Selection
Guide
Amplier
Built-in
Amplier-
separated
LS-500
LS-400
Timer functions
Amplifiers
Connector type
LS-501
LS-501P
Cable type
LS-501-C2
LS-501P-C2
Type
NPN output
PNP output
Item
Power consumption
Normal operation: 1,200 mW or less (Current consumption 50 mA or less at 24 V supply voltage,Cable type: excluding monitor current output)
ECO mode: 980 mW or less (Current consumption 40 mA or less at 24 V supply voltage,Cable type: excluding monitor current output)
Supply voltage
Sensing outputs
(Sensing output 1, 2)
(Note 4)
Selectable either Light-ON or Dark-ON
Incorporated
Normal mode, differential mode, hysteresis mode, window comparator mode, selectable
H-SP: 60 μs or less, FAST: 150 μs or less, STD: 250 μs or less, LONG: 500 μs or less, U-LG: 5 ms or less, HYPR: 24 ms or less , selectable
Timer period
<NPN output type>
NPN open-collector transistor
• Maximum sink current: 50 mA (Note 2)
•
Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 2 V or less (at max. sink current)
<PNP output type>
PNP open-collector transistor
• Maximum source current: 50 mA (Note 2)
•
Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 2 V or less (at max. source current)
Output current: Approx. 4 to 20 mA (H-SP, FAST, STD: at 0 to 4,000 indication)
Response time: 2 ms or less
Zero point: 4 mA ± 1 % F.S.
Span: 16 mA ± 5 % F.S.
Linearity: ± 3 % F.S.
Load resistance: 0 to 250 Ω
Response time
Laser emission halt / teaching (full-auto teaching, limit teaching, 2 point teaching) / logic operation setting / copy lock /
display adjustment / data bank load / data bank save, selectable
External input function
Sensing
output
setting
Orange LED (lights up when sensing output 1 or sensing output 2 is ON)
Green LED (lights up during laser emission)
Yellow LED (lights up when output is selected)
8-digit 7-segment digital display (4-digit green LED + 4-digit red LED), MODE indicator (Yellow LED): L/D, CUST, PRO
H-SP / FAST / STD: 0 to 4,000, LONG / U-LG / HYPR: 0 to 9,999
2-level teaching / limit teaching / full auto teaching / manual adjustment
Incorporated (Note 3)
– 10 to +55°C +14 to +131 °F (If 4 to 7 units are mounted close together, – 10 to +50°C +14 to +122 °F; if 8 to 16 units (cable type: 8 to 12 units)
are mounted close together, – 10 to +45 °C +14 to +113°F) (No dew condensation or icing allowed), Storage: – 20 to +70 °C –4 to +158 °F
Interference prevention function
Ambient temperature
<NPN output type>
NPN non-contact input
• Signal condition
High: +8 V to +V DC or open,
Low: 0 to +2 V DC (source current 0.5 mA or less)
• Input impedance: 10 kΩ approx.
Normal mode, differential mode, hysteresis mode,
self-diagnosis output mode, selectable
Normal mode, differential mode, hysteresis mode, self-diagnosis
output mode, answer-back output mode, selectable
35 to 85 % RH, Storage: 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in (max. 10 G) double amplitude in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Enclosure: Polycarbonate, Cover: Polycarbonate, Switch: Polyacetal
IP40 (IEC)
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
FX-MB1 (Amplifier protective seal): 1 set
Between sensing output 1 and calculation target: Disabled / AND / OR / XOR, selectable
Calculation target: Sensing output 2 / adjacent upstream amplifier (sensing output 1) / external input, selectable
Net weight: 15 g approx., Gross weight: 55 g approx.
0.2 mm2 6-core cabtyre cable, 2 m 6.562 ft long
Net weight: 75 g approx., Gross weight: 110 g approx.
Timer range “ms”: 0.5 ms approx., 1 to 9,999 ms approx., in approx. 1 ms intervals
Timer range “sec”: 0.5 sec. approx., 1 to 32 sec. approx., in approx. 1 sec. intervals
Timer range “1/10 ms”: 0.05 ms approx., 0.1 to 999.9 ms approx., in approx. 0.1 ms intervals, Set separately for each output.
<PNP output type>
PNP non-contact input
• Signal condition
High: +4 V to +V DC (sink current 3.0 mA or less),
Low: 0 to +0.6 V DC or open
• Input impedance: 10 kΩ approx.
External input (Note 4)
Environmental
resistance
Model No.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) 25 mA if 5 or more amplifier are connected in cascade (excluding cable extension).
3) Number of units that can be mounted close together: 0 for H-SP; 2 for FAST; 4 for STD, LONG, U-LG, or HYPR
4) Select either sensing output 2 or external input as the connector type.
12 to 24 V DC % Ripple P-P 10 % or less
+10
–15
CE marking directive compliance
EMC Directive, RoHS Directive
Output operation
Short-circuit protection
Sensing output 1
Sensing output 2
(Note 4)
Sensing output operation indicator
Laser emission indicator
Output select indicator
Digital display
Incident light indication range
Sensitivity setting
Logical operation
Ambient humidity
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
Material
Protection
Cable
Cable extension
Weight
Accessory
Monitor current output
<Sensing output 1>
OFF-delay timer, ON-delay timer, One-shot timer, ON/OFF-delay timer, ON-delay / One-shot timer,
switchable either effective or ineffective, with variable timer period
<Sensing output 2>
OFF-delay timer, ON-delay timer, One-shot timer,
switchable either effective or ineffective, with variable timer period
SPECIFICATIONS