? Fuse Terminal Blocks for Blade-Type Fuses acc. to DIN 72581-3f, ISO 8820-3, Series 2002 mm2 AWG 22 -- 12 Terminal block width 5.2 mm / 0.205 in L 10 -- 12 mm / 0.43 in 0.25 -- 2.5 (4) 400 V/6 kV/3 IN 10 A 29 mm2 AWG 22 -- 12 VOLUME 1 0.25 -- 2.5 (4) 400 V/6 kV/3 IN 10 A 1 S Terminal block width 5.2 mm / 0.205 in L 10 -- 12 mm / 0.43 in can be connected: 0.25 mm2 -- 4 mm2 "s+f-st"; <________ 66,5 mm /2.61 in ________> Item no. <_______________ 87,5 mm /3.45 in _______________> Pack. unit Item no. Pack. unit 4-conductor fuse terminal blocks 2-conductor fuse terminal blocks gray <__> mm / <__ 33 1.29 in __> mm / <___ 33 1.29 in __> <___ 38 mm /1. 49 in___> can be pushed in directly: 0.75 mm2 -- 4 mm2 "s" and 0,75 mm2 - 2,5 mm2 "insulated ferrule, 12 mm/0.472 in" 2002-1681 gray - Individual arrangement: 10 A 2002-1881 - Individual arrangement: 10 A - Block arrangement: 5 A Please note touchproof protection from 42 V - Block arrangement: 5 A Please note touchproof protection from 42 V Article-specific accessories End and intermediate plate, 1 mm/0.039 in thick orange 2002-1692 100 (4 x 25) gray 2002-1691 100 (4 x 25) Accessories Series 2002 End and intermediate plate, 1 mm/0.039 in thick orange 2002-1892 100 (4 x 25) gray 2002-1891 100 (4 x 25) Appropriate marker systems: WMB/Marker Strips/WMB Inline (see Full Line Catalog W4, Vol. 1, Sec. 14) Insulation stop, 5 pcs/strip 200 strips light gray2002-171 0.25-0.5 mm2 dark gray2002-172 0.75-1 mm2 Protective warning marker, with high voltage symbol, black, for 5 terminal blocks yellow 2002-115 100 (4 x 25) Push-in type jumper bars, light gray, insulated, IN 25 A 2-way 2002-402 200 (8 x 25) 3-way 2002-403 200 (8 x 25) 4-way 2002-404 200 (8 x 25) 5-way 2002-405 100 (4 x 25) : : 10-way 2002-410 100 (4 x 25) Staggered jumpers, light gray, insulated, IN 25 A 2-way 2002-472 100 (4 x 25) 3-way 2002-473 100 (4 x 25) 4-way 2002-474 100 (4 x 25) 5-way 2002-475 50 (2 x 25) : : 12-way 2002-482 50 (2 x 25) Push-in type jumper bars, light gray, insulated, IN 25 A Test plug adapter, for test plug O 4 mm/0.157 in 2009-174 100 (4 x 25) 1 - 3 2002-433 200 (8 x 25) 1 - 4 2002-434 200 (8 x 25) 1 - 5 2002-435 100 (4 x 25) : : 1 - 10 2002-440 100 (4 x 25) Modular TOPJOB(R)S connector, for jumper contact slot 1 pole 2002-511 100 (4 x 25) Spacer, modular 2002-549 The rated currents of the fuse cartridges are defined differently in international standards. Due to the different current rating definitions, the recommended current-carrying permanent capacity of the fuses is max. 80% of their rated current according to DIN 72581 part 3 (for an ambient operating temperature of 23C). Selecting the correct fuse cartrigde is important for product safety within applications as well as the service life/operational reliability of the fuse cartrigdes. Fuse cartrigdes can operate perfectly as protection (break-off point) if they are properly selected and are used in accordance with the manufacturers specifications. In general it is necessary to test fuse cartridges under normal conditions and operational failures within your application. Testing tap, for max. 2.5 mm2/AWG 14 2009-182 100 (4 x 25) Two-way marking adapter, pivotable 2002-121 50 (2 x 25) 100 (4 x 25) Blade-type fuses acc. to DIN 72581-3f / ISO 8820-3 (not offered by WAGO) Test plug, with cable 500mm/1'7.7'', O 2 mm/0.079 in red 210-136 50 (5 x 10) With regard to the product safety, it is in general necessary to test the fuse in the appliance under normal conditions and operational failures. 0.25 -- 2.5 (4) mm2 250 V/6 kV/3 6.3 A AWG 22 -- 12 Terminal block width 6.2 mm / 0.244 in L 10 -- 12 mm / 0.43 in 800 V = rated voltage 8 kV = rated surge voltage 3 = pollution degree (see also Full Line Catalog W4, Volume 1, Section 15) N ominal voltage and current are given by the LED or fuse Leakage current in case of blown fuse: LED 6 mA <_______ 66,5 mm /2.62 in _______> Description Item no. Fuse disconnect terminal block with pivotable fuse holder, for DIN 35 rail, for miniature metric fuses Pack. unit 2-conductor fuse terminal block with end plate, without blown fuse indication 5 x 20 mm 5 x 20 mm 5 x 20 mm 0.25 -- 2.5 (4) mm2 250 V/6 kV/3 6.3 A AWG 22 -- 12 Terminal block width 6.2 mm / 0.244 in L 10 -- 12 mm / 0.43 in gray 2002-1611 50 <______ 57,2mm /2.26in ______> VOLUME 1 34 ? Fuse Disconnect Terminal Blocks with Pivotable Fuse Holder, 2.5 (4) mm2/AWG 12, for Miniature Metric Fuses 5 x 20 mm, Series 2002 <_____ 57,2mm /2.26 in _____> 1 <_______ 66,5 mm /2.62 in _______> Item no. Pack. unit 2-conductor fuse terminal blocks with end plate, with blown fuse indication by LED gray 12 -- 30 V 2002-1611/1000-541 gray 30 -- 65 V 2002-1611/1000-542 gray 110 -- 250 V 2002-1611/1000-836 50 50 50 Article-specific accessories End plate for fuse terminal blocks, 2 mm/0.079 in thick gray 2002-991 100 (4x25) orange 2002-992 100 (4x25) Accessories Appropriate marker systems: End plate for fuse terminal blocks, 2 mm/0.079 in thick gray 2002-991 100 (4x25) orange 2002-992 100 (4x25) WMB/Marker Strips/WMB Inline (see Full Line Catalog W4, Volume 1, Section 14) Insulation stop, 5 pcs/strip 200 strips light gray2002-171 0.25-0.5 mm2 dark gray2002-172 0.75-1 mm2 must be singularized Protective warning marker, with high voltage symbol, black, for 5 terminal blocks yellow 2002-115 100 (4 x 25) must be singularized Push-in type jumper bars, light gray, insulated, IN 25 A 2-way 2004-402 200 (8 x 25) 3-way 2004-403 200 (8 x 25) 4-way 2004-404 200 (8 x 25) 5-way 2004-405 100 (4 x 25) : : 10-way 2004-410 100 (4 x 25) Insulation stop, 5 pcs/strip 200 strips light gray2002-171 0.25-0.5 mm2 dark gray2002-172 0.75-1 mm2 must be singularized Protective warning marker, with high voltage symbol, black, for 5 terminal blocks yellow 2002-115 100 (4 x 25) must be singularized Push-in type jumper bars, light gray, insulated, IN 25 A 2-way 2004-402 200 (8 x 25) 3-way 2004-403 200 (8 x 25) 4-way 2004-404 200 (8 x 25) 5-way 2004-405 100 (4 x 25) : : 10-way 2004-410 100 (4 x 25) Push-in type jumper bars, light gray, insulated, IN 25 A 1 - 3 2004-433 200 (8 x 25) 1 - 4 2004-434 200 (8 x 25) 1 - 5 2004-435 100 (4 x 25) : : 1 - 10 2004-440 100 (4 x 25) Test plug, with cable 500 mm/1'7.7'', O 2 mm/0.079 in O red 210-136 50 (5 x 10) Push-in type jumper bars, light gray, insulated, IN 25 A 1 - 3 2004-433 200 (8 x 25) 1 - 4 2004-434 200 (8 x 25) 1 - 5 2004-435 100 (4 x 25) : : 1 - 10 2004-440 100 (4 x 25) Test plug, with cable 500 mm/1'7.7'', O 2 mm/0.079 in O red 210-136 50 (5 x 10) 1 S 35 AWG 22 -- 12 Terminal block width 6.2 mm / 0.244 in L 10 -- 12 mm / 0.43 in <______ 57,2mm /2.26in ______> Terminal block width 6.2 mm / 0.244 in L 10 -- 12 mm / 0.43 in 0.25 -- 2.5 (4) mm2 250 V/6 kV/3 6.3 A <_____________ 87,5mm /3.45in _____________> Item no. Pack. unit 4-conductor fuse terminal block with end plate, without blown fuse indication gray 2002-1811 50 End plate for fuse terminal blocks, 2 mm/0.079 in thick gray 2002-991 100 (4x25) orange 2002-992 100 (4x25) VOLUME 1 AWG 22 -- 12 Application notes <______ 57,2mm /2.26in ______> 0.25 -- 2.5 (4) mm2 250 V/6 kV/3 6.3 A <_____________ 87,5 mm /3.45 in _____________> Item no. Pack. unit 4-conductor fuse terminal blocks with end plate, with blown fuse indication by LED gray 12 -- 30 V 2002-1811/1000-541 50 gray 30 -- 65 V 2002-1811/1000-542 50 gray 110 -- 250 V 2002-1811/1000-836 50 End plate for fuse terminal blocks, 2 mm/0.079 in thick gray 2002-991 100 (4x25) orange 2002-992 100 (4x25) Fuse terminal blocks with a width of 6.2 mm/0.244 in can be assembled adjacent to each other. At the end of an assembly, if there is no adjacent fuse or disconnect terminal block, an end plate for fuse terminal blocks must be used. When selecting miniature metric fuses, the maximum power loss listed below should not be exceeded. The power loss is determined according to IEC or EN 60947-7-3/VDE 0611-6 at 23C. The temperature rise of the terminal blocks must be checked according Appropriate marker systems: to their application and mounting. Higher ambient temWMB/Marker Strips/WMB Inline (see Full Line Catalog W4, Volume 1, Section 14) peratures represent an additional impact on miniature Insulation stop, 5 pcs/strip 200 strips Insulation stop, 5 pcs/strip 200 strips metric fuses. Therefore, in such applications the rated 2 2 current must be reduced if necessary. light gray2002-171 0.25-0.5 mm light gray2002-171 0.25-0.5 mm dark gray2002-172 0.75-1 mm2 dark gray2002-172 0.75-1 mm2 More details from the manufacturer. must be singularized Protective warning marker, with high voltage symbol, black, for 5 terminal blocks yellow 2002-115 100 (4 x 25) must be singularized Push-in type jumper bars, light gray, insulated, IN 25 A 2-way 2004-402 200 (8 x 25) 3-way 2004-403 200 (8 x 25) 4-way 2004-404 200 (8 x 25) 5-way 2004-405 100 (4 x 25) : : 10-way 2004-410 100 (4 x 25) must be singularized Protective warning marker, with high voltage symbol, black, for 5 terminal blocks yellow 2002-115 100 (4 x 25) must be singularized Push-in type jumper bars, light gray, insulated, IN 25 A 2-way 2004-402 200 (8 x 25) 3-way 2004-403 200 (8 x 25) 4-way 2004-404 200 (8 x 25) 5-way 2004-405 100 (4 x 25) : : 10-way 2004-410 100 (4 x 25) Push-in type jumper bars, light gray, insulated, IN 25 A 1 - 3 2004-433 200 (8 x 25) 1 - 4 2004-434 200 (8 x 25) 1 - 5 2004-435 100 (4 x 25) : : 1 - 10 2004-440 100 (4 x 25) Test plug, with cable 500 mm/1'7.7'', O 2 mm/0.079 in O red 210-136 50 (5 x 10) Push-in type jumper bars, light gray, insulated, IN 25 A 1 - 3 2004-433 200 (8 x 25) 1 - 4 2004-434 200 (8 x 25) 1 - 5 2004-435 100 (4 x 25) : : 1 - 10 2004-440 100 (4 x 25) Test plug, with cable 500 mm/1'7.7'', O 2 mm/0.079 in O red 210-136 50 (5 x 10) Miniature metric fuses 5 x 20 Series Item No. Overload and short circuit protection Short circuit protection only Individual Group Individual Group arrangementarrangement arrangementarrangement Fuse terminal blocks 2002-1611 2002-1811 1.6 W 1.6 W 2.5 W 2.5 W 2002-1811/....-.... 2002-1611/....-.... 1.6 W 1.6 W 2.5 W 2.5 W Protective warning marker and insulation stop must be singularized. Due to the 6.2 mm/0.244 in width of the fuse terminal blocks with pivotable fuse holder, 2004 Series jumpers must be used. 1 250 V max.* 6.3 max. *Electrical ratings are given by the fuse or nominal voltage of the indicator lamp respectively. <______ 71 mm /2.79 in ______> VOLUME 1 36 ? Fuse Plugs, Series 2004 and Carrier Terminal Blocks, Series 2002 <____________________ ____________________> Item no. Open side of terminal block Description Leakage current in case ofblown fuse LED 5 -- 20 mA, Neon lamp <0.4 mA Fuse plug, for miniature metric fuses 5 x 20 mm Fuse plug, same as above, with additional indicator lamp, LED, AC/DC 12 -- 30 V, LED, AC/DC 30 -- 65 V, can be used in both switching directions AC/DC 120 V -- 230 V 6.1 mm/0.24 in widthwith pull-tab 2004-0911 Pack. unit 50 The use of pluggable fuse holders with rail mounted terminal blocks for protection of control circuits offers many advantages to the user since the function and the wiring are accomplished by two separate parts: no n o 6.1 mm/0.24 in widthwith pull-tab 2004-0911/1000-0541 50 2004-0911/1000-0542 50 6.1 mm/0.24 in widthwith pull-tab 2004-0911/1000-0836 50 additional cost for assembly and wiring risk of accidental contact with live parts during disconnection of fuse plug in case of exchanging a defective fuse the fuse plug is completely separated from the carrier terminal block t herefore safe exchange of the fuse away from current carrying parts t he fuse plug can be taken away by the serviceman avoiding unintentional reclosing of the circuit by another person q uick exchange of a fuse by using a prepared "stand-by plug." Further advantages: Terminal blocks and accessories Appropriate marker systems: Terminal block WMB/Marker Strips 2-conductor carrier terminal block , 0.25--2.5(4)mm2/AWG 22--12 Stripped length 9--10 mm/0.37in End and intermediate plate, for 2-cond. carrier term. block Item No. 2002-1661 4-conductor carrier terminal block , 0.25--2.5(4)mm2/AWG 22--12 Stripped length 10--12 mm/0.43in End and intermediate plate, for 4-cond. carrier term. block Item No. 2002-1861 Shorting link, 5 x 20 mm, 6.3 A, if the fuse plug is used as disconnect plug End plate for fuse plug 66.5 mm/2.62 in (2-conductor) 87.5 mm/3.45 in (4-conductor) with inserted fuse plug Terminal block width 5.2 mm/0.205 in gray 2002-1661 1 mm/0.039 thick orange 2002-1692 gray 2002-1691 Terminal block width 6 mm/0.236 in gray 2002-1861 1 mm/0.039 thick orange 2002-1892 gray 2002-1891 281-503 2 mm/0.079 thick orange 2002-0991 gray 2002-0992 50 100 (4 x 25) 100 (4 x 25) 50 100 (4 x 25) 100 (4 x 25) 250 (10 x 25) 100 (4 x 25) 100 (4 x 25) o ptional LED indicates blown fuse m arking facility on the fuse plug for clear coordination to the correct carrier terminal block (WSB-Quick Marking System 4 mm/0.157 in) t wo touchproof test slots h igh density with only 6,1 mm/0.24 in width of terminal block/fuse plug instead of a fuse, a shorting link may be used as a disconnect plug. When corresponding Neutral-circuit is adjacent to a fuse plug, a 5.2 mm/0.205 in wide space saving terminal block may be used, as a 6.1 mm/0.24 in fuse plug may overlap the terminal block. See diagram below. Miniature metric fuses 5 x 20 Series Item No. Overload and short circuit protection Short circuit protection only Individual Group Individual Group arrangementarrangement arrangementarrangement Fuse terminal blocks 2004-0911 2004-0911/....-.... 1.6 W 1.6 W 2.5 W Open side of terminal block left 2.5 W