SPECIFICATION
MODEL
HLG-240-12
HLG-240-15
HLG-240-20
HLG-240-24
HLG-240-30
HLG-240-36
HLG-240-48
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE Note.6
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME Note.8
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS Note.7
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT Note.4
OVER VOLTAGE
OVER TEMPERATURE
12V
6 ~12V
15V
7.5 ~ 15V
20V
10 ~ 20V
24V
12 ~ 24V
30V
15 ~ 30V
36V
18 ~ 36V
48V
24 ~ 48V
16A 15A 12A 10A 8A 6.7A 5A
192W 225W 240W 240W 240W 241.2W 240W
150mVp-p 150mVp-p
14 ~ 16V
150mVp-p
18.6 ~ 21.4V
150mVp-p
22.4 ~ 25.6V
200mVp-p
28 ~ 32V
250mVp-p
33.5 ~ 38.5V
250mVp-p
44.8 ~ 51.2V
±2.5%
8 ~ 16A
±2.0%
7.5 ~ 15A
±1.0%
6 ~ 12A
±1.0%
5 ~ 10A
±1.0%
4 ~ 8A
±1.0%
3.3 ~ 6.7A
±1.0%
2.5 ~ 5A
11.2 ~ 12.8V
Can be adjusted by internal potentiometer A type and C type only
±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±2.0% ±1.5% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5%
1000ms,80ms/115VAC 500ms,80ms/230VAC at full load
15ms at full load 230VAC /115VAC
90 ~ 264VAC 127 ~ 373VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC at full load (Please refer to "Power Factor Characteristic" curve)
90% 90% 91.5% 92.5% 92.5% 92.5% 93%
13.5 ~ 18V 17.5 ~ 21.5V 23.5 ~ 27.5V 27 ~ 34V 33 ~ 39V 43 ~ 49V 55 ~ 63V
4A / 115VAC 2A / 230VAC
<0.75mA / 240VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria B
-40 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
±℃ 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
207.9K hrs min. MIL-HDBK-217F (25 )
244.2*68*38.8mm (L*W*H)(HLG-240-Blank/A/B) 251*68*38.8mm (L*W*H)(HLG-240-C)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. A type and C type only.
7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement.
11. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
1.3Kg; 12pcs/16.6Kg/0.84CUFT(HLG-240-Blank/A/B) 1.23Kg; 12pcs/15.8Kg/1.16CUFT(HLG-240-C)
Protection type : Shut down and latch off o/p voltage, re-power on to recover
240W Single Output Switching Power Supply
Universal AC input / Full range
Built-in active PFC function
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
IP67 / IP65 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and street lighting applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
Type HL for use in class , Division 2 hazardous(Classified) location luminaires
7 years warranty (Note.10)
Features :
HLG-240 series
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, recovers automatically after temperature goes down
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
Blank : IP67 rated. Cable for I/O connection.
HLG-240-54
54V
27 ~ 54V
4.45A
240.3W
350mVp-p
50 ~ 57V
±1.0%
2.23 ~ 4.45A
±0.5%
±0.5%
HLG-240-42
42V
21 ~ 42V
5.72A
240.24W
250mVp-p
39 ~ 45V
±1.0%
2.86 ~ 5.72A
±0.5%
±0.5%
92.5% 93.5%
48 ~ 54V 60 ~ 67V
UL1012, CAN/CSA-C22.2 No. 107.1-01, UL8750, CSA C22.2 No. 250.0-08, TUV EN61347-1, EN61347-2-13 independent
(except for HLG-240 C type), UL60950-1, UL8750, TUV EN60950-1, IP65 or IP67, J61347-1, J61347-2-13 approved
EMC IMMUNITY
EMC EMISSION
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
CONSTANT CURRENT REGION
Note.4
HLG-240-12 A
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
C : Terminal block for I/O connection. Output voltage and constant current level can be adjusted through internal
potentiometer.
D (option, safety pending) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
COLD START 75A(t =570 s measured at 50% I ) at 230VACwidth peak
μ
THD< 20% when output loading 50% at 115VAC/230VAC
TOTAL HARMONIC DISTORTION
F
110
SELV
IP65 IP67
Type HL
Bauar
Sicherheit
egel gema
t gepruft
od
be
www.
ID 2000000000
tuv.com
wac g
os
File Name:HLG-240-SPEC 2015-07-22
Mechanical Specification
File Name:HLG-240-SPEC 2015-07-22
Case No.954C Unit:mm
244.2
244.2
220.2
220.2
12
12
9.6
9.6
+V(Red)
+V(Red)
-V(Black)
-V(Black)
300 20±
300 20±
FG (Green/Yellow)
FG (Green/Yellow)
FG (Green/Yellow)
38.8 38.8
AC/L(Brown)
AC/L(Brown)
AC/L(Brown)
AC/N(Blue)
AC/N(Blue)
AC/N(Blue)
9.4 9.4
9.4 9.4
34.2 34.2
68 68
ψ×4.2 4PL
ψ×4.2 4PL
ψ×4.2 4PL
300 20±
300 20±
244.2
220.2
12
9.6
+V(Red)
-V(Black)
DIM-(White)
DIM+(Blue)
SJTW 18AWG 3C×
B Type:(HLG-240-_B)
300 20±
38.8
9.4 9.4
34.2
68
300 20±
SJTW 14AWG 2C×
SJTW 18AWG 2C×
A Type:(HLG-240-_A)
IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
(Can access by removing the rubber stopper on the case.)
IP67 rated. Cable for I/O connection.
SJTW 14AWG 2C×
SJTW 14AWG 2C×
SJTW 18AWG 3C×
SJTW 18AWG 3C×
110.1
110.1
110.1
Tcase
Tcase
Tcase
34
34
34
T case: Max. Case Temperature.
T case: Max. Case Temperature.
T case: Max. Case Temperature.
Vo
ADJ.
Io
ADJ.
240W Single Output Switching Power Supply HLG-240 series
Blank:(HLG-240)
AC Input Terminal Pin No. Assignment DC Output Terminal Pin No. Assignment
Pin No. Pin No.
11
3
22
Assignment Assignment
AC/L +V
-V
AC/N
FG
C Type:(HLG-240-_C)
Output voltage and constant current level can be adjusted through internal potentiometer.
(Can access by removing the rubber stopper on the case.)
110.1
Tcase
34
Vo
ADJ.
Io
ADJ.
T case: Max. Case Temperature.
I/P
8
15.4
1
2
3
88
220.2
251
1
2O/P
ψ×4.2 4PL
38.8
37
68
7.5 9.5
IP67 rated. Timer dimming function, contact MEAN WELL for details.
D Type(option):(HLG-240-_D)
244.2
220.2
12
9.6
+V(Red)
-V(Black)
300 20±
FG (Green/Yellow)
38.8
AC/L(Brown)
AC/N(Blue)
9.4 9.4
34.2
68
ψ×4.2 4PL
300 20±
SJTW 14AWG 2C×
SJTW 18AWG 3C×
110.1
Tcase
34
T case: Max. Case Temperature.
DIM+
(B Type)
DIM-
Fosc : 100KHz
DETECTION
PWM & PFC CIRCUIT
O.L.P.
EMI FILTER
RECTIFIERS
POWER
SWITCHING
FILTER
&
RECTIFIERS +V
-V
I/P
FG
CONTROL
O.V.P.
&
O.L.P.
PFC
CIRCUIT
PFC
CONTROL
Block Diagram
240W Single Output Switching Power Supply HLG-240 series
File Name:HLG-240-SPEC 2015-07-22
66
70
74
78
82
86
90
94
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
230Vac
115Vac
0.78
0.80
0.82
0.84
0.86
0.88
0.90
0.92
0.94
0.96
0.98
1.00
50% 60% 70% 80% 90% 100%
230Vac
115Vac
EFFICIENCY vs LOAD (48V Model)
HLG-240 series possess superior working efficiency that up to 94% can be reached in field applications.
LOAD
EFFICIENCY (%)
EFFICIENCY vs LOAD (48V Model)
Power Factor Characteristic
PF
LOAD
Constant Current Mode
(240W)
240W Single Output Switching Power Supply HLG-240 series
Derating Curve Static Characteristics
INPUT VOLTAGE (V) 60Hz
90 100 125 135 145 155 165 175 180 200 230 264
100
90
80
70
60
50
40
LOAD (%)
AMBIENT TEMPERATURE ( )
LOAD (%)
-40 -25 -10 0 15 30 50 60 70
20
40
60
80
100
(HORIZONTAL)
230VAC
100VAC
File Name:HLG-240-SPEC 2015-07-22
Dimming connection diagram for turning the lighting fixture ON/OFF :
Using a switch and relay can turn ON/OFF the lighting fixture.
Using the built-in dimming function on B-type model can't turn the lighting fixture totally dark. Please refer to the connection method below to
achieve 0% brightness of the lighting fixture connecting to the LED power supply unit.
Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
2.The LED lighting fixture can be turned ON/OFF by the switch.
DIMMING OPERATION (for B-type only)
NFG L
Relay
Blue
Brown
Green/
Yellow AC/L
AC/N
HLG-240
BType
DIM+
DIM-
V(-)
V(+)
Blue
White
Black
Red
Switch Adjuster
10K~100K Ohms resistance
1~10V DC Voltage
10V PWM Signal
LED Lighting Fixture
60KΩ
60%
60%
10KΩ
10K /NΩ20K /NΩ30K /NΩ40K /NΩ50K /NΩ60K /NΩ70K /NΩ80K /NΩ90K /NΩ
100K /NΩ
Single driver
Multiple drivers
(N=driver quantity for synchronized
dimming operation)
1V 4V 7V2V 5V 8V3V 6V 9V 10V
10%
10%
20KΩ
20%
20%
30KΩ
30%
30%
40KΩ
40%
40%
50KΩ
50%
50%
70KΩ
70%
70%
80KΩ
80%
80%
90KΩ100KΩOPEN
OPEN
OPEN
90%
90%
100%
100%
Resistance
value
Dimming value
Percentage of rated current
Percentage of rated current
Built-in 3 in 1 dimming function, IP67 rated. Output constant current level can be adjusted through output cable by connecting a resistance or
1 ~ 10Vdc or 10V PWM signal between DIM+ and DIM-.
Reference resistance value for output current adjustment (Typical)
Please DO NOT connect "DIM-" to "-V".
1 ~ 10V dimming function for output current adjustment (Typical)
60%
60%
10%
10%
20%
20%
30%
30%
40%
40%
50%
50%
70%
70%
80%
80%
90%
90%
100%
100%
Duty value
Percentage of rated current
95%~108%
-----
95%~108%
95%~108%
10V PWM signal for output current adjustment (Typical): Frequency range :100Hz ~ 3KHz
HLG-240
FG (Green/Yellow)
AC/L(Brown)
AC/N(Blue)
+V(Red)
-V(Black)
DIM-(White)
DIM+(Blue)
1.Output constant current level can be adjusted through output cable by connecting a or 1~10Vdc or 10V PWM signal between DIM+ and DIM-.resistance
There are two major kinds of LED drive method "direct drive" and "with LED driver".
A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs.
Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B).
DRIVING METHODS OF LED MODULE
Typical LED power supply I-V curve
Vo(%)
100
50
50 100
(min.)
Io (%)
Constant
Current area
Hiccup
Protection
Constant
Voltage area
(A) (B)
(C)
In the constant current region, the highest voltage at the output of the driver
depends on the configuration of the end systems.
Should there be any compatibility issues, please contact MEAN WELL.
240W Single Output Switching Power Supply HLG-240 series
File Name:HLG-240-SPEC 2015-07-22
Waterproof connector
Waterproof connector can be assembled on the output cable of HLG-240 to operate in dry/wet/damp or outdoor environment.
HLG-240
I/P O/P
LED Lamp
AC
source
Cable Joiner
Junction Box(Option )
Pin Configuration (Female) Pin Configuration (Female)
Size Size
M12 M15
4-PIN
5A/PIN
M12-04Order No. Order No.
10A max.Suitable Current Suitable Current
5-PIN
5A/PIN
M12-05
10A max.
2-PIN
12A/PIN
M15-02
12A max.
Up to four wires can be connected through this cable joiner by
soldering or clamping by tools.
66
26 20
ψ25
CJ04-2 suitable for 18AWG~22AWG
CJ04-1 suitable for 14AWG~16AWG
O/P Wires
LED Lamp
HLG-240
WATERPROOF CONNECTION
CJ04 cable joiner can be purchased independently for user's own assembly.
Optional junction box available for , please contact MEAW WELL for details.A / Blank - type
MEAN WELL order No. : CJ04-1, CJ04-2.
150 20±
3- PF 1/2"
86
76
5
10
38.8
35
2- 5ψ
61
32 8.58.5
6
220.2
382.2
150 20±
3- PF 1/2"
68
SJTW 14AWG 2C×
SJTW 18AWG 3C×
FG (Green/Yellow)
AC/L(Brown)
AC/N(Blue) +V(Red)
-V(Black)
240W Single Output Switching Power Supply HLG-240 series
File Name:HLG-240-SPEC 2015-07-22