Page 61
Part No. Style Max.
Watts
Resistance
Range
D E F G H J l L M
ARA2 QR80 120W 33 16 28 26 22 6 115 148 167 0.2 ~ 4
ARA5 QR100 150W 33 16 28 26 22 6 140 173 192 0.3 ~ 5
ARA8 QR120 180W 33 16 28 26 22 6 165 198 217 0.3 ~ 6
ARBB QR150 225W 33 16 28 26 22 6 195 228 247 0.4 ~ 8
ARC0 QR200 300W 33 16 28 26 22 6 254 287 306 0.5 ~10
ARD5 QR300 450W 48 25 40 40 40 9 254 308 334 0.8 ~ 15
ARF0 QR400 600W 48 25 40 40 40 9 330 384 410 1 ~ 20
Dimension (mm) (±1)
Note: Part number & ordering procedure the same as wire-wound resistors.
POWER TYPE WIRE-WOUND RESISTOR
Performance Specifications:
Characteristics Test Methods Limits
Temperature coefficient
JIS – C – 5202 5.2
Natural resistance change per temp. degree centigrade
R2 – R1
x 106 (PPM / ºC)
R1(t2-t1)
R1 : Resistance value at room temperature (t1)
R2 : Resistance value at room temp. plus 100ºC (t2)
± 350PPM / °C
< 20 ± 400PPM / °C
Short – time overload
JIS – C – 5202 5.5
Permanent resistance change after the application of a potential of 2.5
times RCWV for 5 seconds.
Resistance change rate is
± (2% + 0.05)
No evidence of mechanical damage
Terminal Strength
JIS – C – 5202 6.1
Direct Load:
Resistance to a 2.5 kg. direct load for 10 seconds in the
Direction of the longitudinal axis of the terminal leads.
Twist Test:
Terminal leads shall be bent through 90º at a point of about 6mm
from the body of the resistor and shall be rotated through 360º about
the original axis of the bent terminal in alternating
direction for a total 3 rotations.
No evidence of mechanical damage
Resistance to Soldering Heat
JIS – C – 5202 6.4
Permanent resistance change when leads immersed to 3.2 mm to 4.8
mm from the body in 350°C ± 10°C solder for 3 ± 0.5 seconds
Resistance change rate is ± ( 1%+0.05 )
No evidence of mechanical damage.
Solderability
JIS – C – 5202 6.5
The area covered with a new, smooth, clean, shiny and continuous
surface free from concentrated pinholes.
Test temp. of solder: 235°C ± 5°C
Dwell time in solder: 3 +0.5/ -0 seconds
95% coverage Min.
Load life in humidity
JIS - C - 5202 7.9
Resistance change after 1,000 hours operating at RCWV with
duty cycle of (1.5 hours “on”, 0.5 hour “off”) in a humidity test
chamber controlled at 40°C ± 2°C and 90 to 95% relative
humidity.
Resistance change rate is
± (5% + 0.05)
No evidence of mechanical damage
Load life
JIS - C - 5202 7.10
Permanent resistance change after 1,000 hours operating at
RCWV with duty cycle of (1.5 hours “on”, 0.5 hour “off”) at
70°C ± 2°C ambient.
Resistance change rate is
± (5% + 0.05)
No evidence of mechanical damage
2004 - 2005