General Purpose Fuses IEC General Purpose Fuses IEC Ferrule Fuses aM & gG 400V to 690V with/without Striker aM & gG 8x32, 10x38, 14x51, 22x58 Residential and Industrial Cylindrical Fuse-links Ferraz Shawmut gF/gG-gG and aM fuse-links cover a wide range of physical sizes and ampere ratings for 250, 380*/ 400, 500, and 660* 690volts AC. gF/gG fuse-links are for residential use. gG and aM fuse-links are for industrial applications. Most ratings are available with an optional indicator. All industrial fuse-links have the option of a built-in striker. All cylindrical fuse-links have ceramic bodies and silver-plated ferrules. * Fuse-links marked 380V (gF/gG) and 660V (gG-aM) will be re-marked (and safely used at ) 400V AC and 690V AC in compliance with changes in IEC Standard 269, but should not be used above 418V AC or 726V AC. gF/gG gG gG aM Residential Full Range Protection Full Range Protection Full Range Protection Short Circuit Short Circuit Protection Protection Fuse-links with striker * 4 physical sizes from 8 x 31 mm to 22 x 58 mm * 7 physical sizes from 6.3 x 23mm to 10.3 x 38 mm * 4 physical sizes from 8 x 31mm to 22 x 58 mm * 250 and 380 Volt * 400, 500 and 690 ratings - 0.5A through 32A * Most ratings available with indicator * Meet IEC, NFC, UNE standards * See residential fuse-links, Special Purpose section Volt ratings -0.5A through 125A * Most ratings available with indicator * Meet IEC, NFC and UNE standards * Approved by Lloyds Register of Shipping and Bureau Veritas * 2 sizes14 x 51mm * 400, 500 and and 22 x 58 mm 690 Volt ratings0.16A through * 400, 500 and 125A 690 Volt ratings 4A through 125A * All ratings include striker * Most ratings available with indicator * Meet IEC, NFC and UNE standards * Meet IEC, NFC and UNE standards * Approved by * Approved by Lloyds Register of Shipping and Bureau Veritas Lloyds Register of Shipping and Bureau Veritas GPEU2 aM Fuse-links with striker * 2 sizes 14 x 51mm and 22 x 58mm * 400, 500 and 690 Volt ratings - 2A through 125A * All ratings include striker * Meet IEC, NFC and UNE standards * Approved by Lloyds Register of Shipping and Bureau Veritas General Purpose Fuses IEC General Purpose Fuses IEC Ferrule Fuses aM 400V to 690V with/without Striker aM 8x32, 10x38, 14x51, 22x58 Ratings - aM (Optional Blown-Fuse Indicator) Size Rated In (mm x mm) Current (A) 1 S219229 8 x 31 F214618 10 X 38 Q217686 14 X 51 C215650 22 x 58 Packaging 10 2 4 6 8 10 0.16 0.25 0.5 1 2 4 6 8 10 12 16 20 25 32 0.25 0.5 1 2 4 6 8 10 12 16 20 25 32 40 45 50 1 2 4 6 8 10 12 16 20 25 32 40 50 63 80 100 125 Rated Previous Reference Reference Number w w/o w Voltage w/o Indicator Indicator Indicator Indicator 15511 C217168 15513 R218193 15519 S219229 400V 15523 C222205 15527 F200749 15531 W201292 16503 E214617 16507 M215130 16509 W216150 16511 16711 F217171 X219233 16513 16713 H218714 G222209 16519 16719 W219232 K200753 16523 16723 F222208 K201811 500V 16527 16727 Z201295 Z211553 16531 16731 Y211552 H213102 16533 16733 A213601 D214110 16535 16735 F214618 P215132 16537 16737 X216151 V216655 400V 16539 16739 G217172 L217682 400V 16543 J218715 17507 B212590 17509 L213105 17511 17711 E213605 C212591 17513 17713 H214114 M213106 17519 17719 K214622 J214115 17523 17723 S215135 T215136 17527 17727 T215642 A216660 17531 17731 Z216659 R217687 690V 17533 17733 M217177 Q218721 17535 17735 Q217686 F219770 17537 17737 P218720 R200759 17539 17739 E219769 Q201816 17543 17743 M222214 F211559 500V 17547 17747 Q200758 D212592 17549 17749 L211035 G213607 400V 17551 17751 E211558 M214624 18511 M219776 18513 T222220 18519 18719 Q222976 L219246 18523 18723 Y200765 V222221 18527 18727 N201308 Y201823 18531 18731 X201822 N211566 18533 18731 T211042 K212598 18535 18735 M211565 P213614 690V 18537 18737 S212076 V214631 18539 18739 J212597 D215651 18543 18743 V213113 J216668 18547 18747 N213613 Z217694 18551 18751 R214122 P219778 18555 18755 C215650 Z200766 18559 18759 H216667 P211567 500V 18563 18763 Y217693 L212599 400V 18565 18765 J218209 W214632 Blown-Fuse Indicator BEFORE Breaking Capacity 20kA - 400V 120kA - 500V 120kA - 400V 120kA - 400V 80kA - 690V 120kA - 500V 120kA - 400V 80kA - 690V 120kA - 500V 120kA - 400V Catalog Number w/o w Indicator Indicator FR8AM40V1 FR8AM40V2 FR8AM40V4 FR8AM40V6 FR8AM40V8 FR8AM40V10 FR10AM50V0.16 FR10AM50V0.25 FR10AM50V0.5 FR10AM50V1 FR10AM50V1I FR10AM50V2 FR10AM50V2I FR10AM50V4 FR10AM50V4I FR10AM50V6 FR10AM50V6I FR10AM50V10 FR10AM50V10I FR10AM50V10 FR10AM50V10I FR10AM50V12 FR10AM50V12I FR10AM50V16 FR10AM50V16I FR10AM50V20 FR10AM50V20I FR10AM50V25 FR10AM50V25I FR10AM50V32 FR14AM69V0.25 FR14AM69V0.5 FR14AM69V1 FR14AM69V1I FR14AM69V2 FR14AM69V2I FR14AM69V4 FR14AM69V4I FR14AM69V6 FR14AM69V6I FR14AM69V8 FR14AM69V8I FR14AM69V10 FR14AM69V10I FR14AM69V12 FR14AM69V12I FR14AM69V16 FR14AM69V16I FR14AM69V20 FR14AM69V20I FR14AM69V25 FR14AM69V25I FR14AM69V32 FR14AM69V32I FR14AM69V40 FR14AM69V40I FR14AM69V45 FR14AM69V45I FR14AM69V50 FR14AM69V50I FR22AM69V1 FR22AM69V2 FR22AM69V4 FR22AM69V4I FR22AM69V6 FR22AM69V6I FR22AM69V8 FR22AM69V8I FR22AM69V10 FR22AM69V10I FR22AM69V12 FR22AM69V12I FR22AM69V16 FR22AM69V16I FR22AM69V20 FR22AM69V20I FR22AM69V25 FR22AM69V25I FR22AM69V32 FR22AM69V32I FR22AM69V40 FR22AM69V40I FR22AM69V50 FR22AM69V50I FR22AM69V63 FR22AM69V63I FR22AM69V80 FR22AM69V80I FR22AM69V100 FR22AM69V100I FR22AM69V125 FR22AM69V125I Dimensions AFTER GPEC8 FUSE SIZE A B C 8 x 31 10 x 38 14 x 51 22 x 58 8.5 10.3 14.3 22.2 31.5 38 51 58 6.3 10.5 13.8 16.2 General Purpose Fuses IEC General Purpose Fuses IEC Ferrule Fuses aM 400V to 690V with/without Striker aM 8x32, 10x38, 14x51, 22x58 Ratings - aM with Striker Size Rated (mm x mm) Current In (A) 1 2 4 6 8 10 12 16 20 25 32 40 45 50 1 2 4 6 8 10 12 16 20 25 32 40 50 63 80 100 125 14 X 51 X215645 K216669 22 X 58 Rated Previous Reference Voltage Reference Number 500V 400V 690V 500V 400V 17911 17913 17919 17923 17927 17931 17933 17935 17937 17939 17943 17947 17949 17951 18911 18913 18919 18923 18927 18931 18933 18935 18937 18939 18943 18947 18951 18955 18959 18963 18965 Breaking Capacity Catalog Number. W215644 B216661 C218203 E219240 N222215 S200760 R201817 120kA 500V G211560 E212593 H213608 N214625 X215645 C216662 D218204 120kA - 400V E215652 J216162 A217695 Y218728 Q219779 S222978 R201311 W211044 W212079 80kA - 690V Q213615 X214633 F215653 K216669 B217696 Z218729 120kA - 500V T222979 S201312 120kA - 400V FR14AM69V1P FR14AM69V2P FR14AM69V4P FR14AM69V6P FR14AM69V8P FR14AM69V10P FR14AM69V12P FR14AM69V16P FR14AM69V20P FR14AM69V25P FR14AM69V32P FR14AM69V40P FR14AM69V45P FR14AM69V50P FR22AM69V1P FR22AM69V2P FR22AM69V4P FR22AM69V6P FR22AM69V8P FR22AM69V10P FR22AM69V12P FR22AM69V16P FR22AM69V20P FR22AM69V25P FR22AM69V32P FR22AM69V40P FR22AM69V50P FR22AM69V63P FR22AM69V80P FR22AM69V100P FR22AM69V125P Packaging 10 Striker Dimensions Fuse Size A B C D E 14 x 51 22 x 58 14.3 22.2 51 58 13.8 16.2 7.5 7.5 3.8 3.8 BEFORE AFTER Neutral Size Previous Reference Standard (mm x mm) Reference Number Pack/CTN 10 x 38 14 x 51 22 x 58 GPEU9 19100 19200 19300 R211569 M212600 R213616 10 Catalog Number FRN1038 FRN1451 FRN2258 General Purpose Fuses IEC General Purpose Fuses IEC Ferrule Fuses aM 400V to 690V with/without Striker aM 8x32, 10x38, 14x51, 22x58 Characteristics t-l PREARCING TIME T(S) aM PROSPECTIVE CURRENT (A rms) MAXIMUM VALUE OF CURRENT (KA PEAK) Cut-off characteristics PROSPECTIVE CURRENT (kA rms) GPEU10 General Purpose Fuses IEC General Purpose Fuses IEC Ferrule Fuses gG 400V to 690V with/without Striker aM 8x32, 10x38, 14x51, 22x58 I2T VALUE (A2S) Characteristics I2t aM } - OPERATING I2T { - PREARCING I2T 690 V 500 V 400 V RATED CURRENT (A) Temperature increase table (testing in superior contact) C 80 70 60 50 40 30 20 10 1 2 4 6 8 10 12 16 20 25 32 10 x 38 1 2 4 6 8 10 12 16 20 25 32 40 50 14 x 51 1 2 4 6 8 10 12 16 20 25 32 40 50 63 80 100 125 22 x 58 GPEU11 In General Purpose Fuses IEC General Purpose Fuses IEC Ferrule Fuses aM 400V to 690V with/without Striker aM 8x32, 10x38, 14x51, 22x58 Power loss table Size In 10 x 38 Maximum standardized power low. 14 x 51 22 x 58 0,16 A 0,35 W 0,25 A 0,50 W 0,70 W 0,5 A 0,50 W 0,75 W 1A 0,13 W 0,18 W 0,20 W 2A 0,20 W 0,25 W 0,30 W 4A 0,30 W 0,40 W 0,50 W 6A 0,45 W 0,55 W 0,65 W 8A 0,55 W 0,65 W 0,75 W 10 A 0,65 W 0,75 W 0,85 W 12 A 0,75 W 0,85 W 1W 16 A 0,90 W 1,20 W 1,40 W 20 A 1,10 W 1,50 W 1,70 W 25 A 1,40 W 1,80 W 2W 32 A 2W 2,10 W 2,60 W 40 A 2,60 W 3,20 W 45 A 2,80 W 50 A 2,90 W 3,90 W 63 A 4,60 W 80 A 5,60 W 100 A 6,50 W 125 A 9,50 W IEC 269-2-1 NFC 63.213 UNE 21.103-2-1 10 x 38 14 x 51 22 x 58 16 A 50 A 100 A 1,2 W 3W 7W Table of maximum length of network in function of In and conductor section. Maximum standardized power low. aM Class Fuses Copper conductor section (mm2) 1,5 2,5 4 6 10 16 25 35 Rated Current (In) OF aM Fuses (in A) 16 20 25 32 40 50 63 80 55/64 116 181 273 37/45 84/94 147 223 25/30 58/68 118 178 15/20 40/49 84/95 139 227 26/32 58/68 105/117 181 17/20 42/48 79/89 147 236 28/33 55/64 113/125 189 18/23 37/42 80/94 151 231 GPEU12 100 125 26/31 57/69 120 185 262 14/20 40/47 83/97 147 210