Product Data Sheet
A Regal Brand
www.marathonsp.com 1
142X574
Replace “x with 1, 2, or 3 for number of poles
Power Terminal Block
175 Amps 600 Volts AC/DC
Wire Range
Line: (1) 2/0 - #14 AWG
Load: (1) 1/4 - 20 x 1/2
Electrical Ratings
175 Amps
600V per UL 1059 & CSA 22.2 No.158, class B & C requirements
Short circuit current ratings (SCCR): See SCCR section below for specications.
CU7AL - 75°C connector terminal rating with copper or aluminum wire
Factory & Field Wiring
Agency Compliance
UR - UL Recognized Terminal Block, Evaluated to UL 1059, File No.XCFR2.E62806
CSA - certifed to C22.2 No. 158, File No. LR19766 (wire classes B & C only)
CE compliant to IEC 60947-7-1
Material Information
Insulator base:
Phenolic
Flammability rating of insulator base UL94V0
Insulator base temperature rating: -40°C to 150°C (UL RTI)
Connector: aluminum, tin plated
Terminal screws: steel, nickel plated
Connector mounting screws: steel, zinc plated
RoHS compliant
www.marathonsp.com 2PDS 0058 REV-E 3/27/18
Termination Specications
Line Side Wire Size
(CU Stranded) Torque Wires /
Terminal Wire Class (UL) 1
2/0 - 1/0 13.6 N·m (120 lbf·in) 1 B, C
1 - 6 13.6 N·m (120 lbf·in) 1 B, C, G, H, I (DLO)
#8 4.5 N·m (40 lbf·in) 1 B, C, G, H, I (DLO)
10 - 14 4 N·m (35 lbf·in) 1 B, C
Aluminum wire range: 2/0 - #12 AWG
Solid copper wire range: #10-14 AWG
Wire strip length: 3/4 in. (19mm)
Terminal screw drive: 5/16 in. hex
1 For information on copper stranded wire classes please visit:
http://www.marathonsp.com/exible-stranded-wire.php
Load Side Termination
Type Torque Stud Length Maximum
Lug/Bar Width
Listed lugs on
1/4-20
6.9 N·m
(61 lbf·in)
0.5”
(12.7mm)
0.63“
(16mm)
For use with conductors prepared with listed connectors such as single hole compression/crimp lugs or
listed ring, fork or spade terminals.
Conductor size, ampacity, temperature rating and type are dictated by the ratings of the listed lugs utilized
and applicable code requirements.
www.marathonsp.com 3PDS 0058 REV-E 3/27/18
Short Circuit Current Ratings (SCCR)
The suitable copper conductor ranges are limited to the table values only for achieving the SCCR in excess of the default
rating of 10,000A.
Other conductor combinations within the Terminal Specications” noted are suitable for achieving a SCCR of
10,000A (the default rating of terminal blocks).
Enclosure size – Investigated with a minimum 16x12x16 enclosure. Use in smaller enclosures is subject to end use
evaluation.
Wire
Type
Suitable Copper
Conductors
Max Overcurrent Protection Fuse Required
Amp Rating / Class SCCR RMS
Sym. Amps
600V. Max
Line Load J T RK1 RK5 G CC
B, C 2/0 - 6 2/0 - 6 200 200 200 100 60 30 100,000
B, C 2/0 - 10 2/0 - 10 100 100 100 30 60 30 100,000
G, H, I 1 - 6 1 - 6 150 150 100 30 60 30 100,000
(*) 2/0 - 14 1/4 - 20 None 10,000
SCCR With Fuses
Installation & Accessories
Mounting (Panel):
For use with #10 fastener.
Mounting torques to be determined in end-use application not to exceed 30 lbf·in (3.4 N·m).
Covers:
Flat covers available upon request
Catalog Number: CC142x (replace “x with number of poles)
Covers are clear polycarbonate
Accessory covers are not intended to provide insulation for electrical spacings.
Marker Strip: white vinyl strip with mounting screws available.
Printing options available, consult customer service for specications.
* Any copper wire class evaluated (see terminal specication section)
www.marathonsp.com 4PDS 0058 REV-E 3/27/18
Drawing