FES2DB 2.0 Amp. Surface Mount Glass Passivated Ultrafast Recovery Rectifier Current 2.0 A Voltage 200 V R DO-214AA (SMB) FEATURES Low profile package Ideal for automated placement Ultrafast recovery time for high efficiency Low power losses Low forward voltage drop High forward surge current capability Solder dip 260C, 10s AEC-Q101 qualified Component in accordance to RoHS 2011/65/EU and WEEE 2002/96/EC Meets MSL level 1, per J-STD-020, LF maximum peak of 260 C MECHANICAL DATA Case: DO-214AA (SMB). Epoxy meets UL 94V-0 flammability rating. Polarity: Color band denotes cathode end. Terminals : Matte tin plated leads, solderable per MIL-STD-750 Method 2026, J-STD-002 and JESD22-B102. Consumer grade, meets JESD 201 class 1A whisker test. HE3 suffix for high reliability grade, meets JESD 201 class 2 whisker test. TYPICAL APPLICATIONS Used in high frequency rectification and freewheeling application in switching mode converters and inverters for consumer, computer, automotive and telecommunication. Maximun Ratings and Electrical Characteristics at 25C FES2DB Marking Code VA VRRM Maximum Recurrent Peak Reverse Voltage (V) 200 VRMS Maximum RMS Voltage (V) 140 VDC Maximum DC Blocking Voltage (V) 200 IF(AV) Forward current at TC = 110 C 2.0 A IFSM 8.3 ms. peak forward surge current 50 A VF Maximum Instantaneous Forward Voltage at 2.0A at 0.7A Maximum DC Reverse Current Tj = 25 C at Rated DC Blocking Voltage Tj = 100 C 0.90 V 0.80 V 5 A 350 A Trr Maximum Reverse Recovery Time (0.5/1/0.25A) 25 ns Cj Typical Junction Capacitance (1MHz; -4V) 55 pF Rth (j-c) Rth (j-a) Maximum Thermal Resistance (5x5 mm2 x 130 Copper Area) Tj - Tstg Operating Junction and Storage Temperature Range IR (Jedec Method) www.fagorelectronica.com Document Name: fes2db 20 C/W 60 C/W -65 to + 150 C Version: Feb-13 Page Number: 1/4 FES2DB 2.0 Amp. Surface Mount Glass Passivated Ultrafast Recovery Rectifier Ordering information PACKAGE CODE DELIVERY MODE BASE QUANTITY UNIT WEIGHT (g) FES2DB TRTB TRTB 13" diameter tape and reel 3,200 0.082 FES2DB HE3 TRTB TRTB 13" diameter tape and reel 3,200 0.082 Package Outline Dimensions: (mm) 1.050.2 5.10.3 DO-214AA (SMB) +0.1 0.2 -0.05 2.20.3 0.150.1 PREFERRED P/N 1.250.25 1.250.25 Year code Marking code www.fagorelectronica.com Document Name: fes2db Mounting Pad Layout 2.4 3.50.3 MC WW Y 2 -0.1 +0.2 Week code 2 4.2 Version: Feb-13 Page Number: 2/4 FES2DB 2.0 Amp. Surface Mount Glass Passivated Ultrafast Recovery Rectifier TYPICAL FORWARD CHARACTERISTIC 10 I F , instantaneous forward current (A) I F(AV) , average forward rectified current (A) FORWARD CURRENT DERATING CURVE 3 2 2 5x5mm x 130 m Thick Copper Land Areas 1 0 0 25 50 2 1 0.2 0.1 0.01 0.6 75 100 125 150 175 Lead temperature (C) MAXIMUM NON REPETITIVE PEAK FORWARD SURGE CURRENT 1 1.2 1.4 1.6 TYPICAL REVERSE CHARACTERISTIC 10 50 T j = 125 C IR, Reverse current (mA) I FSM , peak forward surge current (A) 0.8 VF, instantaneous forward voltage (V) 40 30 20 1 T j = 75 C 0.1 T j = 25 C 10 0 0.01 1 2 4 6 10 20 40 100 Cj , junction capacitance (pF) Number of cycles at 60 Hz 60 80 100 120 Percent of rated peak reverse voltage TYPICAL JUNCTION CAPACITANCE Tj = 25 C f = 1 MHz 100 40 20 10 www.fagorelectronica.com Document Name: fes2db 20 40 0.1 0.4 1.0 4 10 VR , reverse voltage 40 100 Version: Feb-13 Page Number: 3/4 FES2DB 2.0 Amp. Surface Mount Glass Passivated Ultrafast Recovery Rectifier Disclaimer All product, product specifications and data are subject to change without notice to improve reliability, function or design or otherwise. Fagor Electronica, S.Coop., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, "Fagor"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Fagor makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Fagor disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Fagor's knowledge of typical requirements that are often placed on Fagor products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer's responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer's technical experts. Product specifications do not expand or otherwise modify Fagor's terms and conditions of purchase, including but nos limited to the warranty expressed therein. Except as expressly indicated in writing. Fagor products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Fagor product could result in personal injury or death. Customers using or selling Fagor products not expressly indicated for use in such applications do so at their own risk and agree to fully indemnify and hold Fagor and its distributors harmless from and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale, including attomeys fees, even if such claim alleges that Fagor or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Fagor personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Fagor, Product names and markings noted herein may be trademarks of their respective owners. www.fagorelectronica.com Document Name: fes2db Version: Feb-13 Page Number: 4/4