MPL115A1 Miniature SPI digital barometer, 50 to 115 kPa Rev. 8 -- 10 October 2017 1 Data sheet: technical data General description The MPL115A1 is an absolute pressure sensor with a digital SPI output targeting low cost applications. A miniature 5 x 3 x 1.2 mm LGA package is ideally suited for the space constrained requirements of portable electronic devices. Low current consumptions of 5 A during Active mode and 1 A during Shutdown (Sleep) mode are essential when focusing on low-power applications. The wide operating temperature range spans from - 40 C to +105 C to fit demanding environment conditions. The MPL115A1 employs a MEMS pressure sensor with a conditioning IC to provide accurate pressure measurements from 50 to 115 kPa. An integrated ADC converts pressure and temperature sensor readings to digitized outputs via a SPI port. Factory calibration data is stored internally in an on-board ROM. Utilizing the raw sensor output and calibration data, the host microcontroller executes a compensation algorithm to render Compensated Absolute Pressure with 1 kPa accuracy. The MPL115A1 pressure sensor's small form factor, low power capability, precision, and digital output optimize it for barometric measurement applications. 2 Features * Digitized pressure and temperature information together with programmed calibration coefficients for host micro use. * Factory calibrated * 50 kPa to 115 kPa absolute pressure * 1 kPa accuracy * 2.375 V to 5.5 V supply * Integrated ADC * SPI Interface * Monotonic pressure and temperature data outputs * Surface mount RoHS compliant package 3 Applications * * * * * * * Barometry (portable and desktop) Altimeters Weather stations Hard-disk drives (HDD) Industrial equipment Health monitoring Air control systems MPL115A1 NXP Semiconductors Miniature SPI digital barometer, 50 to 115 kPa 4 Ordering information Table 1. Ordering information Type number MPL115A1 Package Name Description Version TSON8 LGA 8 I/O, 3 X 5 X 1.25 PITCH, SENSOR 1.2MAX MM PKG SOT1769-1 4.1 Ordering options Table 2. Ordering options Device Name Package Options # of Ports None Single Pressure Type Dual Gauge Differential Absolute Digital Interface MPL115A1 Tray * * SPI MPL115A1T1 Tape & Reel (1000) * * SPI 5 Block diagram Figure 1. Block diagram of MPL115A1 MPL115A1 Data sheet: technical data All information provided in this document is subject to legal disclaimers. Rev. 8 -- 10 October 2017 (c) NXP B.V. 2017. All rights reserved. 2 / 23 MPL115A1 NXP Semiconductors Miniature SPI digital barometer, 50 to 115 kPa 6 Pinning information 6.1 Pinning MPL115A1 VDD 1 8 SCLK CAP 2 7 DIN GND 3 6 DOUT SHDN 4 5 CS transparent top view Figure 2. Pin configuration 6.2 Pin description Table 3. Pin description 7 Pin Name 1 VDD Power Supply Connection. VDD range is 2.375 V to 5.5 V. 2 CAP External Capacitor: Output decoupling capacitor for main internal regulator. Connect a 1 F ceramic capacitor to ground. 3 GND Ground 4 SHDN 5 CS 6 DOUT 7 DIN 8 SCLK Function Shutdown: Connect to GND to disable the device. When in shut down the part draws no more than 1 A supply current and all communications pins (CS, SCLK, DOUT, DIN) are high impedance. Connect to VDD for normal operation. Chip Select line. Serial data output Serial data input Serial clock input. Handling and Board Mount Recommendations The sensor die is sensitive to light exposure. Direct light exposure through the port hole can lead to varied accuracy of pressure measurement. Avoid such exposure to the port during normal operation. 7.1 Methods of Handling Components can be picked from the carrier tape using either the vacuum assist or the mechanical type pickup heads. A vacuum assist nozzle type is most common due to its lower cost of maintenance and ease of operation. The recommended vacuum nozzle configuration should be designed to make contact with the device directly on the metal cover and avoid vacuum port location directly over the vent hole in the metal cover of the MPL115A1 Data sheet: technical data All information provided in this document is subject to legal disclaimers. Rev. 8 -- 10 October 2017 (c) NXP B.V. 2017. All rights reserved. 3 / 23 MPL115A1 NXP Semiconductors Miniature SPI digital barometer, 50 to 115 kPa device. Multiple vacuum ports within the nozzle may be required to effectively handle the device and prevent shifting during movement to placement position. Vacuum pressure required to adequately support the component should be approximately 25 inches Hg (85 kPa). This level is typical of in-house vacuum supply. Pickup nozzles are available in various sizes and configurations to suit a variety of component geometries. To select the nozzle best suited for the specific application, it is recommended that the customer consult their pick and place equipment supplier to determine the correct nozzle. In some cases it may be necessary to fabricate a special nozzle depending on the equipment and speed of operation. Tweezers or other mechanical forms of handling that have a sharp point are not recommended since they can inadvertently be inserted into the vent hole of the device. This can lead to a puncture of the MEMS element that will render the device inoperable. 7.2 Board Mount Recommendations Components can be mounted using solder paste stencil, screen printed or dispensed onto the PCB pads prior to placement of the component. The volume of solder paste applied to the PCB is normally sufficient to secure the component during transport to the subsequent reflow soldering process. Use of adhesives to secure the component is not recommended, but where necessary can be applied to the underside of the device. Solder pastes are available in variety of metal compositions, particle size and flux types. The solder paste consists of metals and flux required for a reliable connection between the component lead and the PCB pad. Flux aids the removal of oxides that may be present on PCB pads and prevents further oxidation from occurring during the solder process. The use of a No-Clean (NC) flux is recommended for exposed cavity components. Using pressure spray, wire brush, or other methods of cleaning is not recommended since it can puncture the MEMS device and render it unusable. If cleaning of the pcb is performed, Water Soluble (WS) flux can be used. However, it is recommended the component cavity is protected by adhesive Kapton tape, vinyl cap or other means prior to the cleaning process. This covering will prevent damage to the MEMS device, contamination, and foreign materials from being introduced into device cavity as result of cleaning processes. Ultrasonic cleaning is not recommended as the frequencies can damage wire bond interconnections and the MEMS device. MPL115A1 Data sheet: technical data All information provided in this document is subject to legal disclaimers. Rev. 8 -- 10 October 2017 (c) NXP B.V. 2017. All rights reserved. 4 / 23 MPL115A1 NXP Semiconductors Miniature SPI digital barometer, 50 to 115 kPa 8 Functional description Initial powe rup Readin g coefficient data Data conversion Compensated pressure readin g Shutdown Figure 3. Sequence flow chart The MPL115A interfaces to a host (or system) microcontroller in the user's application. All communications are via SPI. A typical usage sequence is as follows: Initial power-up All circuit elements are active. SPI port pins are high impedance and associated registers are cleared. The device then enters standby mode. Reading coefficient data The user then typically accesses the part and reads the coefficient data. The main circuits within the slave device are disabled during read activity. The coefficients are usually stored in the host microcontoller local memory but can be re-read at any time. Reading of the coefficients may be executed only once and the values stored in the host microcontroller. It is not necessary to read this multiple times because the coefficients within a device are constant and do not change. However, note that the coefficients will be different from device to device, and cannot be used for another part. Data conversion This is the first step that is performed each time a new pressure reading is required which is initiated by the host sending the CONVERT command. The main system circuits are activated (wake) in response to the command and after the conversion completes, the result is placed into the Pressure and Temperature ADC output registers. The conversion completes within the maximum conversion time, tc (see row 6, in Table 11). The device then enters standby mode. MPL115A1 Data sheet: technical data All information provided in this document is subject to legal disclaimers. Rev. 8 -- 10 October 2017 (c) NXP B.V. 2017. All rights reserved. 5 / 23 MPL115A1 NXP Semiconductors Miniature SPI digital barometer, 50 to 115 kPa Compensated pressure reading After the conversion has been given sufficient time to complete, the host microcontroller reads the result from the ADC output registers and calculates the Compensated Pressure, a barometric/atmospheric pressure value which is compensated for changes in temperature and pressure sensor linearity. This is done using the coefficient data from the MPL115A and the raw sampled pressure and temperature ADC output values, in a compensation equation (detailed later). Note that this is an absolute pressure measurement with a vacuum as a reference. From this step the host controller may either wait and then return to the Data Conversion step to obtain the next pressure reading or it may go to the Shutdown step. Shutdown For longer periods of inactivity the user may assert the SHDN input by driving this pin low to reduce system power consumption. This removes power from all internal circuits, including any registers. In the shutdown state, the Pressure and Temperature registers will be reset, losing any previous ADC output values. This step is exited by taking the SHDN pin high. Wait for the maximum wakeup time, tw (see row 7, in Table 11), after which another pressure reading can be taken by transitioning to the data Conversion step. Table 4. Device memory map Address Name Description 00h Padc_MSB 10-bit Pressure ADC output value MSB 01h Padc_LSB 10-bit Pressure ADC output value LSB 02h Tadc_MSB 10-bit Temperature ADC output value MSB 03h Tacd_LSB 10-bit Temperature ADC output value LSB 04h a0_MSB a0 coefficient MSB 05h a0_LSB a0 coefficient LSB 06h b1_MSB b1 coefficient MSB 07h b1_LSB b1 coefficient LSB 08h b2_MSB b2 coefficient MSB 09h b2_LSB b2 coefficient LSB 0Ah c12_MSB c12 coefficient MSB 0Bh c12_LSB c12 coefficient LSB 0Ch reserved Data sheet: technical data -- [1] -- [1] -- [1] -- 0Dh reserved 0Eh reserved 0Fh MPL115A1 [1] reserved All information provided in this document is subject to legal disclaimers. Rev. 8 -- 10 October 2017 (c) NXP B.V. 2017. All rights reserved. 6 / 23 MPL115A1 NXP Semiconductors Miniature SPI digital barometer, 50 to 115 kPa Address Name Description 10h reserved -- 11h reserved -- 12h CONVERT Start Pressure and Temperature Conversion [1] This register is set to 00h. It is reserved, and was previously utilized as Coefficient values, c11 and c22, which were always 00h. For values with less than 16 bits, the lower LSBs are zero. For example, c12 is 14 bits and is stored into 2 bytes as follows: c12 MS byte = c12[13:6] = [c12b13 , c12b12 , c12b11 , c12b10 , c12b9 , c12b8 , c12b7 , c12b6] c12 LS byte = c12[5:0] & "00" = [c12b5 , c12b4 , c12b3 , c12b2 , c12b1 , c12b0 , 0 , 0] 8.1 Pressure, temperature and coefficient bit-width specifications The table below specifies the initial coefficient bit-width specifications for the compensation algorithm and the specifications for Pressure and Temperature ADC values. Table 5. Pressure, temperature and compensation coefficient specifications a0 b1 b2 c12 Padc Tadc Total Bits 16 16 16 14 10 10 Sign Bits 1 1 1 1 0 0 Integer Bits 12 2 1 0 10 10 Fractional Bits 3 13 14 13 0 0 dec pt zero pad 0 0 0 9 0 0 Example Binary Format Definitions: a0 Signed, Integer Bits = 12, Fractional Bits = 3 : Coeff a0 = S I11 I10 I9 I8 I7 I6 I5 I4 I3 I2 I1 I0 . F2 F1 F0 b1 Signed, Integer Bits = 2, Fractional Bits = 13 : Coeff b1 = S I1 I0 . F12 F11 F10 F9 F8 F7 F6 F5 F4 F3 F2 F1 F0 b2 Signed, Integer Bits = 1, Fractional Bits = 14 : Coeff b2 = S I0 . F13 F12 F11 F10 F9 F8 F7 F6 F5 F4 F3 F2 F1 F0 c12 Signed, Integer Bits = 0, Fractional Bits = 13, dec pt zero pad = 9 : Coeff c12 = S 0 . 000 000 000 F12 F11 F10 F9 F8 F7 F6 F5 F4 F3 F2 F1 F0 Padc Unsigned, Integer Bits = 10 : Padc U = I9 I8 I7 I6 I5 I4 I3 I2 I1 I0 Tadc Unsigned, Integer Bits =10 : Tadc U = I9 I8 I7 I6 I5 I4 I3 I2 I1 I0 Note: Negative coefficients are coded in 2's complement notation. 8.2 Compensation The 10-bit compensated pressure output, Pcomp, is calculated as follows: MPL115A1 Data sheet: technical data All information provided in this document is subject to legal disclaimers. Rev. 8 -- 10 October 2017 (c) NXP B.V. 2017. All rights reserved. 7 / 23 MPL115A1 NXP Semiconductors Miniature SPI digital barometer, 50 to 115 kPa (1) Where: Padc is the 10-bit pressure ADC output of the MPL115A Tadc is the 10-bit temperature ADC output of the MPL115A a0 is the pressure offset coefficient b1 is the pressure sensitivity coefficient b2 is the temperature coefficient of offset (TCO) c12 is the temperature coefficient of sensitivity (TCS) Pcomp will produce a value of 0 with an input pressure of 50 kPa and will produce a fullscale value of 1023 with an input pressure of 115 kPa. (2) 8.3 Evaluation sequence, arithmetic circuits The following is an example of the calculation for Pcomp, the compensated pressure output. Input values are in bold. c12x2 = c12 * Tadc a1 = b1 + c12x2 a1x1 = a1 * Padc y1 = a0 + a1x1 a2x2 = b2 * Tadc Pcomp = y1 + a2x2 This can be calculated as a succession of Multiply Accumulates (MACs) operations of the form y = a + b * x: a b + y X x The polynomial can be evaluated (Equation 1) as a sequence of 3 MACs: MPL115A1 Data sheet: technical data All information provided in this document is subject to legal disclaimers. Rev. 8 -- 10 October 2017 (c) NXP B.V. 2017. All rights reserved. 8 / 23 MPL115A1 NXP Semiconductors Miniature SPI digital barometer, 50 to 115 kPa b1 a1 c12 Tadc y1 a0 Padc y b2 PComp Tadc Please refer to NXP application note AN3785 for more detailed notes on implementation. 8.4 SPI device read/write operations All device read/write operations are memory mapped. Device actions e.g. "Start Conversions" are controlled by writing to the appropriate memory address location. All memory address locations are 6-bit (see Table 2). The 8-bit command word comprises: * the most significant bit which is the Read/Write identifier which is '1' for read operations and '0' for write operations. * the 6-bit address (from Table 4); * the least significant bit which is not used and is don't care (X). The device write commands are shown in Table 6. Table 6. SPI write command Legend: X = don't care Command Binary Start Conversions [1] HEX 0010010X [1] 24h The command byte needs to be paired with a 00h as part of the SPI exchange to complete the passing of Start Conversions. The actions taken by the part in response to each command are as follows: Table 7. SPI Write command description Command Start Conversions MPL115A1 Data sheet: technical data Action taken Wake main circuits. Start clock. Allow supply stabilization time. Select pressure sensor input. Apply positive sensor excitation and perform A to D conversion. Select temperature input. Perform A to D conversion. Load the Pressure and Temperature registers with the result. Shut down main circuits and clock. All information provided in this document is subject to legal disclaimers. Rev. 8 -- 10 October 2017 (c) NXP B.V. 2017. All rights reserved. 9 / 23 MPL115A1 NXP Semiconductors Miniature SPI digital barometer, 50 to 115 kPa SPI Read operations are performed by sending the required address with a leading Read bit set to `1'. SPI operations require that each byte be addressed individually. All data is transmitted most significant bit first. Table 8. Example SPI Read Commands Legend: X = don't care Command Binary HEX [1] Read Pressure MSB 1000000X 80h Read Pressure LSB 1000001X 82h Read Temperature MSB 1000010X 84h Read Temperature LSB 1000011X 86h Read Coefficient data byte 1 1000100X 88h [1] The command byte needs to be paired with a 00h as part of the SPI exchange to complete the passing of stated command. 8.5 SPI timing Table 9 and Figure 4 describe the timing requirements for the SPI system. Table 9. SPI timing Ref Symbol Function Min Max Unit -- 8 MHz 1 Of Operating Frequency 2 tSCLK SCLK Period 125 -- ns 3 tCLKH SCLK High time 62.5 -- ns 4 tCLKL SCLK Low time 62.5 -- ns 5 tSCS Enable lead time 125 -- ns 6 tHCS Enable lag time 125 -- ns 7 tSET Data setup time 30 -- ns 8 tHOLD Data hold time 30 -- ns 9 tDDLY Data valid (after SCLK low edge) -- 32 ns 10 tWCS Width CS High 30 -- ns Figure 4. SPI timing diagram MPL115A1 Data sheet: technical data All information provided in this document is subject to legal disclaimers. Rev. 8 -- 10 October 2017 (c) NXP B.V. 2017. All rights reserved. 10 / 23 MPL115A1 NXP Semiconductors Miniature SPI digital barometer, 50 to 115 kPa 8.6 Example of SPI reading of coefficients These are MPL115A1 SPI commands to read coefficients, execute Pressure and Temperature conversions, and to read Pressure and Temperature data. The sequence of the commands for the interaction is given as an example to operate the MPL115A1. Utilizing this gathered data, an example of the calculating the Compensated Pressure reading is given in floating point notation. SPI Commands (simplified for communication) Command to Write "Convert Pressure and Temperature" = 24h Command to Read "Pressure ADC High byte" = 80h Command to Read "Pressure ADC Low byte" = 82h Command to Read "Temperature ADC High byte" = 84h Command to Read "Temperature ADC Low byte" = 86h Command to Read "Coefficient data byte 1 High byte" = 88h Read coefficients: [CS=0], [88h], [00h], [8Ah], [00h], [8Ch], [00h], [8Eh], [00h], [90h], [00h], [92h], [00h], [94h], [00h], [96h], [00h], [00h], [CS=1] Start pressure and temperature conversion, read raw pressure: [CS=0], [24h], [00h], [CS=1], [3 ms Delay] [CS=0], [80h], [00h], [82h], [00h], [84h], [00h], [86h], [00h], [00h], [CS=1] Note: Extra [00h] at the end of each sequence to output the last data byte on the slave side of the SPI. Figure 5. SPI read coefficient datagram MPL115A1 Data sheet: technical data All information provided in this document is subject to legal disclaimers. Rev. 8 -- 10 October 2017 (c) NXP B.V. 2017. All rights reserved. 11 / 23 MPL115A1 NXP Semiconductors Miniature SPI digital barometer, 50 to 115 kPa a0 coefficient MSB = 41h a0 coefficient LSB = DFh b1 coefficient MSB = B0h b1 coefficient LSB = 28h b2 coefficient MSB = BEh b2 coefficient LSB = ADh c12 coefficient MSB = 38h c12 coefficient LSB = CCh a0 coefficient = 41DFh = 2107.875 b1 coefficient = B028h = -2.49512 b2 coefficient = BEADh = -1.02069 c12 coefficient = 38CCh = 0.00086665 Figure 6. SPI start conversion datagram Command to start pressure and temperature conversion, 24h Figure 7. SPI read results datagram Pressure MSB = 67h Pressure LSB = C0h Pressure = 67C0h = 0110 0111 11 00 0000 = 415 ADC counts Temperature MSB = 80h Temperature LSB = 40h Temperature = 8040h = 1000 0000 01 00 0000 = 513 ADC counts MPL115A1 Data sheet: technical data All information provided in this document is subject to legal disclaimers. Rev. 8 -- 10 October 2017 (c) NXP B.V. 2017. All rights reserved. 12 / 23 MPL115A1 NXP Semiconductors Miniature SPI digital barometer, 50 to 115 kPa 8.7 Example of pressure compensated calculation in floating-point notation a0 coefficient = 2107.875 b1 coefficient = -2.49512 b2 coefficient = -1.02069 c12 coefficient = 0.00086665 Pressure = 415 ADC counts Temperature = 513 ADC counts Pressure compensation Using the evaluation sequence The evaluation sequence is located in Section 8.3. MPL115A1 Data sheet: technical data c12x2 = c12 * Tadc = 0.00086665 * 513 a1 = b1 + c12x2 = -2.49512 + 0.44459 = -2.05052 a1x1 = a1 * Padc = -2.05052 * 415 = -850.96785 y1 = a0 + a1x1 = 2107.875 + (-850.96785) = 1256.90715 a2x2 = b2 * Tadc = -1.02069 * 513 = -523.61444 PComp = y1 + a2x2 = 1256.90715 + (- 523.61444) = 733.29270 All information provided in this document is subject to legal disclaimers. Rev. 8 -- 10 October 2017 = 0.44459 (c) NXP B.V. 2017. All rights reserved. 13 / 23 MPL115A1 NXP Semiconductors Miniature SPI digital barometer, 50 to 115 kPa 9 Maximum ratings Table 10. Maximum ratings Voltage (with respect to GND unless otherwise noted) Symbol Value Units -0.3 to +5.5 V -0.3 to VDD + 0.3 V Operating Temperature Range -40 to +105 C Storage Temperature Range -40 to +125 C 1000 kPa VDD SHDN, SCLK, CS, DIN, DOUT Overpressure 10 Mechanical and electrical characteristics Table 11. Mechanical and electrical characteristics VDD = 2.375 V to 5.5 V, TA = -40 C to +105 C, unless otherwise noted. Typical values are at VDD = 3.3 V, TA = +25 C. Ref Parameters Symbol 1 Operating Supply Voltage VDD 2 Supply Current IDD Conditions Min Typ Max Units 2.375 3.3 5.5 V Shutdown (SHDN = GND) -- -- 1 A Standby -- 3.5 10 A Average - at one measurement per second -- 5 -- A Pressure Sensor 3 Range 50 -- 115 kPa 4 Resolution -- 0.15 -- kPa 5 Accuracy -20 C to 85 C -- -- 1 kPa 6 Conversion Time (Start Pressure and Temperature Conversion) tc Time between start convert command and data available in the Pressure and Temperature registers -- 1.6 3 ms 7 Wakeup Time tw Time between leaving Shutdown mode (SHDN goes high) and communicating with the device to issue a command or read data. -- 3 5 ms [1] -- -- 8 MHz SPI Inputs: SCLK, CS, DIN 8 SCLK Clock Frequency fSCLK 9 Low Level Input Voltage VIL -- -- 0.3VDD V 10 High Level Input Voltage VIH 0.7VDD -- -- V V SPI Outputs: DOUT 11 12 Low Level Output Voltage High Level Output Voltage MPL115A1 Data sheet: technical data VOL1 At 3 mA sink current 0 -- 0.4 VOL2 At 6 mA sink current 0 -- 0.6 VOH1 At 3 mA source current VDD - 0.4 -- -- All information provided in this document is subject to legal disclaimers. Rev. 8 -- 10 October 2017 (c) NXP B.V. 2017. All rights reserved. 14 / 23 MPL115A1 NXP Semiconductors Miniature SPI digital barometer, 50 to 115 kPa [1] Nominal maximum SPI clock frequency. 11 Package outline MPL115A1 Data sheet: technical data All information provided in this document is subject to legal disclaimers. Rev. 8 -- 10 October 2017 (c) NXP B.V. 2017. All rights reserved. 15 / 23 MPL115A1 NXP Semiconductors Miniature SPI digital barometer, 50 to 115 kPa Figure 8. Package outline SOT1769-1 (TSON8) MPL115A1 Data sheet: technical data All information provided in this document is subject to legal disclaimers. Rev. 8 -- 10 October 2017 (c) NXP B.V. 2017. All rights reserved. 16 / 23 MPL115A1 NXP Semiconductors Miniature SPI digital barometer, 50 to 115 kPa 12 Packing information Figure 9. LGA (3 x 5) embossed carrier tape dimensions Figure 10. Device orientation in chip carrier MPL115A1 Data sheet: technical data All information provided in this document is subject to legal disclaimers. Rev. 8 -- 10 October 2017 (c) NXP B.V. 2017. All rights reserved. 17 / 23 MPL115A1 NXP Semiconductors Miniature SPI digital barometer, 50 to 115 kPa 13 Soldering 1. Use SAC solder alloy, i.e., Sn-Ag-Cu, with a melting point of about 217 C. It is recommended to use SAC305, i.e., Sn-3.0 wt.% Ag-0.5 wt.% Cu. 2. Reflow * Ramp up rate: 2 to 3 C/s. * Preheat flat (soak): 110 to 130 s. * Reflow peak temperature: 250 C to 260 C (depends on exact SAC alloy composition). * Time above 217C: 40 to 90s (depends on board type, thermal mass of the board/ quantities in the reflow). * Ramp down: 5 to 6 C/s. * Using an inert reflow environment (with O2 level about 5 to 15 ppm). Note: The stress level and signal offset of the device also depends on the board type, board core material, board thickness and metal finishing of the board. 14 Soldering/landing pad information The LGA package is compliant with the RoHS standard. It is recommended to use a noclean solder paste to reduce cleaning exposure to high pressure and chemical agents that can damage or reduce life span of the Pressure sensing element. Figure 11. Recommended PCB landing pattern MPL115A1 Data sheet: technical data All information provided in this document is subject to legal disclaimers. Rev. 8 -- 10 October 2017 (c) NXP B.V. 2017. All rights reserved. 18 / 23 MPL115A1 NXP Semiconductors Miniature SPI digital barometer, 50 to 115 kPa 15 Revision history Table 12. Revision history Document ID Release date Data sheet status Change notice Supersedes MPL115A1 v.8 20171010 Technical data -- MPL115A1 v.7 Modifications: * The format of this data sheet has been redesigned to comply with the new identity guidelines of NXP Semiconductors. * Legal texts have been adapted to the new company name where appropriate. * Removed the first paragraph of Section 7. * Added Section 7.1 and Section 7.2 in Section 7 "Handling and Board Mount Recommendations" * Updated Figure 8. No technical changes. MPL115A1 v.7 02/2013 MPL115A1 Data sheet: technical data Technical data -- All information provided in this document is subject to legal disclaimers. Rev. 8 -- 10 October 2017 -- (c) NXP B.V. 2017. All rights reserved. 19 / 23 MPL115A1 NXP Semiconductors Miniature SPI digital barometer, 50 to 115 kPa 16 Legal information 16.1 Data sheet status Document status [1][2] Product status [3] Definition [short] Data sheet: product preview Development This document contains certain information on a product under development. NXP reserves the right to change or discontinue this product without notice. [short] Data sheet: advance information Qualification This document contains information on a new product. Specifications and information herein are subject to change without notice. [short] Data sheet: technical data Production This document contains the product specification. NXP Semiconductors reserves the right to change the detail specifications as may be required to permit improvements in the design of its products. [1] [2] [3] Please consult the most recently issued document before initiating or completing a design. The term 'short data sheet' is explained in section "Definitions". The product status of device(s) described in this document may have changed since this document was published and may differ in case of multiple devices. The latest product status information is available on the Internet at URL http://www.nxp.com. limitation specifications and product descriptions, at any time and without notice. This document supersedes and replaces all information supplied prior to the publication hereof. 16.2 Definitions Draft -- The document is a draft version only. The content is still under internal review and subject to formal approval, which may result in modifications or additions. NXP Semiconductors does not give any representations or warranties as to the accuracy or completeness of information included herein and shall have no liability for the consequences of use of such information. Short data sheet -- A short data sheet is an extract from a full data sheet with the same product type number(s) and title. A short data sheet is intended for quick reference only and should not be relied upon to contain detailed and full information. For detailed and full information see the relevant full data sheet, which is available on request via the local NXP Semiconductors sales office. In case of any inconsistency or conflict with the short data sheet, the full data sheet shall prevail. Product specification -- The information and data provided in a technical data data sheet shall define the specification of the product as agreed between NXP Semiconductors and its customer, unless NXP Semiconductors and customer have explicitly agreed otherwise in writing. In no event however, shall an agreement be valid in which the NXP Semiconductors product is deemed to offer functions and qualities beyond those described in the technical data data sheet. 16.3 Disclaimers Limited warranty and liability -- Information in this document is believed to be accurate and reliable. However, NXP Semiconductors does not give any representations or warranties, expressed or implied, as to the accuracy or completeness of such information and shall have no liability for the consequences of use of such information. NXP Semiconductors takes no responsibility for the content in this document if provided by an information source outside of NXP Semiconductors. In no event shall NXP Semiconductors be liable for any indirect, incidental, punitive, special or consequential damages (including - without limitation - lost profits, lost savings, business interruption, costs related to the removal or replacement of any products or rework charges) whether or not such damages are based on tort (including negligence), warranty, breach of contract or any other legal theory. Notwithstanding any damages that customer might incur for any reason whatsoever, NXP Semiconductors' aggregate and cumulative liability towards customer for the products described herein shall be limited in accordance with the Terms and conditions of commercial sale of NXP Semiconductors. Right to make changes -- NXP Semiconductors reserves the right to make changes to information published in this document, including without MPL115A1 Data sheet: technical data Suitability for use -- NXP Semiconductors products are not designed, authorized or warranted to be suitable for use in life support, life-critical or safety-critical systems or equipment, nor in applications where failure or malfunction of an NXP Semiconductors product can reasonably be expected to result in personal injury, death or severe property or environmental damage. NXP Semiconductors and its suppliers accept no liability for inclusion and/or use of NXP Semiconductors products in such equipment or applications and therefore such inclusion and/or use is at the customer's own risk. Applications -- Applications that are described herein for any of these products are for illustrative purposes only. NXP Semiconductors makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification. Customers are responsible for the design and operation of their applications and products using NXP Semiconductors products, and NXP Semiconductors accepts no liability for any assistance with applications or customer product design. It is customer's sole responsibility to determine whether the NXP Semiconductors product is suitable and fit for the customer's applications and products planned, as well as for the planned application and use of customer's third party customer(s). Customers should provide appropriate design and operating safeguards to minimize the risks associated with their applications and products. NXP Semiconductors does not accept any liability related to any default, damage, costs or problem which is based on any weakness or default in the customer's applications or products, or the application or use by customer's third party customer(s). Customer is responsible for doing all necessary testing for the customer's applications and products using NXP Semiconductors products in order to avoid a default of the applications and the products or of the application or use by customer's third party customer(s). NXP does not accept any liability in this respect. Limiting values -- Stress above one or more limiting values (as defined in the Absolute Maximum Ratings System of IEC 60134) will cause permanent damage to the device. Limiting values are stress ratings only and (proper) operation of the device at these or any other conditions above those given in the Recommended operating conditions section (if present) or the Characteristics sections of this document is not warranted. Constant or repeated exposure to limiting values will permanently and irreversibly affect the quality and reliability of the device. Terms and conditions of commercial sale -- NXP Semiconductors products are sold subject to the general terms and conditions of commercial sale, as published at http://www.nxp.com/profile/terms, unless otherwise agreed in a valid written individual agreement. In case an individual agreement is concluded only the terms and conditions of the respective agreement shall apply. NXP Semiconductors hereby expressly objects to All information provided in this document is subject to legal disclaimers. Rev. 8 -- 10 October 2017 (c) NXP B.V. 2017. All rights reserved. 20 / 23 MPL115A1 NXP Semiconductors Miniature SPI digital barometer, 50 to 115 kPa applying the customer's general terms and conditions with regard to the purchase of NXP Semiconductors products by customer. No offer to sell or license -- Nothing in this document may be interpreted or construed as an offer to sell products that is open for acceptance or the grant, conveyance or implication of any license under any copyrights, patents or other industrial or intellectual property rights. Export control -- This document as well as the item(s) described herein may be subject to export control regulations. Export might require a prior authorization from competent authorities. Non-automotive qualified products -- Unless this data sheet expressly states that this specific NXP Semiconductors product is automotive qualified, the product is not suitable for automotive use. It is neither qualified nor tested in accordance with automotive testing or application requirements. NXP Semiconductors accepts no liability for inclusion and/or use of nonautomotive qualified products in automotive equipment or applications. In the event that customer uses the product for design-in and use in automotive applications to automotive specifications and standards, customer (a) shall MPL115A1 Data sheet: technical data use the product without NXP Semiconductors' warranty of the product for such automotive applications, use and specifications, and (b) whenever customer uses the product for automotive applications beyond NXP Semiconductors' specifications such use shall be solely at customer's own risk, and (c) customer fully indemnifies NXP Semiconductors for any liability, damages or failed product claims resulting from customer design and use of the product for automotive applications beyond NXP Semiconductors' standard warranty and NXP Semiconductors' product specifications. Translations -- A non-English (translated) version of a document is for reference only. The English version shall prevail in case of any discrepancy between the translated and English versions. 16.4 Trademarks Notice: All referenced brands, product names, service names and trademarks are the property of their respective owners. NXP -- is a trademark of NXP B.V. All information provided in this document is subject to legal disclaimers. Rev. 8 -- 10 October 2017 (c) NXP B.V. 2017. All rights reserved. 21 / 23 MPL115A1 NXP Semiconductors Miniature SPI digital barometer, 50 to 115 kPa Tables Tab. 1. Tab. 2. Tab. 3. Tab. 4. Tab. 5. Tab. 6. Ordering information ..........................................2 Ordering options ................................................2 Pin description ...................................................3 Device memory map ......................................... 6 Pressure, temperature and compensation coefficient specifications ....................................7 SPI write command ...........................................9 Tab. 7. Tab. 8. Tab. 9. Tab. 10. Tab. 11. Tab. 12. SPI Write command description ........................9 Example SPI Read Commands ...................... 10 SPI timing ........................................................10 Maximum ratings ............................................. 14 Mechanical and electrical characteristics ........ 14 Revision history ...............................................19 Fig. 7. Fig. 8. Fig. 9. SPI read results datagram .............................. 12 Package outline SOT1769-1 (TSON8) ............ 15 LGA (3 x 5) embossed carrier tape dimensions ...................................................... 17 Device orientation in chip carrier .....................17 Recommended PCB landing pattern ............... 18 Figures Fig. 1. Fig. 2. Fig. 3. Fig. 4. Fig. 5. Fig. 6. Block diagram of MPL115A1 .............................2 Pin configuration ............................................... 3 Sequence flow chart ......................................... 5 SPI timing diagram ..........................................10 SPI read coefficient datagram .........................11 SPI start conversion datagram ........................12 MPL115A1 Data sheet: technical data Fig. 10. Fig. 11. All information provided in this document is subject to legal disclaimers. Rev. 8 -- 10 October 2017 (c) NXP B.V. 2017. All rights reserved. 22 / 23 MPL115A1 NXP Semiconductors Miniature SPI digital barometer, 50 to 115 kPa Contents 1 2 3 4 4.1 5 6 6.1 6.2 7 7.1 7.2 8 8.1 8.2 8.3 8.4 8.5 8.6 8.7 9 10 11 12 13 14 15 16 General description ............................................ 1 Features ............................................................... 1 Applications .........................................................1 Ordering information .......................................... 2 Ordering options ................................................ 2 Block diagram ..................................................... 2 Pinning information ............................................ 3 Pinning ............................................................... 3 Pin description ................................................... 3 Handling and Board Mount Recommendations .............................................. 3 Methods of Handling ......................................... 3 Board Mount Recommendations ....................... 4 Functional description ........................................5 Pressure, temperature and coefficient bitwidth specifications ............................................7 Compensation ....................................................7 Evaluation sequence, arithmetic circuits ............8 SPI device read/write operations ....................... 9 SPI timing ........................................................ 10 Example of SPI reading of coefficients ............ 11 Example of pressure compensated calculation in floating-point notation .................13 Maximum ratings ...............................................14 Mechanical and electrical characteristics .......14 Package outline .................................................15 Packing information ..........................................17 Soldering ............................................................18 Soldering/landing pad information ..................18 Revision history ................................................ 19 Legal information .............................................. 20 Please be aware that important notices concerning this document and the product(s) described herein, have been included in section 'Legal information'. (c) NXP B.V. 2017. All rights reserved. For more information, please visit: http://www.nxp.com For sales office addresses, please send an email to: salesaddresses@nxp.com Date of release: 10 October 2017 Document identifier: MPL115A1