1 Amp Rectifier
DO-41
Features
Low Current Leakage
Metalurgically Bonded Construction
Low Cost
Maximum Ratings
BD
CA
FE
(Lead Cut Bend)
Operating Temperature: -50°C to +125°C
Storage Temperature: -50°C to +150°C
Maximum Thermal Resistance; 20°C/W Junction To Lead
MCC
Catalog
Number
Device
Marking Maximum
Recurrent
Peak
Reverse
Voltage
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
1N4001-BC02 --- 50V 35V 50V
1N4002-BC02 --- 100V 70V 100V
1N4003-BC0 2 --- 200V 140V 200V
1N4004-BC02 --- 400V 280V 400V
1N4005-BC02 --- 600V 420V 600V
1N4006-BC02 --- 800V 560V 800V
1N4007-BC02 --- 1000V 700V 1000V
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current IF(AV) 1.0A TA = 75°C
Peak Forward Surge
Current IFSM 30A 8.3ms, half sine
Maximum
Instantaneous
Forward Voltage VF 1.1V IFM = 1.0A;
TJ = 25°C*
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
IR5.0µA
50µATJ = 25°C
TJ = 125°C
Typical Junction
Capacitance CJ15pF Measured at
1.0MHz, VR=4.0V
*Pulse test: Pulse width 300 µsec, Duty cycle 2%
1N4001-BC02
THRU
1N4007-BC02
50 to 1000 Volts
DIMENSIONS
INCHES MM
DIM MIN MAX MIN MAX NOTE
C .166 .205 4.10 5.20
D .080 .107 2.00 2.70
E .028 .034 .70 .90
A .480 .50 12.2 12.7
B .170 .190 4.30 4.82
F .020 .040 0.50 1.01
omponents
20736 Marilla Street Chatsworth

 !"#
$% !"#
MCC
www.mccsemi.com
Revision: 3 2002/12/31
1N4001-BC02 thru 1N4007-BC02
Average Forward Rectified Current - Amperes versus
Ambient Temperature - °C
Figure 2
Forward Derating Curve
017550 75 100 125
0
.2
.4
.6
Single Phase, Half Wave
60Hz Resistive or Inductive Load
Amps
°C
150
.8
1.0
1.2
Junction Capacitance - pF versus
Reverse Voltage - Volts
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
Figure 1
Typical Forward Characteristics
4
6
20
10
Amps
.4 .6 .8 1.0 1.2 1.4
.01
.02
.04
.06
.1
.2
.4
.6
1
2
25°C
Volts
Figure 3
Junction Capacitance
.1 .2 1.4 2 10 20 404 100 200
1
2
6
10
20
100
pF
Volts
60
40
4
400 1000
TJ=25°C
MCC
www.mccsemi.com
Revision: 3 2002/12/31
1 100
4
0
10
5
20
30
8
Figure 5
Peak Forward Surge Current
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2
6
10 20 60 80
40
40
50
60
Figure 4
Typical Reverse Characteristics
Instantaneous Reverse Leakage Current - MicroAmperes versus
Percent Of Rated Peak Reverse Voltage - Volts
Volts
4
6
20
10
µAmps
20 120
40 60 80 100
.01
.02
.04
.06
.1
.2
.4
.6
1
2
TA=25°C
40
60
100
140
TA=100°C
MCC
1N4001-BC02 thru 1N4007-BC02
www.mccsemi.com
Revision: 3 2002/12/31