Keysight Technologies N9322C Basic Spectrum Analyzer Easy on your budget. Tough to beat performance, efficiency and simplicity. Data Sheet Definitions and Conditions Specification Learn more about the product Describes the performance of parameters covered by the product warranty and apply to the full temperature range of 5 to 45 C, unless otherwise noted. Reference these frequentlyused documents: -- Brochure (5991-1166EN) -- Introduces the product features -- Configuration Guide (5991-1168EN) -- Describes ordering information Typical For the latest revision of product related documents or more information, visit the website: www.keysight.com/find/ n9322c Indicates expected performance, or describe product performance that is useful in the application of the product, but are not covered by the product warranty. Describes additional product performance information that is not covered by the product warranty. It is performance beyond specifications that 80 percent of the units exhibit with a 95 percent confidence level over the temperature range 20 to 30 C. Typical performance does not include measurement uncertainty. Nominal The analyzer will meet its specifications when: -- It is within its calibration cycle -- It has been turned on at least 30 minutes -- It has been stored at an ambient temperature within the allowed operating range for at least two hours before being turned on; if it had previously been stored at a temperature range inside the allowed storage range, but outside the allowed operating range 2 Frequency and Time Specification Supplemental information Frequency Range Resolution Frequency reference 9 kHz to 7 GHz 1 Hz AC coupled Option PFR Standard Nominal frequency 10 MHz 10 MHz Aging rate 1 x 10-7 /Year 1 x 10-6 /Year Temperature stability 20 to 30 C 1.5 x 10-8 5 to 45 C 5 x 10-8 1 x 10-6 -8 Achievable initial calibration accuracy 4 x 10 1 x 10-6 Frequency readout accuracy (start, stop, center, marker) Marker resolution (frequency span)/(number of sweep point - 1) Uncertainty (freq indication x freq reference uncertainty 1 + 1% x span +20% x resolution bandwidth + marker resolution + 1 Hz) Sweep point 461, fixed Marker frequency counter Resolution 1 Hz Accuracy [(marker freq x freq reference RBW/Span 0.02 uncertainty 1) + (counter resolution)] (Marker level to displayed noise level > 25 dB, frequency offset = 0 Hz) Frequency span (FFT and swept mode) Range 0 Hz (zero span), 50 Hz to 7 GHz Resolution 1 Hz Accuracy (0.22% xspan + span/(sweep point -1)), nominal Sweep time and triggering Range 2 ms to 1000 s Span 100 Hz 600 ns to 1000 s Span = 0 Hz (minimum resolution = 600 ns, when RBW 30 kHz) Mode Continuous, Single Sweep time rule Accuracy or Speed Trigger Free run, video, external, RF burst Trigger slope Selectable positive or negative edge Trigger delay 12 ms to 12 s, nominal Span = 0 Hz 1. Frequency reference uncertainty = Aging rate x period since adjustment + temperature stability. 3 Frequency and Time specification (Continued) Supplemental information Time-gated sweep (Option TMG) Gate sources Gate delay range Gate length range RBW range Resolution bandwidth (RBW) Range (-3 dB bandwidth) Accuracy Resolution filter shape factor Video bandwdith (VBW) Range Accuracy External Periodic timer Sync sources include free and external Period 0 to 20 s (It should be gerater than gate delay plus gate length) Offset -5 to +5 s Resolution = 200 ns Resolution = 200 ns VBW is fixed and equal to RBW for efficiency 12 s to 10 s 84 s to 10 s 1 kHz 10 Hz to 3 MHz 5%, nominal < 5 : 1, nominal In 1-3-10 sequence < 10% when RBW = 3 MHz 60 dB/3 dB bandwidth ratio, digital, Gaussian-like 1 Hz to 3 MHz in 1-3-10 sequence 10%, nominal In 1-3-10 sequence VBW = 1 Hz to 1 MHz 4 Amplitude Specifications Supplemental information Measurement range 100 kHz to 1 MHz Displayed average noise level (DANL) to +10 dBm Preamp off 1 MHz to 7 GHz Displayed average noise level (DANL) to +20 dBm Input attenuator range 0 to 50 dB, in 1 dB steps Maximum damage level Average contunious power +33 dBm, 3 minutes maximum Input attenuator setting 20 dB, 2 MHz to 7 GHz DC voltage 50 VDC maximum Level display range Scale units dBm, dBmV, dBV, dBmV EMF, dBV EMV, V, W, V EMF Marker level readout 0.01 dB Log scale Resolution < 1% of signal level Linear scale Number of traces 4 Detectors Positive-peak, negative-peak, sample, normal, average (video, RMS, voltage) Trace function Clear/write, maximum hold, average, minimum hold Frequency response 20 to 30 C, 30% to 70% relative humidity, attenuation 20 dB, reference frequency 50 MHz 9 to 100 kHz 0.5 dB nominal Preamp off 100 kHz to 3 GHz 0.7 dB Preamp off 3 to 4 GHz 0.85 dB Preamp off 4 to 7 GHz 1.0 dB Preamp off 100 kHz to 3 GHz 0.7 dB Preamp on 3 to 4 GHz 0.9 dB Preamp on 4 to 7 GHz 1.1 dB Preamp on Input attenuation switching uncertainty at 50 MHz 20 to 30 C, attenuation 1 dB, preamp off 1 to 50 dB attenuation Typical 0.2 dB Relative to 20 dB (reference setting) Resolution bandwidth switching uncertainty 20 to 30 C, 10 Hz to 3 MHz RBW 0.1 dB, nominal Total absolute amplitude accuracy 20 to 30 C, 30% to 70% RH, peak detector, RBW 1 kHz, VBW 300 Hz, sweep time Accuracy, input signal -50 to 0 dBm, preamp off; attenuation 20 dB. Add additional 0.3 dB when sweep time rule is set to Speed At 50 MHz 0.3 dB At all frequencies (0.3 dB + frequency response) 100 kHz to 3 GHz 0.60 dB 95th percentile 3 to 4 GHz 0.65 dB 95th percentile 4 to 7 GHz 0.80 dB 95th percentile Preamp on At 50 MHz 0.4 dB At all frequencies (0.4 dB + frequency response) 100 kHz to 3 GHz 0.60 dB 95th percentile 3 to 4 GHz 0.65 dB 95th percentile 4 to 7 GHz 0.90 dB 95th percentile Preamplifier Frequency range 9 kHz to 7 GHz Gain 25 dB, nominal (100 kHz to 7 GHz) 15 dB, nominal (9 to 100 kHz) 5 Dynamic Range Specifications Supplemental information 1 dB gain compression 20 to 30 C, frequency 50 MHz, Ref level > -20 dBm Preamp off 50 to 200 MHz 200 to 500 MHz 500 MHz to 7 GHz + 2 dBm nominal + 4 dBm nominal + 7 dBm nominal Preamp on > -32 dBm nominal; total power at the preamp Displayed average noise level (DANL) Mixer power level (dBm) = input power (dBm) - input attenuation (dB) Total power at the preamp = total power at the input (dBm) - input attenuation (dB) Normalized to 1 Hz With 10 Hz RBW 20 to 30 C, input terminated 50 , 0 dB input attenuation, RBW = 1 kHz , RMS detector, average 40 Preamp off Preamp on 9 to 100 kHz -100 dBm, nominal -90 dBm, nominal 100 kHz to 1 MHz -108 dBm, -127 dBm typical -98 dBm, -117 dBm typical 1 to 10 MHz -128 dBm, -146 dBm typical -118 dBm, -136 dBm typical 10 to 500 MHz -142 dBm, -146 dBm typical -132 dBm, -136 dBm typical 500 to 2.5 GHz -141 dBm, -145 dBm typical -131 dBm, -135 dBm typical 2.5 to 4 GHz -140 dBm, -144 dBm typical -130 dBm, -134 dBm typical 4 to 6 GHz -138 dBm, -140 dBm typical -128 dBm, -130 dBm typical 6 to 7 GHz -136 dBm, -138 dBm typical -126 dBm, -128 dBm typical 9 to 100 kHz -110 dBm, nominal -100 dBm, nominal 100 kHz to 1 MHz -131 dBm, -150 dBm typical -121 dBm, -140 dBm typical 1 to 10 MHz -148 dBm, -163 dBm typical -138 dBm, -153 dBm typical 10 to 500 MHz -161 dBm, -164 dBm typical -151 dBm, -154 dBm typical 500 to 2.5 GHz -159 dBm, -162 dBm typical -149 dBm, -152 dBm typical 2.5 to 4 GHz -158 dBm, -161 dBm typical -148 dBm, -151 dBm typical 4 to 6 GHz -155 dBm, -158 dBm typical -145 dBm, -148 dBm typical 6 to 7 GHz -150 dBm, -154 dBm typical -140 dBm, -144 dBm typical Spurious response Input terminated and 0 dB input attenuation, preamp off 20 to 30 C Residual response < -90 dBm, typical -98 dBm -30 dBm signal at input mixer 20 to 30 C Input related spurious < -75 dBc Exceptions: -65 dBc (F1 - 21.4 MHz, with F1 input frequency) -65 dBc (F1 - 5.35 MHz, with F1 input frequency) -65 dBc (F1 = 4155 MHz, with F1 input frequency) Mixer signal level at -30 dBm, input attenuation 0 dB, preamp off, 20 to 30 C Second harmonic distortion 50 MHz to 3 GHz < -65 dBc 3 to 7 GHz < -70 dBc Two -20 dBm tones at input mixer, spaced by 100 kHz, input attenuation 0 dB, preamp off, reference level > -20 dBm, 20 to 30 C Third-order intercept (TOI) 50 to 300 MHz +9 dBm, +12 dBm typical 300 MHz to 7 GHz +11 dBm, +15 dBm typical Phase noise Specification Typical 20 to 30 C, center frequency = 1 GHz Offset from CF signal 10 kHz < -98 dBc/Hz < -100 dBc/Hz 1 MHz < -119 dBc/Hz < -121 dBc/Hz Residual FM 20 to 30 C, RBW 100 Hz, VBW 100 Hz < -90 dBc/Hz 100 kHz 10 Hz p-p in 20 ms, nominal Tracking Generator (Option TG7) Supplemental information Output frequency Range 5 MHz to 7 GHz Resolution 1 Hz Resolution bandwidth 3 kHz to 3 MHz Output power level Range -20 to 0 dBm Resolution 1 dB Output flatness 2 dB, nominal VSWR < 2 : 1, nominal Dyanmic range Max. output power - DANL with 3 kHz RBW Connector and impedance N-type female, 50 Maximum safe reverse level Average total power 30 dBm (1W) DC voltage 50 VDC Reflection measurement (Option RM7, requires Option TG7) Frequency range 5 MHz to 7 GHz Frequency resolution 100 kHz Output power -4 to +2 dBm, nominal Measurement speed 2 s (full span 5 MHz to 7 GHz) Number of data points 461 Directivity of calibrator > 40 dB Return loss Range 0 to 60 dB Accuracy 20 x log 10 (1.1 + 10 (- (D-RL)/20) + 0.016 x 10 (-RL/20) + 10 (-3 +RL/20)) D: Directivity of calibrator RL: Return loss value of the DUT Resolution 0.01 dB Voltage standing wave ratio Range 1 to 65 Resolution 0.01 Accuracy Refer to return loss accuracy Insertion loss Range 0 to 30 dB Resolution 0.01 dB Distance-to-fault (DTF) Vertical range 0 to 60 dB 1 to 65 Range (Number of data points - 1) x resolution Resolution (meter) (1.5 x 10 8) x (VP)/(F2 - F1) Hz Immunity to interference On-channel On-frequency +17 dBm, nominal -5 dBm, nominal 7 5 MHz to 7 GHz, input attenuator 12 dB Mechanical OSL calibrator Nominal, after average Return loss VSWR Number of data points = 461 VP is the cable's relative propagation velocity F2 is the stop frequency F1 is the start frequency Other Options Supplemental information AM/FM modulation analysis (Option AMA) Frequency range 10 MHz to 7 GHz Carrier power accuracy 1.8 dB, nominal Carrier power range -30 to +10 dBm 100 kHz to 2 MHz -30 to +20 dBm 2 MHz to 7 GHz Carrier power displayed resolution 0.01 dBm AM measurement (included in Option AMA) Modulation rate 20 Hz to 100 kHz Accuracy 1 Hz, nominal Modulation rate < 1 kHz < 0.1% modulation rate, nominal Modulation rate 1 kHz Depth 5 to 95% Accuracy 4%, nominal FM measurement (included in Option AMA) Modulation rate 20 Hz to 200 kHz Accuracy 1 Hz, nominal Modulation rate < 1 kHz < 0.1% modulation rate, nominal Modulation rate 1 kHz Deviation 20 Hz to 400 kHz Accuracy 4%, nominal ASK/FSK modulation analysis (Option DMA) Frequency range 2.5 MHz to 6 GHz Carrier power accuracy 2 dB, nominal Carrier power range -30 to +20 dBm, nominal Carrier power displayed resolution 0.01 dBm ASK measurement (included in Option DMA) Symbol rate range 100 Hz to 100 kHz Modulation depth/index range 5 to 95% Accuracy 4% of reading, nominal Displayed resolution 0.1% FSK measurement (included in Option DMA) FSK deviation 100 Hz to 400 kHz Symbol rate range 100 Hz to 20 kHz 1 20 ( is the ratio of frequency deviation to symbol rate (deviation/rate)) 20 to 50 kHz 18 50 to 100 kHz 14 Accuracy 4%, nominal Displayed resolution 0.01 Hz Channel scanner (Option SCN) Scan modes Top N, bottom N, and list Channels displayed 1 to 20 Displayed orientation Vertical Number of channels 5 Horizontal Number of channels > 5 Chart Bar chart, and time chart Log file *.csv Spectrum monitor (Option MNT) Display modes Spectrogram Spectrum trace Combination of spectrogram and spectrum trace in one screen Other Options (Continued) Supplemental information Security features (Option SEC) Security erase method Erase the entire user flash memory by writing single character "1" over all memory locations Port control Disable or enable LAN or USB connectors Non-recoverable Task planner (Option TPN) Task plan execution mode Auto, manual, and manual if fail Task plan file *.TPN Number of tasks Maximum 20 in a single .TPN file Measurements supported Regular spectrum analysis and power suite (channel power, ACPR and OBW) Complementary task plan editor is available with Keysight HSA and BSA PC software For more information, visit www.keysight.com/find/taskplanner USB average power sensor support (Option PWM) Power sensor supported Keysight U2000 Series USB power sensor Frequency range 9 kHz to 24 GHz Sensor dependent Dynamic range -60 to +44 dBm Sensor dependent USB peak and average power senesor support (Option PWP) Power sensor supported Keysight U2020 X-Series USB peak and average power sensor Frequency range 50 MHz to 40 GHz Dynamic range -30 to +20 dBm Sensor dependent Base band input (Option BB1) Frequency range 9 kHz to 10 MHz Frequency span 100 Hz to 9.997 MHz Frequency resolution 1 Hz Measurement range DANL to +10 dBm (9 kHz to 2 MHz) DANL to +20 dBm (2 MHz to 10 MHz) Overall amplitude accuracy 20 to 30 C, 30 to 70% RH, peak detector, input signal -50 to 0 dBm, 95th percentile 9 to 100 kHz 2.5 dB 100 kHz to 10 MHz 1.5 dB Displayed average noise level 20 to 30 C, 30 to 70% RH, 10 Hz RBW, 1 Hz VBW, 50 termination on input, 0 dB attenuation, RMS detector, Trace average > 40, reference level < -35 dBm 9 to 100 kHz -135 dBm, nominal 100 kHz to 10 MHz -145 dBm Residual response < -120 dBm, nominal 20 to 30 C, Ref level < -35 dBm 50 termination on input, 0 dB attenuation 9 Other Options (Continued) Supplemental information Base band input (Option BB1) - Continued Phase noise Fc = 5 MHz, RBW = 1 kHz, VBW = 30 Hz. Ref level -30 dBm, input attenuation 0 dB, input signal -20 dBm, average > 40 Offset 30 kHz -120 dBc/Hz, nominal Offset 100 kHz -127 dBc/Hz, nominal Offset > 200 kHz -130 dBc/Hz, nominal Second harmonic distortion F > 100 kHz, signal level -30 dBm, ref level -30 dBm, attenuation 0 dB < -55 dBc nominal Third order intermodulation distortion F > 100 kHz, -20 dBm tones at 100 kHz apart, ref level -20 dBm, attenuation 0 dB < -55 dBc, nominal 10 Inputs and Outputs Supplemental information Front panel RF input connector N-type female, 50 , nominal VSWR < 1.5 : 1, nominal 10 MHz to 3 GHz < 2.0 : 1, nominal 3 to 7 GHz Amplitude -25 0.25 dBm Frequency 40 MHz Connector and impedance BNC-type female, 50 , nominal Voltage/Current +15 V, 150 mA maximum Calibration output Probe power -12.6 V, 150 mA maximum RF output connector N-type female, 50 , nominal USB interface (host) A plug, version 1.1 Option TG7 installed Rear panel 10 MHz reference output 10 MHz reference input External trigger input Output amplitude > 0 dBm Frequency 10 MHz (10 MHz x frequency reference accuracy) Connector and impedance BNC-type female, 50 , nominal Input amplitude -5 to +10 dBm, nominal Frequency 10 MHz Connector and impedance BNC-type female, 50 , nominal Input amplitude 5 V TTL level; -12.6 V, 150 mA max (nominal) Connector and impedance: BNC-type female, 10 k LAN TCP/IP interface 100Base-T, RJ-45 connector USB interface (device) B plug, version 1.1 Mini USB (device) Mini-AB female, version 1.1 GPIB interface IEEE-488 bus connector Optional G01 installed 11 Input attenuator 10 dB, or 20 dB fixed attenuation General Supplemental information Temperature and relative humidity Operating temperature range +5 to +45 C Storage temperature range -20 to +70 C Relative humidity < 95% EMC Complies with European EMC Directive 2004/108/EC IEC/EN 61326-1 / IEC/EN 61326-2-1 CISPR Pub 11 group 1, class A AS/NZS CISPR 11:2004 ICES/NMB-001:2006 This ISM device complies with Canadian ICES-001 Cet appareil ISM est conforme a la norme NMB-001 du Canada Safety Complies with European Low Voltage Directive 2006/95/EC * IEC/EN 61010-1 3rd Edition * Canada: CSA C22.2 No. 61010-1-04 * USA: UL 61010-1 2nd Edition Audio noise Acoustic noise emission Geraeuschemission LpA < 70 dB LpA < 70 dB Operator position Am Arbeitsplatz Normal position Normaler Betrieb Per ISO 7779 Nach DIN 45635 t.19 Environmental stress Samples of this product have been type tested in accordance with the Keysight Environmental Test Maunal and verified to be robust against the environmental stresses of storage, transportation, and end-use; those stresses include, but are not limited to, temperature, humidity, shock, vibration, altitude, and power line conditions. Test methods are aligned with IEC 60068-2 and levels are similar to MILPRF-28800F Class 3 Power requirements Voltage and frequency (nominal) 100 to 240 VAC, 50 to 60 Hz Power consumption 25 W, < 20 W, typical Auto ranging Display Resolution 640 x 480 Size 165.1 mm (6.5 inch) diagonal (nominal) Data storage Internal 64 MB nominal External Supports USB 3.0 compatible memory devices Weight (without options) Net 7.9 kg (17.4 lbs), nominal Shipping 14.5 kg (30.9 lbs), nominal Dimensions Height 132.5 mm (5.2 inch) Width 320 mm (12.6 inch) Length 400 mm (15.7 inch) Occupies 3U height in a rack Warranty The N9322C spectrum analyzer is supplied with a three-year warranty Calibration cycle The recommended calibration cycle is one year. Calibration services are available through Keysight service centers 13 | Keysight | N9322C Basic Spectrum Analyzer - Data Sheet myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA(R) Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Keysight is a founding member of the AXIe consortium. ATCA(R), AdvancedTCA(R), and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. www.pxisa.org PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight's commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight's measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/n9322c For more information on Keysight Technologies' products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 55 11 3351 7010 001 800 254 2440 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 6375 8100 Europe & Middle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia Spain Sweden Switzerland United Kingdom 0800 001122 0800 58580 0800 523252 0805 980333 0800 6270999 1800 832700 1 809 343051 800 599100 +32 800 58580 0800 0233200 8800 5009286 0800 000154 0200 882255 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-07-01-14) This information is subject to change without notice. (c) Keysight Technologies, 2014 Published in USA, August 4, 2014 5991-1167EN www.keysight.com