81
BHC and Evox Rifa Electrolytic Capacitors
ALS40 105°C
ARTICLE TABLE ALS40 (105°C)
Cap
(µF)
Case
Size
(mm)
ESR (mW)
at 20°C
100Hz (max)
Impedance (mW)
at 20°C
10 KHz (max)
Ripple current(A) at
105°C
Type number
100 Hz 10 KHz
450 VDC (UR )
Mounting Style 0=plain or 1=stud
Termination Style A,C,G,J,M or R
* *
150 36x52 721 360 1.8 4.5 ALS4 - - 151DA450
150 36x62 715 356 1.9 4.8 ALS4 - - 151DB450
220 36x82 487 242 2.5 6.2 ALS4 - - 221DE450
330 36x105 325 162 3.2 7.9 ALS4 - - 331DF450
470 51x82 239 123 4.1 9.0 ALS4 - - 471KE450
680 51x105 164 84 5.3 11.3 ALS4 - - 681KF450
1000 77x75 125 69 7.0 13.2 ALS4 - - 102ND450
1500 66x105 79 42 8.9 17.1 ALS4 - - 152MF450
1500 90x67 78 57 8.7 15.3 ALS4 - - 152QC450
1500 90x75 87 49 9.3 16.7 ALS4 - - 152QD450
1500 77x105 80 43 9.8 18.7 ALS4 - - 152NF450
2200 90x98 58 32 12.5 22.5 ALS4 - - 222QH450
2200 77x146 54 29 13.1 22.9 ALS4 - - 222NP450
3300 77x146 38 27 14.6 22.0 ALS4 - - 332NP450
3300 90x146 37 20 17.4 28.9 ALS4 - - 332QP450
4700 77x220 27 15 21.9 32.0 ALS4 - - 472NT450
6800 90x220 19 15 23.5 39.2 ALS4 - - 682QT450
MECHANICAL DATA
Mounting position
The capacitor can be mounted in any
position so long as the safety vent can
operate. It is possible for some electrolyte
to be expelled. As this is a conducting liquid,
suitable precautions should be instigated
by the system designer to avoid secondary
short circuits.
The capacitors are designed to be mounted
in free air and are not suitable for submersion
in liquid.
Vibration
10Hz to 55Hz at 0.75mm or 10g for 3x2hrs
duration. Except 220mm long cans 10Hz
to 55Hz at 0.35mm or 5g for 3x0.5hrs
duration.
Insulating resistance
> 100 Mohms at 100V d.c., across insulating
sleeve.
Voltage Proof
> 2500V d.c., across insulating sleeve.
Safety vent
A safety vent for over pressure is featured on
terminal deck. This is in the form of a rubber
plug designed to relieve build up of internal
pressure due to over stress or catastrophic
failure.
OPERATIONAL DATA
The failure rate is derived from our periodic
test results. The failure rate (λR) is therefore
only given at test temperature for life tests.
An estimation is also given at 40°C. The
expected failure rate for this capacitor range
is based on our periodic test results for
capacitors with structural similarity. Failure
rate is frequently quoted in FIT (Failures In
Time) where 1 FIT = 1 x 10-9 failures per hour.
Failure rates include both catastrophic and
parametric failures
Ta Failure rate per hour
85°C 220 FIT
40°C 10 FIT
RELIABILITY
Operational Lifetime
Please see separate BHC application
notes TD003 for calculating operational
life expectancy under customer specific
conditions.
Statements of suitability for certain applications are based on our knowledge of typical operating conditions for such applications, but are not intended to constitute –
and we specifically disclaim – any warranty concerning suitability for a specific customer application or use. This Information is intended for use only by customers who
have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise
provided by us with reference to the use of our products is given gratis, and we assume no obligation or liability for the advice given or results obtained.