General Safety Instructions
This is an open type switch mode po wer supply for use in applications meeting Pollution De gree 2 environment.
A suitable mechanical and fire enclosure must be provided by the end use equi pment for shock hazard
protection, fire protection and protection from hazardous energy levels.
READ SAFETY INSTRUCTIONS carefully before working on the unit.
HIGH VOLTAGE WARNING: Dangerou s voltages are present in the po wer supply.
1. Do not install, test or operate this unit near water and do not spill any liquid on it.
2. Do not operate this unit unless it is in a secu re position.
This unit must be installed and put into service by authorized competent personnel only who are fully conversant
with the hazards of AC line operated equipment and with the particular dange rs associated with switch mode
power supplies.
The output power taken from the power supply must not exceed the rating stated on the power supply label.
Refer to typical rating on power supply label for product’s real output.
In case of defect, this unit must be returned to the manufacturer.
Safety Agency Certifications
CSS500-xx, /S, /T versions
These units are approved to UL 60601-1 1st Edition, CSA 601.1-M90, IEC 60601-1:1988+A1+A2 and EN
60601-1:1990+A1+A2. EMC should be evaluated to IEC/EN 60601-1-2 in the final system.
CSS500-xx/I, /SI, /TI versions
These units are approved to UL 60950-1 2nd Edition, CSA 60950-1-07 and EN 60950-1:2006+A11.
Environmental Specifications
Storage and Transportatio n: -10°C to 85°C, 10% to 95%RH
Operating: 70°C max ambient, IPX0, Continuous, Class I, NOT evaluated as AP/APG equipm ent.
Input Rating
100-240 VAC, 6-2.5 A, 50/60 Hz