Additional Resources: Product Page | 3D Model | PCB Footprint date page 10/08/2019 1 of 4 SERIES: MD-SV DESCRIPTION: MINI DIN CONNECTOR FEATURES * PCB mount * vertical mount * 3~8 pins PART NUMBER KEY MD - XX SV Base Number Pin Options 30 = 3 pins 40 = 4 pins 50 = 5 pins 60 = 6 pins 70 = 7 pins 80 = 8 pins SPECIFICATIONS parameter conditions/description min rated input voltage typ max 12 units Vdc rated input current 2 A contact resistance 30 m 250 Vac 45 N 30 N insulation resistance at 250 Vdc voltage withstand for 1 minute 50 M insertion force withdrawal force 9 operating temperature -20 life 85 1,000 flammability rating UL94V-0 RoHS yes cuidevices.com C cycles Additional Resources: Product Page | 3D Model | PCB Footprint CUI Devices SERIES: MD-SV DESCRIPTION: MINI DIN CONNECTOR date 10/08/2019 page 2 of 4 MECHANICAL DRAWINGS (MD-30SV, MD-40SV, MD-50SV) units: mm tolerance: X.X 0.2 mm X.XX 0.10 mm X.XXX 0.050 mm X.XXX 0.030 mm MD-30SV PLATING/COLOR housing PBT (UL94V-0) black contacts phosphor bronze tin shell brass nickel MD-40SV MATERIAL MD-50SV Recommended PCB Layout Bottom View Recommended PCB Layout Bottom View cuidevices.com Recommended PCB Layout Bottom View Additional Resources: Product Page | 3D Model CUI Devices SERIES: MD-SV DESCRIPTION: MINI DIN CONNECTOR | PCB Footprint date 10/08/2019 page 3 of 4 MECHANICAL DRAWINGS (MD-60SV, MD-70SV, MD-80SV) MD-60SV Recommended PCB Layout Bottom View MD-70SV Recommended PCB Layout Bottom View cuidevices.com MD-80SV Recommended PCB Layout Bottom View Additional Resources: Product Page | 3D Model | PCB Footprint CUI Devices SERIES: MD-SV DESCRIPTION: MINI DIN CONNECTOR date 10/08/2019 page 4 of 4 REVISION HISTORY rev. description date 1.0 initial release 02/23/2006 1.01 new template applied 03/07/2012 1.02 updated datasheet 08/25/2017 updated housing, added 7 pin version, brand update 10/08/2019 1.03 The revision history provided is for informational purposes only and is believed to be accurate. CUI Devices offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI Devices reserves the right to make changes to the product at any time without notice. Information provided by CUI Devices is believed to be accurate and reliable. However, no responsibility is assumed by CUI Devices for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI Devices products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. cuidevices.com