Microstructure Pressure Sensors
0 psi to 1 psi through 0 psi to 100 psi ASDX Series
Sensin
g
and Control
FEATURES
ASIC enhanced output
Wide compensated
temperature range 0 °C to
85 °C [32 °F to 185 °F]
Available in absolute,
differential and gage types
Pressure ranges from
0 psi to 1 psi through
0 psi to 100 psi
Accuracy ±2 % max. Volts
Full Scale
Quantization step of 3 mV
Response time 8 ms
TYPICAL APPLICATIONS
Flow calibrators
Ventilation and air flow
monitors
Gas flow instrumentation
Dialysis equipment
Sleep apnea monitoring
and therapy equipment
Barometry
HVAC controls
Pneumatic controls
WARNING
PERSONAL INJURY
DO NOT USE these
products as safety or
emergency stop devices or
in any other application
where failure of the product
could result in personal
injury.
Failure to comply with
these instructions could
result in death or serious
injury.
The ASDX series is an amplified version of Honeywell’s proven performer
and industry leading SDX series sensor. The amplified ASDX sensor’s
footprint is slightly larger than the SDX but it offers a high level output (4.0
Vdc span) on a very cost-effective basis. This series is fully calibrated and
temperature compensated with on-board Application Specific Integrated
Circuitry (ASIC). They are intended for use with non-corrosive, non-ionic
working fluids; such as air and dry gases.
Sensors are available to measure absolute, differential, and gage pressures.
The absolute devices have an internal vacuum reference and an output
voltage proportional to absolute pressure. Differential devices allow
application of pressure to either side of the sensing diaphragm and can be
used for gauge or differential measurements.
All ASDX devices are accurate to within ± 2.0 % full scale, designed for
operation from a single 5.0 Vdc supply and are manufactured in accordance
with ISO 9001 standards.
WARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for reference only. Do
not use this document as a product installation guide.
Complete installation, operation, and maintenance information is provided
in the instructions supplied with each product.
Failure to comply with these instructions could result in death or
serious injury.
Microstructure Pressure Sensors
0 psi to 1 psi through 0 psi to 100 psi ASDX Series
2 Honeywell Sensing and Control
BLOCK DIAGRAM
ELECTRICAL CONNECTIONS(2) PIN OUT
ASDXxxxD4* ASDXxxxG2* ASDXxxxA2*
* N/C means no connection, connecting to ground will damage to sensor.
SPECIFICATIONS (Maximum Ratings)
Supply Voltage (Vs)* 4.75 Vdc to 5.25 Vdc
Maximum Supply Voltage* 6.50 Vdc (max.)
Consumption Current 6 mA (typ.)
Output Current - Sink 2 mA (max.)
Output Current - Source 2 mA (max.)
Lead Temperature 2 Sec to 4 Sec @ 250 °C [482 °F]
*Note: The sensor is not reverse polarity protected. Incorrect application of excitation voltage or ground to the wrong pin can cause
electrical failure. Application of supply voltage above the maximum can cause electrical failure.
ENVIRONMENTAL SPECIFICATIONS (ALL DEVICES)
Temperature Ranges:
Compensated: 0 °C to 85 °C [32 °F to 185 °F]
Operating: -20 °C to 105 °C [-4 °F to 221 °F]
Storage: -40 °C to 125 °C [-40 °F to 257 °F]
Vibration: 10 g at 20 Hz to 2000 Hz
Shock: 50 g for 11 ms
Life: 1 million cycles minimum
PRESSURE RANGE SPECIFICATIONS
Part No. Pressure Range Burst Pressure (3) Sensitivity
ASDX001 0 psi to 1 psi 5 psi 4.00 V/psi
ASDX005 0 psi to 5 psi 20 psi 0.80 V/psi
ASDX015 0 psi to 15 psi 30 psi 0.267 V/psi
ASDX030 0 psi to 30 psi 60 psi 0.133 V/psi
ASDX100 0 psi to 100 psi 150 psi 0.040 V/psi
Microstructure Pressure Sensors
0 psi to 1 psi through 0 psi to 100 psi ASDX Series
Honeywell Sensing and Control 3
PERFORMANCE SPECIFICATIONS(4)
Characteristic Symbol Min. Typ. Max. Units
Zero Pressure Offset Voff 0.420 0.500 0.580 Vdc
Full Scale Span(5) Vfss 4.00 Vdc
Output at FS Pressure Vfso 4.420 4.500 4.580 Vdc
Accuracy(6)±2.0 % Vfs
Response Time(7) – 8 – ms
Quantization Step(8) – 3 – mV
SPECIFICATION NOTES
Note 1: Capacitor 220 nF required between +Vs and GND pin.
Note 2: Pins 4, 5, 6, 7 and 8 are internal device connections and should not be connected to external circuitry or ground.
Note 3: If maximum burst pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing die may
fracture.
Note 4: Reference Conditions (unless otherwise noted): Supply voltage, VS=5.0 ± 0.01 Vdc; TA=25 °C [77 °F]. Output is ratiometric within
the supply voltage range (Vs).
Note 5: Span is the algebraic difference between the output voltage at the specified pressure and the output at zero pressure. Span is
ratiometric to the supply voltage.
Note 6: Accuracy is the combined errors from offset and span calibration, linearity, pressure hysteresis, and temperature effects.
Linearity is the measured deviation based on a straight line.
Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing
pressure.
Calibration errors include the deviation of offset and full scale from nominal values.
Note 7: Response time for a 0 psi to full-scale pressure step change, 10 % to 90 % rise time.
Note 8: The smallest change in the output voltage, given any change in pressure.
PRESSURE TRANSDUCER PERFORMANCE CHARACTERISTICS
Error Band Multiplier Over -20 °C to 105 °C [-4 °F to 221 °F]
ORDERING INFORMATION - PART NUMBER DESCRIPTION
Sensor Series
Pressure Ranges
001 = 0 psi to 1 psi D, G
005 = 0 psi to 5 psi D, G
015 = 0 psi to 15 psi D, G, A
030 = 0 psi to 30 psi D, G, A
100 = 0 psi to 100 psi D, G, A
Package Style and Type
A2 = DIP Package Absolute
D4 = DIP Package Differential
D2, G2 = DIP Package, Gage
Device Output
4R = 0.5 Vdc to 4.5 Vdc
4D = 2.5 ±2.0 Vdc*
4H = 0.25 Vdc to 4.25 Vdc*
4M = 0.2 Vdc to 4.7 Vdc*
ASDX XXX XX 4X
* Contact Honeywell for additional information.
For example:
Part #ASDX015A24R=ASDX
device 15 psi absolute,
A2 Package, 0.5 Vdc to 4.5 Vdc
Output
Microstructure Pressure Sensors
0 to 1 psi through 0 to 100 psi ASDX Series
Sensing and Control
www.honeywell.com/sensing
Honeywell
11 West Spring Street
Freeport, Illinois 61032
008090-3-EN IL50 GLO 1105 Printed in USA
Copyright 2005 Honeywell International Inc. All Rights Reserved.
TO ORDER, USE THE FOLLOWING PART NUMBER(S)
Pressure Range Absolute Gauge Differential Bidirectional
0 psi to 1 psi ASDX001G24R ASDX001D44R ASDX001D44D
0 psi to 5 psi ASDX005G24R ASDX005D44R ASDX005D44D
0 psi to 15 psi ASDX015A24R ASDX015G24R ASDX015D44R ASDX015D44D
0 psi to 30 psi ASDX030A24R ASDX030G24R ASDX030D44R ASDX030D44D
0 psi to 100 psi ASDX100A24R ASDX100G24R ASDX100D44R ASDX100D44D
DIMENSIONAL DRAWINGS - For Reference Only mm [in]
D4 Package G2 Package
A2 Package
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Contact your local sales
office for warranty information. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair or
replace without charge those items it finds defective. The foregoing
is Buyer’s sole remedy and is in lieu of all other warranties,
expressed or implied, including those of merchantability and
fitness for a particular purpose.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
For application assistance, current specifications, or name of the
nearest Authorized Distributor, contact a nearby sales office. Or call:
1-800-537-6945 USA
1-800-737-3360 Canada
1-815-235-6847 International
FAX
1-815-235-6545 USA
INTERNET
www.honeywell.com/sensing
info.sc@honeywell.com