5SDA 07P32
ABB s.r.o., Novodvorska 1768/138a, 142 21 Praha 4, Czech Republic
ABB s.r.o. reserves the right to change the data contained herein at any time without notice
TS - DA/128/04 Jul-10 3 of 3
Maximum Ratings Maximum Limits Unit
VRRM Repetitive peak reverse
voltage
Tj = -40 ÷ 160 °C
5SDA 07P32..
5SDA 07P29.. 3 200
2 900 V
VRSM Non-repetitive peak reverse
voltage
Tj = -40 ÷ 160 °C
5SDA 07P32..
5SDA 07P29.. 3 200
2 900 V
IFAVm Average forward current
Tc = 85 °C 690 A
IFRMS RMS forward current
Tc = 85 °C 1 083 A
IRRM Repetitive reverse current
VR = VRRM 50 mA
tp = 8.3 ms 9 800 A
IFSM Non repetitive peak surge current
VR = 0 V, half sine pulse tp = 10 ms 9 200 A
tp = 8.3 ms 400 000 A2s
I2t Limiting load integral
VR = 0 V, half sine pulse tp = 10 ms 423 000 A2s
Tj = 45 °C 70 kW
PRSM Maximum avalanche power
dissipation
tp = 20 µs, single pulse Tj = 160 °C
50 kW
Tjmin -Tjmax Operating temperature range -40 ÷ 160 °C
TSTG Storage temperature range -40 ÷ 160 °C
Unless otherwise specified Tj = 160 °C
Value Characteristics
min typ max
Unit
VT0 Threshold voltage 0.930
V
rT Forward slope resistance
IF1 = 800 A, IF2 = 2 400 A 0.520
mΩ
VFM Maximum forward voltage
IFM = 1 800 A, Tj = 25 °C 1.700
V
Rthjc Thermal resistance junction to case 60 K/kW
Unless otherwise specified Tj = 160 °C
Notes: