CPV Series Phase control modules
120/240 V AC m odels
0-5 V DC phase control
Used with Series 1 random-fire solid-state relays
PRODUCT SELECTION
Description 10 A 25 A 50 A 75 A 90 A
120 VAC 10CPV120 25CPV120 50CPV120 75CPV120 90CPV120
240 VAC 10CPV240 25CPV240 50CPV240 75CPV240 90CPV240
OUTPUT SPECIFICATIONS (voltage) (1)
Description 120 VAC 240 VAC
Operating Voltage (47-63Hz) [Vrms] 90-140 VAC 180-280 VAC
Transient Overvoltage [Vpk] 400 600
Maximum Off-State Leakage Current @ Rated Voltage [mArms] 10 10
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2) 500 500
OUTPUT SPECIFICATIONS (current) (1)
Description 10 A 25 A 50 A 75 A 90 A
Maximum Load Current (3) [Arms] 10 25 75 50 90
Minimum Load Current [Arms] 0.04 0.04 0.04 0.04 0.04
Maximum Surge Current (16.6ms) [Apk] 120 250 625 1000 1200
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 1.6
Thermal Resistance Junction to Case (Rjc ) [°C/W] 1.48 1.02 0.31 0.63 0.28
Maximum I²t for Fusing (8.3 msec) [A² sec] 60 260 4150 1620 6000
Minimum Power Factor (with Maximum Load) 0.5 0.5 0.5 0.5 0.5
CONTROL MODULE INPUT SPECIFICATIONS (1)
Description DC Control
Control Voltage Range 0-5 VDC
Minimum T u rn-Off Voltage 1.0 VDC
Typical Supply Current 1.6 mA @ 5 VDC
Nominal Control Input Impedance 1500 Ohm
Maximum Turn-On Time [msec] 0.02
Maximum Turn-Off Time [msec] 1/2 Cycle
CONTROL MODULE OUTPUT SPECIFICATIONS (Terminal 4B - Input to Relay) (1)
Description DC Control
Maximum Off-State Operating Voltage 36 VDC
Maximum Load Current (Sink) 3.0 mA
Maximum On-State Voltage @ 3 mA 0.5 VDC
Max. Off State Leakage @ 10 VDC 1.0 µADC
GENERAL SPECIFICATIONS
Description Parameters
Dielectric Strength, signal to load 4000 Vrms
Dielectric Strength, signal to Base 4000 Vrms
Ambient Operating Temperature Range -30 to 80°C
Ambient Storage Temperature Range -40 to 125°C
Weight (typical) 3.0 oz. (43g)
Encapsulation Themally Conductive Epoxy
For Contact information visit our web site. www.crydom.com ©2008 Crydom, Inc.
Specifications subject to change without notice.
Obsolete
GENERAL NOTES
1 ) All p arame te rs at 25 °C unless other w ise sp ecified.
2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
3 ) Heat s inking required (relay only), see derating curves.
AVAILABLE OPTIONS
CPV120 Control Module Only (120 Vac Line)
CPV240 Control Module Only (240 Vac Line)
WIRING DIAGRAM
AGENCY APPROVAL
Rev. 082709
For Contact information visit our web site. www.crydom.com ©2008 Crydom, Inc.
Specifications subject to change without notice.
Obsolete
For Contact in formation visit our web site. www.crydom.com ©2008 Crydom, Inc.
Specifications subject to c hange without notice.
ANNEX - ENVIROMENTAL INFORMATION
For Contact in formation visit our web site. www.crydom.com ©2008 Crydom, Inc.
Specifications subject to c hange without notice.