Product Data Sheet 142X122 Replace "x" with 1, 2, or 3 for number of poles Power Terminal Block 200 Amps 600 Volts AC/DC Wire Range * * Line: (1) 1/4 - 20 X 5/8" stud Load: (1) 1/4 - 20 X 5/8" stud Electrical Ratings * * * * 200 Amps 600V per UL 1059 & CSA 22.2 No.158, class B & C requirements SCCR of 10,000 A (default for terminal blocks). Factory & Field Wiring Agency Compliance * * * UR - UL Recognized Terminal Block, Evaluated to UL 1059, File No.XCFR2.E62806 CSA - certifed to C22.2 No. 158, File No. LR19766 CE compliant to IEC 60947-7-1 Material Information * * * * * Insulator base: * Phenolic * Flammability rating of insulator base UL94V0 * Insulator base temperature rating: -40C to 150C (UL RTI) Connector: copper, tin plated Stud: brass, tin plated Connector mounting screws: steel, zinc plated RoHS compliant A Regal Brand www.marathonsp.com 1 Termination Specifications Load Side * * * * * Torque Stud Length Maximum Lug/Bar Width Listed lugs on 1/4 - 20 studs 6.9 N*m (61 lbf*in) 0.56" (14.mm) 0.63" (16mm) For use with conductors prepared with listed connectors such as single hole compression/crimp lugs or listed ring, fork or spade terminals. Conductor size, ampacity, temperature rating, and type are dictated by the ratings of the listed lugs utilized and applicable code requirements. Hex nut 7/16 across flats. Load Side * Termination Type Termination Type Torque Stud Length Maximum Lug/Bar Width Listed lugs on 1/4 - 20 studs 6.9 N*m (61 lbf*in) 0.56" (14.mm) 0.63" (16mm) For use with conductors prepared with listed connectors such as single hole compression/crimp lugs or listed ring, fork or spade terminals. Conductor size, ampacity, temperature rating, and type are dictated by the ratings of the listed lugs utilized and applicable code requirements. Hex nut 7/16 across flats. www.marathonsp.com 2 PDS 0236 REV-D 10/10/13 Installation & Accessories * Mounting (Panel): * For use with #10 fastener. * Torque mounting fastener to 25-30 lbf*in (2.8 - 3.4 N*m). * Covers: * Flat covers available upon request * Catalog Number: CC142x (replace "x" with number of poles) * Covers are clear polycarbonate * Accessory covers are not intended to provide insulation for electrical spacings. * Marker Strip: white vinyl strip with mounting screws available. * Printing options available, consult customer service for specifications. Drawing www.marathonsp.com 3 PDS 0236 REV-D 10/10/13