Open Frame 3"X5" Universal Input AC/DC Converter Triple Output 5V/12V/24V, 40W(1) Model UPS40-2003, -1, -2, -3, -4 OUTPUT Model Main UPS40-2003 UPS40-2003-1 UPS40-2003-2 UPS40-2003-3 UPS40-2003-4 Voltage Current Rated Tolerance Min Rated Max (3) +5.0V DC +12.0V DC -12.0V DC +5.0V DC +12.0V DC -12.0V DC +5.0V DC +15.0V DC -15.0V DC +5.0V DC +12.0V DC -5.0V DC +5.0V DC +24V DC -12.0V DC +/-2.00% +/-3.00% +/-5.00% +/-3.00% +/-5.00% +/-8.00% +/-3.00% +/-5.00% +/-8.00% +/-3.00% +/-5.00% +/-8.00% +/-3.00% +/-10.00% +/-5.00% 0.6A 0.0A 0.0A 0.2A 0.0A 0.0A 0.2A 0.0A 0.0A 0.2A 0.0A 0.0A 0.2A 0.1A 0.1A 3.0A 2.0A 0.3A 3.0A 1.8A 0.3A 3.4A 1.4A 0.13A 3.2A 1.8A 0.5A 2.0A 1.0A 0.5A 5.0A 5.0A 0.5A 4.5A 1.0A 1.0A 5.0A 4.0A 1.0A 5.0A 1.0A 1.5A INPUT Voltage AC 50mV 120mV 120mV 50mV 120mV 120mV 50mV 150mV 150mV 50mV 120mV 150mV 50mV 240mV 120mV Min 90VAC Universal AC Frequency Inrush Current Ripple & Noise Regulation (4) Load 2.00% 3.00% 5.00% 3.00% 5.00% 8.00% 3.00% 5.00% 8.00% 3.00% 5.00% 8.00% 3.00% 10.00% 5.00% Nom 47Hz At Min 115 VAC Max 230 VAC Switching Frequency Fusing 2A, Slow-blow 115/230 VAC Non-User Serviceable Efficiency 65% min, at full Load 120VAC Line 0.50% 1.00% 1.00% 0.50% 1.00% 1.00% 0.50% 1.00% 1.00% 0.50% 1.00% 1.00% 0.50% 1.00% 1.00% Max 260VAC 63Hz 20A 40A 40K Hz. GENERAL SPECIFICATIONS Overvoltage Protection +5 exceeds 5.8V causes shutdown, automatic recovery. Overload Protection All outputs protected against short circuit conditions, automatic recovery. Environmental Temperature coefficient Temperature Range 0.02%/oC, All outputs Operation 0 to 50oC at rated output power. Derates linearly to 50% power at 70oC. Storage -55oC to 85oC Safety, Regulatory & EMI Agency Approvals Hi-pot EMI Autec Power Systems 685 E Cochran St, Simi Valley, CA93065 UL60950 CSA C22.2 N0.234 TUV EN60950 3750 VAC input to output for 1 minute. Meets F.C.C part 15 class 'B' conducted. www.autec.com Tel: (805)522-0888 Fax: (805)522-8777 Model UPS40-2003 PIN ASSIGNMENTS UPS40-2003, -1, -2, -3, -4 P101 CONNECTOR P102 AC INPUT PIN 1 LINE DC OUTPUT UPS40-2003 UPS40-2003-1 UPS40-2003-2 UPS40-2003-3 UPS40-2003-4 +12V +12V +15V +12V +24V PIN 2 NC +5V +5V +5V +5V +5V PIN 3 NEUTRAL +5V +5V +5V +5V +5V PIN 4 NC COM COM COM COM COM PIN 5 F.G. COM COM COM COM COM -12V -12V -15V -5V -12V MOLEX (or equiv) 09-65-2058 09-65-2068 09-65-2068 09-65-2068 09-65-2068 09-65-2068 Mating Connector 09-50-1051 09-50-1061 09-50-1061 09-50-1061 09-50-1061 09-50-1061 PIN 6 UPS40-2003 WIDTH LENGTH HEIGHT OUTLINE MOUNTING inch 3.00 5.00 1.30 mm 76.2 127.0 33.0 inch 2.54 4.55 N/A mm 64.5 115.6 N/A SHIPPING SPECIFICATIONS MODEL UNITS PER CARTON UPS40-2003 64.0 CARTON WEIGHT 19 Kgs 43.00 Lbs NOTES: 1. The power supply may be capable of more than the specified continuous and/or peak ratings, depending on the application. Consult factory Sales Engineer for feasibility. 2. Minimum load specified assures output voltage stability for all specified line voltage conditions. Full compliance to the total regulation specification may require additional loading (not to exceed 25% of rated output current). Operation at no load will not damage the power supply. 3. Each output can provide its full rated output current, provided total wattage does not exceed nominal (continuous) rating. 4. Total regulation includes the combined effects of: a) initial set point of main output of 1% max; b) line regulation for any input voltage change between 90 & 264 VAC; c) load regulation for a MIN. -100% of rated continuous load change: assumes that the total continuous power rating of the supply is not exceeded. [See Note3]. Performance during peak loading conditions is not included in the figure. 5.Units that meet VDE level B also comply with FCC level B. 6.Specifications are subject to change without notice. Autec can not be held liable foe errors or omissions or the consequences thereof. Autec Power Systems 685 E Cochran St, Simi Valley, CA93065 www.autec.com Tel: (805)522-0888 Fax: (805)522-8777