1
SANKEN ELECTRIC CO., LTD.
No.PAN40006-001-E00
All information subject to
change without notice
October 2014
Continued on the next page…
Model SWG150 Series
Parameter Model
SWG150-05 SWG150-12 SWG150-24
Input Conditions
Rated Input Voltage 100 to 240 VAC (140 to 340 VDC)
Allowable Input Voltage 85 to 264 VAC (120 to 370 VDC)
Input Current (typ) 2.0 A (100 VAC) / 1.0 A (200 VAC)
Rated Frequency 50 / 60 Hz
Allowable Frequency Range 47 to 63 Hz
Efficiency (typ) AC 100 V 83% 83% 85%
AC 200 V 86% 86% 88%
Power Factor (typ) 0.99 A (100 VAC) / 0.93 A (200 VAC)
Inrush Current (typ)1,2 20 A (VIN = 100 V) / 40 A (VIN = 200 V) IO = 100% at Cold Start
Leakage Current (max) 0.40 mA (VIN = 100 V) / 0.75 mA (VIN = 240 V) 60 Hz IO = 100% per measuring method of
IEC60950-1 and PSE
Output Conditions
Rated Output Voltage 5 V 12 V 24 V
Rated Output Current 30 A 13 A 6.5 A
Static Input Variation 20 mV max 48 mV max 96 mV max
Static Load Variation 40 mV max 100 mV max 150 mV max
Ripple30º to 50º C 80 mVp-pmax 120 mVp-pmax 120 mVp-pmax
-10º to 0º C 140 mVp-pmax 160 mVp-pmax 160 mVp-pmax
Ripple Noise30º to 50º C 120 mVp-pmax 150 mVp-pmax 150 mVp-pmax
-10º to 0º C 160 mVp-pmax 180 mVp-pmax 180 mVp-pmax
Ambient Temperature
Variation
0º to 50º C 50 mV max 120 mV max 240 mV max
-10º to 0º C 60 mV max 150 mV max 290 mV max
Time Course Drift420 mV max 48 mV max 96 mV max
Startup Time1350 ms typ (VIN = 100 V IO = 100%)
Output Holding Time120 ms typ (VIN = 100 V IO = 100%)
Voltage Variation Range94.00 to 5.50 V 10.0 to 13.2 V 19.2 to 27.0 V
Voltage Set Point 5.00 to 5.15 V 12.00 to 12.48 V 24.00 to 24.96 V
Additional Functions
Overcurrent Protection Detection above 105% of rated current (automatic recovery)
Overvoltage Protection55.75 to 7.00 V 15.0 to 18.0 V 30.0 to 37.0 V
Operations Display LED Display: Green
Environmental
Conditions
Operating Temperature Range –10°C to 71°C (with derating)
Storage Temperature Range –20°C to 75°C
Operating Humidity Range 20% to 90% RH (no condensation)
Storage Humidity Range 20% to 90% RH (no condensation)
Cooling Requirements Natural air cooling
Vibration
Resistance
Vibration Frequency 10 to 55 Hz
Sweep Time 3 minutes
Acceleration 19.6 m / s2 (2 G)
Vibration Direction x, y, z
Vibration Time One hour in each of three directions
Shock Resistance 196.1m/s2 (20G) 11 ms One each of three directions x, y, z
Installation Conditions Derating may be required due to mounting orientation
2
SANKEN ELECTRIC CO., LTD.
No.PAN40006-001-E00
All information subject to
change without notice
October 2014
Continued from the previous page…
Model SWG150 Series
Parameter Model
SWG150-05 SWG150-12 SWG150-24
Insulation7
Insulation
Withstand
Voltage
Input-Output 3000 VAC one minute (leakage current 10 mA or less)
Input-FG 2000 VAC one minute (leakage current 10 mA or less)
Output-FG 500 VAC one minute (leakage current 100 mA or less)
Insulation
Resistance
Input-Output
50 MΩ (measured with 500 VDC Megger)Input-FG
Output-FG
Others
Input/Output Type Terminal Stand
Dimensions 34 mm (W) X 93 mm (H) X 168 mm (D) (without terminal stand)
Weight 560g maximum (without cover)
Safety Standards UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, PSE
EMI Safety Designed to meet FCC Class B, VCCI Class B, CISPR22 Class B, EN55011 Class B,
EN55022 Class B
Harmonic Current Designed to meet IEC61000-3-2
Electromagnetic Susceptibility
Designed to meet EN61000-4-2 (for electrostatic discharge)
Designed to meet EN61000-4-3 (for radiated, radio-frequency, electromagnetic field)
Designed to meet EN61000-4-4 (for transient burst)
Designed to meet EN61000-4-5 (for lightning surge)
Designed to meet EN61000-4-6 (for conductive radio frequency electromagnetic field)
Designed to meet EN61000-4-8 (for power supply frequency electromagnetic field
immunity)
Designed to meet EN61000-4-11 (for voltage dip/variation)
Environmental Response Designed to meet RoHS directive
Options
Remote On/Off Yes
Connector JST (escept 5 V output)
Cover8Yes
1. Specified under rated input/output conditions at an ambient temperature of 25°C.
2. More current above noted values may flow at restart (ambient temperature of 25°C).
3. Ripple noise is measured with a 20 MHz oscilloscope using a 1:1 probe.
4. Time-course drift is measured between 30 minutes to 8 hours after applying input voltage at rated input/output at an ambient temperature 25ºC.
5. Reset is performed by reapplying input voltage.
6. Output derating may be required.
7. Insulation conditions are specified at normal temperature and humidity.
8. Derating may be required for the power supply with cover.
9. In the case where output voltage is variable, set a voltage such that Output Voltage Variation, Rated Output Current, and Rated Output Power are
not exceeded.