Oscilloscope Probes and
Probe Accessories
2
Teledyne LeCroy has a wide variety of world class probes and ampliers to compliment its
product line. From the ZS high impedance active probes to the WaveLink differential probing
system which offers bandwidths up to 25 GHz, Teledyne LeCroy probes and probe
accessories provide optimum mechanical connections for signal measurement.
Front Cover:
ZS Series High Impedence
Active Probes
PROBE SELECTION
GUIDE
Active Voltage Probes - p. 4 - 7
ZS1000
✓✓✓✓✓✓✓✓✓✓✓
ZS1500
✓✓✓✓✓✓✓✓✓✓
ZS2500
✓✓✓✓
ZS4000
✓✓✓✓
Current Probes - p. 8 -11
CP030
✓✓✓✓✓✓✓✓✓✓✓
CP030A
✓✓✓✓✓✓✓✓✓✓✓
CP031
✓✓✓✓✓✓✓✓✓✓✓
CP031A
✓✓✓✓✓✓✓✓✓✓✓
CP150
✓✓✓✓✓✓✓✓✓✓✓
CP500
✓✓✓✓✓✓✓✓✓✓✓
CA10
✓✓✓✓✓✓✓✓✓
Differential Probes - p. 12 - 21
ZD200
✓✓✓✓✓✓✓✓✓✓✓✓
ZD500
✓✓✓✓✓✓✓✓✓✓✓✓
ZD1000
✓✓✓✓✓✓✓✓✓✓✓✓
ZD1500
✓✓✓✓✓✓✓✓✓✓✓
AP033
✓✓✓✓✓✓✓✓✓✓✓
D410-PS
✓✓✓✓
D420-PS
✓✓✓✓
D400A-AT
✓✓✓✓
D610-PS
✓✓✓✓
D620-PS
✓✓✓✓
D600A-AT
✓✓✓✓
D830-PS
✓✓✓
D1030-PS
✓✓✓
D1330-PS
✓✓✓
D1305-A-PS
✓✓✓
D1605-A-PS
✓✓✓
D2005-A-PS
✓✓✓
D2505-A-PS
✓✓✓
High Voltage Differential Probes - p. 22 - 27
HVD3102
✓✓✓✓✓✓✓✓✓✓✓
HVD3106
✓✓✓✓✓✓✓✓✓✓✓
HVD3106-6M
✓✓✓✓✓✓✓✓✓✓✓
HVD3206
✓✓✓✓✓✓✓✓✓✓✓
HVD3605
✓✓✓✓✓✓✓✓✓✓✓
ADP300
✓✓✓✓✓✓✓✓✓✓✓
ADP305
✓✓✓✓✓✓✓✓✓✓✓
AP031
✓✓✓✓✓✓✓✓✓✓✓✓✓
HRO 12-bit Oscilloscopes
LabMaster 9 Zi-A Oscilloscopes
WaveAce Oscilloscopes
WaveJet Oscilloscopes
WavePro/SDA/DDA/7 Zi/7 Zi-A
Oscilloscopes
WaveRunner 6 Zi
Oscilloscopes
HDO6000 / HDO6000-MS
High Definition Oscilloscopes
WaveMaster/SDA/DDA/8 Zi/Zi-B
Oscilloscopes
WaveSurfer 10 / MXs-B / MSO
MXs-B Oscilloscopes
LabMaster 10 Zi-A Oscilloscopes
HDO4000 / HDO4000-MS
High Definition Oscilloscopes
WaveSurfer 3000 Oscilloscopes
HDO8000 / HDO8000-MS
High Definition Oscilloscopes
MDA800 Motor Drive Analyzers
3
Differential Amplifiers - p. 28 - 31
DXC200
✓✓✓✓✓✓✓✓✓✓✓✓
DA101
✓✓✓✓✓✓✓✓✓✓✓✓
DA1855A
✓✓✓✓✓✓✓✓✓✓✓✓
DA1855A-PR2
✓✓✓✓✓✓✓✓✓✓✓✓
DA1855A-PR2-RM
✓✓✓✓✓✓✓✓✓✓✓✓
DA1855A-RM
✓✓✓✓✓✓✓✓✓✓✓✓
DXC-5100
✓✓✓✓✓✓✓✓✓✓✓✓
DXC100A
✓✓✓✓✓✓✓✓✓✓✓✓
High Voltage Probes - p. 32 - 37
HVP120
✓✓✓✓✓✓✓✓✓✓✓✓✓
PPE1.2KV
✓✓✓✓✓✓✓✓✓✓✓✓✓
PPE2KV
✓✓✓✓✓✓✓✓✓✓✓✓✓
PPE4KV
✓✓✓✓✓✓✓✓✓✓✓✓✓
PPE5KV
✓✓✓✓✓✓✓✓✓✓✓✓✓
PPE6KV
✓✓✓✓✓✓✓✓✓✓✓✓✓
Optical Probes - p. 38 - 41
OE425
✓✓✓✓
OE455
✓✓✓✓
OE525
✓✓✓✓
OE555
✓✓✓✓
OE695G
✓✓✓✓
Passive Probes - p. 42 - 45
PP006A
PP007-WR
✓✓✓
PP008
PP009
PP010
PP011
PP016
PP017
PP018
PP019
PP020
Probe Adapters - p. 46 -49
CA10
✓✓✓✓✓✓✓✓✓
TPA10
✓✓✓✓✓✓✓✓✓✓✓
Transmission Line Probes - p. 50 - 51
PP066
✓✓✓✓
Note: Some probes require purchase of the amplifier and platform/cable assembly separately – Reference detailed literature for more information.
LabMaster 10 Zi-A Oscilloscopes
HRO 12-bit Oscilloscopes
LabMaster 9 Zi-A Oscilloscopes
WaveAce Oscilloscopes
WaveJet Oscilloscopes
WavePro/SDA/DDA/7 Zi/7 Zi-A
Oscilloscopes
WaveRunner 6 Zi
Oscilloscopes
HDO6000 / HDO6000-MS
High Definition Oscilloscopes
WaveMaster/SDA/DDA/8 Zi/Zi-B
Oscilloscopes
WaveSurfer 10 / MXs-B / MSO
MXs-B Oscilloscopes
LabMaster 10 Zi-A Oscilloscopes
HDO4000 / HDO4000-MS
High Definition Oscilloscopes
WaveSurfer 3000 Oscilloscopes
HDO8000 / HDO8000-MS
High Definition Oscilloscopes
MDA800 Motor Drive Analyzers
4
ACTIVE VOLTAGE PROBES
4
5
ACTIVE VOLTAGE PROBES
Teledyne LeCroy
Active Voltage Probe
Model Numbers:
ZS1000
ZS1500
ZS2500
ZS4000
Opposite page:
ZS Series High Impedance Active Probe
Engineers must commonly probe high-frequency signals with high
signal delity. Typical passive probes with high input R and C provide good
response at lower frequencies, but inappropriately load the circuit and
distort signals at higher frequencies. Active voltage probes feature both
high input R and low input C to reduce circuit loading across the entire
probe/oscilloscope bandwidth. With low circuit loading and a form factor
that allows probing in conned areas, the active voltage probe becomes
the everyday probe for all different types of signals and connection points.
6
ZS SERIES ACTIVE PROBES
Teledyne LeCroy
Active Voltage Probe
Model Numbers:
ZS1000
ZS1500
ZS2500
ZS4000
The ZS Series probes are high impedance, low capacitance active probes that
maintain high signal delity through 4 GHz. A small form factor and a wide variety
of accessories ensures the ZS probe meets every difcult probing challenge.
Engineers must commonly probe high frequency signals with high signal delity.
Typical passive probes with high input R and C provide good response at lower
frequencies but inappropriately load the circuit and distort signals at higher
frequencies. The ZS Series features both high input R (1 MΩ) and low input C
(0.6 pF and 0.9 pF) to reduce circuit loading across the entire probe/oscilloscope
bandwidth. The ZS1000 is ideal for 200–600 MHz oscilloscopes. The ZS1500 is
ideal for 1 GHz oscilloscopes, the ZS2500 is ideal for 2 GHz oscilloscopes, and the
ZS4000 is ideal for 2.5 GHz and 4 GHz oscilloscopes.
PK-ZS-009
Copper Tape
PACC-PT005
Bent Tip
PK-ZS-024
2.54 mm PCB
Adapter
PACC-PT003
IC Tip
PK-ZS-017
Pogo Tip
PK-ZS-001
Probe Tip - Standard
PK-ZS-014
Y-Lead
Adapter
PK-ZS-010
Channel ID
Colored Clips
PK-ZS-019
Freehand Probe Holder
PK-ZS-023
Straight Pin
Lead - 13cm
PK-ZS-022
Straight Pin
Lead - 7cm
PACC-LD004
Right Angle
Pin Lead - 10cm
PK-ZS-007B
Microclip Sprung
Hook, Black
PK-ZS-007R
Microclip Sprung
Hook, Red
PK-ZF-025
QFPIC Clip Green -
Short
PK-ZF-025
QFPIC Clip Yellow -
Short
PACC-LD003
Right Angle
Pin Lead - 5cm
PK-ZS-006
Right Angle Socket
PK-ZS-021
Ground Blade -
Narrow
PK-ZS-015
Ground Blade - Wide
PK-ZS-016
Offset Ground
(Z Lead)
PK-ZS-020
Pogo Ground Lead
PK-ZS-018
2.54 mm Square
Pin Adapter
ZS4000
7
ZS SERIES ACTIVE PROBES
PK-ZS-009
Copper Tape
PACC-PT005
Bent Tip
PACC-PT003
IC Tip
PK-ZS-005
Y-Lead
Adapter
PK-ZS-010
Channel ID
Colored Clips
PK-ZS-004
Single Lead -
Long
PK-ZS-003
Single Lead -
Short
PACC-LD004
Right Angle
Lead - Long
PK-ZS-007B
Microclip Sprung
Hook, Black
PK-ZS-007R
Microclip Sprung
Hook, Red
PACC-LD003
Right Angle
Pin Lead - 5cm
PK-ZS-006
Right Angle Socket
PK-ZS-008
Ground Blade - Narrow
PK-ZS-011
Ground Blade - Wide
PK-ZS-002
Offset Ground
PACC-CD008
Pogo Ground Lead
PK-ZS-012
2.54 mm Square Pin
Adapter
PK-ZS-001
Probe Tip - Standard
Qty: 3
PK-ZS-013
Pogo Tip
PACC-MS005
Freehand Probe Holderk
ZS1000
ZS1500
ZS2500
Specications ZS1000 ZS1500 ZS2500 ZS4000
Electrical Characteristics
Probe Bandwidth 1 GHz 1.5 GHz 2.5 GHz 4 GHz
Input Capacitance 0.9 pF 0.6 pF
DC Input Resistance 1 MΩ
Probe Offset Range N/A ±12 V
Attenuation ÷10
Input Dynamic Range ±8 V
Non-destruct Voltage 20 V
General Characteristics
Cable Length 1.3 m
Ordering Information
Product Description Product Code
4 GHz, 0.6 pF, 1 MΩ
High Impedance Active Probe ZS4000
2.5 GHz, 0.9 pF, 1 MΩ
High Impedance Active Probe ZS2500
1.5 GHz, 0.9 pF, 1 MΩ
High Impedance Active Probe ZS1500
1 GHz, 0.9 pF, 1 MΩ
High Impedance Active Probe ZS1000
Set of 4 ZS2500, 2.5 GHz, 0.9 pF, 1 MΩ
High Impedance Active Probes ZS2500-QUADPAK
Set of 4 ZS1500, 1.5 GHz, 0.9 pF, 1 MΩ
High Impedance Active Probes ZS1500-QUADPAK
Set of 4 ZS1000, 1 GHz, 0.9 pF, 1 MΩ
High Impedance Active Probes ZS1000-QUADPAK
Standard Accessory/Quantity
Accessory Description Replacement
Part Number
ZS1000
ZS1500
ZS2500 ZS4000
2.54 mm PCB Adaptor PK-ZS-024 5
2.54mm Square Pin Adapter PK-ZS-012 1
2.54mm Square Pin Adaptor PK-ZS-018 1
IC Tip PACC-PT003 1 1
Bent Tip PACC-PT005 1 1
Channel ID Clips
(Set of 4 colors) PK-ZS-010 4 1
Copper Tape Pad PK-ZS-009 2 2
Freehand Probe Holder PK-ZS-019 1
Freehand Probe Holder PACC-MS005 1
Ground Blade – Narrow PK-ZS-008 1
Ground Blade – Wide PK-ZS-011 1
Ground Blade, Narrow PK-ZS-021 1
Ground Blade, Wide PK-ZS-015 2
Micro-Grabber Pair PK-ZS-007R and
PK-ZS-007B 1 2
Offset Ground PK-ZS-016 2
Accessory Description Replacement
Part Number
ZS1000
ZS1500
ZS2500 ZS4000
Offset Ground – Z Lead PK-ZS-002 1
Pogo Ground Lead PK-ZS-020 1
Pogo Ground Lead PACC-CD008 1
Pogo Tip PK-ZS-017 3
Pogo Tip PK-ZS-013 1
Probe Tip – Standard PK-ZS-001 3 3
QFPIC Clips (set of 2) PK-ZS-025 1
Right Angle Lead – Long PACC-LD004 1 1
Right Angle Lead – Short PACC-LD003 1 1
Right Angle Socket PK-ZS-006 1 1
Straight Pin Lead – Long PK-ZS-023 1
Straight Pin Lead – Long PK-ZS-004 1
Straight Pin Lead – Short PK-ZS-022 1
Straight Pin Lead – Short PK-ZS-003 1
Y Lead Adapter PK-ZS-005 1
Y Lead Adaptor PK-ZS-014 1
8
CURRENT PROBES
8
9
CURRENT PROBES
Opposite page:
CP031, 30A, 100 MHz Current Probe.
Teledyne LeCroy
Current Probe
and Adapter
Model Numbers:
CP030
CP030A
CP031
CP031A
CP150
CP500
DCS015
CA10
Teledyne LeCroy current probes do not require the breaking of a
circuit or the insertion of a shunt to make accurate and reliable
current measurements. Based on a combination of Hall effect and
transformer technology, Teledyne LeCroy current probes are ideal for
making accurate AC, DC, and impulse current measurements.
Wide Range of Applications
Teledyne LeCroy current probes are available in a variety of models for a
wide range of applications. The full range of Teledyne LeCroy current probes
includes models with bandwidths up to 100 MHz, peak currents up to
700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often
used in applications such as the design and test of switching power supplies,
motor drives, electric vehicles, and uninterruptible power supplies.
High Sensitivity
The CP030A and CP031A provide a high sensitivity of 1 mA/div. This
allows for more precise low current measurements on Teledyne LeCroy
oscilloscopes. When used with HDO high denition oscilloscopes with
HD4096 technology, users will obtain highly accurate, low current waveforms
with unmatched 12-bit resolution for improved debug and analysis.
Fully Integrated
All Teledyne LeCroy current probes are powered through the Teledyne LeCroy
ProBus® connection and require no additional hardware. Along with providing
power, the ProBus connection allows the current probe and oscilloscope to
communicate, resulting in current waveforms automatically displayed on
screen in Amps, and calculated power traces scaled correctly in Watts. This
full integration also allows for Degauss and Autozero functions to be done
directly from the oscilloscope’s user interface.
Deskew Calibration Source
The DCS015 deskew calibration source has both voltage and current time-
aligned signals, which enables the precise deskew of voltage and current
probes. Most voltage probes along with the CP030, CP030A, CP031, and
CP031A are compatible with the DSC015.
10
CURRENT PROBES
DCS015
Precise deskew of voltage and
current probes.
Compatible with the
CP031,CP031A,
CP030, and CP030A
Teledyne LeCroy
Current Probe
and Adapter
Model Numbers:
CP030
CP030A
CP031
CP031A
CP150
CP500
DCS015
CA10
Features
ProBus active probe interface withautomatic scaling in A/div
Autozero and degauss capabilities built into instrument’s user interface
Wide range of input currents and bandwidth capabilities
CP030
30 Arms continuous current
50 Apeak current
50 MHz bandwidth
CP030A
30 Arms continuous current
50 Apeak current
50 MHz bandwidth
1 mA/div sensitivity
CP031
30 Arms continuous current
50 Apeak current
100 MHz bandwidth
CP031A
30 Arms continuous current
50 Apeak current
100 MHz bandwidth
1 mA/div sensitivity
CP150
150 Arms continuous current
500 Apeak current
10 MHz bandwidth
CP500
500 Arms continuous current
700 Apeak current
2 MHz bandwidth
11
CURRENT PROBES
Product Description Product Code
ProBus Current Sensor Adapter CA10
Set of 4 CA10, ProBus Current Sensor Adapters CA10-QUADPAK
30 A; 50 MHz Current Probe – AC/DC; 30 Arms; 50 A Peak Pulse CP030
30 A; 50 MHz High Sensitivity Current Probe – AC/DC; 30 Arms; 50 A Peak Pulse CP030A
30 A; 100 MHz Current Probe – AC/DC; 30 Arms; 50 A Peak Pulse CP031
30 A; 100 MHz High Sensitivity Current Probe – AC/DC; 30 Arms; 50 A Peak Pulse CP031A
150 A; 10 MHz Current Probe – AC/DC; 150 Arms; 500 A Peak Pulse CP150
500 A; 2 MHz Current Probe – AC/DC; 500 Arms; 700 A Peak Pulse CP500
Deskew Calibration Source for CP031,CP031A, CP030, CP030A and AP015 DCS015
Ordering Information
CA10 Current Sensor Adapter
The CA10 enables a third-party current measurement device to operate like a Teledyne
LeCroy probe. The CA10 is programmable and customizable to work with third-party
current measurement devices that output voltage or current signals proportional to
measured current. (See page 48 for more information and specications).
Specications CP030CP030ACP031CP031ACP150 CP500
Electrical Characteristics*
Max. Continuous
Input Current 30 Arms 150 Arms 500 Arms
Bandwidth 50 MHz 100 MHz 10 MHz 2 MHz
Rise Time (typical) 7 ns 3.5 ns 35 ns 175 ns
Max. Peak Current 50 Apeak (non-continuous) 300 Apeak non-continuous;
500 Apeak ≤ 30 µs
700 Apeak
non-continuous
Output Voltage 0.1 V/A 0.1 V/A & 1 V/A 0.1 V/A 0.1 V/A & 1 V/A 0.01 V/A
Max Continuous Input Current
at 1 V/A (100mA/div or less) 5 A 5 A
Offset Range at 1V/A
(100mA/div or less) ±5 A ±5 A
Minimum Sensitivity 10 mA/div 1 mA/div 10 mA/div 1 mA/div 100 mA/div
Low-Frequency Accuracy 1%
AC Noise at 20 MHz BWL 2.5 mA 150 µA 2.5 mA 150 µA 6.0 mA 8.0 mA
Coupling AC, DC, GND
General Characteristics
Cable Length 1.5 m 2 m 6 m
Weight 240 g 260 g 240 g 260 g 500 g 630 g
Max. Conductor Size
(Diameter) 5 mm 20 mm
Interface ProBus, 1 MΩ only
Usage Environment Indoor
Operating Temperature 0˚ C to 40˚ C
Max. Relative Humidity 80%
Max. Altitude 2000 m
Maximum Insulated
Wire Voltage 300 V CAT I 600 V CAT II, 300 V CAT III
* Electrical Characteristics Guaranteed at 23 °C ±3 °C
The CP031 and CP030 require the Teledyne LeCroy oscilloscope to be running rmware version 4.3.1.1 or greater. The CP031A and CP030A require
rmware version 7.8.x.x or greater.
12
12
DIFFERENTIAL PROBES
13
DIFFERENTIAL PROBES
Opposite page:
WaveLink® High Bandwidth Differential Probing System
(13 GHz – 25 GHz)
Differential active probes are like two probes in one. Instead of measuring
a test point in relation to a ground point (like single-ended active probes),
differential probes measure the difference in voltage of a test point in
relation to another test point.
Teledyne LeCroy
Differential Probe
Model Numbers:
1.5 GHz
ZD200
ZD500
ZD1000
ZD1500
AP033
4 GHz - 6 GHz
D410-PS
D420-PS
D400A-AT
D610-PS
D620-PS
D600A-AT
8 GHz - 13 GHz
D830-PS
D1030-PS
D1330-PS
13 GHz - 25 GHz
D1305-PS
D1605-PS
D2005-PS
D2505-PS
14
1.5 GHz DIFFERENTIAL PROBES
The ZD Series probes provide wide dynamic range, excellent noise and loading
performance and an extensive set of probe tips, leads, and ground accessories
to handle a wide range of probing scenarios. The low 1 pF capacitance means
this probe is ideal for all frequencies. The ZD Series differential probes provide full
system bandwidth for all Teledyne LeCroy Oscilloscopes 1.5 GHz and lower.
Fully Integrated
With the ProBus interface, the ZD500, 1000, and 1500 become an integral part
of the oscilloscope. All probe gain and offset controls are transparent to the user,
making it easier to probe the circuit without concern for which gain setting to
choose. When used with a Teledyne LeCroy digital oscilloscope, no external power
supply is required.
Wide Dynamic Range
The ZD500, 1000, 1500 probes provide transparent probe attenuation so signals are
always optimized for the display. The differential range is 18 Vp-p with a differential
offset of ±8V and common mode range of ±10 V, making these probes versatile for
every probing application.
Wide Applications
The wide dynamic range of 16 Vp-p and offset range of ±8V suit this probe to a wide
range of applications and signal types. The ZD differential probes are ideally suited
for Automotive, Serial Data, power, and general purpose use.
Specications ZD200 ZD500 ZD1000 ZD1500
Electrical Characteristics
Bandwidth (Warranted) 200 MHz 500 MHz 1000 MHz 1500 MHz
Bandwidth (Typical) -650 MHz 1200 MHz 1700 MHz
Risetime 10–90% (Typical) 1.75 ns 650 ps 375 ps 270 ps
Risetime 20–80% (Typical) -500 ps 280 ps 200 ps
LF Attenuation Accuracy (Warranted) 1% 2%
Zero Offset (Typical)
(within 15 minutes after autozero) -5 mV
System Noise (Typical) -1.3 mVrms 1.75 mVrms
Probe Noise Density (Typical) 3 mVrms 38 nV/rt (Hz)
Input Differential Range (Nominal) ± 20 V ±8 V (16 Vp-p)
Differential Offset Range (Nominal) -±18 V
Offset Gain Accuracy (Typical) -2%
Common Mode Range (Nominal) ± 60 V ±10 V
Maximum Non-destruct Voltage
(Nominal) -30 V
CMRR (Typical) 80 dB @ 60 Hz
50 dB@10 MHz 60 dB 50/60 Hz
30 dB 20 MHz
25 dB 500 MHz
60 dB 50/60 Hz
30 dB 20 MHz
25 dB @ 1000 MHz
60 dB 50/60 Hz
30 dB 20 MHz
25 dB @ 1500 MHz
DC Input Resistance (Nominal) 250 kΩ (Common Mode)
1 MΩ (Differential Mode) 50 kΩ (Common Mode)
120 kΩ (Differential Mode)
Differential Input Capacitance
(Typical) 3.5 pF < 1.0 pF
Teledyne LeCroy
1.5 GHz
Differential Probe
Model Numbers:
ZD200
ZD500
ZD1000
ZD1500
AP033
15
1.5 GHz DIFFERENTIAL PROBES
AP033
High bandwidth, excellent common-mode rejection ratio
(CMRR) and low noise make these active differential
probes ideal for applications such as disk drive design
and failure analysis, as well as wireless and data
communication design.
Ordering Information
Product Description Product Code
500 MHz Differential Probe AP033
Specications
Bandwidth 500 MHz
Gain x10, x1, ÷10 (÷100 with
plug-on ÷10 attenuator)
DC Accuracy 1% in x1 without
external attenuator
Input Resistance 1 MΩ each input to ground
2 MΩ differential between inputs
Differential Mode Range ±400 mV (x1)
±40 mV (x10)
±4 V (÷10)
±40 V (÷100)
Offset Range ±400 mV (x1, x10)
±4 V (±10)
±40 V (±100)
Common-Mode Range ±42 V peak (±10)
+4.2 V peak (±100)
CMRR 70 Hz 10,000:1 (80 dB)
100 kHz 10,000:1 (80 dB)
1 MHz 1000:1 (60 dB)
10 MHz 100:1 (40 dB)
250 MHz 5:1 (14 dB)
PACC-MS001
Hands Free Probe Holder
PACC-ZD001
Y Lead
Adapter
PACC-ZD002
Solder-In-Lead
Qty: 2
PACC-ZD004
Tip Saver
Qty: 2
PACC-ZD005
Swivel Tip Adapter
PACC-PT001
Straight Tip
Qty: 4
PACC-ZD006
Small IC Adapter
Qty: 2
PACC-CD008
Spring-loaded
Ground (Short)
Qty: 2
PACC-ZD003
Spring-loaded
Ground (Long)
Qty: 2
PACC-LD004
Right Angle
Connector (long)
Qty: 2
PACC-LD003
Right Angle
Connector (Short)
Qty: 2
PK006-4
Micro-Grabber
Qty: 2
PACC-CL001
Mini-Grabber
Qty: 2
PCF200
Probe Calibration Fixture
ZD1500 / ZD1000 / ZD500 Probe
PACC-MS001
Hands Free Probe Holder
PACC-ZD001
Y Lead
Adapter
PACC-ZD002
Solder-In-Lead
Qty: 2
PACC-ZD004
Tip Saver
Qty: 2
PACC-ZD005
Swivel Tip Adapter
PACC-PT001
Straight Tip
Qty: 4
PACC-ZD006
Small IC Adapter
Qty: 2
PACC-CD008
Spring-loaded
Ground (Short)
Qty: 2
PACC-ZD003
Spring-loaded
Ground (Long)
Qty: 2
PACC-LD004
Right Angle
Connector (long)
Qty: 2
PACC-LD003
Right Angle
Connector (Short)
Qty: 2
PK006-4
Micro-Grabber
Qty: 2
PACC-CL001
Mini-Grabber
Qty: 2
PCF200
Probe Calibration Fixture
ZD1500 / ZD1000 / ZD500 Probe
PACC-MS001
Hands Free Probe Holder
PACC-ZD001
Y Lead
Adapter
PACC-ZD002
Solder-In-Lead
Qty: 2
PACC-ZD004
Tip Saver
Qty: 2
PACC-ZD005
Swivel Tip Adapter
PACC-PT001
Straight Tip
Qty: 4
PACC-ZD006
Small IC Adapter
Qty: 2
PACC-CD008
Spring-loaded
Ground (Short)
Qty: 2
PACC-ZD003
Spring-loaded
Ground (Long)
Qty: 2
PACC-LD004
Right Angle
Connector (long)
Qty: 2
PACC-LD003
Right Angle
Connector (Short)
Qty: 2
PK006-4
Micro-Grabber
Qty: 2
PACC-CL001
Mini-Grabber
Qty: 2
PCF200
Probe Calibration Fixture
ZD1500 / ZD1000 / ZD500 Probe
Ordering Information
Product Description Product Code
200 MHz, 3.5 pF, 1 MΩ Active Differential Probe ZD200
500 MHz, 1.0 pF Active Differential Probe, ±8 V ZD500
1 GHz, 1.0 pF Active Differential Probe, ±8 V ZD1000
1.5 GHz, 1.0 pF Active Differential Probe, ±8 V ZD1500
15
16
4 GHz - 6 GHz DIFFERENTIAL PROBES
WaveLink® probes provide industry leading technology for wideband signal
connection to test instruments. The rst differential probes to employ SiGe
technology, they deliver full system bandwidth when used with oscilloscopes
up to 6 GHz.
WaveLink probes:
Maintain good loading characteristics across the frequency span
Optimized for gain, noise and bandwidth for optimal performance
Offer broad range of dynamic range and noise over gain settings by
incorporating automatic probe attenuation changes
WaveLink is the rst differential probe to use a unique calibration process
to achieve superb waveform delity for routine voltage measurements.
Calibration coefcients “ne tune” the frequency response of each WaveLink
probe and are individually determined during factory calibration and programmed
into the probe. The oscilloscopes read this data and use it to digitally compensate
the entire system response for superior delity.
D400A-AT
WL-PLINK-CASE
ProLink
WL-PBUS-CASE
ProBus
D600A-AT
D610
6 GHz
D410
4 GHz
D620
6 GHz
D420
4 GHz
Dx10-SI
Dx10-QC
Dx10-SP
Dx10-PT-KIT
(Included in Dx10-PS)
Dx10-HITEMP
(OPTIONAL)
Dx20-SI
Dx20-QC
Dx20-SP
Dx20-PT-KIT
(Included in Dx20-PS)
Dx20-HITEMP
(OPTIONAL)
Teledyne LeCroy
4 GHz - 6 GHz
Differential Probe
Model Numbers:
D410-PS
D420-PS
D400A-AT
D610-PS
D620-PS
D600A-AT
17
4 GHz - 6 GHz DIFFERENTIAL PROBES
D610, D610-PS D620, D620-PS D410, D410-PS D420, D420-PS D600A-AT D400A-AT
Bandwidth*
(Probe Only, Guaranteed)
(System Bandwidth, Typical)
Dx10-SI and
Dx10-PT Tips
6 GHz
Dx10-HiTemp
5 GHz
Dx10-QC Tip
4 GHz
Dx10-SP Tip
3 GHz
Dx20-SI and
Dx20-PT Tips
6 GHz
Dx20-HiTemp
5 GHz
Dx20-QC Tip
4 GHz
Dx20-SP Tip
3 GHz
Dx10-SI, Dx10-HiTemp,
Dx10-QC and Dx10-PT Tips
4 GHz
Dx10-SP Tip
3 GHz
Dx20-SI, Dx20-HiTemp,
Dx20-QC and Dx20-PT Tips
4 GHz
Dx20-SP Tip
3 GHz
6 GHz 4 GHz
Rise Time* (10–90%) Dx10-SI and
Dx10-PT Tips
75 ps (typical)
Dx10-HiTemp
90 ps (typical)
Dx10-QC Tip
122.5 ps (typical)
Dx10-SP Tip
150 ps (typical)
Dx20-SI and
Dx20-PT Tips
75 ps (typical)
Dx20-HiTemp
90 ps (typical)
Dx20-QC Tip
122.5 ps (typical)
Dx20-SP Tip
150 ps (typical)
Dx10-SI, Dx10-HiTemp, and
Dx10-PT Tips
112 ps (typical)
Dx10-QC Tip
122.5 ps (typical)
Dx10-SP Tip
150 ps (typical)
Dx20-SI, Dx20-HiTemp, and
Dx20-PT Tips
112 ps (typical)
Dx20-QC Tip
122.5 ps (typical)
Dx20-SP Tip
150 ps (typical)
<75 ps (typical) <112 ps (typical)
Rise Time* (20–80%) Dx10-SI and
Dx10-PT Tips
56 ps (typical)
Dx10-HiTemp
67.5 ps (typical)
Dx10-QC Tip
92 ps (typical)
Dx10-SP Tip
113 ps (typical)
Dx20-SI and
Dx20-PT Tips
56 ps (typical)
Dx20-HiTemp
67.5 ps (typical)
Dx20-QC Tip
92 ps (typical)
Dx20-SP Tip
113 ps (typical)
Dx10-SI, Dx10-HiTemp, and
Dx10-PT Tips
84 ps (typical)
Dx10-QC Tip
92 ps (typical)
Dx10-SP Tip
113 ps (typical)
Dx20-SI, Dx20-HiTemp, and
Dx20-PT Tips
84 ps (typical)
Dx20-QC Tip
92 ps (typical)
Dx20-SP Tip
113 ps (typical)
56 ps (typical) 84 ps (typical)
Noise (System) <36 nV/√Hz
(2.8 mVrms) (typical)
Referred to input,
6 GHz bandwidth
<61 nV/√Hz
(4.8 mVrms) (typical)
Referred to input,
6 GHz bandwidth
<36 nV/√Hz
(2.3 mVrms) (typical)
Referred to input,
4 GHz bandwidth
<67 nV/√Hz
(4.3 mVrms) (typical)
Referred to input,
4 GHz bandwidth
<74 nV/√Hz
(5.8 mVrms) (typical)
Referred to input,
6 GHz bandwidth
<74 nV/√Hz
(4.1 mVrms) (typical)
Referred to input,
4 GHz bandwidth
Input
Input Dynamic Range
(Nominal) 2.5Vpk-pk, ±1.25V 5Vpk-pk, ±2.5V 2.5Vpk-pk, ±1.25V 5Vpk-pk, ±2.5V 4.8Vpk-pk, ±2.4V
Input Common Mode Voltage
Range (Nominal) ±4 V ±2.4 Vmax
Input Offset Voltage Range ±3 V Differential (nominal) n/a
Non-destructive
Input Range (Nominal) ±20 V ±18 V
Attenuation 1.7X / 1.0X (nominal) 3.2X / 1.9X (nominal) 1.7X / 1.0X (nominal) 3.2X / 1.9X (nominal) 2.5X
DC Input Resistance
(Nominal)
100 kΩ Differential
50 kΩ Common Mode
4 kΩ Differential
2 kΩ Common Mode
Impedance
(Zmin, Typical)
Dx10-SI Lead,
Dx10-HiTemp
>175 Ω Differential
Dx10-PT Tip
>175 Ω Differential
Dx10-QC Tip
>125 Ω Differential
Dx10-SP Tip
>40 Ω Differential
Dx20-SI Lead,
Dx20-HiTemp
>250 Ω Differential
Dx20-PT Tip
>175 Ω Differential
Dx20-QC Tip
>125 Ω Differential
Dx20-SP Tip
>40 Ω Differential
Dx10-SI Lead,
Dx10-HiTemp
>200 Ω Differential
Dx10-PT Tip
>175 Ω Differential
Dx10-QC Tip
>100 Ω Differential
Dx10-SP Tip
>40 Ω Differential
Dx20-SI Lead,
Dx20-HiTemp
>350 Ω Differential
Dx20-PT Tip
>175 Ω Differential
Dx20-QC Tip
>100 Ω Differential
Dx20-SP Tip
>40 Ω Differential
>200 Ω Differential >450 Ω Differential
through entire
frequency range
Product Description Product Code
Complete Probe Systems
4 GHz Complete Probe System with Dx10-SI Solder-In Tip (Qty. 1),
Dx10-SP Square Pin (Qty. 1), Dx10-QC Quick Connect (Qty. 1), and
Dx10-PT-KIT Positioner Tip Browser (Qty. 1)
D410-PS
4 GHz Complete Probe System with Dx20-SI Solder-In Tip (Qty. 1),
Dx20-SP Square Pin (Qty. 1), Dx20-QC Quick Connect (Qty. 1), and
Dx20-PT-KIT Positioner Tip Browser (Qty. 1)
D420-PS
6 GHz Complete Probe System with Dx10-SI Solder-In Tip (Qty. 1),
Dx10-SP Square Pin (Qty. 1), Dx10-QC Quick Connect (Qty. 1), and
Dx10-PT-KIT Positioner Tip Browser (Qty. 1)
D610-PS
6 GHz Complete Probe System with Dx20-SI Solder-In Tip (Qty. 1),
Dx20-SP Square Pin (Qty. 1), Dx20-QC Quick Connect (Qty. 1), and
Dx20-PT-KIT Positioner Tip Browser (Qty. 1)
D620-PS
Amplier and Probe Tip Modules
WaveLink D410 4 GHz/2.5Vp-p Differential Probe Amplier with
Dx10-SI Solder-In Tip (Qty. 1), Dx10-SP Square Pin (Qty. 1), and
Dx10-QC Quick Connect (Qty. 1)
D410
WaveLink D420 4 GHz/5Vp-p Differential Probe Amplier with
Dx20-SI Solder-In Tip (Qty. 1), Dx20-SP Square Pin (Qty. 1), and
Dx20-QC Quick Connect (Qty. 1)
D420
WaveLink D610 6 GHz/2.5Vp-p Differential Probe Amplier with
Dx10-SI Solder-In Tip (Qty. 1), Dx10-SP Square Pin (Qty. 1), and
Dx10-QC Quick Connect (Qty. 1)
D610
WaveLink D620 6 GHz/5Vp-p Differential Probe Amplier with
Dx20-SI Solder-In Tip (Qty. 1), Dx20-SP Square Pin (Qty. 1), Dx20-
QC Quick Connect (Qty. 1)
D620
Product Description Product Code
Amplier and Probe Tip Modules (cont’d)
WaveLink D300A-AT 4 GHz/4.8Vp-p Differential Amplier
Module with Adjustable Tip
D400A-AT
WaveLink D600A-AT 6 GHz/4.8Vp-p Differential Amplier
Module with Adjustable Tip
D600A-AT
Positioner Tip (Browser) Kits
WaveLink Dx10-PT Adjustable Positioner Tip Kit.
For use with Dx10 ampliers.
Dx10-PT-KIT
WaveLink Dx20-PT Adjustable Positioner Tip Kit.
For use with Dx20 ampliers.
Dx20-PT-KIT
Probe Platform/Cable Assemblies and Adapters
WaveLink ProLink Platform/Cable Assembly Kit with
complete soft carrying case for all probe items.
WL-PLINK-CASE
WaveLink ProBus Platform/Cable Assembly Kit with
complete soft carrying case for all probe items.
WL-PBUS-CASE
Hi-Temp Leads
WaveLink Temperature Extension Cables for Dx10.
Includes set of Matched 30" High Temperature Cables (Qty. 1)
and solder-in lead set (Qty. 1)
Dx10-HiTemp
WaveLink Temperature Extension Cables for Dx20.
Includes set of Matched 30" High Temperature Cables (Qty. 1)
and solder-in lead set (Qty. 1)
Dx20-HiTemp
* All bandwidth and rise time measurements are made with an oscilloscope bandwidth greater or equal to the probe bandwidth
Through entire frequency range
18
8 GHz - 13 GHz DIFFERENTIAL PROBES
General Purpose Probe with Range of Capabilities
Teledyne LeCroy’s WaveLink 8-13 GHz Differential Probes are a medium
bandwidth, general purpose probing solution with high input dynamic range and
offset range capability. These probes support solder-in, positioner (browser), square
pin and SMA/SMP cabled tip/lead connections. The range of capabilities is ideal
for a variety of high speed DDR signals where high dynamic range and large offset
requirements are common.
Features and Benets
Choice of 8, 10, or 13 GHz bandwidth models
3.5 Vpk-pk dynamic range
±4 V offset range
Ideal for DDR3, DDR4, LPDDR3
Deluxe soft carrying case
Wide variety of tips and leads
– Solder-In Lead
– Positioner (Browser) Tip
– SMA/SMP Lead
– Square Pin Lead
SMA/SMP lead set accessory does not require purchase of a different amplier
LabMaster 9 Zi-A/10 Zi
WaveMaster/SDA/DDA 8 Zi/Zi-A
WavePro/SDA/DDA 7 Zi/Zi-A
LabMaster 9 Zi-A/10 Zi
WaveMaster/SDA/
DDA 8 Zi/Zi-A 8 GHz
WL-PLINK-CASE
Platform/Cable Assembly
(Included in Dxx30-PS)
WL-PLINK-CASE
Platform/Cable Assembly
(Included in Dxx30-PS)
L2.92A-PLink
2.92mm to
ProLink Adapter
Dxx30-SP
Square Pin
Dxx30-SI
Solder-In Lead (Qty. 2)
Dxx30-SMA-SMP
SMA/SMP Lead Set
(Optional) Dxx30-PT
Positioner Tip Browser
(Included in Dxx30-PS)
Dxx30-SP
Square Pin
Dxx30-SI
Solder-In Lead (Qty. 2)
Dxx30-SMA-SMP
SMA/SMP Lead Set
(Optional) Dxx30-PT
Positioner Tip Browser
(Included in Dxx30-PS)
COLOR DWG FOR DATASHEET B+W DWG FOR MANUAL
D830
8GHz
Differential
Amplifier
D1030
10GHz
Differential
Amplifier
D1330
13GHz
Differential
Amplifier
D830
8GHz
Differential
Amplifier
D1030
10GHz
Differential
Amplifier
D1330
13GHz
Differential
Amplifier
Teledyne LeCroy
8 GHz - 13 GHz
Differential Probe
Model Numbers:
D830-PS
D1030-PS
D1330-PS
19
8 GHz - 13 GHz DIFFERENTIAL PROBES 8 GHz - 13 GHz DIFFERENTIAL PROBES
D830, D830-PS D1030, D1030-PS D1330, D1330-PS
Bandwidth Dxx30-SI, Dxx30-SMA-SMP, and
Dxx30-PT Tips
8 GHz (probe only, guaranteed)
8 GHz (system bandwidth,
when used with 808Zi/Zi-A, typical)
Dxx30-SP Tip
3 GHz (probe only, guaranteed)
3 GHz (system bandwidth,
when used with 808Zi/Zi-A, typical)
Dxx30-SI, Dxx30-SMA-SMP, and
Dxx30-PT Tips
10 GHz (probe only, guaranteed)
10 GHz (system bandwidth,
when used with 813Zi/Zi-A, typical)
Dxx30-SP Tip
3 GHz (probe only, guaranteed)
3 GHz (system bandwidth,
when used with 813Zi/Zi-A, typical)
Dxx30-SI and Dxx30-SMA-SMP Tips
13 GHz (probe only, guaranteed)
13 GHz (system bandwidth,
when used with 813Zi/Zi-A, typical)
Dxx30-PT Tip
10 GHz (probe only, guaranteed)
10 GHz (system bandwidth,
when used with 813Zi/Zi-A, typical)
Dxx30-SP Tip
3 GHz (probe only, guaranteed)
3 GHz (system bandwidth,
when used with 813Zi/Zi-A, typical)
Rise Time (10–90%) Dxx30-SI, Dxx30-SMA-SMP, and
Dxx30-PT Tips
50 ps (typical)
System rise time measured
with 8 GHz oscilloscope
Dxx30-SP Tip
132 ps (typical)
System rise time measured
with 8 GHz oscilloscope
Dxx30-SI, Dxx30-SMA-SMP, and
Dxx30-PT Tips
40 ps (typical)
System rise time measured
with 13 GHz oscilloscope
Dxx30-SP Tip
132 ps (typical)
System rise time measured
with 13 GHz oscilloscope
Dxx30-SI and Dxx30-SMA-SMP Tips
35 ps (typical)
System rise time measured
with 13 GHz oscilloscope
Dxx30-PT Tip
40 ps (typical)
System rise time measured
with 13 GHz oscilloscope
Dxx30-SP Tip
132 ps (typical)
System rise time measured
with 13 GHz oscilloscope
Rise Time (20–80%) Dxx30-SI, Dxx30-SMA-SMP, and
Dxx30-PT Tips
37.5 ps (typical)
System rise time measured
with 8 GHz oscilloscope
Dxx30-SP Tip
100 ps (typical)
System rise time measured
with 8 GHz oscilloscope
Dxx30-SI, Dxx30-SMA-SMP, and
Dxx30-PT Tips
30 ps (typical)
System rise time measured
with 13 GHz oscilloscope
Dxx30-SP Tip
100 ps (typical)
System rise time measured
with 13 GHz oscilloscope
Dxx30-SI and Dxx30-SMA-SMP Tips
26 ps (typical)
System rise time measured
with 13 GHz oscilloscope
Dxx30-PT Tip
30 ps (typical)
System rise time measured
with 13 GHz oscilloscope
Dxx30-SP Tip
100 ps (typical)
System rise time measured
with 13 GHz oscilloscope
Noise (Probe) <48 nV/Hz (4.3 mVrms) (typical)
Referred to input, 8 GHz bandwidth.
<48 nV/Hz (4.8 mVrms) (typical)
Referred to input, 10 GHz bandwidth.
<48 nV/Hz (5.5 mVrms) (typical)
Referred to input, 13 GHz bandwidth.
Noise (System) <52 nV/Hz (4.6 mVrms) (typical)
Referred to input, 8 GHz bandwidth.
<52 nV/Hz (5.2 mVrms) (typical)
Referred to input, 10 GHz bandwidth.
<52nV/Hz (5.9 mVrms) (typical)
Referred to input, 13 GHz bandwidth.
Input
Input Dynamic Range 3.5Vpk-pk, ±1.75V (nominal)
Input Common Mode Voltage Range ±5 V (nominal)
Input Offset Voltage Range ±4 V Differential (nominal)
Non-destructive Input Range ±15 V (nominal)
Attenuation 3.75x (nominal)
DC Input Resistance (Nominal) 200 kΩ Differential
50 kΩ Common mode
Impedance (Zmin, Typical) >250 Ω Differential through entire frequency range using SI tip
Impedance (Mid-Band, Typical) Dxx30-SI Lead
470 Ω at 4 GHz, 320 Ω at 6 GHz, 260 Ω at 8 GHz, 250 Ω at 9 GHz, 260 Ω at 10 GHz, 350 Ω at 13 GHz
Dxx30-PT Tip
155 Ω at 4 GHz, 210 Ω at 6 GHz, 140 Ω at 8 GHz, 80 Ω at 9 GHz, 40 Ω at 10 GHz
Product Description Product Code
Complete Probe Systems
8 GHz Complete Probe System with Dxx30-SI Solder-In Tip (Qty.
2), Dxx30-SP Square Pin (Qty. 1), and
Dxx30-PT-KIT Positioner Tip Browser (Qty. 1)
D830-PS
10 GHz Complete Probe System with Dxx30-SI Solder-In Tip (Qty.
2), Dxx30-SP Square Pin (Qty. 1), and
Dxx30-PT-KIT Positioner Tip Browser (Qty. 1)
D1030-PS
13 GHz Complete Probe System with Dxx30-SI Solder-In Tip (Qty.
2), Dxx30-SP Square Pin (Qty. 1), and
Dxx30-PT-KIT Positioner Tip Browser (Qty. 1)
D1330-PS
Amplier and Probe Tip Modules
WaveLink D830 8 GHz/3.5Vp-p Differential Probe
Amplier with Dxx30-SI Solder-In Tip (Qty. 2) and
Dxx30-SP Square Pin (Qty. 1)
D830
WaveLink D1030 10 GHz/3.5Vp-p Differential Probe
Amplier with Dxx30-SI Solder-In Tip (Qty. 2) and
Dxx30-SP Square Pin (Qty. 1)
D1030
WaveLink D1330 13 GHz/3.5Vp-p Differential Probe
Amplier with Dxx30-SI Solder-In Tip (Qty. 2) and
Dxx30-SP Square Pin (Qty. 1)
D1330
Product Description Product Code
Positioner Tip (Browser) Kits
WaveLink Dxx30-PT (up to 10 GHz rating) Adjustable
Positioner Tip Kit. For use with Dxx30 ampliers.
Dxx30-PT-KIT
Probe Platform/Cable Assemblies and Adapters
WaveLink ProLink Platform/Cable Assembly Kit with
complete soft carrying case for all probe items.
WL-PLINK-CASE
SMA/SMP Lead Set
Lead set consisting of WaveLink
Dxx30-SMA-SMP-LEADS for use
with Dxx30 ampliers.
Dxx30-SMA-SMP-LEADS
Accessories
Cascade Microtech EZ-Probe Positioner EZ PROBE
Probe Deskew and Calibration Test Fixture TF-DSQ
Calibration Options
NIST Calibration for D830. Includes test data. D830-CCNIST
NIST Calibration for D1030. Includes test data. D1030-CCNIST
NIST Calibration for D1330. Includes test data. D1330-CCNIST
20
13 GHz - 25 GHz DIFFERENTIAL PROBES
Features & Benets
Up to 25 GHz bandwidth (probe + oscilloscope)
System rise time as fast as 13 ps (20–80%)
25 GHz Solder-in solution
22 GHz ultra-compact browser tip
Superior probe impedance minimizes AC loading on device under
test (DUT)
Carbon-composite browser tips optimize signal fidelity and minimize loading
Probe noise as low as 14 nV/Hz (1.6 mVrms)
Low probe attenuation
Large operating voltage range
±4 V common mode range
±2.5 V offset range
2.0 Vpk-pk dynamic range
Long length Solder-In tip with field replaceable resistors
Ultra-wideband Architecture for Superior Signal Fidelity
Teledyne LeCroy’s WaveLink® high bandwidth differential probes utilize advanced
differential traveling wave (distributed) amplier architecture to achieve superior
high frequency true analog broadband performance. Traveling wave (distributed)
ampliers are commonly used in ultra high frequency broadband ampliers. This
multi-stage amplier architecture maximizes gain per stage and minimizes probe
attenuation, which provides very low probe noise and fast rise times.
LabMaster 10 Zi
LabMaster 9 Zi-A
WaveMaster 8 Zi/Zi-A
SDA11000
SDA13000
SDA18000 WL-PLINK-A
Platform/Cable
Assembly:
(
included in
D1x05-A-P
S
)
WL-2.92MM
Platform/Cable
Assembly
(
included in
D2x05-A-P
Dxx05-SI
Solder-In Lead
Dxx05-PT
Positioner Tip
Browser
LPA-2.92
LPA 2.92 to ProLink Adapter:
D1305-A
13 GHz
D1605-A
16 GHz
D2005-A
20 GHz
D2505-A
25 GHz Differential Amplifier
Teledyne LeCroy
13 GHz - 25 GHz
Differential Probe
Model Numbers:
D1305-A-PS
D1605-A-PS
D2005-A-PS
D2505-A-PS
21
13 GHz - 25 GHz DIFFERENTIAL PROBES
LabMaster 10 Zi
LabMaster 9 Zi-A
WaveMaster 8 Zi/Zi-A
SDA11000
SDA13000
SDA18000 WL-PLINK-A
Platform/Cable
Assembly:
(
included in
D1x05-A-P
S
)
WL-2.92MM
Platform/Cable
Assembly
(
included in
D2x05-A-P
S)
Dxx05-SI
Solder-In Lead
Dxx05-PT
Positioner Tip
Browser
LPA-2.92
LPA 2.92 to ProLink Adapter:
D1305-A
13 GHz
D1605-A
16 GHz
D2005-A
20 GHz
D2505-A
25 GHz Differential Amplifier
D1305-A, D1305-A-PS D1605-A, D1605-A-PS D2005-A, D2005-A-PS D2505-A, D2505-A-PS
Bandwidth Dxx05-SI and Dxx05-PT Tips
13 GHz (probe only, guaranteed)
13 GHz (system bandwidth,
when used with 813Zi, typical)
Dxx05-SI and Dxx05-PT Tips
16 GHz (probe only, guaranteed)
16 GHz (system bandwidth,
when used with 816Zi, typical)
Dxx05-SI and Dxx05-PT Tips
20 GHz (probe only, guaranteed)
20 GHz (system bandwidth,
when used with 820Zi, typical)
Dxx05-SI Lead
25 GHz (probe only, guaranteed)
25 GHz (system bandwidth,
when used with 825Zi, typical)
Dxx05-PT Tip
22 GHz (system bandwidth,
when used with 825Zi, typical)
20 GHz (probe only, guaranteed)
Rise Time (10–90%) Dxx05-SI and Dxx05-PT Tips
32.5 ps (typical)
System rise time measured
with 13 GHz oscilloscope)
Dxx05-SI and Dxx05-PT Tips
28 ps (typical)
System rise time, measured
with 16 GHz oscilloscope
Dxx05-SI and Dxx05-PT Tips
20 ps (typical)
System rise time measured
with 20 GHz oscilloscope
Dxx05-SI Lead
17.5 ps (typical)
System rise time measured with
25 GHz oscilloscope
Dxx05-PT Tip
19 ps (typical)
System rise time measured with
25 GHz oscilloscope
Rise Time (20–80%) Dxx05-SI and Dxx05-PT Tips
24.5 ps (typical)
System rise time measured
with13 GHz oscilloscope
Dxx05-SI and Dxx05-PT Tips
21 ps (typical)
System rise time measured
with 16 GHz oscilloscope
Dxx05-SI and Dxx05-PT Tips
15 ps (typical)
System rise time measured
with 20 GHz oscilloscope
Dxx05-SI Lead
13 ps (typical)
System rise time measured with
25 GHz oscilloscope
Dxx05-PT Tip
14 ps (typical)
System rise time measured with
25 GHz oscilloscope
Noise (Probe) < 14 nV/Hz (1.6 mVrms)
(typical)
Referred to input,
13 GHz bandwidth
< 14 nV/Hz (1.8 mVrms)
(typical)
Referred to input,
16 GHz bandwidth
< 18 nV/Hz (2.5 mVrms)
(typical)
Referred to input,
20 GHz bandwidth
< 18 nV/Hz (2.8 mVrms)
(typical)
Referred to input,
25 GHz bandwidth
Noise (System) < 23 nV/Hz (2.7 mVrms)
(typical) Referred to input,
13 GHz bandwidth
< 23 nV/Hz (2.9 mVrms)
(typical) Referred to input,
16 GHz bandwidth
< 28 nV/Hz (4.0 mVrms)
(typical) Referred to input,
20 GHz bandwidth
< 28 nV/Hz (4.5 mVrms)
(typical) Referred to input,
25 GHz bandwidth
Input
Input Dynamic Range 2.0 Vpk-pk, (±1.0 V) (nominal)
Input Common Mode Voltage Range ±4 V (nominal)
Input Offset Voltage Range ±2.5 V Differential (nominal)
Non-destructive Input Range ±10 V (nominal)
Attenuation 3.5x (nominal) 4.5x (nominal)
DC Input Resistance (Nominal) 1.1 kΩ Differential
100 kΩ Common mode
Impedance (Zmin, typical) Dxx05-SI Lead
> 300 Ω Differential through
entire frequency range
Dxx05-PT Tip
>160 Ω Differential through
entire frequency range
Dxx05-SI Lead
> 300 Ω Differential through
entire frequency range
Dxx05-PT Tip
>160 Ω Differential through
entire frequency range
Dxx05-SI Lead
> 230 Ω Differential through
entire frequency range
Dxx05-PT Tip
>160 Ω Differential through
entire frequency range
Dxx05-SI Lead
> 120 Ω Differential through
entire frequency range
Dxx05-PT Tip
>160 Ω Differential through
entire frequency range
Impedance (mid-band, typical) Dxx05-SI Lead: 300 Ω at 6 GHz, 525 Ω at 13 GHz, 600 Ω at 16 GHz, 300 Ω at 20 GHz, 120 Ω at 25 GHz
Dxx05-PT Tip: 160 Ω at 6 GHz, 450 Ω at 13 GHz, 240 Ω at 16 GHz, 210 Ω at 20 GHz
Product Description Product Code
Complete Probe Systems
13 GHz Complete Probe System with Solder-In Tip
(13 GHz) and Positioner Tip Browser (13 GHz)
D1305-A-PS
16 GHz Complete Probe System with Solder-In Tip
(16 GHz) and Positioner Tip Browser (16 GHz)
D1605-A-PS
20 GHz Complete Probe System with Solder-In Tip
(20 GHz) and Positioner Tip Browser (20 GHz)
D2005-A-PS
25 GHz Complete Probe System with Solder-In Tip
(25 GHz) and Positioner Tip Browser (22 GHz)
D2505-A-PS
Amplier and Probe Tip Modules
WaveLink D1305 13 GHz/1.6 Vpk-pk Differential Probe
Amplier with Dxx05-SI Solder-In Tip (Qty. 2)
D1305-A
WaveLink D1605 16 GHz/1.6 Vpk-pk Differential Probe
Amplier with Dxx05-SI Solder-In Tip (Qty. 2)
D1605-A
WaveLink D2005 20 GHz/1.6 Vpk-pk Differential Probe
Amplier with Dxx05-SI Solder-In Tip (Qty. 2)
D2005-A
WaveLink D2505 25 GHz/1.6 Vpk-p Differential Probe
Amplier with Dxx05-SI Solder-In Tip (Qty. 2)
D2505-A
Positioner Tip (Browser) Kits
WaveLink Dxx05-PT (Up to 22 GHz Rating) Adjustable
Positioner Tip Kit. For use with Dxx05 Ampliers
Dxx05-PT-KIT
Probe Platform/Cable Assemblies and Adapters
WaveLink ProLink Platform/Cable Assembly Kit
for 13 GHz WaveLink Probes
WL-PLINK-A-CASE
WaveLink 2.92 mm Platform/Cable Assembly Kit
for 20 GHz WaveLink Probes
WL-2.92MM-CASE
ProLink to 2.92 mm Adapter with Probe Power
and Communication Pass Through
LPA-2.92
Product Description Product Code
Accessories
Cascade Microtech EZ-Probe Positioner EZ PROBE
Probe Deskew and Calibration Test Fixture TF-DSQ
Calibration Options
NIST Calibration for D1305. Includes Test Data D1305-A-CCNIST
NIST Calibration for D1605. Includes Test Data D1605-A-CCNIST
NIST Calibration for D2005. Includes Test Data D2005-A-CCNIST
NIST Calibration for D2505. Includes Test Data D2505-A-CCNIST
Replacement Parts
Replacement Dxx05-SI 13–25 GHz Solder-In Lead with
Qty. 5 Spare Resistors
Dxx05-SI
Replacement SI Resistor Kit for Dxx05-SI Solder-In Tip Dxx05-SI-RESISTORS
Replacement Dxx05-PT Positioner Tip Dxx05-PT
Qty. 4 Replacement Carbon Composite Pogo-pin Tips Dxx05-PT-TIPS
Replacement Probe Tip Holder Kit PK600ST-3
Replacement Platform/Cable Assembly Mounting Kit PK600ST-4
Qty. 1 Package of Black Adhesive Pads (10/pkg.) and
Qty. 1 Package of White Adhesive Pads (10/pkg.)
Dxx0-PT-TAPE
Qty. 1 Package of Adhesive Probe Connection Guides (200
individual guides/package)
Dxx05-PT-GUIDES
22
HIGH VOLTAGE DIFFERENTIAL PROBES
23
HIGH VOLTAGE DIFFERENTIAL PROBES
Differential active probes are like two probes in one. Instead of measuring
a test point in relation to a ground point (like single-ended active probes),
differential probes measure the difference in voltage of a test point in
relation to another test point.
Opposite page:
HVD3000 Series High Voltage Differential Probes
working with an HDO8000
Teledyne LeCroy
High Voltage
Differential Probe
Model Numbers:
HVD3102
HVD3106
HVD3106-6M
HVD3206
HVD3605
AP031
ADP300
ADP305
24
Teledyne LeCroy
High Voltage
Differential Probe
Model Numbers:
HVD3102
HVD3106
HVD3106-6M
HVD3206
HVD3605
HIGH VOLTAGE DIFFERENTIAL PROBES
The HVD3000 series high voltage differential probes provide high CMRR over a
broad frequency range to simplify the measurement challenges found in noisy, high
common-mode power electronics environments. The probe’s design is easy-to-use
and enables safe, precise high voltage floating measurements.
Key Features
1 kV, 2 kV, 6 kV CAT safety rated models
World’s only 1500 Vdc safety rated probe per IEC/EN 61010-031:2015
Widest differential voltage ranges available
Exceptional common-mode rejection ratio (CMRR) across a
broad frequency range
1% gain accuracy
High offset capability at both high and low attenuation
AC and DC coupling
ProBus active probe interface with automatic scaling
Auto-zero capabilities
Wide oscilloscope compatibility
25
HIGH VOLTAGE DIFFERENTIAL PROBES
Ordering Information
Product Description Product Code
1 kV, 25 MHz High Voltage Differential Probe with 2 m cable HVD3102
1 kV, 120 MHz High Voltage Differential Probe with 2 m cable HVD3106
1 kV, 80 MHz High Voltage Differential Probe with 6m cable HVD3106-6M
1 kV, 25 MHz High Voltage Differential Probe with 2 m cable without tip Accessories HVD3102-NOACC
1 kV, 120 MHz High Voltage Differential Probe with 2 m cable without tip Accessories HVD3106-NOACC
2 kV, 120 MHz High Voltage Differential Probe with 2 m cable HVD3206
6 kV, 100 MHz High Voltage Differential Probe with 6 m cable HVD3605
High Voltage Replacement Accessories Kit (Includes 2 each, 1 Black, 1 Red):
Safety Alligator Clips, Plunger Pincer Clips, Plunger Hook Clips, Plunger Alligator Clips, Spade Terminals PK-HV-001
HVD3102 HVD3102-NOACC HVD3106 HVD3106-NOACC HVD3106-6M HVD3206 HVD3605
Bandwidth 25 MHz 25 MHz 120 MHz 120 MHz 80 MHz 120 MHz 100 MHz
Differential
Voltage
Range
1500 V
(DC + peak AC)
(2000V maximum
typical measurable
before saturation)
1500 V
(DC + peak AC)
(2000V maximum
typical measurable
before saturation
1500 V
(DC + peak AC)
(2000V maximum
typical measurable
before saturation)
1500 V
(DC + peak AC)
(2000V maximum
typical measurable
before saturation)
1500 V
(DC + peak AC)
(2000V maximum
typical measurable
before saturation)
2000 V
(DC + peak AC)
7000 V
(DC + peak AC)
(7600 V maximum
typical measurable
before saturation)
Max Safe
Input
Voltage
1000 Vrms CAT III 1000 Vrms CAT III 1000 Vrms CAT III 1000 Vrms CAT III 1000 Vrms CAT III 1000 Vrms
CAT III
1500 Vdc CAT III
2000 V
(DC + peak AC )
CAT I
8485 V
(DC + peak AC)
CAT I
6000 Vrms CAT I
1000 Vrms CAT III
1500 Vdc CAT III
Gain
Accuracy
1% 1% 1% 1% 1% 1% 1%
Cable Length 2 meters 2 meters 2 meters 2 meters 6 meters 2 meters 6 meters
Included Tip
Accessories
Yes No Yes No Yes Yes Yes
PK-HVA-05
Spade Terminals
(Red/Black)
1000 V CAT III
PK-HVA-01
Safety Alligator
Clips (Red/Black)
1000 V CAT III
PK-HVA-04
Plunger Alligator
Clips (Red/Black)
1000 V CAT III
PK-HVA-03
Plunger Hook
Clips (Red/Black)
1000 V CAT II
PK-HVA-02
Plunger Pincer
Clips (Red/Black)
1000 V CAT II
HVD310X/3106-6M
High Voltage
Differential Probe
PK-HVA-06
6 KV Safety Alligator
Clips (Red/Black)
6000 V CAT I
(Optional)
PK-HVA-05
Spade Terminals
(Red/Black)
1000 V CAT III
(Optional)
PK-HVA-01
Safety Alligator
Clips (Red/Black)
1000 V CAT III
(Optional)
PK-HVA-04
Plunger Alligator
Clips (Red/Black)
1000 V CAT III
(Optional)
PK-HVA-03
Plunger Hook
Clips (Red/Black)
1000 V CAT II
(Optional)
PK-HVA-02
Plunger Pincer
Clips (Red/Black)
1000 V CAT II
(Optional)
HVD3206/3605
High Voltage
Differential Probe
PK-HVA-06
6 KV Safety Alligator
Clips (Red/Black)
6000 V CAT I
PK-HVA-05
Spade Terminals
(Red/Black)
1000 V CAT III
(Optional)
PK-HVA-01
Safety Alligator
Clips (Red/Black)
1000 V CAT III
(Optional)
PK-HVA-04
Plunger Alligator
Clips (Red/Black)
1000 V CAT III
(Optional)
PK-HVA-03
Plunger Hook
Clips (Red/Black)
1000 V CAT II
(Optional)
PK-HVA-02
Plunger Pincer
Clips (Red/Black)
1000 V CAT II
(Optional)
HVD310X-NOACC
High Voltage
Differential Probe
PK-HVA-06
6 KV Safety Alligator
Clips (Red/Black)
6000 V CAT I
(Optional)
PK-HVA-05
Spade Terminals
(Red/Black)
1000 V CAT III
PK-HVA-01
Safety Alligator
Clips (Red/Black)
1000 V CAT III
PK-HVA-04
Plunger Alligator
Clips (Red/Black)
1000 V CAT III
PK-HVA-03
Plunger Hook
Clips (Red/Black)
1000 V CAT II
PK-HVA-02
Plunger Pincer
Clips (Red/Black)
1000 V CAT II
HVD310X/3106-6M
High Voltage
Differential Probe
PK-HVA-06
6 KV Safety Alligator
Clips (Red/Black)
6000 V CAT I
(Optional)
PK-HVA-05
Spade Terminals
(Red/Black)
1000 V CAT III
(Optional)
PK-HVA-01
Safety Alligator
Clips (Red/Black)
1000 V CAT III
(Optional)
PK-HVA-04
Plunger Alligator
Clips (Red/Black)
1000 V CAT III
(Optional)
PK-HVA-03
Plunger Hook
Clips (Red/Black)
1000 V CAT II
(Optional)
PK-HVA-02
Plunger Pincer
Clips (Red/Black)
1000 V CAT II
(Optional)
HVD3206/3605
High Voltage
Differential Probe
PK-HVA-06
6 KV Safety Alligator
Clips (Red/Black)
6000 V CAT I
PK-HVA-05
Spade Terminals
(Red/Black)
1000 V CAT III
(Optional)
PK-HVA-01
Safety Alligator
Clips (Red/Black)
1000 V CAT III
(Optional)
PK-HVA-04
Plunger Alligator
Clips (Red/Black)
1000 V CAT III
(Optional)
PK-HVA-03
Plunger Hook
Clips (Red/Black)
1000 V CAT II
(Optional)
PK-HVA-02
Plunger Pincer
Clips (Red/Black)
1000 V CAT II
(Optional)
HVD310X-NOACC
High Voltage
Differential Probe
PK-HVA-06
6 KV Safety Alligator
Clips (Red/Black)
6000 V CAT I
(Optional)
PK-HVA-05
Spade Terminals
(Red/Black)
1000 V CAT III
PK-HVA-01
Safety Alligator
Clips (Red/Black)
1000 V CAT III
PK-HVA-04
Plunger Alligator
Clips (Red/Black)
1000 V CAT III
PK-HVA-03
Plunger Hook
Clips (Red/Black)
1000 V CAT II
PK-HVA-02
Plunger Pincer
Clips (Red/Black)
1000 V CAT II
HVD310X/3106-6M
High Voltage
Differential Probe
PK-HVA-06
6 KV Safety Alligator
Clips (Red/Black)
6000 V CAT I
(Optional)
PK-HVA-05
Spade Terminals
(Red/Black)
1000 V CAT III
(Optional)
PK-HVA-01
Safety Alligator
Clips (Red/Black)
1000 V CAT III
(Optional)
PK-HVA-04
Plunger Alligator
Clips (Red/Black)
1000 V CAT III
(Optional)
PK-HVA-03
Plunger Hook
Clips (Red/Black)
1000 V CAT II
(Optional)
PK-HVA-02
Plunger Pincer
Clips (Red/Black)
1000 V CAT II
(Optional)
HVD3206/3605
High Voltage
Differential Probe
PK-HVA-06
6 KV Safety Alligator
Clips (Red/Black)
6000 V CAT I
PK-HVA-05
Spade Terminals
(Red/Black)
1000 V CAT III
(Optional)
PK-HVA-01
Safety Alligator
Clips (Red/Black)
1000 V CAT III
(Optional)
PK-HVA-04
Plunger Alligator
Clips (Red/Black)
1000 V CAT III
(Optional)
PK-HVA-03
Plunger Hook
Clips (Red/Black)
1000 V CAT II
(Optional)
PK-HVA-02
Plunger Pincer
Clips (Red/Black)
1000 V CAT II
(Optional)
HVD310X-NOACC
High Voltage
Differential Probe
PK-HVA-06
6 KV Safety Alligator
Clips (Red/Black)
6000 V CAT I
(Optional)
26
HIGH VOLTAGE DIFFERENTIAL PROBES
The AP031 is a low cost, battery operated active differential probe intended
for measuring higher voltages. The differential techniques employed permit
measurements to be taken at two points in a circuit without reference to the
ground, allowing the oscilloscope to be safely grounded without the use of
opto-isolators or isolating transformers.
Features
Safe floating measurements
15 MHz bandwidth
700 V maximum input voltage
Works with any 1 MΩ input oscilloscope
Specications
Attenuation ÷10 / ÷100
Bandwidth 15 MHz
Input R 4 MΩ
Differential Mode Range ±70 V / ±700 V DC + Peak AC
Common Mode Range ±700 V DC + Peak AC
CMRR 86 dB @ 50 Hz
56 dB @ 200 kHz
Power Requirements: four AA batteries
Ordering Information
Product Description Product Code
700 V, 15 MHz Differential Probe (÷10, ÷100) AP031
1,400 V, 20 MHz High-Voltage Differential Probe AP300
1,400 V, 100 MHz High-Voltage Differential Probe AP305
Teledyne LeCroy
High Voltage
Differential Probe
Model Numbers:
AP031
ADP300
ADP305
AP031
27
HIGH VOLTAGE DIFFERENTIAL PROBES
ADP30X high-voltage active probes are safe, easy-to-use, and
ideally suited for measuring power electronics. The ADP300
is designed for troubleshooting low-frequency power devices
and other circuits where the reference potential is elevated
from the ground or the location of the ground is unknown.
The ADP305 is designed for measuring the high-speed
floating voltages found in todays power electronics.
Features
20 MHz and 100 MHz bandwidth
1,000 Vrms common mode voltage
1,400 Vpeak differential voltage
Specications
Electrical Characteristics
Bandwidth 20 MHz (ADP300)
100 MHz (ADP305)
Differential Voltage 1,400 V peak
Common Mode Voltage 1,000 V rms CAT III
Low-Frequency Accuracy (Probe Only) 1% of Reading
CMRR 50/60 Hz 80 dB (10,000:1)
100 kHz 50 dB (300:1)
Max. Slew Rate (Referenced to Input) 60,000 V/µs (ADP300)
300,000 V/µs (ADP305)
AC Noise (Referenced to Input) 50 mV rms
Attenuation ÷100/÷1000 (automatically selected by scope)
Input Impedance Between inputs 8 MΩ, 6 pF
Each input to ground 4 MΩ, 1 pF
Sensitivity 1 V/div to 350 V/div (ADP300)
200 mV/div to 350 V/div (ADP305)
Interface ProBus, 1 MΩ*
General Characteristics
Overall Length 2 m
Input Connectors 4 mm Shrouded Banana Plug
Operating Temperature 0 ˚C to 50 ˚C
Warranty 1 year
*Requires AP-1M for oscilloscopes with 50 Ω only inputs
EN 61010 CAT III
80 dB CMRR at 50/60 Hz
ProBus system
Full remote control
ADP30X
28
DIFFERENTIAL AMPLIFIERS
28
29
Opposite page:
DA1855A Differential Amplier working with the
HDO6000 oscilloscope for power measurement.
DIFFERENTIAL AMPLIFIERS
Differential ampliers are intended to act as signal conditioning preampliers
for oscilloscopes and network and spectrum analyzers, providing differential
measurement capability to instruments having only a single-ended input. The
“-PR2” version of each amplier is a dual channel unit. The DXC series
differential input cables are matched to the characteristics of the amplier.
Teledyne LeCroy
Differential Amplier
and Accessory
Model Numbers:
DA1855A
DA1855-PR2
DA1855A-RM
DA1855A-PR2-RM
DXC5100
DXC100A
DXC200
DA101
30
DIFFERENTIAL AMPLIFIERS
The DA1855A is a stand-alone, high-
performance 100 MHz differential
amplier. It is intended to act as a
signal conditioning preamplier for
oscilloscopes, digitizers and spectrum
analyzers, providing differential
measurement capability to instruments
having only a single-ended input. When
used with a DA1855A, oscilloscopes
can obtain Common Mode Rejection
Ratio (CMRR) and overdrive recovery
performance levels previously
unobtainable.
Amplier gain can be set to 1 or
10 A built-in input attenuator can be
separately set to attenuate signals by
a factor of 10, providing gains of 10,
1, or 0.1 and common mode dynamic
range of ±15.5 V (÷1) or ±155 V (÷10).
Optional probes increase the maximum
input signal and common mode ranges
in proportion to their attenuation ratio
but do not exceed their maximum input
voltage rating. Effective gain of the
DA1855A, including probe attenuation,
amplier gain and attenuator settings, is
automatically displayed.
The DA1855A features a built-in
Precision Voltage Generator (PVG) that
can be set to any voltage between
±15.5 V (±10 V in Differential Offset)
with up to 100 µV resolution. The PVG’s
output can be selected as an input to
the inverting (-) input of the amplier for
operation as a differential comparator,
or applied internally as a true
differential offset voltage independent
of oscilloscope offset. The differential
amplier is also available in a 2 channel
model. In addition, a rackmount is
available for each model for easy
installation with other instruments.
Teledyne LeCroy
Differential Amplier
and Accessory
Model Numbers:
DA1855A
DA1855-PR2
DA1855A-RM
DA1855A-PR2-RM
DXC5100
DXC100A
DXC200
DA101
DA1855A
31
DIFFERENTIAL AMPLIFIERS
Ordering Information
Product Description Product Code
1 Ch, 100 MHz Differential Amplier with Precision Voltage Source DA1855A
2 Ch,100 MHz Differential Amplier with Precision Voltage Source DA1855A-PR2
DA1855A with Rackmount DA1855A-RM
DA1855A with Rackmount (must be ordered at time of purchase, no retrot) DA1855A-PR2-RM
÷100 or ÷10 Selectable, 250 MHz Passive Differential Probe Pair DXC100A*
÷1, 50 MHz Passive Differential Probe Pair DXC200*
÷100, 250 MHz 2.5 kV, High Voltage Probe Pair (requires DA101 for full performance) DXC-5100*
÷10 1 MΩ Passive Attenuator for DXC Series Probes DA101*
*Must be used with DA Series Differential Ampliers
DXC100A
÷100 or ÷10 Selectable, 250 MHz Passive Differential Probe Pair
DC to 100 MHz Bandwidth with DA1855A
DC to 10 MHz Bandwidth with DA1822
Max Input Voltage 500 V
Selectable 10 or 100 Attenuation Factor
1.2 m Cable Length
DXC5100
÷100, 2.5KV Passive High Voltage Probe Pair. Requires DA101 for full performance
DXC200
÷1, 50 MHz, Passive Differential Probe Pair
DC to 50 MHz with DA1855A
DC to 10 MHz with DA1822A
Max Input Voltage 500 V (Limited to Amplier Max Input Voltage)
x1 Differential Probe Pair
0.7 m Cable Length
DA101
÷10, 1MΩ Passive Attenuator for DXC series probes
32
HIGH VOLTAGE PROBES
32
33
HIGH VOLTAGE PROBES
High voltage probes are suitable for a wide range of applications where
high-voltage measurements must be made safely and accurately. There
are several xed attenuation probes covering a range from 1 kV to 6 kV
and varying transient overvoltage ratings. All of these high voltage probes
feature a spring loaded probe tip and a variety of standard accessories
to make probing high voltages safe and easy. Additionally, all of the high
voltage probe have a probe sense pin to automatically congure the
oscilloscope for use with the probe.
Opposite page:
PPE Series High Voltage Probe
Teledyne LeCroy
High Voltage Probe
Model Numbers:
HVP120
PPE1.2KV
PPE2KV
PPE4KV
PPE5KV
PPE6KV
34
HIGH VOLTAGE PROBES
Teledyne LeCroy
High Voltage Probe
Model Number:
HVP120
Electrical Characteristics
Bandwidth 400 MHz
Risetime (10% - 90%) 900 ps (typical)
Maximum Input Voltage*
Measurement Category II 1000 Vrms
Measurement Category I 4000V Transient Overvoltage at 1000 Vrms
6000V Transient Overvoltage at 0 Vrms
Pollution Degree* 2
Input Capacitance 7.5 pF (typical)
Compensation Range 10 pF - 50 pF (typical)
Attenuation Ratio 100:1 ± 2%
Environmental
Temperature (Operating) 0°C to 50°C
Temperature (Non-Operating) -40°C to 71°C
Humidity (Operating) 80% RH (Non-Condensing) up to 31°C,
decreasing linearly to 40% RH at 50°C
Altitude (Operating) up to 2,000 m
Altitude (Non-Operating) up to 15,000 m
General Characteristics
Weight (probe) 67 g (0.15 lbs)
Cable Length 2 m (6.56 ft)
Probe Tip Diameter 5 mm (0.20 inches)
* As dened in IEC 61010-031
The HVP120 is a high voltage passive probe designed for probing up to
1,000 Vrms and capable of handling up to 6,000 V peak transients. Its
fast rise time and excellent frequency response make it suitable for a wide
variety of high voltage measurement applications. The HVP120 features
a spring loaded probe tip and a variety of standard accessories to make
probing high voltages safe and easy.
Features
400 MHz probe bandwidth
900 ps rise time
1000 Vrms maximum input
Up to 6 kV transient overvoltage
35
HIGH VOLTAGE PROBES
Typical Voltage Derating HVP120
Measurement Category I
0
200
400
600
800
1000
1200
100K 1M 10M100M1G
Frequency [Hz]
Amplitude AC rms [V]sinus
HVP120
RMS vs. Peak Pulse Voltage
Measurement Category I
0
1000
2000
3000
4000
5000
6000
7000
8000
0200 400600 80
01
000
AC rms or DC [V]
Peak Pulse [V]
Product Description Product Code
400 MHz, High Voltage Passive Probe HVP120
High Voltage Replacement Accessories Kit PK-HV-002
Replacement Accessories
One of each of the following accessories are included with the HVP120. Replacement quantities are listed below.
Coding Rings (set) 4 Colors (Qty 3 also included standard) PK1-5MM-106
Ground Lead 22 cm to 4 mm Banana plug (Qty 1) PK1-5MM-122
Solid Tip 0.8 mm (Qty 5) PK1-5MM-125
Spring Tip 0.8 mm (Qty 5) PK1-5MM-126
BNC Adapter 5.0-L (Qty 1) PK1-5MM-127
Insulating Cap 5.0-L (Qty 1) PK1-5MM-128
Protection Cap 5.0-L (Qty 1) PK1-5MM-129
Sprung Hook 5.0-L (Qty 1) PK1-5MM-130
Adjustment Tool T (Qty 1) PK1-5MM-131
Flexible Adapter 5.0-L (Qty 1) PK1-5MM-132
Safety Alligator Clip red (Qty 1) PK1-5MM-133
Ground Lead 22 cm (Qty 1) PK1-5MM-134
36
HIGH VOLTAGE PROBES
The PPE series includes four xed-attenuation probes covering a range from
2 kV to 6 kV, and one switchable probe providing ÷10/÷100 attenuation for
voltage inputs up to 1.2 kV. All xed-attenuation, standard probes automatically
rescale compatible Teledyne LeCroy oscilloscopes for the appropriate attenuation
of the probe.
Features
Safe, accurate high-voltage measurement
1.2 kV to 6 kV
High-Voltage Probes Selection Guide Specications
Types Bandwidth Input R Input C Attenuation Maximum Probe Cable
(MHz) (Ω) (pF) Voltage Encoding
PPE1.2kV* 400 50 M < 6 ÷10 / ÷100 600 V/1.2 kV No 2 m
PPE2kV* 400 50 M < 6 ÷100 2 kV Yes 2 m
PPE4kV* 400 50 M < 6 ÷100 4 kV Yes 2 m
PPE5kV* 400 50 M < 6 ÷100 5 kV Yes 2 m
PPE6kV* 400 50 M < 6 ÷1000 6 kV Yes 2 m
Teledyne LeCroy
High Voltage Probe
Model Numbers:
PPE1.2KV
PPE2KV
PPE4KV
PPE5KV
PPE6KV
37
HIGH VOLTAGE PROBES
Ordering Information
Product Description Product Code
÷10/÷100; 200/300 MHz; 5 MΩ/50 MΩ High-Voltage Probe, 600 V/1.2 kV max. Voltage DC PPE1.2KV
÷100; 400 MHz; 50 MΩ High-Voltage Probe, 2 kV max. Voltage DC and Peak AC PPE2KV
÷100; 400 MHz; 50 MΩ High-Voltage Probe, 4 kV max. Voltage DC and Peak AC PPE4KV
÷100; 400 MHz; 50 MΩ High-Voltage Probe, 5 kV max. Voltage DC and Peak AC PPE5KV
÷1000; 400 MHz; 50 MΩ High-Voltage Probe, 6 kV max. Voltage DC and Peak AC PPE6KV
Accessory Kit for PPE1.2kV, 2kV, 4kV, 5kV, and 6kV PK103
Sprung Hook (red) PK103-1
Ground Lead (22 cm) PP005-GL22
Crocodile Clip PK30x-2
Probe Tip to BNC Adapter PP005-BNC
Spring Tip (0.8 mm) PP005-ST8
Rigid Tip V2A PP005-RT
Supplied with probe:
* Probe Kit: Trimming tool, ground lead, rigid tip, IC insulator, BNC adapter, tip insulator, spring hook, red crocodile clip.
4 mm safety ground lead, and green/yellow crocodile clip.
Sprung Hook
BNC Adapter Insulating Tip IC Insulating Tip Straight Tip
(0.8 mm)
Spring Contact Tip
(0.8 mm)
Trimming Tool
Crocodile Clip (Black) Crocodile Clip (Red)
Ground Lead
(22 cm)
Security Ground Lead
Flexible 4 mm
Security Adapter
38
OPTICAL PROBES
39
OPTICAL PROBES
Teledyne LeCroy’s wide-band multi-mode optical-to-electrical converters
are designed for measuring optical communications signals. Their broad
wavelength range and multi-mode input optics make these devices ideal for
applications including Ethernet, Fibre Channel, and ITU telecom standards.
Available to support optical data rates up to 11.3 Gb/s with reference
receivers, or slightly higher without reference receivers.
These wide- band multi-mode optical-to-electrical converters are designed
for measuring optical communications signals. They connect to Teledyne
LeCroy real-time oscilloscopes and provide capability for physical layer
signal assessment using a variety of oscilloscope tools, such as SDAIII-
CompleteLinQ Serial Data Eye, Jitter, Noise and Crosstalk Analysis, mask
testing, serial triggering and decoding, and other compliance and debug
tools. Maximum data rate test capability is >11.317 Gb/s with reference
receiver, or 12.5 Gb/s without.
Opposite page:
OE455 Optical Probe working with a WaveRunner 640 Zi oscilloscope.
Teledyne LeCroy
Optical Probe
Model Numbers:
OE695G
OE425
OE455
OE525
OE555
40
OPTICAL PROBES
Features
Compatible with Teledyne LeCroy WavePro 7 Zi/Zi-A, WaveMaster 8 Zi/Zi-A,
LabMaster 9 Zi-A, and LabMaster 10 Zi oscilloscopes
Frequency range DC to 9.5 GHz (electrical, -3 dB)
Reference receiver support from 8GFC to 10GFC FEC, or Custom (<12.5Gb/s)
Full bandwidth mode (no reference receiver applied)
62.5/125 µm multi-mode or single-mode ber input
+7 dBm (5 mW) max peak optical power
Low noise (as low as 25 pW/Hz)
Ideal for Eye Mask, Extinction Ratio, and Optical Modulation Amplitude
(OMA) testing
OE695G
Teledyne LeCroys OE695G wide-band optical-to-electrical converter is ideal for
measuring optical datacom and telecom signals with data rates from 622 Mb/s to
12.5+ Gb/s. Connection to a real-time Teledyne LeCroy oscilloscope is through the
2.92mm interface, with a provided adapter to connect to ProLink interfaces.
Optical Wavelength Range 780 to 1550 nm (calibrated range)
750 to 1650 nm (usable range)
Maximum Modulation
Bandwidth
DC to 8.625 GHz (-3 dBe, electrical)
DC to 11.64 GHz (-3 dBo, optical)
(Reference Receiver Applied)
DC to 9.5 GHz (-3 dBe)
DC to 12 GHz (-6 dBe)
DC to 17 GHz (-14 dBe)
(+/-1 dBe passband variations typical, no Reference
Receiver Applied)
Reference Receiver
Uncertainty
±1.6 dBe up to Fref =0.75*bit rate
±4 dBe 2*Fref setting (typical)
±0.85 dBe up to Fref =0.75*bit rate
±4 dBe 2*Fref setting
(on matched oscilloscope input channel 4 with 11, 17,
20, 30, 39, 50, 75, 90, or
100 mV/div gain ranges) with purchase of OE695G-
REFCAL)
Reference Receiver
Settings
8GFC, OC192/STM64,10GBASE-W,10GBASE-R,
10GFC, ITU-T G.975 FEC, ITU-T G.709 FEC, 10GbE FEC,
10GFC FEC, Custom (622 Mb/s to 12.5 Gb/s),
None (Maximum Bandwidth)
Noise Equivalent Power 25 pW/Hz @ 1310 nm (typical)
50 pW/Hz @ 850 nm (typical)
Average noise spectral density 0-10 GHz using most
sensitive vertical scale
Rise Time (10-90%) 33 ps (typical, no reference receiver applied)
Connector Type FC/PC, compatible with 62.5/125 µm Multi-Mode ber,
or mechanically compatible Single-Mode ber
Maximum Optical
Linear Input
(1 dB Compression Point)
-2 dBm (typical), -3 dBm (minimum) at 1550/1310 nm
+4 dBm (typical), +3 dBm (minimum) at 850 nm
Maximum Optical Power +7 dBm (5 mW) Peak
Conversion Gain (typical) 0.17 V/mW (785 nm)
0.21 V/mW (850 nm)
0.33 V/mW (1310 nm)
0.33 V/mW (1550 nm)
Specications
Teledyne LeCroy
Optical Probe
Model Numbers:
OE695G
OE425
OE455
OE525
OE555
41
OPTICAL PROBES
Ordering Information
Product Description Product Code
Optical-to-Electrical Converter, 785 to 1550 nm, 2.92 mm connector with ProLink adapter OE695G
Optical-to-Electrical Converter, 500–870 nm ProBus BNC Connector OE425
Optical-to-Electrical Converter, 950–1630 nm ProBus BNC Connector OE455
Optical-to-Electrical Converter, 500–870 nm ProLink BMA Connector OE525
Optical-to-Electrical Converter, 950–1630 nm ProLink BMA Connector OE555
OE425/OE455/OE525/OE555
The O/E converters contain calibration data that can be used to create optical
reference receivers for SONET/SDH (up to OC48/STM16), Fibre Channel, Gigabit
Ethernet, and other optical standards. This feature is available when the O/E is
used on a supported oscilloscope. The universal reference receiver supports any
data rate up to 3 GHz and remains calibrated on any channel of the oscilloscope.
Features
Frequency range to 5 GHz (6 GHz optical)
62.5 µm or narrower multi-mode or single-mode
fiber input
Broad wavelength range:
– 500–870 nm (OE425, OE525)
– 950–1630 nm (OE455, OE555)
High responsivity
Low noise
Included Accessories:
Multi-mode optical ber jumper FC-FC
FC to ST adapter
FC to SC adapter
Specications
OE425/OE525 OE455/OE555
Wavelength Range 500 – 870 nm
460 – 870 nm
(0.1 V/mW)
950 1630 nm
800 – 1630 nm
(0.1 V/mW)
Conversion Gain 0.5 V/mW 1.1 V/mW
Bandwidth 5 GHz
(6 GHz optical)
3.5 GHz
(4.5 GHz optical)
Equivalent Noise 2.2 µW rms 1.0 µW rms
Maximum Optical Power
(at 5% Saturation)
2.2 mW 1.0 mW
Rise Time 90 ps 108 ps
Maximum Safe Input 5.5 mW 2.5 mW
Temperature Drift 0.00275 dB / °C 0.00275 dB / °C
Frequency Response Ripple 1.1 dB 1.1 dB
Connector Type FC/PC FC/PC
42
PASSIVE PROBES
42
43
PASSIVE PROBES
Passive probes are the standard probe provided with most
oscilloscopes. Typical passive probes provide a ÷10 attenuation and
feature a high input resistance of 10 MΩ. This high input resistance
means that passive probes are the ideal tool for low frequency signals
since circuit loading at these frequencies is minimized. Passive probes
are designed to handle voltages of at least 400 V, some as high as
600 V. Teledyne LeCroy passive probes feature an attenuation sense
pin which tells the oscilloscope to scale the waveforms automatically
requiring no user input.
Teledyne LeCroy
Passive Probe
Model Numbers:
PP006A
PP007-WR
PP008
PP009
PP010
PP011
PP016
PP017
PP018
PP019
PP020
44
PASSIVE PROBES
Ordering Information
Product Description Product Code
÷10, 500 MHz 10 MΩ Passive Probe PP006A
÷10, 500 MHz 10 MΩ Passive Probe PP007-WR
÷10, 500 MHz 10 MΩ Passive Probe PP008
÷10, 500 MHz 10 MΩ Passive Probe PP009
÷10, 200 MHz 10 MΩ Passive Probe PP010
÷10, 500 MHz 10 MΩ Passive Probe PP011
÷10, 300 MHz 10 MΩ Passive Probe PP016
÷10, 250 MHz 10 MΩ Passive Probe PP017
÷10, 500 MHz 10 MΩ Passive Probe PP018
÷10, 200 MHz 10 MΩ Passive Probe PP019
÷10, 500 MHz 10 MΩ Passive Probe PP020
Specications
Types Bandwidth Input R Input C Attenuation Maximum Diameter
Voltage
PP006A 500 MHz 10 MΩ 12 pF ÷10 600 V 5 mm
PP007-WR 500 MHz 10 MΩ 9.5 pF ÷10 400 V 2.5 mm
PP008 500 MHz 10 MΩ 9.5 pF ÷10 400 V 2.5 mm
PP009 500 MHz 10 MΩ 9.5 pF ÷10 400 V 2.5 mm
PP010 500 MHz 10 MΩ 9.5 pF ÷10 400 V 2.5 mm
PP011 50 MHz 10 MΩ 9.5 pF ÷10 400 V 5 mm
PP016 300 MHz/ 10 MΩ/ 12 pF/ ÷10/ 600 V 5 mm
10 MHz 1 MΩ 46 pF ÷1
PP017 200 MHz 10 MΩ 12 pF ÷10 600 V 5 mm
PP018 500 MHz
10 MΩ
10 pF
÷10
600 V
5 mm
PP019 200 MHz 10 MΩ 12 pF ÷10 500 V 5 mm
PP020 500 MHz
10 MΩ
11 pF
÷10
500 V
5 mm
Each passive probe is recommended for a certain oscilloscope, using the right
passive probe with the right oscilloscope means that the probe can be properly
compensated across the entire bandwidth. Using probes with a different
oscilloscope will only let you compensate for low frequencies.
Features
Bandwidth from 200 MHz to 500 MHz
Probe encoding ring for automatic scale factor readout on Teledyne LeCroy
oscilloscopes
Teledyne LeCroy
Passive Probe
Model Numbers:
PP006A
PP007-WR
PP008
PP009
PP010
PP011
PP016
PP017
PP018
PP019
PP020
45
PASSIVE PROBES
PK1-5MM-109
Spring Tip 0.8 mm
PK1-5MM-118
Ground Spring 5.0
PK1-5MM-123
HF Compensated
Ground Lead 22 cm
PK1-5MM-102
Ground Lead 11 cm
PK1-5MM-108
IC-Cap 5.0
2.54 mm pitch; black
PK1-5MM-107
PCB Adapter 5.0
PK1-5MM-103
Adjustment Tool
Protection Cap 5.0
black
PK1-5MM-105
IC-Cap 5.0
Insulating Cap
PK1-5MM-117
Flexible Adapter
5.0 to 5 mm
banana plug
PK1-5MM-116
Flexible Adapter
5.0 to 2 mm
banana plug
PK1-5MM-101
Sprung Hook II 5.0
black
PK1-5MM-122
Ground Lead 22 cm
to 4 mm banana plug
PK1-5MM-121
PK1-5MM-119
Ground Lead 11 cm to miniclip
PK1-5MM-120
Ground Lead 11
cm to 0.8 mm plug
PK1-5MM-111
Adapter 5.0 to
0.8 mm socket
PK1-5MM-112
Dual Adapter
5.0 to 0.8 mm socket
PK1-5MM-114Y,
PK1-5MM-114G
QFP IC-Clip 13 mm long
down to 0.5 mm pitch
( X : 4 = yellow; 5 = green )
PK1-5MM-115Y
PK1-5MM-115G
QFP IC-Clip short
down to 0.5 mm pitch
( X : 4 = yellow; 5 = green )
PK1-5MM-113
Pico hook \U+2122
PK1-5MM-124
Spring Tip 0.38 mm
PK1-5MM-110
BNC Adapter 5.0
PK1-5MM-104
Rigid Tip 0.8 mm
K1-5MM-106
Set Coding Rings
3x4 colors
Ground Lead 22 cm
to 2 mm banana plug
1.0 mm x 4
5.8 mm
1.5 mm
5,8 [0,228]
1 [0,039]
1,5 [0,059]
PK007-031
BNC Adapter
PK007-015
PCB Adapter
PK007-005
Spring Tip 0.5 mm
PK007-004
Rigid Tip 0.5 mm
PK007-016
Ground Spring
PK007-013
Ground Blade
PK007-024
Probe Tip Ground Lead
with 0.8 mm Socket
PK007-025
Probe Tip Ground Lead
with Alligator Clip
PK007-014
Device Under
Test
10 Copper Pads
( 2 x 2 cm )
PK007-002
Standard Ground Lead
PK007-029
Ground Lead with 4 mm plug
PK007-028
Ground Lead
with 2 mm plug
PK007-026
Ground Lead with
mini clip
PK007-027
Ground Lead with 8 mm socket
PK007-020
Micro Clip, Long
PK007-021
Micro Clip, Short
PK007-019
Pico Hook
PK007-001
Sprung Hook
PK007-023
Adapter, 4 mm plug
PK007-022
Adapter, 2 mm plug
PK007-017
Single Lead Adapter
PK007-018
Dual Lead Adapter
PK007-030
High Frequency
Compensated Ground Lead
PK007-008
IC Cap
0.5 mm pitch
(green)
PK007-009
IC Cap
0.65 mm pitch
(blue)
PK007-010
IC Cap
0.8 mm pitch
(gray)
PK007-011
IC Cap
1.0 mm pitch
(brown)
PK007-012
IC Cap
1.27 mm pitch
(black)
PK007-007
Insulating Cap Protection Cap
PK1-5MM-103
Adjustment Tool
PK007-006
Color Coding Rings
(set)
Passive Probe Accessories
for PP007 and PP008 Series
Passive Probe Accessories
for PP009, and PP011 Series
46
PROBE ADAPTERS
47
PROBE ADAPTERS
Teledyne LeCroy
Probe Adapter
Model Numbers:
CA10
TPA10
Opposite page:
TPA10 Probe Adapter with an HDO Oscillosocope
Probe adapters provide simple and easy interface of third-party probes as
well as change between the different Teledyne LeCroy Oscilloscope input
and cable types (ProBus, ProLink, K/2.92 mm, BNC and SMA). Depending
on the adapters, changing between the Teledyne LeCroy Oscilloscope’s
input type may have an effect on the overall performance of the channel.
48
CA10 Key Features
Provides ability for third party
current sensor to operate like a
Teledyne LeCroy probe
Programmable EEPROM for
saving third party current sensor
parameters
Allows for addition of shunt
resistor and RLC lter
components
ProBus Active interface with
automatic scaling in A/div
Easy to use, saves time and
possible errors
CA10
The CA10 is a programmable and customizable interface device that seamlessly
incorporates third party current transducers/transformers with Teledyne LeCroy
oscilloscopes or motor drive analyzers. The easy to use interface provides the
ability for the CA10 to be programmed to contain the specications of the current
sensor allowing it to automatically correct for the gain or attenuation and display
results in Ampere units. This allows the third party device to be recognized and
operate as if it were a Teledyne LeCroy probe.
Product Description Product Code
ProBus Current Sensor Adapter CA10
Set of 4 CA10, ProBus Current Sensor Adapter CA10-QUADPAK
Included with Standard Conguration CA10
Description Qty
CA10 ProBus Current Adapter
1
Heat-Shrink tubing (6" length)
1
Removable Labels (sheet of 20)
1
Included with Standard Conguration CA10-QUADPAK
Description Qty
CA10 ProBus Current Adapter
4
Carrying Case
1
Heat-Shrink tubing (24" length)
1
Removable Labels (sheet of 20)
4
Specications
Input Coupling DC, AC, Both
Input Termination 1MΩ or 50Ω
Programmable Bandwidth Filters Full, 200 MHz, 20 MHz
Transformer/Transducer Interface BNC
Scaling Factors Programmable
Resistive Termination (if required) Customizable (See Operator’s Manual for details)
Oscilloscope Interface Teledyne LeCroy ProBus
Note: Some third party devices will require a separate power supply or batteries. The CA10 does not have
the ability to supply the power to these devices.
Ordering Information
Teledyne LeCroy
Probe Adapter
Model Numbers:
CA10
TPA10
PROBE ADAPTERS
49
TPA10 Key Features
Allows TekProbe™ interface level II
probes to work with any
ProBus-equipped Teledyne LeCroy
oscilloscope
Automatic probe detection
Provides all necessary power and
offset control to the attached probe
Supports probes up to 4 GHz
Easy rmware updates
Wide variety of probes
supported including:
Preampliers
Current Probes
Single-Ended Active Probes
Differential Active Probes
TPA10
The TPA10 ProBus™ Probe Adapter enables you to connect select TekProbe
interface level II probes to any ProBus-equipped Teledyne LeCroy instrument.
The TPA10 supplies all necessary power and offset control to the probe and
automatically detects which probe is attached.
Product Description Product Code
TPA10 ProBus Adapter TPA10
Set of 4 TPA10, TPA10 ProBus Adapters TPA10-QUADPAK
Supported Probes
The following TekProbe devices are supported for use
with TPA10:
Preampliers
1 MHz Differential Preamplier ADA400A
Current Probes
50 MHz AC/DC Current Probe TCP202/TCP202A
Single-ended Active Probes
750 MHz Single-ended Active Probe P6205
1 GHz Single-ended Active Probe P6243
1.5 GHz Single-ended Active Probe P6245
4 GHz Single-ended Active Probe P6241
4 GHz Single-ended Active Probe P6249
Differential Active Probes
100 MHz Differential Probe P5205/P5205A
50 MHz Differential Probe P5210/P5210A
400 MHz Differential Probe P6246
1 GHz Differential Probe P6247
1.5 GHz Differential Probe P6248
500 MHz Differential Probe P6250
1 GHz Differential Probe P6251
Specications
Electrical Characteristics
Bandwidth 4 GHz (adapter only)
Power Supplies +15V, -15V, +5V, -5V (each 2%)
Offset Voltage ±1V (1%)
Max. Input Voltage 47 Vpk, 33 Vrms
Environmental
Operating Temperature Range 0 to 50 ºC
Non-operating Temperature Range -40 to +70 ºC
Humidity 5% to 95% RH (10 to 40 ºC);
5% to 75% (above 40 ºC);
RH not controlled below 10 ºC
Operating Altitude 3000 meters maximum
Physical
Dimensions (WxHxD) 39 mm x 31.1 mm x 88.6 mm
(1.54” x 1.22” x 3.49”)
Weight 119 g (0.26 lb)
The TPA10 requires the Teledyne LeCroy oscilloscope to be running rmware
version 7.8.0.0 or greater.
Ordering Information
PROBE ADAPTERS
50
Transmission line probes are a special type of passive probe designed for use at
very high frequencies. They replace the high impedance probe cable found in a
traditional passive probe with a precision transmission line, with a characteristic
impedance that matches the oscilloscope input (50 Ω). This greatly reduces
the input capacitance to a fraction of a picofarad, minimizing the loading of
high frequency signals. A matching network at the tip increases the DC input
resistance. While they have lower DC input resistance than a traditional passive
probe (usually 500 Ω to 5 kΩ), the input impedance of these probes remains
nearly constant over their entire frequency range. A traditional ÷10 passive probe
will have a 10 MΩ input impedance at DC, however this impedance drops rapidly
with frequency, passing below the input impedance of a transmission line probe at
less than 100 MHz.
In some applications, transmission line probes offer advantages over active
probes. In addition to being less expensive, their passive design is more robust
to over voltage and ESD exposure. They are useful in applications producing fast
rising, narrow pulses with amplitudes which exceed the dynamic range of active
probes. They also tend to have less parasitic effects on frequency response.
TRANSMISSION LINE PROBES
Teledyne LeCroy
Transmission Line Probe
Model Number:
PP066
51
PP066
The PP066 is a high-bandwidth passive probe designed for use
with the WaveMaster and other high-bandwidth oscilloscopes
with 50 Ω input termination. This very low capacitance probe
provides an excellent solution for higher frequency applications,
especially the probing of transmission lines with 20–100 Ω
impedance. The PP066 accommodates a wide range of
applications, including probing of analog and digital ICs
commonly found in computer, communications, data storage,
and other high-speed designs.
Features:
Interchangeable attenuator tips
Signal integrity at high bandwidth
Standard SMA cable connection
Ultra low capacitance
PP066 Specications
Electrical Characteristics
Bandwidth DC to 7.5 GHz
Risetime < 47 ps
Input Capacitance < 0.20 pF
Input Resistance 500 Ω (÷10 cartridge)
1000 Ω (÷20 cartridge)
Maximum Voltage 15 V rms
Cable Length 1 m
Ordering Information
Product Description Product Code
7.5 GHz Low Capacitance Passive Probe
(÷10, 1 kΩ; ÷20, 500 Ω)PP066
Included with PP0066
PACC-AD001, SMA to BNC Adapter
TRANSMISSION LINE PROBES
tlec_probecatalog-17sep15
© 2015 Teledyne LeCroy, Inc. All rights reserved. Specications, prices, availability, and delivery subject to change without notice.
Product or brand names are trademarks or requested trademarks of their respective holders.
Local sales oces are located throughout the world.
Visit our website to nd the most convenient location.
1-800-5-LeCroy
teledynelecroy.com