CPV Series PRODUCT SELECTION Description 10 A 10CPV120 10CPV240 25 A 50 A 75 A 90 A 25CPV120 25CPV240 50CPV120 50CPV240 75CPV120 75CPV240 90CPV120 90CPV240 ol e 120 VAC 240 VAC te * Phase control modules * 120/240 VAC models * 0-5 V DC phase control * Used with Series 1 random-fire solid-state relays OUTPUT SPECIFICATIONS (voltage) (1) Description Operating Voltage (47-63Hz) [Vrms] Transient Overvoltage [Vpk] Maximum Off-State Leakage Current @ Rated Voltage [mArms] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/sec] (2) 120 VAC 240 VAC 90-140 VAC 400 10 500 180-280 VAC 600 10 500 10 A 25 A 50 A 75 A 90 A 10 0.04 120 1.6 1.48 60 0.5 25 0.04 250 1.6 1.02 260 0.5 75 0.04 625 1.6 0.31 4150 0.5 50 0.04 1000 1.6 0.63 1620 0.5 90 0.04 1200 1.6 0.28 6000 0.5 OUTPUT SPECIFICATIONS (current) (1) Description Maximum Load Current (3) [Arms] Minimum Load Current [Arms] Maximum Surge Current (16.6ms) [Apk] Maximum On-State Voltage Drop @ Rated Current [Vpk] Thermal Resistance Junction to Case (Rjc) [C/W] Maximum It for Fusing (8.3 msec) [A sec] Minimum Power Factor (with Maximum Load) bs CONTROL MODULE INPUT SPECIFICATIONS (1) Description Control Voltage Range Minimum Turn-Off Voltage Typical Supply Current Nominal Control Input Impedance Maximum Turn-On Time [msec] Maximum Turn-Off Time [msec] DC Control 0-5 VDC 1.0 VDC 1.6 mA @ 5 VDC 1500 Ohm 0.02 1/2 Cycle CONTROL MODULE OUTPUT SPECIFICATIONS (Terminal 4B - Input to Relay) (1) Description O Maximum Off-State Operating Voltage Maximum Load Current (Sink) Maximum On-State Voltage @ 3 mA Max. Off State Leakage @ 10 VDC DC Control 36 VDC 3.0 mA 0.5 VDC 1.0 ADC GENERAL SPECIFICATIONS Description Dielectric Strength, signal to load Dielectric Strength, signal to Base Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) Encapsulation For Contact information visit our web site. Parameters 4000 Vrms 4000 Vrms -30 to 80C -40 to 125C 3.0 oz. (43g) Themally Conductive Epoxy www.crydom.com (c)2008 Crydom, Inc. Specifications subject to change without notice. GENERAL NOTES 1) All parameters at 25C unless otherwise spec ified. 2) Off-State dv/dt test method per EIA/NARM sta ndard RS-443, paragraph 13.11.1 3 ) Heat sinking required (relay only), see derating curves. CPV120 CPV240 Control Module Only (120 Vac Line) Control Module Only (240 Vac Line) bs ol e WIRING DIAGRAM te AVAILABLE OPTIONS AGENCY APPROVAL O Rev. 082709 For Contact information visit our web site. www.crydom.com (c)2008 Crydom, Inc. Specifications subject to change without notice. For Contact information visit our web site. www.crydom.com (c)2008 Crydom, Inc. Specifications subject to change without notice. ANNEX - ENVIROMENTAL INFORMATION For Contact information visit our web site. www.crydom.com (c)2008 Crydom, Inc. Specifications subject to change without notice.