Description
Time-delay, low breaking capacity
• Optional axial leads available
• 5 x 20mm physical size
• Glass tube, nickel-plated brass endcap construction
• Designed to IEC 60127-2/3 (32mA-10A) &
extensions:12.5A-15A
Agency Information
UL Recognized Card: Guide JDYX2, File E19180
CSA Component Acceptance: File 1803366
cURus Recognition: Guide JDYX8, File E19180
SEMKO Approval: File 507078, 415434, 806492
VDE Approval: File 40011926
BSI Approval: File KM55676
IMQ Approval: File E1921, CA03.00530
PSE/JET: File JET1641-31003-1005,
JET1641-31003-1006
CCC Approval: File 2005010207155693,
2002010207011294
Ordering
Specify product code
Insert packaging code prefix before part number. E.g.
BK/S506-1-R
Specify option code if desired
For axial leads, insert “V” between catalog series and
amp rating. E.g. BK/S506-V-2-R
Dimensions - mm
Drawing Not to Scale
S506 Electrical Characteristics
2.1 In2.75 In4 In10 In
Inmax min max min max min max
32mA-100mA 2 min 200 ms 10 sec 40 ms 3 sec 10 ms 300 ms
125mA-6.3A 2 min 600 ms 10 sec 150 ms 3 sec 20 ms 300 ms
8A-15A 2 min 600 ms 10 sec 150 ms 3 sec 20 ms 300 ms
5 x 20mm Fuses
S506 Series, Time-Delay, Glass Tube
0709 BU-SB08673 Page 1 of 2 Data Sheet 4332
Specifications
Voltage
Interrupting Rating
Typical DC Typical Typical Agency Approvals
Product Rating
(amps) at Rated
Cold Resistance Melting I2t Voltage IMQ VDE BSI SEMKO UR CCC PSE/ CSA cURus
Code Vac
Voltage (50Hz) Vac
(Ω)* (amps) Drop (mV)‡ JET
S506-32-R 250 35 21.0 0.0051 1050 X X X X X X
S506-40-R 250 35 13.90 0.0072 920 X X X X X X
S506-50-R 250 35 9.24 0.0095 800 X X X X X X X
S506-63-R 250 35 6.96 0.021 760 X X X X X X X
S506-80-R 250 35 4.42 0.038 580 X X X X X X X
S506-100-R 250 35 2.80 0.045 490 X X X X X X X
S506-125-R 250 35 1.97 0.063 390 X X X X X X X
S506-160-R 250 35 1.27 0.093 320 X X X X X X X
S506-200-R 250 35 1.00 0.114 340 X X X X X X X
S506-250-R 250 35 0.640 0.265 270 X X X X X X X
S506-315-R 250 35 0.450 0.621 250 X X X X X X X
S506-400-R 250 35 0.31 0.872 210 X X X X X X X
S506-500-R 250 35 0.183 0.827 140 X X X X X X X X
S506-630-R 250 35 0.186 1.33 150 X X X X X X X X
S506-800-R 250 35 0.129 2.78 75 X X X X X X X X
S506-1-R 250 35 0.0757 6.45 87.5 X X X X X X X X X
S506-1.25-R 250 35 0.060 10.05 86 X X X X X X X X X
S506-1.6-R 250 35 0.0425 21.7 82 X X X X X X X X X
S506-2-R 250 35 0.03325 31.6 77 X X X X X X X X X
S506-2.5-R 250 35 0.0255 59.4 72.5 X X X X X X X X X
S506-3.15-R 250 35 0.0185 96.4 68.5 X X X X X X X X X
S506-4-R 250 40 0.0139 71.8 67 X X X X X X X X X
S506-5-R 250 50 0.00985 142.5 60.5 X X X X X X X X X
S506-6.3-R 250 63 0.0071 237.6 54 X X X X X X X X X
S506-8-R 250 80 0.007 255.8 55 X X X X X X X X
S506-10-R 250 100 0.005 450 54 X X X X X X X X
S506-12.5-R 250 125 0.004 1019.5 45 X X X
S506-15-R 250 125 0.004 1091.7 65.5 X X X
* DC Cold Resistance (measured at <10% of rated current)
Typical Voltage Drop (voltage drop was measured at 20°C ambient temperature at rated current)
Ratings above 4A have a 0.81mm diameter lead
Nominal Time-Current Characterisitics of S506-R
Packaging Code
Packaging Code Suffix Description
BK 100 fuses packed into a cardboard carton
BK1 1,000 fuses packed into a poly bag
TR2 1,500 fuses packed into tape on a reel (19.05mm lead wire length)
Option Code
Option Code Description
VAxial leads - copper tinned wire with nickel plated brass endcaps
© 2009 Cooper Bussmann
St. Louis, MO 63178
www.cooperbussmann.com
0709 BU-SB08673 Page 2 of 2 Data Sheet 4332
The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is
intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change
design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained
in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
Life Support Policy: Cooper Bussmann does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support
systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in
significant injury to the user.