Solid State Sensors Linear Current Sensors CS Series FEATURES 1 Linear output 1 AC or DC current sensing 1 Through-hole design 1 Fast response time 1 Output voltage isolation from input 1 Minimum energy dissipation 1 Maximum current limited only by conductor size 1 Adjustable performance and built-in temperature compensation assures reliable operation 1 Accurate, low cost sensing 1 Operating temperature range - 25 to 85C 1 Housing: PET polyester LINEAR CURRENT SENSORS MICRO SWITCH CS series linear current sensors incorporate our 91SS12-2 and SS94A1 linear output Hall effect transducer (LOHETTM). The sensing element is assembled in a printed circuit board mountable housing. This housing is available in four configuration as shown in mounting dimension figures 1, 1a, 2 and 2a. Normal mounting is with 0.375 inch long 4-40 screw and square nut (not provided) inserted in the housing or a 6-20 self-tapping screw. The combination of the sensor, flux collector, and housing comprises the holder assembly. These sensors are ratiometric. ORDER GUIDE -- BOTTOM MOUNT WITH 9SS SENSOR, SOURCE OUTPUT Catalog Listing Mtg. Dim. Fig. Supply Volt. (Volts DC) Supply Current (mA Max.) Sensed Current (Amps Peak) Offset Volt. (Volts10%) Sensitivity mV&N* At 12 VDC Nominal TOL Offset Shift (%/C) Response Time ( Sec.) CSLA1CD 1 8 to 16 19 57 Vcc/2 49.6 5.8 .05 3 CSLA1CE 1 8 to 16 19 75 Vcc/2 39.4 4.4 .05 3 CSLA1DE 2 8 to 16 19 75 Vcc/2 39.1 4.8 .05 3 CSLA1CF 1 8 to 16 19 100 Vcc/2 29.7 2.7 .05 3 CSLA1DG 2 8 to 16 19 120 Vcc/2 24.6 2.1 .05 3 CSLA1CH 1 8 to 16 19 150 Vcc/2 19.6 1.8 .05 3 CSLA1DJ 2 8 to 16 19 225 Vcc/2 13.2 1.2 .05 3 CSLA1EJ 1a 8 to 16 19 225 Vcc/2 13.2 1.5 .05 3 CSLA1DK 2 8 to 16 19 325 Vcc/2 9.1 1.7 .05 3 CSLA1EK 1a 8 to 16 19 325 Vcc/2 9.4 1.3 .05 3 CSLA1EL 1a 8 to 16 19 625 Vcc/2 5.6 1.3 .05 3 BOTTOM MOUNT WITH SS9 SENSOR, SINK/SOURCE OUTPUT Catalog Listing Mtg. Dim. Fig. Supply Volt. (Volts DC) Supply Current (mA Max.) Sensed Current (Amps Peak) Offset Volt. (Volts2%) Sensitivity mV&N* At 8 VDC Nominal TOL Offset Shift (%/C) Response Time ( Sec.) CSLA2CD 1 6 to 12 20 72 Vcc/2 32.7 3.0 .02 3 CSLA2CE 1 6 to 12 20 92 Vcc/2 26.1 2.1 .02 3 CSLA2DE 2 6 to 12 20 92 Vcc/2 25.6 2.2 .02 3 CSLA2CF 1 6 to 12 20 125 Vcc/2 19.6 1.3 .02 3 CSLA2DG 2 6 to 12 20 150 Vcc/2 16.2 1.1 .02 3 CSLA2DJ 2 6 to 12 20 225 Vcc/2 8.7 0.6 .020 3 CSLA2DH 2 6 to 12 20 235 Vcc/2 9.8 1.1 .0125 3 CSLA2EJ 1a 6 to 12 20 310 Vcc/2 7.6 0.7 .0125 3 CSLA2DK 2 6 to 12 20 400 Vcc/2 5.8 0.5 .0125 3 CSLA2EL 1a 6 to 12 20 550 Vcc/2 4.3 0.4 .0125 3 CSLA2EM 1a 6 to 12 20 765 Vcc/2 3.1 0.3 .007 3 CSLA2EN 1a 6 to 12 20 950 Vcc/2 2.3 0.2 .007 3 NOTE: When monitoring purely AC current with zero DC component, a capacitor can be inserted in series with the output of the current sensor. The capacitor will block out the effect of the temperature variation of the offset voltage which increases the accuracy of the device. * N = number of turns PDFINFO p a g e - 0 5 8 58 Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Solid State Sensors Linear Current Sensors CS Series SIDE MOUNT WITH 9SS SENSOR, SOURCE OUTPUT Sensitivity Catalog Listing Mtg. Dim. Fig. Supply Volt. (Volts DC) Supply Current (mA Max.) Current (Amps Peak) Sensed Offset Volt. (Volts10%) Nominal CSLA1GD 2a 8 to 16 19 57 Vcc/2 49.6 CSLA1GE 2a 8 to 16 19 75 Vcc/2 CSLA1GF 2a 8 to 16 19 100 Vcc/2 mV&N* At 12 VDC TOL Offset Shift (%/C) Response Time ( Sec.) 5.8 .05 3 39.4 4.4 .05 3 29.7 2.7 .05 3 Response Time ( Sec.) SIDE MOUNT WITH SS9 SENSOR, SINK/SOURCE OUTPUT Sensitivity mV&N* At 8 VDC Catalog Listing Mtg. Dim. Fig. Supply Volt. (Volts DC) Supply Current (mA Max.) Sensed Current (Amps Peak) Offset Volt. (Volts2%) Nominal TOL Offset Shift (%/C) CSLA2GD 2a 6 to 12 20 72 Vcc/2 32.7 3.0 .02 8 CSLA2GE 2a 6 to 12 20 92 Vcc/2 26.1 2.1 .02 8 CSLA2GF 2a 6 to 12 20 125 Vcc/2 19.6 1.3 .02 8 CSLA2GG 2a 6 to 12 20 150 Vcc/2 12.7 0.6 .02 8 NOTE: When monitoring purely AC current with zero DC component, a capacitor can be inserted in series with the output of the current sensor. The capacitor will block out the effect of the temperature variation of the offset voltage which increases the accuracy of the device. *N = number of turns. MOUNTING DIMENSIONS (for reference only) Figure 1 Figure 2 PDFINFO Current Figure 1a Figure 2a * Application consideration: The output is clamped at the high end. Clamping voltage may be as low as 9VDC. The output will not exceed the clamping voltage regardless of field strength or supply voltage. Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada 59 p a g e - 0 5 9