161
DC
CATALOG No. C1097B001 '20.1.IT
DC Fan 120 mm sq.
DC Fan
120×120×25 mm
San Ace 120 9GA type Low Power Consumption Fan
General Specications
·Material …………………………………… Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0)
·Expected life ………………………………
See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C, rated voltage)
Expected life at 40°C is for reference only.
·Motor protection function ……………… Locked rotor burnout protection, Reverse polarity protection
For details, please refer to p. 573.
·Dielectric strength ……………………… 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame)
·Insulation resistance …………………… 10 MΩ or more with a 500 VDC megger (between lead wire conductors and frame)
·Sound pressure level (SPL) …………… At 1 m away from the air inlet
·Storage temperature …………………… -30 to +70˚C (Non-condensing)
·Lead wire ………………………………… Red Black Sensor Yellow Control Brown
(For models without PWM control function, there is no speed control wiring.)
·Mass ……………………………………… 280 g
Specications
The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers.
Model no.
Rated voltage
Operating voltage range
PWM duty
cycle
*
[%]
Rated current
Rated input
Rated speed Max. airow
Max. static pressure
SPL
Operating temperature
Expected life
[V] [V] [A] [W] [min-1]
[m/min]
[CFM] [Pa] [inchH2O] [dB (A)] [˚C] [h]
9GA1212P4G001
12 10.2 to 13.8
100 0.93 11.16 6400 3.8 134 365 1.47 57
-20 to +70
40000/60˚C
(70000/40˚C)
25 0.16 1.92 2550 1.5 53 60 0.24 34
9GA1212P4S001 100 0.61 7.32 5400 3.2 113 260 1.04 54
25 0.16 1.92 2550 1.5 53 60 0.24 34
9GA1224P4G001
24 20.4 to 27.6
100 0.47 11.28 6400 3.8 134 365 1.47 57
25 0.1 2.4 2550 1.5 53 60 0.24 34
9GA1224P4S001 100 0.31 7.44 5400 3.2 113 260 1.04 54
25 0.1 2.4 2550 1.5 53 60 0.24 34
9GA1248P4G001
48 40.8 to 53
100 0.24 11.52 6400 3.8 134 365 1.47 57
25 0.08 3.84 2550 1.5 53 60 0.24 34
9GA1248P4S001 100 0.16 7.68 5400 3.2 113 260 1.04 54
25 0.08 3.84 2550 1.5 53 60 0.24 34
* PWM input frequency is 25 kHz; models without specications at 0% PWM duty cycle have zero fan speed at 0%.
The following sensor and control options are available for selection.
Available for all models. Pulse sensor
Differs according to the model. Refer to the table on p. 605. Without sensor Lock sensor
The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers.
Model no.
Rated voltage
Operating voltage range
Rated current
Rated input Rated speed Max. airow
Max. static pressure
SPL
Operating temperature
Expected life
[V] [V] [A] [W] [min-1]
[m/min]
[CFM] [Pa] [inchH2O] [dB (A)] [˚C] [h]
9GA1212G4001 12 7 to 13.8 0.93 11.16 6400 3.8 134 365 1.47 57
-20 to +70
40000/60˚C
(70000/40˚C)
9GA1212S4001 0.61 7.32 5400 3.2 113 260 1.04 54
9GA1224G4001 24 14 to 27.6 0.47 11.28 6400 3.8 134 365 1.47 57
9GA1224S4001 0.31 7.44 5400 3.2 113 260 1.04 54
9GA1248G4001 48 36 to 53 0.24 11.52 6400 3.8 134 365 1.47 57
9GA1248S4001 0.16 7.68 5400 3.2 113 260 1.04 54
The following sensor and control options are available for selection.
Available for all models. PWM control
Differs according to the model. Refer to the table on p. 605.
The mark indicates Short Lead Time Service applicable models. See p. 626 for details.