UNIPOLE & MULTIPOLE
CONNECTORS
No reproduction or use without express permission of editorial or pictorial content, in any manner. Printed in Switzerland, 2010  © LEMO SA
LEMO reserve the right at all times to modify and improve specifications without any notification. Pdf updated, June 2016
1www.lemo.com
®®
LEMO unipole and multipole connectors
Table of Contents
This catalogue gives the complete description of LEMO unipole and multipole type connectors. The LEMO manufacturing
programme has been extended to almost 40 series divided into 7 product families with specific mating and environmental
characteristics. Each series includes a wide variety of plug, socket, coupler and bridge plug models, available in contact
configurations adapted to all round cables, including up to 106 conductors, and a maximum diameter of 30 mm.
Watertight and vacuumtight models are also available. Since LEMO connectors are perfectly screened and designed to
guarantee very low resistance to shell electrical continuity, they are particularly adapted to applications where electro-
magnetic compatibility (EMC) is important.
3 steps to select the right connector ................................................................................................................................................................................3
B Series (indoor, keyed)
Part Numbering system .........................................................................................................................................................................................11
Metal Housing models............................................................................................................................................................................................12
Elbow socket models..............................................................................................................................................................................................22
Plastic housing models...........................................................................................................................................................................................24
Watertight and vacuumtight models .......................................................................................................................................................................26
Bridge models ........................................................................................................................................................................................................29
Threaded-latching models......................................................................................................................................................................................30
Alignment Key and Polarized Keying System ........................................................................................................................................................31
K Series (outdoor, keyed)
Part Numbering system..........................................................................................................................................................................................33
Metal Housing models............................................................................................................................................................................................34
Watertight and vacuumtight models .......................................................................................................................................................................41
Alignment Key and Polarized Keying System ........................................................................................................................................................43
B and K Series
Insert configuration, Housings, Insulators, Contacts .................................................................................................................................45
S Series (indoor, stepped insert)
Part Numbering system .........................................................................................................................................................................................57
Metal Housing models............................................................................................................................................................................................58
Elbow socket models..............................................................................................................................................................................................68
Plastic housing models...........................................................................................................................................................................................70
E Series (outdoor, stepped insert)
Part Numbering system..........................................................................................................................................................................................75
Metal Housing models............................................................................................................................................................................................76
Watertight and vacuumtight models .......................................................................................................................................................................82
L Series (outdoor, stepped insert)
Part Numbering system..........................................................................................................................................................................................85
Metal Housing models............................................................................................................................................................................................86
Vacuumtight models...............................................................................................................................................................................................89
Alignment Key and Polarized Keying System ........................................................................................................................................................90
S, E and L Series
Insert configuration, Housings, Insulators, Contacts .................................................................................................................................91
2G Series (indoor, keyed)...............................................................................................................................................................................................110
2C Series (indoor, stepped insert).................................................................................................................................................................................116
1D Series (indoor, 4 concentric contacts) ....................................................................................................................................................................124
Spare parts ......................................................................................................................................................................................................................130
Accessories .....................................................................................................................................................................................................................136
Tooling .............................................................................................................................................................................................................................146
Panel cut-outs .................................................................................................................................................................................................................152
PCB drilling pattern ........................................................................................................................................................................................................154
Cable assembly (B, K, S and E series) ...........................................................................................................................................................................161
Technical characteristics ...............................................................................................................................................................................................171
2
®
®
www.lemo.com
Precision modular connectors to suit your application
Since it’s creation in Switzerland in 1946 the LEMO Group has been recognized as a global leader of circular Push-Pull
connectors and connector solutions. Today LEMO and its affiliated companies, REDEL and COELVER, are active in
more than 80 countries with the help of over 40 subsidiaries and distributors.
Over 75’000 connectors
The modular design of the LEMO range provides over 75’000 connectors from miniature ø 3 mm to ø 50 mm, capable of
handling cable diameters up to 30 mm and for up to 106 contacts.
This vast portfolio enables you to select the ideal connector configuration to suit almost any specific requirement in most
markets, including medical devices, test and measurement instruments, machinery, audio video broadcast, telecommuni-
cations and military.
LEMO’s Push-Pull Self-Latching Connection System
The LEMO self-latching system allows the connector
to be mated by simply pushing the plug axially into the
socket.
This self-latching system is renowned worldwide for its easy and quick mating and unmating features. It provides absolute
security against vibration, shock or pull on the cable, and facilitates operation in a very limited space.
UL Recognition
LEMO connectors are recognized by the Underwriters Laboratories (UL). The approval of the complete system (LEMO
connector, cable and your equipment) will be easier because LEMO connectors are recognized.
CE marking
CE marking means that the appliance or equipment bearing it complies with the protection requirements of one or
several European safety directives. CE marking applies to complete products or equipment, but not to electrome-
chanical components, such as connectors.
RoHS
LEMO connector specifications conforms the requirements of the RoHS directive (2011/65/EU) of the European Parlia-
ment and the latest amendments. This directive specifies the restrictions of the use of hazardous substances in electrical
and electronic equipment marketed in Europe.
Once firmly latched, connection cannot be broken by
pulling on the cable or any other component part other
than the outer release sleeve.
When required, the connector is disengaged by a
single axial pull on the outer release sleeve. This first
disengages the latches and then withdraws the plug
from the socket.
.
.. .
.. .
..
3www.lemo.com
®®
Step 1: Select connector series
Select the appropriate LEMO connector series according to the environmental parameters that will affect your device
or cable such as indoor, outdoor, temperature range, ingress protection of the mated connector and of your device.
Use the table shown on page 4.
Part number coding
B, K, S, E, L, G, C or D
Step 2: Select connector size
Use the section (mm2) or the AWG of your cable wire to select the optimal contact diameter (values vary between
solder, crimp or print contact), see page 7.
Use this optimal contact diameter to determine the right connector size as well as the insert configuration, see page 6.
0, 1, 2, 3, 4, 5 or 6
Step 3: Complete the part number
Now that you know the series, as well as the insulator configuration, complete the part numbering system with the help
of the following table.
Model Series Contact Collet Variant
Housing
material
Insert
configuration Insulator
material
12 12 45 50 50 50 52 54
34 34 45 50 50 50 53 54
58 58 91 99 99 99 102 107
76 76 91 99 99 99 105 107
86 86 92 99 99 99 106 107
111 111 112 112 110 113 113 113
117 117 120 120 116 120 121 121
125 125 127 127 124 127 127 128
B Series (indoor, keyed)
K Series (outdoor, keyed)
S Series (indoor, stepped insert)
E Series (outdoor, stepped insert)
L Series (outdoor, keyed, stepped insert)
G Series (indoor, keyed)
C Series (indoor, stepped insert)
D Series (indoor, 4 concentric contacts)
3 steps to select the right connector
Note: Figures in the above table refer to the catalogue pages.
Part number coding
Part number coding
4
®®
www.lemo.com
Series
Environment
Ingress 1)
protection
Ingress 2)
protection
Temperature
range
Latching
Shell sizes
Insulator type
Contact type
Features
Page
00 multipole
BK00 unipole
SE C D
Solder, crimp or print Solder, crimp
or print
Solder, crimp or print Solder
Push-Pull self-latching
7 metal
and 4 plastic 6 metal 7 metal
and 5 plastic 6 metal 4 metal 1 metal
Multipole Multipole
L
9 to 31 32 to 44 55 to 73 74 to 83 116 to 122
G
Solder or print
3 metal
109 to 115 123 to 12884 to 90
Multipole
hermaphroditic Quadrax
Unipole or multipole
hermaphroditic
indoor indoor outdoor or harsh environment
IP50 IP66 to IP68 IP50 IP66 to IP68
- 55 to 250°C - 55 to 200°C - 55 to 250°C - 55 to 200°C - 40 to 120°C
indoor
IP50
IP50 to IP68
vacuumtight IP66 to IP68
vacuumtight IP50 to IP68
vacuumtight IP66 to IP68
vacuumtight IP50 IP50
IP50 to IP68
vacuumtight
- 55 to 250°C
13 keyways 9 keyways Stepped insert Stepped
insert 4 concentric
contacts
Stepped
insert 1 keyway
Multipole
hermaphroditic
LEMO unipole and multipole connectors
The standard keyed Series (B, 00, G)
The characteristic feature of these connector series is a keying system which allows higher contact density and prevents
all errors in alignment. The various keying alternatives prevent unwanted cross mating of otherwise similar connectors. It
is also possible to use crimp contacts to reduce cable assembly time. These connector series, include the 0B to 5B range
as well as the 00 multipole and 2G (shortened version of the 2B series), some vacuumtight models are also available.
The watertight keyed Series (K, L)
These series are watertight when mated and assembled to an appropriate cable. They include the 0K to 5K series, avail-
able in the same types as the 0B to 5B series, and the 0L to 2L series with keying and hermaphroditic insulator.
The standard Series (S, 00, C, D)
The characteristic feature of these connector series is the hermaphroditic insulator in the multipole version. They include
principally the 0S to 6S series, as well as the 00 unipole series, the 2C (shortened version) and the 1D quadrax type
(with 4 concentric contacts).
The watertight Series (E)
These series are watertight when mated and assembled to an appropriate cable. They include the 0E to 6E series and
are available in the same types as the S series.
outdoor or
harsh env.
Note:
1) Mated connector. See ingress protection code page 5.
2) Your device. For selection of connectors for watertight and vacuumtight devices, see page 5.
Step 1: Select Connector Series
5www.lemo.com
®®
Selection of connectors for watertight or vacuumtight devices
LEMO B and S series are rated IP50 only when mated. LEMO E, K and L series are rated IP66 (and over) only when
mated. If a device must be watertight or vacuumtight when the connectors are unmated, it is important to select a watertight
or vacuumtight socket. You can consider the following two situations:
Fig. 1 Fig. 2
FGG plug K series
EGG socket K series
FGG plug B series
HGG socket B series
epoxy
resin seal
your device
Definition of Ingress Protection (IP code)
IEC 60529 outlines an international classification system
for the sealing effectiveness of enclosures of electrical
equipment against the intrusion into the equipment of for-
eign bodies (i.e. tools, dust, fingers) and moisture. This
classification system utilizes the letters «IP» (Ingress Pro-
tection) followed by two digits.
Example: IP 50 = IP 50
IP letter code
1st digit
2nd digit
Degrees of protection - First digit
The first digit of the IP code indicates the degree to which
persons are protected against contact with moving parts
and the degree that equipment is protected against solid
foreign bodies intruding into an enclosure.
Degrees of protection - Second digit
The second digit indicates the degree of protection of the
equipment inside the enclosure against the harmful entry
of various forms of moisture (e.g. dripping, spraying, sub-
mersion, etc.)
First digit description
Code
No special protection
Protection from a large part of the body such as hand
or from solid objects greater than 50 mm in diameter
Protection against objects not greater than 80 mm in length
and 12 mm in diameter
Protection from entry by tools, wires, etc.,
with a diameter or thickness greater than 2.5 mm
Protection from entry by solid objects
with a diameter or thickness greater than 1.0 mm
Protection from the amount of dust that would interfere
with the operation of the equipment
Dust-tight
0
1
2
3
4
5
6
7
8
Second digit description
Code
No special protection
Protection from vertically dripping water
Protection from dripping water when tilted up to 15°
Protection from sprayed water
Protection from splashed water
Protection from water projected from a nozzle
Protection against heavy seas, or powerful jets of water
Protection against temporary immersion
Protection against complete continuous submersion in water
0
1
2
3
4
5
6
7
8
your device
A) Figure 1 shows a typical outdoor device. To ensure this
device retains IP66 or above when connectors are
unmated, it is important to choose a watertight socket
from B, S, E, K or L series.
B) Figure 2 shows a device which is subjected to pressure
difference such as a near vacuum or pressurized gas
and must exhibit no leakage. To ensure the device
maintains its sealing, the socket is additionally tested for
helium leakage (according MIL 1344A).
Check temperature range (see section on pages 26, 41, 72, 82 and 89).
0.5 0.9 1.3 2.0 3.0 6.0 0.9 1.3 1.6 2.0 4.0 6.0 1.6
0.5 0.9 1.3 1.6 2.0 0.7 0.9 1.3 2.0 3.0 6.0/4.0 6.0 1.3
0.5 0.7 0.9 1.3 2.0 3.0 4.0 0.7 0.9 1.3 2.0 3.0 4.0 8.0 1.3 0.6
0.35 0.7 0.9 1.3 1.6 0.9/0.7 1.3 2.0/1.3 3.0/2.0 4.0/3.0
0.5 0.7 1.3 1.6 2.0 0.7 1.3 1.3 2.0 3.0 1.3
0.5 0.7 1.3 1.6 2.0 1.3/0.9 1.3 2.0/1.3
0.7 0.9 1.3 0.9 1.3 1.3 3.0 0.7
0.5 1.3/2.0 1.3
0.5 0.9 1.3 1.6 3.0 0.9 1.3 1.3 2.0 0.7
0.35 0.7 0.9 1.3 0.9 1.3 2.0 4.0/5.0 0.7
0.9 1.3
0.5 0.7 0.9 2.0 0.9 1.3 3.0/2.0 0.7
0.5 0.7 0.9 0.9 2.0 0.9 0.9 2.0 3.0
0.7 0.9 0.9 0.9 3.0/1.6 4.0 0.7
0.7
0.7 0.9 1.6 0.9 1.6 3.0
0.7 0.9 3.0/1.6
0.7 0.9 0.9 1.6 3.0
0.5 0.7
0.7 0.9 1.3 1.3 2.0
0.5 2.0
1.3 2.0 2)
0.7 1.3 1.3 2.0
1.3
0.7 1.3 1.3 2.0
0.9
0.9
1.6
1.6
0.9 1.3
1.3
0.9
6
®®
www.lemo.com
Number of contacts
00
0B-0K
1B-1K
2B-2K
3B-3K
4B-4K
5B-5K
00
0S-0E-0L1)
1S-1E-1L1)
2S-2E-2L1)
3S-3E
4S-4E
5S-5E
6S-6E
2G
2C
1D (ø C)
1.3
1.6
2.0
3.0 3.0
4.0 4.0 4.0
6.0 6.0
12.0
1
1
1
1
1
1
1
Series
Insert configuration
113
116
120
130
140
160
112
302
303
304
305
306
307
308
309
310
312
313
314
316
318
319
320
322
324
326
330
332
336
340
344
348
350
354
360
362
364
372
106
Select the right connector size and insert configuration
To be able to select the right connector size (0 to 6), it is important to define the contact diameter (ø A).
Find out the available contact diameter A) of the LEMO connector depending on the number of contacts required and
depending on the rating required (see pages 45 to 49 and 91 to 98).
The following table shows the contact diameter (ø A), or the solder pot diameter (ø C) for the 1D series.
Note: 1) L series not available in unipole version. 2) 2.0 is for 6S series, for 6E the values are 1.3 and 5.0.
Step 2: Select Connector Size
2
3
4
5
6
7
8
9
10
12
13
14
16
18
19
20
22
24
26
30
32
36
40
44
48
50
54
60
62
64
72
106
Unipole
Multipole
7www.lemo.com
®
®
Verify if the selected contact diameter (ø A) of the LEMO connector fits to your cable wire diameter (AWG number or
max. available section).
Conductor
Solid Stranded
AWG Section (mm2)
min. max. min. max.
Fr1)
(N)
AWG
max.
Section
max.
(mm2)
Contact
ø A ø C Form
(mm) (mm) per fig.
0.55) 0.45 1
0.80 1
0.7
0.45 2
1.10 1
0.9 0.80 2
0.45 2
1.40 1
1.3 1.10 2
0.80 2
1.90 1
1.6
1.40 2
2.40 1
2.0
1.90 2
3.0 3.20 1
4.0 4.00 1
Note
ø A
ø C
ø A
ø C
Contact type
32 28 0.035 0.09 12
26 224) 0.140 0.34
22
32 28 0.035 0.09
24 20 0.250 0.50
26 224) 0.140 0.34 30
32 28 0.035 0.09
20 18 0.500 1.00
24 20 0.250 0.50 40
26 224) 0.140 0.34
18 144) 1.000 1.50
50
22 18 0.340 1.00
16 124) 1.500 2.50
65
18 14 1.000 1.50
14 104) 2.500 4.00 75
12 10 4.000 6.00 90
L dimensions and C are detailed in the section on PCB drilling pattern.
See page 156 and 159.
L dimensions and C are detailed in the section on PCB drilling pattern.
See page 157 and 160.
ø A
ø A
ø C
ø C
ø A ø C
ø A ø C
ø A ø C
ø C
ø A
L
L
ø C
L
ø A
Note: 1) contact retention force in the insulator (according to IEC 60512-8 test 15 a).
2) for 00 multipole series.
3) for S, E, 2C, 2G and 1D series.
4) for a given AWG, the diameter of some stranded conductor designs is larger than the solder cup diameter. Make sure that the maximum conductor
diameter is smaller than ø C.
5) for 00 multipole series or for 0B and 1B series with male contacts.
6) for 0B.302/0B.303 and 0K.302/0K.303 ø C = 1.0 mm, AWG max 20, section max (mm2) 0.50.
7) for 00 and 1B/1K series, according to manufacturing and plating tolerance ø C min = 0.43 mm.
fig. 1
fig. 2
Solder 28 0.09 30 0.05
28 0.09 30 0.05
28 0.09 28 0.09
24 0.25 26 0.14
22 0.34 224) 0.34
226) 0.346) 224)6) 0.346)
20 0.50 204) 0.50
16 1.00 18 1.00
14 1.50 16 1.50
10 4.00 12 4.00
10 6.00 10 6.00
8 10.00
8 10.00
4 21.00
0 50.00
0.35 0.40
0.52) 0.402)
0.5 0.457)
0.73) 0.603)
0.7 0.80
0.9 0.806)
1.3 1.00
1.6 1.40
2.0 1.80
3.0 2.70
4.0 3.70
5.0 5.20
6.0 5.20
8.0 7.00
12.0 11.50
Verify the fitting to your wire
Crimp
Print
Print (elbow)
1.1 4.1 1.1 4.1
1.3 6.7 1.3 6.1
1.3 8.5 1.3 8.0
1.3 10.5 1.3 10.0
2.5 13.0 2.5 13.0
4.1 22.0 4.1 13.0
6.1 30.0
11.1 30.0
1.0 5.0 1.0 5.0
1.3 8.53) 1.3 8.5
1.3 10.53) 1.3 10.5
2.6 15.03) 2.6 15.0
4.6 23.53) 4.6 15.0
9.6 23.5
13.0 30.0
8
®®
www.lemo.com
Cable diameter range (mm)
Collet for fitting
Collet a bend relief
min. max. min. max.
Series
001)
0B
1B
2B
3B
4B
5B
0K
1K
2K
3K
4K
5K
Note:
1) for multipole only.
2) for unipole only.
3) for these series the maximum cable diameter require models with oversized cable collet (type K).
1.1 3.4 1.1 3.4
1.5 5.5 1.5 5.0
2.2 7.5 2.2 7.0
1.5 9.7 1.5 9.0
4.1 11.7 4.1 11.0
5.1 16.0 5.1 15.0
9.6 25.0 9.6 15.5
1.0 5.0 1.0 5.0
1.3 8.53) 1.3 8.5
1.3 10.53) 1.3 10.5
2.6 15.03) 2.6 15.0
4.6 23.53) 4.6 15.0
9.6 23.5
Cable diameter range (mm)
Collet for fitting
Collet a bend relief
min. max. min. max.
Series
002)
0S
1S
2S
3S
4S
5S
6S
0E
1E
2E
3E
4E
5E
6E
0L
1L
2L
1.0 5.0 1.0 5.0
1.3 8.53) 1.3 8.5
1.3 10.53) 1.3 10.5
2C
2G
1D
2.2 8.1 2.2 8.1
4.5 7.9 4.5 7.9
3.1 7.5 3.1 7.0
Cable diameter range (mm)
Collet for fitting
Collet a bend relief
min. max. min. max.
Series
Verify if the selected connector size fits to your cable diameter.
Verify the fitting to your cable
K SERIES (watertight)
B SERIES
FIG
FGG
FFG
FGG
FEG
FNG
JGG
FDG
EJG
R

EPG
EZG
CFF, CRG
PHG
PHG
PNG
FGGFGG
FGY
FGY
FTG
ENG
ENY
FAG
FWG EGG
EHG
EKG
ENG
ESG
EEG
ECG
EFG
ECG
ECG
EYG
XPF
XBG, EXG
PEG
PKG
PFG
S

YHG
HCG
HGG HHG
HNG HMG
HEG FVG
FVB
ESG
XRB
FHG
FKG
FPG
FMG
B Series
B series connectors provide the following main features:
security of the Push-Pull self-latching system multipole types 2 to 64 contacts
solder, crimp or print contacts (straight or elbow) – high packing density for space savings
multiple key options to avoid cross mating keying system («G» key standard)
of similar connectors for connector alignment
360° screening for full EMC shielding.
Fixed plugs Straight plugs Fixed sockets Free sockets
Elbow plugs
Fixed sockets
Fixed coupler
Fixed socketsStraight plugs
Elbow sockets
Bridge plugsPlug with two
parallel sockets
Plastic housing models (page 24)
Metal housing models (page 12)
Bridge models (page 29)
Elbow socket models (page 22)
Fixed
plug
Fixed sockets Fixed
coupler
Watertight or vacuumtight models (page 26)
Straight plugs Fixed socket
Elbow socket
Threaded-latching models (page 30)
10 www.lemo.com
®
®
1
345
2
6
7
4
3
6
7
5
2
1
4
3
6
5
7
2
1
1654273
11www.lemo.com
®
®
Z
FG G 1B
Insert configuration: (page 45)
Cable ø: (page 52)
Collet type: (page 52)
Variant: (page 54)
306
Series: (page 12)
Model: (page 12)
Alignment key: (page 31)
CLAD62
Fixed socket EG G 1B 306 CYM
Housing: (page 50)
Insulator: (page 50)
Contact: (page 50)
Variant: (page 54)
Coupler RJ G 1B 306 CLA
Part Numbering System
Plug
PH G 1B 306 CLLD62
Free socket
.. .
.. .
.. .
.. .
Fixed socket:
EGG.1B.306.CYM = fixed socket, nut fixing, with key (G), 1B series, multipole type with 6 contacts, outer shell in chrome-
plated brass, PEEK extended insulator, female crimp contacts.
Part Section Showing Internal Components
Fixed socket
outer shell
earthing crown
retaining ring
hexagonal nut
locking washer
insulator
female contact
Straight plug
outer shell
latch sleeve
collet nut
split insert carrier
insulator
male contact
collet
Fixed coupler:
RJG.1B.306.CLA = straight fixed coupler with keys (J) at the flange end and key (G) at the other end, 1B series, multipole
type with 6 contacts, outer shell in chrome-plated brass, PEEK insulator, male-female contacts.
Part Number Example
Free socket:
PHG.1B.306.CLLD62Z = free socket with key (G) and cable collet, 1B series, multipole type with 6 contacts, outer shell
in chrome-plated brass, PEEK insulator, female solder contacts, D type collet for 6.0 mm diameter cable and nut for fitting
a bend relief.
Straight plug with cable collet:
FGG.1B.306.CLAD62 = straight plug with key (G) and cable collet, 1B series, multipole type with 6 contacts, outer shell in
chrome-plated brass, PEEK insulator, male solder contacts, D type collet for 6.0 mm diameter cable.
12 www.lemo.com
®®
JGG Straight plug, short version, key (G),
cable collet
9.5 32.0 22.0 8.0 7
Reference
Model Series
Dimensions (mm)
ALMS1 S2
JGG 0B
~M
~L
ø A
S 1
S 2
FGG Straight plug, key (G) or keys
(A…M and R), cable collet
Reference
Model Series
S 2
~M
~L
S 1
ø A
FGG 001)
FGG 0B
FGG 1B
FGG 2B
FGG 3B
FGG 4B
FGG 5B
6.4 28.5 20.5 5.5 5
9.5 36.0 26.0 8.0 7
12.0 43.0 32.0 10.0 9
15.0 50.0 38.0 13.0 12
18.0 58.0 43.0 15.0 14
25.0 75.0 57.0 21.0 20
35.0 103.0 78.0 31.0 30
Dimensions (mm)
ALMS1 S2
FGG Straight plug, key (G) or keys (A…M),
cable collet and nut for fitting a bend relief 2)
Reference
Model Series
FGG 001)
FGG 0B
FGG 1B
FGG 2B
FGG 3B
FGG 4B
6.4 28.7 20.7 5.5 6
9.5 35.0 25.0 8.0 7
12.0 42.0 31.0 10.0 9
15.0 49.0 37.0 13.0 12
18.0 56.5 41.5 15.0 15
25.0 71.0 53.0 21.0 20
Dimensions (mm)
ALMS1 S2
Note: 1) the surface design of the 00 series is different.
2) to order, add a «Z» at the end of the reference.
The bend relief must be ordered separately (see page 141).
Note: 1) the surface design of the 00 series is different.
M4 Cable assembly (page 161)
M1
Cable assembly
(page 161)
M1
Cable assembly
(page 161)
Technical Characteristics
Electrical
at 10 MHz
at 1 GHz
Characteristics
> 75 dB IEC 60169-1-3
> 40 dB IEC 60169-1-3
Value Standard
Shielding
efficiency
Note:
the various tests have been carried out with FGG and EGG connector
pairs, with chrome-plated brass shell and PEEK insulator.
Detailed electrical characteristics, as well as materials and treatment are
presented in the chapter Technical Characteristics on page 171.
> 5000 cycles IEC 60512-5 test 9a
up to 95% at 60° C
- 55° C, +250° C
10-2000 Hz, 15 g IEC 60512-4 test 6d
100 g, 6 ms IEC 60512-4 test 6c
> 1000h IEC 60512-6 test 11f
IP50 IEC 60529
5</