DC-DC CONVERTERS 8-10 W Wide Input DC-DC Converters 1
2 YEAR WARRANTY
BXA10 Series
Single and dual output
1 x 2 x 0.395 inch package with stand-offs
13.3 Watts/in3power density
CISPR22 and EN55022 conducted emission level A
UL, CSA and VDE approvals (48V input only)
Continuous short circuit protection
Optional remote ON/OFF
Available RoHS compliant
The BXA10 series of dc-dc converters, comprising 7 different models, is designed for
a wide range of applications including communications, industrial systems and mobile
battery powered systems. Packing up to 10 Watts of power into a 2 x 1 x 0.395 inch
package, with efficiencies as high as 85%, the BXA10 has wide input ranges of 9 Vdc
to 18 Vdc and 18 Vdc to 75 Vdc, and is available in single and dual output versions.
Isolation of 1500 Vdc, approval to EN60950 2nd edition, coupled with reduced
conducted noise for simplified compliance to FCC Part 15 level A and EN55022 level
A, make the BXA10 ideal for telecommunications and distributed power applications.
Other features include overvoltage protection, continuous short circuit protection with
automatic recovery and remote on/off, all of which minimize the need for external
circuitry and make the BXA10 a recommended component in distributed power
systems.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
EMC CHARACTERISTICS
Conducted emissions EN55022, FCC (See Note 8) Level A
ESD air EN61000-4-2, level 2 Perf. criteria 1
ESD contact EN61000-4-2, level 3 Perf. criteria 1
Surge EN61000-4-5, level 2 Perf. criteria 1
Fast transients EN61000-4-4, level 2 Perf. criteria 1
Radiated immunity EN61000-4-3, level 3 Perf. criteria 1
Conducted immunity EN61000-4-6, level 3 Perf. criteria 1
GENERAL SPECIFICATIONS
Efficiency See table
Isolation voltage Input/output 1500 Vdc
Input or output to case 1000 Vdc
Switching frequency Fixed 400 kHz
Approvals and Safety VDE0805, EN60950, IEC950
standards UL1950, CSA C22.2 No. 950
Case material Black coated, six-sided metal case
Material flammability UL94V-0
Weight 20 g (0.71 oz)
MTBF MIL-HDBK-217F 519,000 hours
Bellcore >2 million hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating ambient -25 °C to +71 °C
(See derating curve)
Non-operating amb. -55 °C to +125 °C
Case +110 °C max.
Derating See derating curve
Cooling Free air convection cooled
Relative humidity Non-condensing 5% to 95% RH
Altitude Operating 10,000 feet max.
Non operating 40,000 feet max.
Vibration 5-500 MHz 2.5 G rms (approx.)
SPECIFICATIONS
File Name: bxa10.pdf Rev (2): 08 Dec 2005
OUTPUT SPECIFICATIONS
Line regulation LL to HL, single output ±0.2%
LL to HL, dual output ±0.2%
Load regulation 10% to 100% FL (See Note 4) ±0.5%
Minimum load 48 V models 10% full load
12 V models No minimum load
Overshoot At start-up 10% max.
Ripple and noise 5 Hz to 20 MHz 100 mV pk-pk, max.
(See Note 2) 20 mV rms
Transient response 25% load step ±2.0% max. dev.,
250 µs recovery
to within ±1.0%
Temperature coefficient ±0.02%/°C max.
Overvoltage protection Clamp type See table
Short circuit protection Hiccup Continuous
automatic recovery
INPUT SPECIFICATIONS
Input voltage range 12 Vdc (See Note 6) 9-18 Vdc
48 Vdc 18-75 Vdc
Input filter Pi type
Start up surge current Resistive load 1.5 A max.
Remote ON/OFF Open collector compatible
ON (See Note 3) High impedance >400 kΩ
OFF Low impedance <1.0 kΩ
OFF idle current <1.5 mA
Start-up time 1.6 s, max.
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
NNootteess
1At nominal input and output voltage and maximum load.
2Output ripple can be reduced to <50 mV with the addition of a 33 µF,
25 V, AVX-TPS (or equivalent) tantalum capacitor. Consult factory for
further information.
3For units with optional remote ON/OFF, please add the suffix ‘-S’ to the
model number: e.g. BXA10-48S05-SJ. Maximum open pin voltage 14
Vdc.
4Assumes balanced loads on dual output models.
5High impedance source/long input power cable may necessitate the
introduction of an input filter.
6Typical 9 Vdc to 18 Vdc model start-up voltage is 9 V. Maximum start-up
voltage is 9.5 V (>0 °C) or 9.7 V (<0 °C).
7It is recommended that an IEC127, 250 V, fast blow fuse is used rated at
4 A for nominal 12 V models and 2 A for 48 V models.
8To achieve compliance to EN55022-A and FCC part 15 Class A, external
capacitors of the following values are needed:
Model C1* C2 C3
BXA10-12xxxx 10 µF film, 25 V 0.22 µF film 0.22 µF film
BXA10-48xxxx 10 µF film, 100 V 0.22 µF film 0.22 µF film
(C2, C3 voltage rating application dependent)
* Siemens P.N. B32512-J1106-J or equivalent.
9The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
10 NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
BXA10 Series
Single and dual output
DC-DC CONVERTERS 8-10 W Wide Input DC-DC Converters 2
File Name: bxa10.pdf Rev (2): 08 Dec 2005
* Optional remote ON/OFF pin. Add Suffix ‘-S’ to the model number (Note 3).
INPUT OUTPUT OUTPUT INPUT TYPICAL
OVP
REGULATION (Typ.) MODEL
VOLTAGE VOLTAGE CURRENT CURRENT (1) EFFICIENCY LINE LOAD NUMBER (3,9,10)
9-18 Vdc 5 V 2 A 1.1 A 81% 6.2 Vdc ±0.2% ±0.5% BXA10-12S05J
9-18 Vdc 15 V 0.67 A 1.05 A 85% 18 Vdc ±0.2% ±0.5% BXA10-12S15J
9-18 Vdc ±5 V ±1 A 1.05 A 81% 12 Vdc ±0.2% ±0.5% BXA10-12D05J
18-75 Vdc 5 V 2 A 0.26 A 82% 6.8 Vdc ±0.2% ±0.5% BXA10-48S05J
18-75 Vdc ±5 V ±1 A 0.26 A 82% 12 Vdc ±0.2% ±0.5% BXA10-48D05J
18-75 Vdc ±12 V ±0.416 A 0.25 A 84% 30 Vdc ±0.2% ±0.5% BXA10-48D12J
18-75 Vdc ±15 V ±0.333 A 0.25 A 84% 36 Vdc ±0.2% 0.5% BXA10-48D15J
PIN CONNECTIONS
PIN NUMBER SINGLE OUTPUT DUAL OUTPUT
1 +Vin + Vin
2 – Vin – Vin
3 + Vout + Vout
4 No Pin Common
5 – Vout – Vout
6* Remote ON/OFF Remote ON/OFF
+ Input
Input Return
C1
C2 C3
Ground Plane
BXA10
100%
Ambient Temperature (˚C)
Output Power (%)
0%
0ºC 20ºC 40ºC 60ºC 80ºC 100ºC 120º C
-25ºC
110ºC
DERATING CURVE
Output Power (Watts)
71ºC
BOTTOM VIEW
2.0
(50.8) 0.8
(20.4)
0.6
(15.2)
0.4
(10.2)
0.2
(5.1)
0.3
(7.6)
1.00 (25.4)
0.040 Dia. (1.0)
0.020
(0.5)
0.395 (10.03)
max.
0.4
(10.2)
0.1
(2.5)
345
621
0.135 ± 0.010
(3.4 ± 0.2)
0.4
(10.2)
ALL DIMENSIONS IN INCHES (mm)
BOTTOM VIEW
Datasheet © Artesyn Technologies
®
2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
BXA10 Series
Single and dual output
DC-DC CONVERTERS 8-10 W Wide Input DC-DC Converters 3
www.artesyn.com
File Name: bxa10.pdf Rev (2): 08 Dec 2005
MMeecchhaanniiccaall NNootteess
ARecommended PCB hole diameter is 0.052 inches (1.32 mm).
BAll pins are in true position within 0.010 inches (0.25 mm).
CTolerance (inches): .XX = ±0.02
XXX = ±0.005
International Safety Standard Approvals
VDE0805/EN60950/IEC950 File No. 10401-3336-0084
Licence No. 1812
UL1950 File No. E174104
CSA C22.2 No. 950 File No. LR41062C