RY/RM
Relays & Sockets
1705151135
Specications
Contact Model Standard Contact
RY2 - DPDT Slim RM2 - DPDT Wide RY4 - 4PDT
Contact Material Gold-plated silver Silver Gold-plated silver
Contact Resistance 150 mΩ maximum 30 mΩ maximum 50 mΩ maximum
Minimum Applicable Load 24V DC, 5 mA; 5V DC,
10 mA (reference value)
24V DC, 10 mA; 5V DC,
20 mA (reference value)
24V DC, 5 mA; 5V DC,
10 mA (reference value)
Operating Time 220 ms maximum
Release Time 220 ms maximum
Power Consumption
(approx.)
AC: 1.1 VA (50 Hz), 1 VA (60 Hz)
DC: 0.8W
AC: 1.4 VA (50 Hz), 1.2 VA (60 Hz)
DC: 0.9W
AC: 1.4 VA (50 Hz), 1.2 VA (60 Hz)
DC: 0.9W
Insulation Resistance 100 MΩ minimum (500V DC megger)
Dielectric Strength
Between live and dead parts:
1500V AC, 1 minute 2000V AC, 1 minute 2000V AC, 1 minute
Between contact and coil:
1500V AC, 1 minute 2000V AC, 1 minute 2000V AC, 1 minute
Between contacts of different poles:
1500V AC, 1 minute 2000V AC, 1 minute 2000V AC, 1 minute
Between contacts of the same pole:
1000V AC, 1 minute 1000V AC, 1 minute 1000V AC, 1 minute
Operating Frequency Electrical: 1800 operations/h maximum
Mechanical: 18,000 operations/h maximum
Vibration Resistance Damage limits: 10 to 55 Hz, amplitude 0.5 mm
Operating extremes: 10 to 55 Hz, amplitude 0.5 mm
Shock Resistance Damage limits: 1000 m/s2
Operating extremes: 100 m/s2 (DPDT Slim), 200 m/s2 (4PDT, DPDT Wide)
Mechanical Life 50,000,000 operations
Electrical Life 200,000 operations (220V AC, 3A) 500,000 operations (220V AC, 5A) 100,000 operations (220V AC, 5A)
200,000 operations (220V AC, 3A)
Operating Temperature 3–25 to +55°C (no freezing) –25 to +45°C (no freezing) –25 to +55°C (no freezing) 4
Operating Humidity 45 to 85% RH (no condensation)
Weight (approx.) 23g 35g 34g
Note: Above values are initial values.
1. Measured using 5V DC, 1A voltage drop method
2. Measured at the rated voltage (at 20°C), excluding contact bouncing
Release time of relays with diode: 40 ms maximum
3. For use under different temperature conditions, refer to Continuous Load
Current vs. Operating Temperature Curve. The operating temperature range
of relays with indicator or diode is –25 to +40°C.
4. When the total current of 4 contacts is less than 15A, the operating
temperature range is –25 to +70°C.