COMBO-D CONNECTOR SAVERS GENDER CHANGER Positronic Industries connectpositronic.com Combo-D D-Sub Professional Quality Connectors ACBDP Series Size 20 "Open Entry" or PosiBand(R) "Closed Entry" Contact Design Industrial /Military Quality Connectors - ACBMP Series Size 20 PosiBand(R) "Closed Entry" Contact Design Connector Saver O NIC INDU * IES For RoHS options see page 60. 5/ U rE Di TR * pe RoHS EC R S IT ACBDP/ACBMP connector can be easily replaced, "Saving" a connector which is not easily replaced. These connectors can also be used as a "gender changer". Connector Savers are also available in standard and high density D-subminiature versions, please consult our Professional, Industrial and Military Performance D-subminiature Connectors catalog for more information. For high density 8W2, 19W1 and 45W2 adapter variants contact Technical Sales. POS CONNECTOR SAVERS ACBDP and ACBMP series connectors are suitable for use in any applications requiring high perfor mance characteristic. The nor mal density ACBDP and ACBMP series are available in standard Combo-D connector variants. ACBDP and ACBMP series connectors utilize precision machined contacts for strength and durability. The ACBDP female contact features a rugged "Open Entry" design or PosiBand "Closed Entry" design for even higher reliability. ACBMP connectors features PosiBand "Closed Entry" contacts and military contact plating. ACBDP and ACBMP series connectors can be mated to a connector which would normally experience high numbers of mating cycles. The rec tive 2002 /9 TECHNICAL CHARACTERISTICS MATERIALS AND FINISHES: Insulator: SIGNAL CONTACTS ACBDP Series: ACBMP Series: POWER CONTACTS ACBMP Series: Contact Plating: ACBDP Series: ACBMP Series: Shells: 57 Jackscrew Systems: Glass filled polyester per MIL-M-24519 UL 94V-0, blue color. Brass or steel with zinc plate and chromate seal or clear zinc plate or tin plate; stainless steel, passivated. Non-magnetic versions are available, contact Technical Sales. Precision machined high tensile copper alloy open entry design. Precision machined copper alloy. Precision machined copper alloy closed entry design. Gold flash over nickel plate. 0.000050 [1.27] gold over nickel plate. Steel or brass with tin plate; zinc plate with chromate seal; stainless steel passivated. Other materials and finishes available upon request. DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. MECHANICAL CHARACTERISTICS: FIXED CONTACTS: Signal Contacts: Power Contacts: Size 20 contacts, male - 0.040 inch [1.02 mm] diameter. ACBDP series has female open entry contact or PosiBand closed entry contacts optional, see page 69 for details. ACBMP series offer female PosiBand closed entry contacts. Size 8 contacts, male - 0.142 inch [3.61 mm] diameter. Female contact features Large Surface Area (L.S.A.) closed entry contact design utilizing BeCu mechanical retention member. continued on next page. . . . COMBO-D CONNECTOR SAVERS GENDER CHANGER Combo-D D-Sub Positronic Industries connectpositronic.com TECHNICAL CHARACTERISTICS, continued continued from previous page. . . . MECHANICAL CHARACTERISTICS, continued: ELECTRICAL CHARACTERISTICS: Connector Saver: SIZE 20 CONTACTS Contact Current Rating: Initial Contact Resistance: Proof Voltage: Male to female or male to male. Contact Retention: Signal: Power: 9 lbs. [40 N]. 22 lbs. [98 N]. Shells: Male shells may be EMI/ESD ground paths. Polarization: dimpled for Trapezoidally shaped shells. Mechanical Operations: ACBDP Series: 500 operations, minimum, per IEC 512-5. ACBMP Series: 1,000 operations, minimum, per IEC 512-5. 7.5 amperes, nominal. 0.008 ohms, maximum. 1,000 V r.m.s. SIZE 8 CONTACTS POWER CONTACTS Contact Current Rating: 70 amperes, per U.L. 1977. See Temperature Rise Curves on pages 1-2. Initial Contact Resistance: 0.0005 ohms, maximum Proof Voltage: 1,000 V r.m.s. CONNECTOR Insulator Resistance: Clearance and Creepage Distance: Working Voltage: 5 G ohms. 0.039 inch [1.0 mm], minimum. 300 V r.m.s. Temperature Range: CONNECTOR SAVERS CLIMATIC CHARACTERISTICS: -55C to +125C. ACBDP/ACBMP SERIES SIZE 20 AND SIZE 8 CONTACT CONNECTOR SAVER CONTACT VARIANTS FACE VIEW OF MALE OR REAR VIEW OF FEMALE SHELL SIZE 1 SHELL SIZE 2 3W3 5W1 11W1 7W2 SHELL SIZE 3 5W5 9W4 13W3 21W1 17W2 SHELL SIZE 4 8W8 13W6 17W5 21WA4 25W3 27W2 SHELL SIZE 5 24W7 36W4 43W2 47W1 SHELL SIZE 6 Note: For high density 8W2, 19W1 and 45W2 variants contact Technical Sales for availability. 46W4 DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 58 COMBO-D CONNECTOR SAVERS GENDER CHANGER Positronic Industries connectpositronic.com Combo-D D-Sub MALE TO FEMALE CONNECTOR SAVER SIZE 20 AND SIZE 8 CONTACTS CODE 0 AND S 0.290 [7.37] 0.2430.005 [6.170.13] E O0.1200.005 [3.050.13] Thru hole, 2 places NOTE: Code S = Swaged spacer with 4-40 UNC-2B threads. A C B1 K1 B Molding Spacer Female Contacts Male Contacts 0.018[0.46] D1 0.0360.008 [0.910.20] CONNECTOR SAVERS CONNECTOR SIZE SHELL SIZE 1 SHELL SIZE 2 SHELL SIZE 3 SHELL SIZE 4 SHELL SIZE 5 SHELL SIZE 6 D 0.020[0.51] Max. rollover Typical Part Number: ACBMP11W1F0011W1M00 A 0.015 B 0.005 B1 0.005 C 0.005 D 0.005 D1 0.005 E 0.015 K1 0.005 1.213 [30.81] 1.541 [39.14] 2.088 [53.04] 2.729 [69.32] 2.635 [66.93] 2.729 [69.32] 0.643 [16.33] 0.971 [24.66] 1.511 [38.38] 2.159 [54.84] 2.064 [52.43] 2.189 [55.60] 0.666 [16.92] 0.994 [25.25] 1.534 [38.96] 2.182 [55.42] 2.079 [52.81] 2.212 [56.18] 0.984 [24.99] 1.312 [33.32] 1.852 [47.04] 2.500 [63.50] 2.406 [61.11] 2.500 [63.50] 0.311 [7.90] 0.311 [7.90] 0.311 [7.90] 0.311 [7.90] 0.423 [10.74] 0.485 [12.32] 0.329 [8.36] 0.329 [8.36] 0.329 [8.36] 0.329 [8.36] 0.441 [11.20] 0.503 [12.78] 0.494 [12.55] 0.494 [12.55] 0.494 [12.55] 0.494 [12.55] 0.605 [15.37] 0.668 [16.97] 0.233 [5.92] 0.233 [5.92] 0.230 [5.84] 0.230 [5.84] 0.230 [5.84] 0.230 [5.84] JACKSCREW SYSTEMS CODE E, E6, T AND T6 ROTATING MALE AND FEMALE JACKSCREWS ROTATING MALE AND FEMALE POLARIZED JACKSCREWS FIXED MALE AND FEMALE JACKSCREWS FIXED MALE AND FEMALE POLARIZED JACKSCREWS E6 T T6 E 4-40UNC-2B 4-40UNC-2A Female contacts 4-40UNC-2A 59 4-40UNC-2A 4-40UNC-2A 4-40UNC-2B Male contacts Female contacts 4-40UNC-2B Male contacts Female contacts 4-40UNC-2B Male contacts Female contacts 4-40UNC-2B 4-40UNC-2B 4-40UNC-2A 4-40UNC-2A Male contacts 4-40UNC-2A 4-40UNC-2B 4-40UNC-2B 4-40UNC-2A 0.754 [19.15] 0.754 [19.15] 0.754 [19.15] 0.754 [19.15] Example Part Number: ACBDP5W1FEX5W1M0X Example Part Number: ACBDP5W1FE6X5W1M0X Example Part Number: ACBDP5W1FTX5W1M0X Example Part Number: ACBDP5W1FT6X5W1M0X DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. COMBO-D CONNECTOR SAVERS GENDER CHANGER Combo-D D-Sub Positronic Industries connectpositronic.com ORDERING INFORMATION - CODE NUMBERING SYSTEM Specify Complete Connector By Selecting An Option From Step 1 Through 9 1 2 EXAMPLE ACBDP 11W1 3 4 5 6 7 8 9 10 11 F S X 11W1 M S X /AA -14 STEP 1 - BASIC SERIES STEP 11 - SPECIAL OPTIONS ACBDP - Professional / Industrial Quality, see Step 3. ACBMP - Military conformance with "closed entry" female signal contacts plated 0.000050 [1.27] gold over nickel plate. Choose "S" or "M" in Step 3. * 5/ Di EC * pe RoHS IES POS NIC INDU TR Shell Size 1 5W1 Shell Size 2 3W3, 7W2, 11W1 Shell Size 3 5W5, 9W4, 13W3, 17W2, 21W1 Shell Size 4 8W8, 13W6, 17W5, 21WA4, 25W3, 27W2 Shell Size 5 24W7, 36W4, 43W2, 47W1 Shell Size 6 46W4 O U rE STEP 2 - CONNECTOR VARIANT R S IT FOR SPECIAL OPTIONS, SEE SPECIAL OPTIONS APPENDIX ON PAGE 89. rec tive 2002 /9 STEP 10 - ENVIRONMENTAL COMPLIANCE OPTIONS /AA - Compliant per EU Directive 2002/95/EC (RoHS) NOTE: If compliance to environmental legislation is not required, this step will not be used. Example: ACBDP11W1FSX11W1MSX STEP 9 - 2ND CONNECTOR SHELL OPTION 0- *4 S - X- Z- Note: For high density 8W2, 19W1 and 45W2 variants contact Technical Sales for availability. Zinc Plated, with Chromate Seal. Stainless Steel, passivated. Tin Plated. Tin Plated and Dimpled (male connectors only). *2 STEP 8 - 2ND CONNECTOR MATING STYLE 0 - Swaged spacer 0.120 [3.05] mounting hole S - Swaged spacer 4-40 UNC-2B threads *3 E - Rotating male and female jackscrews (Select 0 in Step 4) *3 E6 - Rotating male and female polarized jackscrew (Select 0 in Step 4) *3 T - Fixed male and female jackscrews (Select 0 in Step 4) *3 T6 - Fixed male and female polarized jackscrew (Select 0 in Step 4) STEP 3 - 1ST CONNECTOR GENDER F - Female - Professional Level Open Entry Signal Contacts *1M - Male S - Female - Industrial / Military Level PosiBand Closed Entry Signal Contacts. Military gold plating is optional. *2 STEP 4 - 1ST CONNECTOR MATING STYLE 0 - Swaged spacer 0.120 [3.05] mounting hole S - Swaged spacer 4-40 UNC-2B threads *3 E - Rotating male and female jackscrews (Select 0 in Step 8) *3 E6 - Rotating male and female polarized jackscrew (Select 0 in Step 8) *3 T - Fixed male and female jackscrews (Select 0 in Step 8) *3 T6 - Fixed male and female polarized jackscrew (Select 0 in Step 8) STEP 7 - 2ND CONNECTOR GENDER M - Male *5 STEP 6 - 2ND CONNECTOR VARIANT Select same variant as chosen in STEP 2. NOTES *1 Male option in Step 3 available only on connector variants 5W1, 3W3, 7W2, STEP 5 - 1 CONNECTOR SHELL OPTION ST 0- *4 S - X- Z- Zinc Plated, with Chromate Seal. Stainless Steel, passivated. Tin Plated. Tin Plated and Dimpled (male connectors only). 11W1,17W2, 21W1, 21WA4, 27W2, 24W7, 46W4. *2 Connector mating style for both connectors must be the same if 0 or S is used. If E, E6, T or T6 is used in either Step 4 or 8 the other step must be 0. *3 For hardware information, see page 59. *4 For stainless steel dimpled male versions, contact Technical Sales. *5 Connector variant for both connectors must be the same. DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. 60 CONNECTOR SAVERS STEP