Model SWG150 Series
Parameter Model
SWG150-05 SWG150-12 SWG150-24
Input Conditions
Rated Input Voltage 100 to 240 VAC (140 to 340 VDC)
Allowable Input Voltage 85 to 264 VAC (120 to 370 VDC)
Input Current (typ) 2.0 A (100 VAC) / 1.0 A (200 VAC)
Rated Frequency 50 / 60 Hz
Allowable Frequency Range 47 to 63 Hz
Efficiency (typ) AC 100 V 83% 83% 85%
AC 200 V 86% 86% 88%
Power Factor (typ) 0.99 A (100 VAC) / 0.93 A (200 VAC)
Inrush Current (typ)1,2 20 A (VIN = 100 V) / 40 A (VIN = 200 V) IO = 100% at Cold Start
Leakage Current (max) 0.40 mA (VIN = 100 V) / 0.75 mA (VIN = 240 V) 60 Hz IO = 100% per measuring method of
IEC60950-1 and PSE
Output Conditions
Rated Output Voltage 5 V 12 V 24 V
Rated Output Current 30 A 13 A 6.5 A
Static Input Variation 20 mV max 48 mV max 96 mV max
Static Load Variation 40 mV max 100 mV max 150 mV max
Ripple30º to 50º C 80 mVp-pmax 120 mVp-pmax 120 mVp-pmax
-10º to 0º C 140 mVp-pmax 160 mVp-pmax 160 mVp-pmax
Ripple Noise30º to 50º C 120 mVp-pmax 150 mVp-pmax 150 mVp-pmax
-10º to 0º C 160 mVp-pmax 180 mVp-pmax 180 mVp-pmax
Ambient Temperature
Variation
0º to 50º C 50 mV max 120 mV max 240 mV max
-10º to 0º C 60 mV max 150 mV max 290 mV max
Time Course Drift420 mV max 48 mV max 96 mV max
Startup Time1350 ms typ (VIN = 100 V IO = 100%)
Output Holding Time120 ms typ (VIN = 100 V IO = 100%)
Voltage Variation Range94.00 to 5.50 V 10.0 to 13.2 V 19.2 to 27.0 V
Voltage Set Point 5.00 to 5.15 V 12.00 to 12.48 V 24.00 to 24.96 V
Additional Functions
Overcurrent Protection Detection above 105% of rated current (automatic recovery)
Overvoltage Protection55.75 to 7.00 V 15.0 to 18.0 V 30.0 to 37.0 V
Operations Display LED Display: Green
Environmental
Conditions
Operating Temperature Range –10°C to 71°C (with derating)
Storage Temperature Range –20°C to 75°C
Operating Humidity Range 20% to 90% RH (no condensation)
Storage Humidity Range 20% to 90% RH (no condensation)
Cooling Requirements Natural air cooling
Vibration
Resistance
Vibration Frequency 10 to 55 Hz
Sweep Time 3 minutes
Acceleration 19.6 m / s2 (2 G)
Vibration Direction x, y, z
Vibration Time One hour in each of three directions
Shock Resistance 196.1m/s2 (20G) 11 ms One each of three directions x, y, z
Installation Conditions Derating may be required due to mounting orientation