OMRON (R) OMRON NETWORK PRODUCTS 1.0 Description The P1RX4C-SX4x-01MM (SX4 ROSA Module) is an optical to electrical (O-E) module that receives four video- or data-channels from one singlemode or multimode fiber. With the TIA and Limiting Amp embedded in the OSA and enclosed in an EMI shielded metal housing, the SX4 ROSA module is a fully integrated receiver versatile enough to be designed in to a variety of systems. 2.0 Features * * * * Multiple signals from one Multimode fiber Integrated TIA and Limiting Amp Metal enclosure with SC optical interface CML outputs This device is EXTREMELY SENSITIVE to Electrostatic Discharge (ESD). At a minimum, all handling must be performed in accordance with an ANSI-compliant ESD Control Program (ANSI/ESD S20.20-2007) to mitigate possible ESD-induced damage. Reliability and life of the device will be adversely affected if these precautions are not met. This device is a Class 3R Laser device (per IEC 60825-1:2007) and can cause damage to eye sight if used improperly. Refer to ANSI Z136 for proper handling and usage of Class 3R devices. ORIGINATOR: OMRON C. ENG Date: P1RX4C-SX4x-01MM Product Specification 7/8/2011 DOCUMENT NO. REV DOC002107 A SHEET 1 OF 6 OMRON (R) OMRON NETWORK PRODUCTS 3.0 Absolute Maximum Ratings Parameter Symbol Min Tst VCC1 Ta RH -40 -0.3 0 1, 3 Storage Temperature 3.3V Supply Voltage 2 Operating Surface Temperature 3 Operating Humidity Durability - SC Connector Durability - Plug-down Connector 4.0 Typ Max Units 85 3.6 65 80 C V C 200 50 % cycles cycles Optical Characteristics Parameter (per channel) Symbol Min Typ Max Units Wavelength - Lane 0 778 nm Wavelength - Lane 1 800 nm Wavelength - Lane 2 825 nm Wavelength - Lane 3 4 Data Rate per Channel P1RX4C-SX4V-01 P1RX4C-SX4D-01 850 nm DR 1.65 3.50 Gb/s Peak Optical Input Power Pin 4.0 dBm 5 OMA Sensitivity -14.25 -16.00 dBm 1 Stresses listed may be applied without causing damage. Functionality at or above the values listed is not implied. Exposure to these values for extended periods may affect reliability. See outline drawing for measurement point. 3 Non condensing, 80% RH. 4 Requires DC-balanced data pattern and max run rate of 80 bits. Measured with input signals conforming to HDMI rev 1.3a, section 4.2.5, figure 4-20. 5 Optical Modulation Amplitude. Based on an unstressed input signal. 2 ORIGINATOR: OMRON C. ENG DATE: P1RX4C-SX4x-01MM Product Specification 7/8/2011 DOCUMENT NO. REV DOC002107 A SHEET 2 OF 6 OMRON (R) OMRON NETWORK PRODUCTS 5.0 Electrical Specifications Parameter Symbol Low Frequency Cutoff Min Typ FCUTOFF 6 Total Jitter (RMS), per lane Max 175 Units kHz TJ1 10 ps VOD 500 mVp-p LOSSEN-ON -14.50 dBm Loss of Signal De-Assert Sensitivity LOSSEN-OFF -13.00 dBm 7 Differential Output Voltage Loss of Signal Assert Sensitivity 8 VLOS Loss of Signal Output High VLOS 2 Operating Supply Voltage VCC 3.15 Operating Supply Current ICC Loss of Signal Output Low 0.7 V V 3.30 127 3.54 V mA 6 Based on a jitter-free source CML interface through a 100-ohm differential load. 8 This output is asserted low when a loss of signal is detected on all Lanes 7 ORIGINATOR: OMRON C. ENG DATE: P1RX4C-SX4x-01MM Product Specification 7/8/2011 DOCUMENT NO. REV DOC002107 A SHEET 3 OF 6 OMRON (R) OMRON NETWORK PRODUCTS 6.0 Pin Numbers and Descriptions The RX-SX4 plugs into a 30 pin connector. For information on the specifications of the connector, contact Hirose (DF12(4.0)-30DP-0.5V(86)). 7.0 Pin # Signal Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 GND LOS +TD0 NC -TD0 NC +TD1 NC -TD1 NC +TD2 NC -TD2 NC +TD3 NC -TD3 NC GND NC NC NC NC NC NC NC NC VCC GND VCC Ground Global Loss of Signal Indicator Positive Data Output (778nm) No Connect9 Negative Data Output (778nm) No Connect9 Positive Data Output (800nm) No Connect9 Negative Data Output (800nm) No Connect9 Positive Data Output (825nm) No Connect9 Negative Data Output (825nm) No Connect9 Positive Data Output (850nm) No Connect9 Negative Data Output (850nm) No Connect9 Ground No Connect9 No Connect9 No Connect9 No Connect9 No Connect9 No Connect9 No Connect9 No Connect9 3.3 volt input. Ground 3.3 volt input. Laser Safety The P1RX4-SX4x-01 meets Class-3 requirements. 9 NC = No Connect. Do not connect anything to this pin. ORIGINATOR: OMRON C. ENG DATE: P1RX4C-SX4x-01MM Product Specification 7/8/2011 DOCUMENT NO. REV DOC002107 A SHEET 4 OF 6 OMRON (R) OMRON NETWORK PRODUCTS 8.0 Environmental Standards Omron Network Products designs and manufactures its products to minimize the negative impact on our environment. As such, the P1RX4C-SX4-01MM conforms to a variety of environmental and safety standards Standard RoHS ORIGINATOR: OMRON C. ENG Compliant Yes DATE: P1RX4C-SX4x-01MM Product Specification Certificate Available Yes 7/8/2011 DOCUMENT NO. REV DOC002107 A SHEET 5 OF 6 OMRON (R) OMRON NETWORK PRODUCTS Dimensions The SX4 ROSA is designed to work with a standard SC ferrule only. Insertion of any other type may result in damage. Dimensions (mm) and orientation are for reference only. Temperature measurement point ORIGINATOR: OMRON C. ENG DATE: P1RX4C-SX4x-01MM Product Specification 7/8/2011 DOCUMENT NO. REV DOC002107 A SHEET 6 OF 6