Absolute Maximum Ratings (@ 25˚ C)
Parameter Ratings Units
Blocking Voltage (VDRM) 600 VP
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
Input Power Dissipation 1150 mW
Total Power Dissipation 22400 mW
Isolation voltage Input to Output 3750 Vrms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate Linearly 1.33 mW / ºC
2 Derate Linearly 20 mW / ºC
Electrical Characteristcs
Parameters Conditions Symbol Min Typ Max Units
Output Characteristics @ 25°C
Load Current, Continuous VL=120-240Vrms IL0.005 - 2 Arms
Maximum Surge Current t < 16ms IPK --20 A
Off State Leakage Current VDRM I
LEAK --1 mA
On-State Voltage Drop 1IL=2Arms - - 0.86 1.15 Vrms
Critical Rate of Rise - dv/dt 1000 1200 - V/μs
Switching Speeds
Turn-on IF = 5 mA tON - - 0.5 cycles
Turn-off tOFF - - 0.5 cycles
Zero-Cross Turn-On Voltage 1st half cycle - - 2 10 V
Subsequent half cycle - - - 2 V
Holding Current - IH- 0.82 5 mA
Latching Current - IL- 0.84 6 mA
Operating Frequency 2- 20 - 500 Hz
Load Power Factor for
Guaranteed Turn-On 360Hz PF 0.25 - - -
Input Characteristics @ 25°C
Input Control Current 460Hz IF--5 mA
Input Drop-out Voltage - - 0.8 - - V
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR--10 μA
Common Characteristics @ 25°C
Input to Output Capacitance - CI/O --3 pF
1 Tested at a peak value equivalent.
2 Zero Cross 1st half cycle @ <100Hz.
3 Snubber circuits may be required at low power factors.