Floating Outputs
Since these are isolated DC/DC converters, their outputs are "fl oating."
Users may ground either the Common (pin 6) for normal usage or the posi-
tive side (+Output, pin 3) to effectively reverse the output polarity.
Filtering and Noise Reduction
All UWR 5 Watt DC/DC Converters achieve their rated ripple and noise
specifi cations without the use of external input/output capacitors. In criti-
cal applications, input/output ripple and noise may be further reduced by
installing low-ESR, tantalum or electrolytic capacitors across the input
and/or output terminals. The capacitors should be located as close to the
power converters as possible. Typical values are listed below. In many
applications, using values greater than those listed will yield better results.
To Reduce Input Ripple
"D24" Models 20µF, 50V
"D48" Models 10µF, 100V
To Reduce Output Ripple
5V Outputs 47µF, 10V, Low ESR
12/15V Outputs 33µF, 20V, Low ESR
Input Fusing
Certain applications and/or safety agencies may require the installation of
fuses at the inputs of power conversion components. For DATEL UWR
5 Watt DC/DC Converters, you should use fast-blow type fuses with values
no greater than 0.5A.
ABSOLUTE MAXIMUM RATINGS
TECHNICAL NOTES
Input Voltage:
"D24" Models 40 Volts
"D48" Models 80 Volts
Input Reverse-Polarity Protection Current must be < 6A. Brief
duration only. Fusing recommended.
Output Overvoltage Protection:
5V Outputs 6.8 Volts, limited duration
12V Outputs 15 Volts, limited duration
15V Outputs 18 Volts, limited duration
Output Current Current limited. Max. current and
short-circuit duration are model
dependent.
Storage Temperature –55 to +125°C
Lead Temperature (soldering, 10 sec.) +300°C
These are stress ratings. Exposure of devices to greater than any of these conditions
may adversely affect long-term reliability. Proper operation under conditions other than
those listed in the Performance/Functional Specifi cations Table is not implied.
Performance/Functional Specifi cations
Typical @ TA = +25°C under nominal line voltage and full-load conditions, unless noted. ➀
➀ These power converters require a minimum 20% loading to maintain specifi ed regulation.
Operation under no-load conditions will not damage these devices; however
they may not meet all listed specifi cations.
INPUT
Input Voltage Range:
"D24" Models 18-36 Volts (24V nominal)
"D48" Models 36-72 Volts (48V nominal)
Input Current See Ordering Guide
Input Filter Type ➁ LC on "D24" models
C on "D48" models
Reverse-Polarity Protection Yes (Instantaneous, 6A maximum)
OUTPUT
VOUT Accuracy (50% load):
5V Outputs ±1.5%, maximum
12/15V Outputs ±1%, maximum
Temperature Coeffi cient ±0.02% per °C
Ripple/Noise (20MHz BW) ➁ See Ordering Guide
Line Regulation See Ordering Guide
Load Regulation See Ordering Guide
Effi ciency See Ordering Guide
Isolation Voltage ➂ 1000Vdc, minimum
Current Limiting Auto-recovery
Overvoltage Protection Zener/transorb clamp
DYNAMIC CHARACTERISTICS
Transient Response (50% load step) 500µsec max. to ±2% of fi nal value
Switching Frequency 170kHz (±10kHz)
ENVIRONMENTAL
Operating Temperature (Ambient): ➃
Without Derating –25 to +60°C
With Derating to +95°C (See Derating Curve)
Storage Temperature –55 to +125°C
Flammability UL94V-0
PHYSICAL
Dimensions 1" x 1" x 0.45" (25.4 x 25.4 x 11.4mm)
Shielding 5-sided
Case Connection:
"D24" Models Pin 2 (–VIN)
"D48" Models Pin 1 (+VIN)
Case Material Corrosion resistant steel with
non-conductive, powder coat matte black
fi nish and plastic baseplate
Pin Material Gold plate over copper alloy
Weight 0.7 ounces (20 grams)
www.murata-ps.com/support
UWR Models
Single Output, Miniature, 1" x 1", 5 Watt, DC/DC Converters
UWR5W_C02 Page 3 of 5