h
C
Ch
hi
ip
p
R
Re
es
si
is
st
to
or
r
Performance Specifications
Characteristics
Test Methods Limits
± 5% 1Ω --- 10Ω ≤ ± 400PPM/
11Ω --- 10MΩ ≤ ± 200PPM/
Temperature
coefficient
JIS – C – 5202 5.2
Natural resistance change per temp. degree centigrade
R
2 – R
1
x 106 (PPM / )
R
1(t2-t1)
R
1 : Resistance value at room temperature (t1)
R
2 : Resistance value at room temp. plus 100 (t2)
± 1% 10Ω --- 100Ω ≤ ± 200PPM/
101Ω --- 1MΩ ≤ ± 100PPM/
Short – time overload
JIS – C – 5202 5.5
Permanent resistance change after the application of a potential
of 2.5 times RCWV for 5 seconds.
± 5% Tolerance ±( 2.0% + 0.1Ω )
± 1% Tolerance ±( 1.0% + 0.1Ω )
Insulation resistance
JIS – C – 5202 5.6
Apply 500V DC between protective coating and termination for 1
min, then measure. 1,000 Mega ohm or more
Dielectric
withstanding voltage
JIS – C – 5202 5.7
Apply 500V AC between protective coating and termination for 1
minute.
No evidence of flashover mechanical
damage, arcing or insulation break
down
Terminal bending
JIS – C – 5202 6.1.4
Twist of Test Board: Y / X = 5 / 90mm for 10 seconds. ± ( 1.0% + 0.05Ω )
Soldering Heat
JIS – C – 5202 6.4
Dip the resistor into a solder bath having a temperature of 260 ±
5 and hold it for 10 ± 1 seconds.
Resistance change rate is
± ( 1.0%+0.05Ω )
Solderability
JIS – C – 5202 6.5
Test temperature of solder 235 ± 5 .
Dipping them in solder: 3 ± 0.5 seconds. 95% coverage Min.
Resistance change after continuous five cycles for duty cycle
specified below:
Step Temperature Time
1 −55 ± 3 30 mins.
2 Room temp. 10 – 15 mins.
3 +125 ± 2 30 mins.
Temperature cycling
JIS – C – 5202 7.4
4 Room temp. 10 – 15 mins.
±5% Tolerance ± ( 1.0% + 0.05Ω )
±1% Tolerance ± ( 0.5% + 0.05Ω )
Load life in humidity
JIS – C – 5202 7.9
Resistance change after 1,000 hours (1.5 hours “ on”, 0.5 hour
“ off”) at RCWV in a humidity chamber controlled at 40 ± 2
and 90 to 95% relative humidity.
±5% Tolerance ± ( 3.0% + 0.1Ω )
±1% Tolerance ± ( 1.0% + 0.1Ω )
Load Life
JIS – C – 5202 7.10
Permanent resistance change after 1,000 hours operating at
RCWV, with duty cycle (1.5 hours “ on”, 0.5 hour “ off” ) at 70 ±
2 ambient
±5% Tolerance ± ( 3.0% + 0.1Ω )
±1% Tolerance ± ( 1.0% + 0.1Ω )
*RCWV = Rated Continuous Working Voltage = Rated Power × Resistance Value