1
CSM_EE-SPW311_411_DS_E_3_1
Long-distance Through-beam Photomicrosensor
EE-SPW311/411
Through-beam Photomicrosensor
with a sensing distance as long as
1 m.
Easy operation monitoring with bright light indicator.
Wide operating voltage range: 5 to 24 VDC
Light modulation effectively reduces external light interference.
Easy-to-wire connector assures ease of maintenance.
Be sure to read Safety Precautions on
page 3.
Ordering Information
Sensors
* Both an EE-1006L Connector with Cable for the Emitter and an EE-1006D Connector with Cable for the Receiver are included with the Photomicrosensor.
Refer to Accessories when using non-standard connectors, including Robot Cables and PNP Adapters.
Appearance Sensing method Sensing distance Output type Output
configuration Model
Through-beam
type
NPN
output
Dark-ON EE-SPW311
Light-ON EE-SPW411
Infrared li
g
ht
1m
EE-SPW311/411
2
Ratings and Specifications
Engineering Data (Typical)
Item Models EE-SPW311, EE-SPW411
Sensing distance 1 m
*1. The indicator is a GaP red LED
(peak wavelength: 700 nm).
*2. The response frequency was measured by
detecting the following rotating disk.
Sensing object Opaque: 5 mm dia. min.
Directional angle 5 to 20°
Light source GaAs infrared LED (pulse lighting) with a peak wavelength of 940 nm
Indicator *1Light indicator (red)
Supply voltage 5 (5%) to 24 (+10%) VDC, ripple (p-p): 5% max.
Current consumption Emitter: 20 mA max., Receiver: 20 mA max.
Control output
NPN open collector:
Load power supply voltage: 5 to 24 VDC
Load current: 100 mA max.
OFF current: 0.5 mA max.
100 mA load current with a residual voltage of 0.8 V max.
10 mA load current with a residual voltage of 0.4 V max.
Response frequency *2100 Hz min.
Ambient illumination 3,000 lx max. with incandescent light on the surface of the receiver
Ambient temperature
range
Operating: 10 to +55°C
Storage: 25 to +65°C
Ambient humidity range Operating: 5% to 85%
Storage: 5% to 95%
Vibration resistance
Destruction: 200 to 2,000 Hz (peak acceleration: 100 m/s2)
1.5-mm double amplitude for 2 h (4-min periods) each in X, Y, and Z
directions
Shock resistance Destruction: 500 m/s2 for 3 times each in X, Y, and Z directions
Degree of protection IEC IP60
Connecting method Special connector (soldering not possible)
Weight (packaged) Approx. 8.8 g
Material Case Polybutylene phthalate (PBT)
Lens Polycarbonate
Accessories EE-1006L/D Connectors with Cables, Instruction Manual
Receiver Output Excess Gain Vs.
Sensing Distance Characteristics
Parallel Movement Characteristics
1 m
Optical axis
5 mm5 mm
5 mm
1,000
500
300
100
50
30
10
5
3
1
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8
Distance between sensors
(
m
)
Receiver output excess gain (multiple)
0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8
Distance X
Distance X
(
m
)
Distance Y
140
120
100
80
60
40
20
0
Distance Y (mm)
3
EE-SPW311/411
I/O Circuit Diagrams
NPN Output
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Make sure that this product is used within the rated ambient
environment conditions.
Wiring
Connection is made using a connector. Do not solder to the pins
(leads).
When extending the cable, use an extension cable with conductors
having a total cross-section area of 0.3 mm2. The total cable length
must be less than 10 m.
Axis Adjustment
(1)Tentatively mount the emitter and receiver so that the center of
each lens is in a single line.
(2)Turn ON the emitter and receiver after making sure that they have
been wired correctly. When power is turned ON, the light indicator
on the receiver will light. Make sure that the light indicator is OFF
when an object intercepts the optical axis and that the light
indicator lights again when the object is removed.
(3)Fix the position of the receiver (or emitter)
securely, move the emitter (or receiver)
horizontally and vertically to check the range in
which the operation indicator is lit. Then locate
the emitter (or receiver) in the center of the
range and fix the position securely.
Model Output
configuration Timing charts Output circuit
EE-SPW411 Light-ON
EE-SPW311 Dark-ON
WARNING
Incident
Interrupted
ON
OFF
ON
OFF
Operates
Releases
Light indicator
(red)
Output
transistor
Load 1
(relay)
Light indicator
(red)
Load
Main
circuit
OUT 5 to 24 VDC
Incident
Interrupted
ON
OFF
ON
OFF
Operates
Releases
Light indicator
(red)
Output
transistor
Load 1
(relay)
Precautions for Correct Use
Top view
Side view
EE-SPW311/411
4
(Unit: mm)
Dimensions Tolerance class IT16 applies to dimensions in this datasheet unless otherwise specified.
Sensors
Accessories (Included)
*Refer to Accessories for details.
EE-SPW311
EE-SPW411
7.4
2.54
Two, 3.2 dia. holes
0.3
0.7
Sensing
window
Sensing
window
0.6
8
25.4
7.4
6.2
27
5.5
19
19
25.4
13.4
14.1
15.1
2.54
Two, 3.2 dia. holes
0.3
0.7
Indicator window
5 dia. 5 dia.
0.6
8
1.5
27
6.2
15.1
5.5
19
13.4
19
14.1
(1) (2) (3) (1) (2) (3)
Two, 3.8 dia.
holes
Two, 3.8 dia.
holes
Emitter (EE-SPWL@11) Receiver (EE-SPWD@11)
Terminal Arrangement
(1) +Vcc
(2) --- Vacant
(3) GND (0 V)
Terminal Arrangement
(1) +Vcc
(2) OUT OUTPUT
(3) GND (0 V)
Connector with Cable for Emitter
EE-1006L
20 2,000
Vinyl-insulated round cable of 4 dia., 2 cores,
(
0.2 mm
2
with 1.1-dia. insulator
)
0.6 16.2
5.3
11.8
2.54
(1)
(2)
(3)
(4)
(1)
(2)
(3)
(4)
(1) Brown +
(4) Blue
Connector with Cable for Receiver
EE-1006D
Vinyl-insulated round cable of 4 dia., 3 cores,
(
0.2 mm
2
with 1.1-dia. insulator
)
0.6
11.8
2.54
16.2 20 2,000
5.3
(1)
(2)
(3)
(4)
(1)
(2)
(3)
(4)
(1) Brown +
(3) Black OUT
(4) Blue
Note: These cables can also be ordered separately.
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2008.11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Right Reserved.