Rated Operational Power AC-3 (Pe):
Rated Operational Current AC-15
(Ie):
Rated Short-time Withstand Current
(Icw):
Maximum Breaking Capacity:
Maximum Electrical Switching
Frequency:
Rated Operational Current DC-13
(Ie):
Rated Insulation Voltage (Ui):
Rated Impulse Withstand Voltage
(Uimp):
Maximum Mechanical Switching
Frequency:
Rated Control Circuit Voltage (Uc):
Connecting Capacity-Main Circuit:
Connecting Capacity-Auxiliary
Circuit:
Connecting Capacity-Control Circuit:
Number of Main Contacts NO:
Maximum Operating Altitude
Permissible:
Resistance to Vibrations acc. to IEC
60068-2-6:
Resistance to Shock acc. to IEC
60068-2-27:
(220 / 230 / 240 V) 15 kW
(380 / 400 V) 22 kW
(415 V) 30 kW
(440 V) 30 kW
(500 V) 30 kW
(690 V) 30 kW
(220 / 240 V) 4 A
(24 / 127 V) 6 A
(400 / 440 V) 3 A
(500 V) 2 A
(690 V) 2 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
for 0.1 s 140 A
for 1 s 100 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
AC-1 600 cycles per hour
AC-15 1200 cycles per hour
AC-2 / AC-4 150 cycles per hour
AC-3 1200 cycles per hour
DC-13 900 cycles per hour
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(24 V) 6 A / 144 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(48 V) 2.8 A / 134 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
(72 V) 1 A / 72 W
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Flexible with Insulated Ferrule 1/2x 4...35 mm²
Flexible with Ferrule 1/2x 4...35 mm²
Rigid 1/2x 6...35 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid 1/2x 1...2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75...2.5 mm²
Flexible with Insulated Ferrule 2x 0.75...1.5 mm²
Rigid 1/2x 1...2.5 mm²
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
5...300 Hz 3 g closed position / 3 g open position
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g