)] are attached. Amplifier mounting bracket * MS-DIN-2 Amplifier protective seal * FX-MB1 Communication window seal Connector seal 9.2 mm 0.362 in Digital Laser Sensor LS-500 SERIES SPECIFICATIONS FIBER SENSORS Sensor heads LASER SENSORS Type Model No. Item Thru-beam type Cylindrical Square Coaxial reflective type LS-H101 LS-H102 LS-H201 Sensing range (Note 3,4) 1 m 3.281 ft 1 m 3.281 ft 150 mm 5.906 in 0.01 to 1 m 0.033 to 3.281 ft FAST 1 m 3.281 ft 1 m 3.281 ft 200 mm 7.874 in 0.01 to 1 m 0.033 to 3.281 ft STD 1 m 3.281 ft 1 m 3.281 ft 300 mm 11.811 in 0.01 to 1 m 0.033 to 3.281 ft LONG 1 m 3.281 ft 1 m 3.281 ft 450 mm 17.717 in 0.01 to 1.5 m 0.033 to 4.921 ft U-LG 1 m 3.281 ft 1 m 3.281 ft 600 mm 23.622 in 0.01 to 2 m 0.033 to 6.562 ft HYPR 1 m 3.281 ft 1 m 3.281 ft 750 mm 29.528 in 0.01 to 2.5 m 0.033 to 8.202 ft o5 mm o0.197 in approx. or less at a distance from the emitter of 1 m 3.281 ft o5 mm o0.197 in approx. or less at a distance from the emitter of 1 m 3.281 ft o2 mm o0.079 in approx. or less at a distance from the sensor head of 300 mm 11.811 in o6 mm o0.236 in approx. or less at a distance from the sensor head of 1 m 3.281 ft Sensing object Opaque, translucent, or transparent object (Note 5) Operation indicator Protection Ambient temperature IP67 (IEC) IP40 (IEC) IP40 (IEC) -10 to +55 C +14 to +131 F (No dew condensation or icing allowed), Storage: -20 to +70 C -4 to +158 F Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Ambient illuminance Incandescent light: 3,000 x or less at the light-receiving face Voltage withstandability Insulation resistance 20 M, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each 100 m/s acceleration (10 G approx.) in X, Y and Z directions three times each 2 Type 660 nm 0.026 mil Laser class Material Enclosure: Stainless steel (SUS303) Cover: Polycarbonate 2 mW Enclosure: PBT Cover: Acrylic Cable 0.09 mm2 2-core shielded cable, 2 m 6.562 ft long (Note 7) Weight Net weight: 50 g approx. Gross weight: 75 g approx. Accessories M6 screw: 4 pcs. Toothed lock washer: 2 pcs. Net weight: 50 g approx. Gross weight: 70 g approx. MS-EXL2-2 (Mounting plate): 2 pcs. 2 mW INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS MEASUREMENT SENSORS STATIC CONTROL DEVICES PLC HUMAN MACHINE INTERFACES FA COMPONENTS Class 1 [IEC / JIS / FDA (Note 6)] 2 mW PRESSURE / FLOW SENSORS ENERGY MANAGEMENT SOLUTIONS Red semiconductor laser diode Peak emission wavelength SAFETY LIGHT CURTAINS / SAFETY COMPONENTS LASER MARKERS 1,000 V AC for one min. between all supply terminals connected together and enclosure Shock resistance MICRO PHOTOELECTRIC SENSORS WIRE-SAVING SYSTEMS Orange LED (lights up when the amplifier output is ON) IP40 (IEC) PHOTOELECTRIC SENSORS AREA SENSORS H-SP Spot size Environmental resistance LS-H901 LS-501(P), LS-501(P)-C2 (Note 2) Applicable amplifiers Emitting element Coaxial retroreflective type EMC Directive, RoHS Directive CE marking directive compliance Max. output 206 1 mW Enclosure: PBT, Indicator cover: Polycarbonate Beam-emitting/receiving surfaces: Glass MACHINE VISION SYSTEMS UV CURING SYSTEMS 0.15 mm2, 2-core two parallel shielded cables, 2 m 6.562 ft long (Note 7) Net weight: 50 g approx. Gross weight: 80 g approx. MS-LS-1 (Mounting bracket): 1pc. Net weight: 50 g approx. Gross weight: 85 g approx. MS-LS-1 (Mounting bracket): 1pc. RF-330 (Refrector): 1pc. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 C +73.4 F. 2) When using the thru-beam type LS-H101 or LS-H102, do not set the receiving light sensitivity (gctL) of the applicable LS-500 series amplifier to level 2 or less. This is because there is a possibility of sensing becoming unstable. 3) The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 x 100 mm 3.937 x 3.937 in) as the object. 4) The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit's receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold. 5) Make sure to confirm detection with an actual sensor before use. 6) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). 7) Cable cannot be extended. Selection Guide Amplifier Built-in Amplifierseparated LS-500 LS-400 207 FIBER SENSORS LASER SENSORS Digital Laser Sensor SPECIFICATIONS Amplifiers Type Model No. PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Item AREA SENSORS Supply voltage SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS SIMPLE WIRE-SAVING UNITS Connector type Cable type NPN output LS-501 LS-501-C2 PNP output LS-501P LS-501P-C2 CE marking directive compliance Power consumption Sensing outputs (Sensing output 1, 2) (Note 4) Output operation PARTICULAR USE SENSORS SENSOR OPTIONS LS-500 SERIES EMC Directive, RoHS Directive 12 to 24 V DC Sensing output setting Sensing output 2 (Note 4) Response time NPN open-collector transistor * Maximum sink current: 50 mA (Note 2) * Applied voltage: 30 V DC or less (between output and 0 V) * Residual voltage: 2 V or less (at max. sink current) Incorporated Normal mode, differential mode, hysteresis mode, window comparator mode, selectable Normal mode, differential mode, hysteresis mode, self-diagnosis output mode, selectable H-SP: 60 s or less, FAST: 150 s or less, STD: 250 s or less, LONG: 500 s or less, U-LG: 5 ms or less, HYPR: 24 ms or less , selectable Monitor current output External input (Note 4) PNP non-contact input NPN non-contact input * Signal condition High: +4 V to +V DC (sink current 3.0 mA or less), * Signal condition High: +8 V to +V DC or open, Low: 0 to +2 V DC (source current 0.5 mA or less) Low: 0 to +0.6 V DC or open * Input impedance: 10 k approx. * Input impedance: 10 k approx. PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS External input function Sensing output operation indicator Laser emission indicator Output select indicator Digital display Incident light indication range Laser emission halt / teaching (full-auto teaching, limit teaching, 2 point teaching) / logic operation setting / copy lock / display adjustment / data bank load / data bank save, selectable Orange LED (lights up when sensing output 1 or sensing output 2 is ON) Green LED (lights up during laser emission) Yellow LED (lights up when output is selected) 8-digit 7-segment digital display (4-digit green LED + 4-digit red LED), MODE indicator (Yellow LED): L/D, CUST, PRO H-SP / FAST / STD: 0 to 4,000, LONG / U-LG / HYPR: 0 to 9,999 Sensitivity setting 2-level teaching / limit teaching / full auto teaching / manual adjustment Logical operation Between sensing output 1 and calculation target: Disabled / AND / OR / XOR, selectable Calculation target: Sensing output 2 / adjacent upstream amplifier (sensing output 1) / external input, selectable Timer functions Selection Guide Amplifier Built-in Amplifierseparated LS-500 Normal mode, differential mode, hysteresis mode, self-diagnosis output mode, answer-back output mode, selectable Output current: Approx. 4 to 20 mA (H-SP, FAST, STD: at 0 to 4,000 indication) Response time: 2 ms or less Zero point: 4 mA 1 % F.S. Span: 16 mA 5 % F.S. Linearity: 3 % F.S. Load resistance: 0 to 250 STATIC CONTROL DEVICES LASER MARKERS PNP open-collector transistor * Maximum source current: 50 mA (Note 2) * Applied voltage: 30 V DC or less (between output and +V) * Residual voltage: 2 V or less (at max. source current) Selectable either Light-ON or Dark-ON WIRE-SAVING SYSTEMS MEASUREMENT SENSORS % Ripple P-P 10 % or less Normal operation: 1,200 mW or less (Current consumption 50 mA or less at 24 V supply voltage,Cable type: excluding monitor current output) ECO mode: 980 mW or less (Current consumption 40 mA or less at 24 V supply voltage,Cable type: excluding monitor current output) Short-circuit protection Sensing output 1 +10 -15 Timer period Interference prevention function OFF-delay timer, ON-delay timer, One-shot timer, ON/OFF-delay timer, ON-delay / One-shot timer, switchable either effective or ineffective, with variable timer period OFF-delay timer, ON-delay timer, One-shot timer, switchable either effective or ineffective, with variable timer period Timer range "ms": 0.5 ms approx., 1 to 9,999 ms approx., in approx. 1 ms intervals Timer range "sec": 0.5 sec. approx., 1 to 32 sec. approx., in approx. 1 sec. intervals Timer range "1/10 ms": 0.05 ms approx., 0.1 to 999.9 ms approx., in approx. 0.1 ms intervals, Set separately for each output. Incorporated (Note 3) Protection Environmental resistance LS-400 Ambient temperature Ambient humidity Voltage withstandability IP40 (IEC) - 10 to +55C +14 to +131 F (If 4 to 7 units are mounted close together, - 10 to +50C +14 to +122 F; if 8 to 16 units (cable type: 8 to 12 units) are mounted close together, - 10 to +45 C +14 to +113F) (No dew condensation or icing allowed), Storage: - 20 to +70 C - 4 to +158 F 35 to 85 % RH, Storage: 35 to 85 % RH 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 20 M, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in (max. 10 G) double amplitude in X, Y and Z directions for two hours each Shock resistance 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each Enclosure: Polycarbonate, Cover: Polycarbonate, Switch: Polyacetal Material Cable 0.2 mm2 6-core cabtyre cable, 2 m 6.562 ft long Cable extension Net weight: 15 g approx., Gross weight: 55 g approx. Weight Accessory Notes: 1) 2) 3) 4) Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. Net weight: 75 g approx., Gross weight: 110 g approx. FX-MB1 (Amplifier protective seal): 1 set Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 C +73.4 F. 25 mA if 5 or more amplifier are connected in cascade (excluding cable extension). Number of units that can be mounted close together: 0 for H-SP; 2 for FAST; 4 for STD, LONG, U-LG, or HYPR Select either sensing output 2 or external input as the connector type. Digital Laser Sensor LS-500 SERIES 208 I/O CIRCUIT AND WIRING DIAGRAMS FIBER SENSORS I/O circuit diagrams LASER SENSORS NPN output type Connector type Terminal No. of connector type D1 1 D3 Tr1 PHOTOELECTRIC SENSORS Cable type 3 Color code of quick-connection cable Color code D1 (Brown) +V (Note 1) +3.3 V Load Load (Black) Sensing output 1 10 k ZD1 +3.3 V 50 mA max. 4 (White) Sensing output 2/ external input D4 ZD2 + 12 to 24 V DC +10 -15 % - *1 10 k D2 Sensor circuit Sensor circuit 50 mA max. Tr2 D2 D3 Tr1 D4 Tr2 ZD1 1 6 3 4 (Blue) 0 V (Note 1) Internal circuit 5 Users' circuit Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V (blue). The power is supplied from the connector of the main cable. 2) Wiring when sensing output 2 is selected is shown with solid lines. Wiring when external input is selected is shown with broken lines. Symbols ... D1, D2, D3, D4: Reverse supply polarity protection diode ZD1, ZD2: Surge absorption zener diode Tr1, Tr2 : NPN output transistor AREA SENSORS Load SAFETY LIGHT + (Black) Sensing output 1 12 to 24 V DC CURTAINS / +10 SAFETY -15 % COMPONENTS - 50 mA max. (White) Sensing output 2 PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS (Blue) 0 V Load (Gray) Monitor output Internal circuit *1 Load (Pink) External input 50 mA max. ZD2 2 2 MICRO PHOTOELECTRIC SENSORS (Brown) +V Users' circuit SENSOR OPTIONS Non-voltage contact or NPN open-collector transistor * External input High: +8 V to +V, or open or Low: 0 to +2 V (source current: 0.5 mA or less) * Light emission halts and teaching occurs when at Low. PNP output type Connector type 0V 10 k D2 ZD1 ZD2 1 (Brown) +V (Note 1) D1 *1 (White) Sensing output 2/ external input 4 50 mA max. + 50 mA max. Tr4 3 D4 2 12 to 24 V DC +10 -15 % - Tr1 Tr2 1 0V (Blue) 0 V (Note 1) Internal circuit D4 D2 3 4 6 2 Load Load 5 Users' circuit Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V (blue). The power is supplied from the connector of the main cable. 2) Wiring when sensing output 2 is selected is shown with solid lines. Wiring when external input is selected is shown with broken lines. Symbols ... D1, D2, D3, D4: Reverse supply polarity protection diode ZD1, ZD2: Surge absorption zener diode Tr1, Tr2 : PNP output transistor (Brown) +V (Black) Sensing output 1 50 mA max. + Load (Pink) External input 12 to 24 V DC +10 -15 % - (White) Sensing output 2 Load (Blue) 0 V Load Selection Guide PNP output type LS-500 Color code of cable type/quick-connection cable Brown (Note 1) Brown (Note 1) Black Load White Blue (Note 1) Gray Black Load + - Terminal layout of connector type 1 +V 2 Output 1 3 0V Terminal No. 4 Output 2 White 12 to 24 V DC +10 -15 % Pink + Load Blue (Note 1) Load Notes: 1) The quick-connection sub cable does not have brown lead wire and blue lead wire. The power is supplied from the connector of the main cable. 2) The quick-connection cable does not have gray or pink lead wires. MACHINE VISION SYSTEMS Non-voltage contact or PNP open-collector transistor * External input or High: +4 V to +V (sink current: 3 mA or less) Low : 0 to +0.6 V, or open * Light emission halts and teaching occurs when at High. Color code of cable type/quick-connection cable Pink ENERGY MANAGEMENT SOLUTIONS UV CURING SYSTEMS Users' circuit Wiring diagrams NPN output type HUMAN MACHINE INTERFACES FA COMPONENTS (Gray) Monitor output Internal circuit *1 MEASUREMENT SENSORS PLC 50 mA max. ZD2 D3 10 k (Black) Sensing output 1 WIRE-SAVING SYSTEMS LASER MARKERS Color code ZD1 D3 Tr3 Color code of quick-connection cable Sensor circuit Sensor circuit D1 SIMPLE WIRE-SAVING UNITS STATIC CONTROL DEVICES Cable type Terminal No. of connector type PARTICULAR USE SENSORS Load - 12 to 24 V DC +10 -15 % Load Gray Notes: 1) The quick-connection sub cable does not have brown lead wire and blue lead wire. The power is supplied from the connector of the main cable. 2) The quick-connection cable does not have gray or pink lead wires. * Connector for amplifier (CN-EP4) pin position 1 Terminal No. Connection cable 1 Purple 2 White 3 Shield 4 4 Shield 5 5 Black 6 6 Pink 2 3 Amplifier Built-in Amplifierseparated LS-400 209 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Digital Laser Sensor PRECAUTIONS FOR PROPER USE Refer to p.1552~ for general precautions and p.1593~ for information about laser beam. * This catalog is a guide to select a suitable product. Be sure to read the instruction manual attached to the product prior to its use. * Never use this product as a sensing device for personnel protection. * In case of using sensing devices for personnel protection, use products which meet regulations and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS LS-500 SERIES * These products are Class 1 laser in compliance with IEC, JIS standards and FDA* regulations. To reduce the risk of danger, do not look directly at the laser beam or view it through an optical system. * A label with instructions as found at the below is affixed to the product. Handle this sensor as per the instruction on the labels. SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS *This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). Safety standards for laser beam products * A laser beam can harm human being's eyes, skin, etc., because of its high energy density. IEC has classified laser products according to the degree of hazard and the stipulated safety requirements. LS-H is classified as Class 1 laser. Classification by IEC 60825-1 Class 1 Selection Guide Amplifierseparated LS-500 LS-400 2 (1) Fit the rear part of the mounting 1 section of the amplifier on a 35 mm 35 mm 1.378 in 1.378 in width DIN rail. width DIN rail (2) Press down the rear part of the mounting section of the unit on the 35 mm 1.378 in width DIN rail and fit the front part of the mounting section to the DIN rail. Description Lasers that are safe under reasonably foreseeable conditions of operation, including the use of optical instruments for intrabeam viewing. Safe use of laser products * For the purpose of preventing users from suffering injuries by laser products, IEC 60825-1 (Safety of laser products). Please check the standards before use. (Refer to p.1593~ for information about laser beam.) Part description (Amplifier) Sensing output 2 selection indicator (Yellow) Sensing output 1 selection indicator (Yellow) Laser emission indicator (Green) Sensing output 1 operation indicator (Orange) Sensing output 2 operation indicator (Orange) UP key * Teaching * Threshold value fine adjustment * Select setting items Note: B e careful. If the front part is lifted without pushing the amplifier forward, the hook on the rear portion of the mounting section is likely to break. (1) Insert the sensor head connector into the inlet until it clicks. (2) Fit the cover to the connector. Connector cover 12 mm 0.472 in MODE indicator: L/D (Yellow) MODE indicator: CUST (Yellow) MODE indicator: PRO (Yellow) 1 Attached toothed lock washer Mounting plate LS-H102 Metal plate MS-EXL2-2 (Accessory) 13 mm 0.512 in * In case mounting this product, use a metal plate MS-EXL2-2 (accessory). * The tightening torque should be 0.5 N*m or less with M3 screws. t 0.8 mm t 0.031 in 8.2 mm 0.323 in M3 screw (Purchase separately) * In case using the dedicated sensor head mounting bracket MS-EXL2-1 (optional) when mounting this product, the metal plate MS-EXL2-2 (accessory) is required depending on the mounting direction. Mount as the diagram below indicates. DOWN key * Teaching * Threshold value fine adjustment * Select setting items MODE key * Select Modes * Cancel during setting * Press down for 2 sec. or more: Switch the sensing output 1 / 2. M6 * The tightening torque should be 0.98 N*m or less. LS-H201, LS-H901 Digital display (Green / Red) 2 Sensor head side connector LS-H101 Metal plate Accessory for MS-EXL2-1 SET key * Teaching * Confirm setting contents 1 2 Sensor head Classification Amplifier Built-in Amplifier (1) Push the amplifier forward. (2) L ift up the front part of the amplifier to remove it. Cautions for laser beams SENSOR OPTIONS Mounting Sensor head mounting bracket MS-EXL2-1 (Optional) Metal plate MS-EXL2-2 (Accessory) M3 (length: 14 mm 0.551 in) screw with washer Accessory for MS-EXL2-1 14 mm Sensor head * The tightening torque 0.551 in Metal plate mounting bracket Accessory for should be 0.5 N*m or MS-LS-1 MS-LS-1 (Accessory) less. * When placing the sensor head horizontally or 19 mm 0.748 in M2 (length: 12 mm 0.472 in) screw vertically, the reflector with washer must also be positioned Accessory for MS-LS-1 horizontally or vertically as shown in Fig. 1 below.If the sensor head is placed horizontally or vertically but the reflector is tilted as shown in Fig. 2 below, the reflection amount will decrease, which may cause unstable detection. Digital Laser Sensor PRECAUTIONS FOR PROPER USE LS-500 SERIES 210 Refer to p.1552~ for general precautions and p.1593~ for information about laser beam. Wiring Fig. 1 Proper positioning When placing the sensor head horizontally or vertically, the reflector shall also be positioned horizontally or vertically. Fig. 2 Improper positioning When placing the reflector tilted even when the sensor head is positioned horizontally or vertically. * Make sure that the power supply is off while wiring. * Verify that the supply voltage variation is within the rating. * Take care that if a voltage exceeding the rated range is applied, or if an AC power supply is directly connected, the sensor may get burnt or damaged. * If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. * Make sure to use the optional quick-connection cable for the connection of the amplifier [connector type LS-501(P)]. Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. However, in order to reduce noise, make the wiring as short as possible. Set the supply voltage after considering the voltage drop caused by the cable's resistance. When adding units, wiring length must not exceed 50 m 164.042 ft (for 5 to 8 amplifiers) or 20 m 65.617 ft (for 9 to 16 amplifiers). Others * Do not use during the initial transient time (0.5 sec. approx.) after the power supply is switched on. * Because the sensitivity is higher in U-LG and HYPER modes than in other modes, it can be more easily affected by extraneous noise. Check the operating environment before use. DIMENSIONS (Unit mm in) LS-501 The CAD data can be downloaded from our website. LS-501P Amplifier 8.2 0.323 Sensing output 2 selection indicator (Yellow) Sensing output 1 selection indicator (Yellow) 62.5 2.461 2 0.079 4.75 0.187 Laser emission indicator (Green) Sensing output 1 operation indicator (Orange) Sensing output 2 operation indicator (Orange) 9.95 0.392 Digital display (Red, Green) LS-501-C2 LS-501P-C2 8.2 0.323 Setting key Sensing output 2 selection indicator (Yellow) Sensing output 1 selection indicator (Yellow) MODE key Laser emission indicator (Green) Sensing output 1 operation indicator (Orange) Sensing output 2 operation indicator (Orange) Amplifier 62.5 2.461 2 0.079 4.75 0.187 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES 9.95 0.392 Setting key ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS Digital display (Red, Green) MODE key MACHINE VISION SYSTEMS UV CURING SYSTEMS 10 0.394 47.2 1.858 Communication window 47.8 1.882 22.7 0.894 7 0.276 32 1.260 28 1.102 19.2 20.8 0.756 0.819 2.7 0.106 3 0.118 6.5 0.256 24 0.945 Suitable for 35 mm 1.378 in width DIN rail 36.5 1.437 75 2.953 (98.3 3.870) CN-74-C1 CN-74-C2 CN-74-C5 CN-74-C1 10.5 0.413 3.95 0.156 2.7 0.106 3 0.118 6.5 0.256 50 1.969 1,000 39.370 CN-74-C2 2,000 78.740 CN-74-C5 5,000 196.850 o3.3 o0.130 cable 14 0.551 2.9 0.114 2.54 0.100 10 0.394 6 0.236 2.54 0.100 0.2 7 0.008 0.276 10 0.394 13.6 0.535 2 3. 13 R2 0.9 R 9.2 0.362 24 0.945 36.5 1.437 75 2.953 (98.3 3.870) 2.8 0.110 o4 o0.157 in 6-core cable, 2 m 6.562 ft long Sub cable (Optional) * Length (L) Model No. Length (mm in) CN-72-C1 1,000 39.370 CN-72-C2 2,000 78.740 CN-72-C5 5,000 196.850 L 50 1.969 o3.3 o0.130 cable 3 0.118 10 0.394 6 0.236 14 0.551 2.54 0.100 2.9 0.114 12 10.5 0.472 0.413 3 0.118 7.2 0.283 2.65 0.104 2.54 0.100 Amplifier Built-in Amplifierseparated LS-500 LS-400 CN-72-C1 CN-72-C2 CN-72-C5 12 0.472 10.5 0.413 2.65 0.104 22.7 0.894 7 0.276 Selection Guide Suitable for 35 mm 1.378 in width DIN rail L Length (mm in) 47.2 1.858 Communication window 47.8 1.882 32 1.260 28 19.2 1.102 0.756 20.8 0.819 Main cable (Optional) * Length (L) Model No. 10 0.394 2 3. 13 R2 0.9 R 0.2 7 0.008 0.276 10 0.394 13.6 0.535 3 0.118 7.2 0.283 211 Digital Laser Sensor DIMENSIONS (Unit mm in) FIBER SENSORS LASER SENSORS LS-500 SERIES The CAD data can be downloaded from our website. LS-H101 Sensor head LS-H102 Sensor head PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Beam axis AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS 30 1.181 12 0.472 2.8 0.110 2.8 0.110 Operation indicator (Orange) (Note) 12 0.472 13 0.512 6 0.236 M6 x 0.75 0.030 PRESSURE / FLOW SENSORS 8.2 0.323 6.4 0.252 2.5 0.098 Operation indicator (Orange) (Note) 9.3 0.366 18.6 0.732 23.4 0.921 2-o3.2 o0.126 mouting holes Beam axis 4.1 0.161 4.6 0.181 INDUCTIVE PROXIMITY SENSORS Note: Not incorporated on the emitter. PARTICULAR USE SENSORS SENSOR OPTIONS LS-H201 Note: Not incorporated on the emitter. LS-H901 Sensor head MS-DIN-E End plate (Optional) SIMPLE WIRE-SAVING UNITS 8 0.315 WIRE-SAVING SYSTEMS MEASUREMENT SENSORS 3.15 0.124 0.8 0.031 STATIC CONTROL DEVICES 6.9 0.272 LASER MARKERS 9 5 0.354 0.197 18 0.709 2 14 6.4 0.079 2 1 0.252 0.079 0.039 0.551 Operation indicator (Orange) 2-o2.2 o0.087 M3 (length 18 mm 0.709 in) pan head screw 2.75 0.108 3 0.118 15 0.591 60 2.362 3 0.118 5.6 M3 square nut 0.220 24.7 0.972 23 0.906 19 0.748 PLC 4 0.157 Suitable for 35 mm 1.378 in width DIN rail 32 1.260 1.6 0.063 Material: Polycarbonate HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS RF-330 Reflector (Accessory for LS-H901) FA COMPONENTS 30 1.181 24 0.945 MACHINE VISION SYSTEMS 45 1.772 37 1.457 23 0.906 UV CURING SYSTEMS Selection Guide Amplifier Built-in 2-o3.2 o0.126 mounting holes RF-310 Reflector (Optional) 12 0.472 8 0.315 7 0.276 5.5 0.217 4.2 0.165 24 0.945 17.2 7 0.276 0.677 32 1.260 4 0.157 2-o3.2 o0.126 3.2 mounting holes 0.126 13.6 0.535 Material: Acrylic (Reflector) ABS (Base) Material: Acrylic (Reflector) ABS (Base) Amplifierseparated RF-33 RF-31 LS-500 B LS-400 Reflective tape (Optional) Amplifier mounting bracket (Optional) 21.6 0.850 16 0.630 0.4 0.016 Model No. RF-33 RF-31 10 8.5 0.335 5.2 0.205 Adhesive tape A MS-DIN-2 A B 25.2 0.992 27.8 1.094 9.2 0.362 9.2 0.362 5 0.394 0.197 3.2 0.126 0.4 0.016 o1.8 o0.071 7.5 0.295 4.2 0.165 2-o3.2 o0.126 holes 2 0.079 35 1.378 5.2 3.2 0.205 0.126 2 0.079 t1 t 0.039 27 1.063 Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) Digital Laser Sensor DIMENSIONS (Unit mm in) MS-LS-1 MS-EXL2-1 Sensor head mounting bracket (Accessory for LS-H201, LS-H901) 11 11 0.433 0.433 4 0.157 FIBER SENSORS Sensor head mounting bracket for LS-H102 (Optional) LASER SENSORS Assembly dimensions 8.7 6 0.236 14.5 0.343 0.571 2-M2 x 0.4 0.016 5 0.197 1 4 0.157 R1.5 R0.059 26 1.024 t 1.2 t 0.047 2.4 19 0.0 94 0.748 19 0.748 2.4 94 29.5 0.0 1.161 3 2 1.2 0.047 2.5 3 0.098 11.6 0.457 0.118 3-M3 x 0.5 0.020 7.5 12.5 0.492 0.295 3 0.118 t 1.5 t 0.059 13 0.512 3.2 24.1 0.126 0.949 7.5 0.295 12.5 0.492 16 0.630 3.2 0.126 2.5 3.5 0.098 0.138 Beamreceiving part 2.5 0.098 10 3.05 0.120 43 1.693 3.05 0.120 3.1 0.122 26.5 1.043 t 1.2 t 0.047 3.4 MICRO PHOTOELECTRIC SENSORS 12 0.472 2 0.079 8 0.315 16 0.630 14 13 0.512 20.2 3.4 16 0.630 14 R13 R0.512 R23.6 R0.929 R23.6 t 1.2 R0.929 t 0.047 3.2 0.126 3.2 0.126 23.6 0.929 2-o2.2 o0.087 14 0.551 3.5 0.138 8 0.315 2 0.079 3.5 0.138 2.5 0.098 3.5 0.138 PHOTOELECTRIC SENSORS Mounting drawing with the receiver of LS-H102 2 3.5 0.138 212 The CAD data can be downloaded from our website. Foot angled mounting bracket 1 LS-500 SERIES R13 R0.512 INDUCTIVE PROXIMITY SENSORS 13 0.512 PARTICULAR USE SENSORS Material: Stainless steel (SUS304) Two M2 (length 12 mm 0.472 in) screws with washers [stainless steel (SUS)] are attached. Two M3 (length 14 mm 0.551 in) screws with washers [stainless steel (SUS)] are attached. MS-EXL2-5 Mounting plate (Accessory for LS-H102) 2.8 0.110 9 0.354 1 0.039 2-o3.05 o0.120 2.8 0.110 2.6 0.102 1.5 0.059 1 14 3.4 0.134 16.4 13 24 0.646 0.512 0.945 Beamemitting part 3 0.118 Note: Without using the mounting plate, beam misalignment may occur. Material: Stainless steel (SUS304) Note: Screws are not attached. Purchase separately. 8.8 0.346 18.5 0.728 4.5 0.177 2.5 0.098 16 0.630 13 0.512 2 1.5 0.059 4 0.157 11.2 0.441 1.5 0.059 3.05 0.120 31.5 1.240 14 0.551 o8.5 o0.335 2-hexagon nut seats 8.4 0.331 2-o3.2 o0.126 3 mounting holes 13 0.512 25.5 1.004 3 0.118 3 9.5 0.374 12 0.472 5.5 0.217 5.5 0.217 t 1.5 t 0.059 o3.3 o0.130 thru-hole 15 0.591 6 0.236 14 0.551 1.5 0.059 3-M3 x 0.5 0.020 3.8 0.150 15.5 0.610 19.5 0.768 4 0.157 30 1.181 16.5 0.650 3 0.118 3.05 0.120 Material: Die-cast zinc alloy Two M3 (length 14 mm 0.551 in) screws with washers [stainless steel (SUS)], one M3 (length 10 mm 0.394 in) hexagon socket-head bolt [stainless steel (SUS)], and one M3 hexagon nut [stainless steel (SUS)] are attached. PLC HUMAN MACHINE INTERFACES ENERGY FA COMPONENTS 10 3 3.2 0.118 0.126 3.05 0.120 MACHINE VISION SYSTEMS UV CURING SYSTEMS Material: Stainless steel (SUS304) 13 0.512 2.5 0.098 10 2.5 0.098 6.7 0.264 8.8 0.346 16 0.630 Amplifierseparated 2.3 0.091 3.8 0.150 5.1 0.201 3 0.118 15 (Note) 13 0.591 0.512 31.5 1.240 6.5 0.256 Beamreceiving 2.5 0.098 part o8.5 o0.335 30 1.181 15 12 0.591 0.472 6 0.236 14 0.551 Selection Guide Amplifier Built-in Mounting drawing with the receiver of LS-H102 2-o3.2 o0.126 mounting holes 3.45 0.136 STATIC CONTROL DEVICES MANAGEMENT 2.5 SOLUTIONS 0.098 2.5 0.098 t 1.5 t 0.059 Assembly dimensions Universal sensor mounting bracket o8.5 o0.335 3-M3 x 0.5 0.020 Sensor head mounting bracket for LS-H102 (Optional) 1 MEASUREMENT SENSORS Two M3 (length 14 mm 0.551 in) screws with washers [stainless steel (SUS)] are attached. MS-EXL2-4 25.5 28.5 1.004 1.122 14.2 0.559 8 0.315 3.05 0.120 1 0.039 3.05 0.120 4.1 0.161 R13 R0.512 2 2.6 0.102 3.5 0.138 t 0.8 t 0.031 t 1.2 t 0.047 4.9 0.193 18.8 13 0.740 0.512 SIMPLE WIRE-SAVING UNITS LASER MARKERS Mounting drawing with the emitter of LS-H102 10.6 0.417 Sensor head mounting bracket for LS-H102 (Optional) Back angled mounting bracket Assembly dimensions SENSOR OPTIONS WIRE-SAVING SYSTEMS Material: Stainless steel (SUS304) MS-EXL2-2 SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS 43 1.693 26.5 t 1.2 1.043 t 0.047 33 1.299 AREA SENSORS 9.5 0.374 19.5 0.768 Note: This is the adjustable range of the movable part. LS-500 LS-400