Thordarson International Transformers, Isolation Transformers, Power Supplies and Cords International Step-Down Autoformers Foreign Power Supplies and Power Cords The UL/Classified is for the EU Series The UL/C insignia is for the NA Series c c c c Primary: 230 VAC 50/60 Hz Secondary: 115 VAC Circuit Breaker Output Termination: 100 VA-1500 VA N 4" Line Cord with NEMA 5-15R; 2000 VA N 4" Line Cord with NEMA 5-20R (Canadian Style); 2500 VA N Two 15 A Receptacles, Case Mounted c United Kingdom and Australian Versions Also Available c These Units Do Not Change Frequency Dimensions VA Size 100 200 350 500 750 1000 1500 2000 2500 Mounting European (Schuko) H W D MW MD Wt. (Lbs.) 37/8 37/8 37/8 45/8 45/8 55/16 57/8 57/8 65/16 3 3/16 3 3/16 3 1/12 3 13/16 3 13/16 4 7/16 4 5/16 4 5/16 5 5/16 4 3/16 4 5/16 5 3/8 5 1/2 6 1/2 6 3/4 7 7 3/4 9 1/8 21/2 21/2 21/2 3 3 31/2 37/16 37/16 41/4 3 31/8 315/16 47/16 57/16 51/4 65/8 63/8 75/8 4.3 4.7 6.6 10.0 13.0 16.4 16.7 21.3 38.0 North America Stock No. Mfr.Os Type EACH 704-0001 704-0002 704-0003 704-0004 704-0005 704-0006 704-0007 704-0130 704-0132 TSD-100-EU TSD-200-EU TSD-350-EU TSD-500-EU TSD-750-EU TSD-1000-EU TSD-1500-EU TSD-2000-EU TSD-2500-EU Mfr.Os Type EACH 1-9 Stock No. 67.35 71.67 87.98 99.54 117.50 141.03 241.93 409.29 535.31 704-0023 704-0024 704-0025 704-0026 704-0027 704-0028 704-0029 704-0030 704-0031 TSD-100-NA TSD-200-NA TSD-350-NA TSD-500-NA TSD-750-NA TSD-1000-NA TSD-1500-NA TSD-2000-NA TSD-2500-NA 64.60 68.37 85.20 102.70 120.39 185.45 239.33 406.67 519.30 1-9 International Step-Up Autoformers The UL/C insignia is for the NA Series c Primary 115 V, 50/60 Hz c Secondary 230 V c Circuit Breaker 100 350 500 750 1000 1500 2000 2500 IEC Input Port For Foreign Cords Operates On 50 Hz and 60 Hz Input With Safety* Isolated Output Receptacle Convenient On-Off Switch Circuit Breaker Voltage Selector Power For Photographic/TV Crews Abroad Power For International Trade Shows Conversion for U.S. Appliances in Foreign Use *Note: Unit does not change frequency. Use only for equipment that can be operated on 50 Hz only, 60 Hz only or 50/60 Hz. Universal Voltage Converters N Converts 100/120/220/240 V to isolated 120 V with optional foreign power IEC input cords to suit your use location. Receptacle: 75-100, 250 N 1; 75-500, 1000 N 2. Foreign Power Supplies Stock No. 704-7510 704-7525 704-0500 704-1000 Mfr.Os Type VA Output Maximum Dimensions (In.) W L 100 250 500 1000 5 7/8 5 7/8 7 3/8 7 3/8 75-100 75-250 75-500* 75-1000 H Wt. (Lbs.) EACH 8 14 26 35 159.85 164.05 258.57 338.01 4 4 53/8 7 1/2 8 1/2 75/8 8 10 *75-500 is also UL certified for UL 1950, IEC 950 and IEC1010 with thermal breaker, CE marked. c Input Plug: 100 VA-1500 VA N NEMA 5-15P; 2000 VA and 2500 VA: NEMA L5-30 Twist Lock c These Units Do Not Change Frequency Dimensions VA Size The UL/Classified is for the EU Series c c c c c c c c c Mounting European (Schuko) H W D MW MD Wt. (Lbs.) 31/2 37/8 45/8 45/8 55/16 57/8 57/8 65/16 2 7/8 3 3/16 3 13/16 3 13/16 4 7/16 4 5/16 4 5/16 5 5/16 4 1/8 5 1/8 5 1/2 6 1/2 6 3/4 7 7 3/4 9 1/8 21/ 4 21/ 2 3 3 31/ 2 37/ 16 37/ 16 41/ 4 3 4 47/ 16 57/ 16 51/ 4 55/ 8 63/ 8 75/ 8 3.8 6.7 10.0 13.0 16.4 16.7 21.3 38.0 Power Cords Matched To Country Of Use North American Stock No. Mfr.Os Type EACH 1-9 Stock No. Mfr.Os Type EACH 704-8400 704-8410 704-8415 704-8420 704-8425 704-8430 704-8435 704-7640 TSU-100-EU TSU-350-EU TSU-500-EU TSU-750-EU TSU-1000-EU TSU-1500-EU TSU-2000-EU TSU-2500-EU 82.95 77.77 87.69 100.72 196.24 337.13 567.87 535.31 704-7645 704-7655 704-7660 704-7665 704-7670 704-7675 704-7680 704-7685 TSU-100-NA TSU-350-NA TSU-500-NA TSU-750-NA TSU-1000-NA TSU-1500-NA TSU-2000-NA TSU-2500-NA 67.35 87.98 99.54 120.39 185.45 241.93 409.29 521.90 1-9 Stock No. Mfr.Os Type Country of Use Fig. EACH 704-7533 75C-3300 A OSchukoO European (10 A Version 12.80 of above both useable Brazil/Argentina) 704-7520 75C-2004 B United Kingdom BS1363 (will not mate 20.84 with BS546-Standard Prior to 1954) 704-7541 75C-4100 C Australia/New Zealand 16.70 704-7537 75C-37030 D North American Nema 5-15 (Japan, Vietnam and Phillipines) 12.07 Isolation Transformers c Primary 115/230 V or 230/460 V c Popular Sizes: 50 VA-2000 VA Primary 115/230 V 17 Stock No. Mfr.Os Type Fig. Primary Secondary VA Size W D MW MD Weight (Lbs.) EACH H Dimensions Mounting 704-0050 704-0051 704-0052 704-0053 704-0054 704-0055 704-0056 704-0057 23V601 23V602 23V603 23V604 23V605 23V606 23V607 23V608 A A B B B B B B 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 50 100 250 500 750 1000 1500 2000 2 9/16 2 9/16 3 13/16 4 7/16 4 7/16 5 11/16 5 11/16 5 11/16 3 3 41/2 51/4 51/4 63/4 63/4 63/4 23/4 35/8 33/4 5 61/4 65/8 71/4 8 21/2 21/2 33/4 43/8 43/8 61/8 61/8 61/8 23/ 8 31/ 4 27/ 8 33/ 4 415/16 4 53/ 8 61/ 8 3.5 5.0 9.5 18.0 24.5 30.5 44.0 52.5 30.63 31.94 59.90 99.50 116.20 146.36 232.43 275.09 A B B B B B B 230/460 230/460 230/460 230/460 230/460 230/460 230/460 115/230 115/230 115/230 115/230 115/230 115/230 115/230 100 250 500 750 1000 1500 2000 2 9/16 3 13/16 4 7/16 4 7/16 5 11/16 5 11/16 5 11/16 3 41/2 51/4 51/4 63/4 63/4 63/4 35/8 33/4 5 61/4 65/8 71/4 8 21/2 33/4 43/8 43/8 61/8 61/8 61/8 31/ 4 27/ 8 33/ 4 415/16 4 53/ 8 61/ 8 5.0 9.5 18.0 24.5 30.5 44.0 52.5 34.52 55.75 93.37 108.41 146.36 224.59 265.71 1-9 Primary 230/460 V 704-0058 704-0059 704-0060 704-0061 704-0062 704-0063 704-0065 1056 b ALLIED 23V609 23V610 23V611 23V612 23V613 23V614 23V615 Call Your Nearest Allied Location (1-800-433-5700) For Quick Service