f_9
All specifications are subject to change without notice.
RPA
FEATURES
This product provides superior attenuation for both differential mode and common mode noise.
Amorphous core is used as the common mode coil core for the RPE series, which helps prevent devise error.
Leakage current of standard type is 0.5 mA max and also lineup low-leakage current characteristic type is 0.01 mA max.
Faston terminal #250 (t=0.8mm).
Compliant with RoHS directives.
SAFETY STANDARDS
UL1283 UL File No. E62388
CSA C22.2 No.8 (cUL) File No. E62388
EN60939 certicate No. P12215895
PRODUCT IDENTIFICATION
RPA‒2**□
N/A:Standardtype
R:Withdischargeresistortype
L:Low-leakagecurrentcharacteristictype
RL:Withdischargeresistor・Low-leakagecurrentcharacteristictype
Ratedcurrent
Numberindicatingtheratedvoltage
Seriesname
Single-Phase Filter with Inlet Socket Type for High-Voltage Pulse Noise
Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based
flame retardants, PBB and PBDE, have not been used, except for exempted applications.
RPA SERIES
web161012
f_10
All specifications are subject to change without notice.
RPA
CIRCUIT DIAGRAM
R PA - 2 *** R PA - 2 *** L
R PA - 2 *** R R P A - 2 *** R L
PANEL INSTALLATION MEASUREMENT
From back side panel From front panel
ELECTRICAL CHARACTERISTICS
R PA - 2 ***/ R
RPA-2 L/RL
1
2
4
3
1
2
4
3
1
2
4
3
1
2
4
3
30.7
40
ø3.5R5 max.
22.7
28.8
40
M3 or ø3.5R3 max.
21.5
PartNo.
RPA-2003
RPA-2006
RPA-2003R
RPA-2006R
Rated
voltage
(AC/DC)
Rated
current
(AC/DC)
3A
6A
3A
6A
Withstand
voltage
Insulation
resistance
Leakage
current
Operating
temperature
range
With
derating
over
DC
resistance
(mΩ)
150max.
100max.
150max.
100max.
Weight
(g)
40
40
40
40
Commonmode
2to30
3to30
2to30
3to30
Attenuationfrequencyrange(MHz)
Differentialmode
3to30
5to30
3to30
5to30
AC.1500V
60s
[line-earth]
100MΩ
min.
[DC.500V/
1min]
0.5mA
max.
[250V/60Hz]
250V -25to+85℃55℃
at25dB at25dB
PartNo.
RPA-2003L
RPA-2006L
RPA-2003RL
RPA-2006RL
Rated
voltage
(AC/DC)
Rated
current
(AC/DC)
3A
6A
3A
6A
Withstand
voltage
Insulation
resistance
Leakage
current
Operating
temperature
range
With
derating
over
DC
resistance
(mΩ)
150max.
100max.
150max.
100max.
Weight
(g)
40
40
40
40
Commonmode
0.4to10
0.5to8
0.4to10
0.5to8
Attenuationfrequencyrange(MHz)
Differentialmode
1to30
2to30
1to30
2to30
AC.1500V
60s
[line-earth]
100MΩ
min.
[DC.500V/
1min]
0.01mA
max.
[250V/60Hz]
250V -25to+85℃55℃
at25dBat25dB
f_11
All specifications are subject to change without notice.
RPA
DERATINGS
SHAPES AND DIMENSIONS
120
100
80
60
40
20
0
Ratedcurrent(%)
–25 –10 0102030405060708
090
AmbienttemperatureTa(℃)
2.8
ø3.3
ø6.0
13.3
27.9
14.238.76.0
58.8
30.0
50.0
40.0
22.4
20.1
22.2
2x4
7.5
4.6
Dimensionsinmm
f_12
All specifications are subject to change without notice.
RPA
ATTENUATION vs. FREQUENCY CHARACTERISTICS
RPA-2003/RPA-2003R RPA-2006/RPA-2006R
RPA-2003L/RPA-2006RL RPA-2006L/RPA-2006RL
PULSE ATTENUATION CHARACTERISTICS
RPA-2003/RPA-2003R RPA-2006/RPA-2006R
RPA-2003L/RPA-2006RL RPA-2006L/RPA-2006RL
–100
–90
–80
–70
–60
–50
–40
–30
–20
–10
0
0.1 110
100
Attenuation(dB)
Frequency(MHz)
Differential mode
Common mode
–100
–90
–80
–70
–60
–50
–40
–30
–20
–10
0
0.1 110
100
Attenuation(dB)
Frequency
(
MHz
)
Differential mode
Common mode
–100
–90
–80
–70
–60
–50
–40
–30
–20
–10
0
0.1 110
100
Attenuation(dB)
Frequency
(
MHz
)
Differential mode
Common mode
–100
–90
–80
–70
–60
–50
–40
–30
–20
–10
0
0.1 110
100
Attenuation(dB)
Frequency(MHz)
Differential mode
Common mode
0
100
150
50
200
250
0500 1000 1500 2
(
)
Pulse width:0.4µs
Pulse width:0.1µs
Common mode
Differential mode
0
100
150
50
200
250
0500 1000 1500 2
(
)
Pulse width:0.4µs
Pulse width:0.1µs
Common mode
Differential mode
0
100
150
50
200
250
0500 1000 1500 2
Pulse width:0.4µs
Pulse width:0.1µs
Common mode
Differential mode
0
100
150
50
200
250
0500 1000 1500 2
Pulse width:0.4µs
Pulse width:0.1µs
Common mode
Differential mode