PCB Relay G6RL 197
PCB Relay
G6RL
Low-profile power relay with maximum
switching of 10 A
Low profile: 12.3 mm in height
Max. switching capacity: 2,500 VA (NO)
IEC 60947-5-1, AC-15, DC13
Clearance and creepage distance: 10 mm.
Models with high shock resistance (250 m/s2) are available.
Models for P1 load (2 × 200 W lamps parallel to ignition
transformer) are available.
RoHS Compliant
Applications:
Boilers, PLCs, I/O ports, timers, and temperature controllers
Ordering Information
Note: When ordering, add the rated coil voltage to the model number.
Model Number Legend:
1. Number of Poles
1: 1 pole
2. Contact Form/Contact Construction
None: SPDT
A: SPST-NO
3. Enclosure Rating
None: Flux protection
4: Fully sealed
4. Special Function 1
SR: Shock resistance of 25G
5. Contact material
None: AgNi
ASI: AgSnIn
6. Special Function 2
PL: P1 load (See note.)
7. Rated Coil Voltage
3, 5, 6, 12, 24, or 48
Note: Please refer to Endurance Under Real Load table in this
datasheet.
Classification Enclosure rating Contact form Contact material
AgSnIn AgNi
Standard Flux protection SPST-NO G6RL-1A-ASI G6RL-1A
SPDT G6RL-1-ASI G6RL-1
Fully sealed SPST-NO G6RL-1A4-ASI ---
SPDT G6RL-14-ASI ---
P1 Load Flux protection SPST-NO G6RL-1A-ASI-PL ---
SPDT G6RL-1-ASI-PL ---
Shock resistance Flux protection SPST-NO --- ---
SPDT G6RL-1-SR-ASI ---
Fully sealed SPST-NO --- ---
SPDT G6RL-14-SR-ASI ---
Examples: G6RL-1A DC12
Rated coil voltage
123 4 5 6 7
G6RL-@@@-@-@-@ DC@
198 PCB Relay G6RL
Specifications
Coil Ratings
Note: 1. The above items are measured at a coil temperature of 23°C.
2. The tolerance of the rated current is ±10%.
Contact Ratings
Note: 1. G6RL-1(A), G6RL-1(A)4-ASI: 8 A 250 VAC, resistive load; 5 A 24 VDC resistive load.
2. P level: λ 60 = 0.1 × 106 / operations
Characteristics
Classification Standard, P1 load Shock resistance
Rated voltage 3 VDC 5 VDC 6 VDC 12 VDC 24 VDC 48 VDC 3 VDC 5 VDC 6 VDC 12 VDC 24 VDC
Rated current 73.3 mA 44 mA 36.7 mA 18.3 mA 9.2 mA 5 mA 101 mA 60.2 mA 50.1 mA 25.2 mA 12.6 mA
Coil resistance 40 Ω113 Ω163 Ω654 Ω2,618 Ω9,600 Ω30 Ω83 Ω120 Ω476 Ω1,912 Ω
Must operate voltage 70% max. of rated voltage 80% max. of rated voltage
Must release voltage 10% min. of rated voltage 10% min. of rated voltage
Max. voltage 150% of rated voltage 150% of rated voltage (23°C)
Power consumption Approx. 220 mW Approx.
240 mW
Approx. 300 mW
Load Resistive load (cos φ = 1)
Rated load (See note 1.) 10 A at 250 VAC, NO resistive load
8 A at 250 VAC, resistive load
5 A at 30 VDC, resistive load
Rated carry current 10 A at 250 VAC
5 A at 30 VDC
Max. switching voltage 400 VAC, 300 VDC
Max. switching current NO: 10 A, NC: 8 A
Max. switching power NO: 2,500 VA, NC: 2,000 VA
150 W
Failure rate (reference value) 10 mA at 5 VDC (P level) (See note 2.)
Contact resistance 100 mΩ max.
Operate time 10 ms max. (SR Models: 15 ms max.)
Release time 5 ms max.
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 5,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
Impulse withstand voltage 10 kV between coil and contacts (1.2 × 50 μs)
Vibration resistance Destruction: 10 to 55 to 10 Hz, 1.5-mm double amplitude
Malfunction: 10 to 55 to 10 Hz, 0.825-mm single amplitude (1.65-mm double amplitude) when energized.
10 to 55 to 10 Hz, 0.4-mm single amplitude (0.8-mm double amplitude) when not energized.
Shock resistance Destruction: 1,000 m/s2
Malfunction: NO: 200 m/s2, NC: 50 m/s2 when not energized
SR Models: 250 m/s2 (NO and NC) when not energized
Endurance Mechanical: 10,000,000 operations min. (at 18,000 operations/hr)
Ambient temperature Operating: 40°C to 85°C (with no icing)
Ambient humidity Operating: 5% to 85%
Weight Approx. 7.8 g
PCB Relay G6RL 199
Other Data
Approved Standards
UL Recognized (File No. E41643) - - Ambient Temp. = 85°C
VDE (EN61810-1) (Certificate No.C266)
Note: In progress
Construction of protection Flux protection Fully sealed
Insulation material group IIIa
Rated insulation voltage 250 V
Pollution degree 32
Rated voltage system 250 V 400 V
Overvoltage category III
Creepage distance 10 mm
Clearance distance 10 mm
RoHS Compliant
Tracking index of relay base PTI 250
Flammability class according to UL94 V-0
Flammability-flame
GWFI (IEC 60695-2-12)
GWIT (IEC 60695-2-13)
850°C
750°C
Ball pressure test (IEC 60695-10-2) 170°C
Models Contact form Coil rating Contact rating
G6RL-1A SPST-NO 3 to 48 VDC 10 A at 250 VAC (NO) (Resistive)
8 A at 250 VAC (Resistive)
5 A at 30 VDC (Resistive)
6,000 operations
G6RL-1 SPDT
G6RL-1A(4)-ASI SPST-NO
G6RL-1(4)-ASI SPDT
G6RL-1(4)-SR-ASI SPDT 3 to 24 VDC
Models Contact form Coil rating Contact rating Model
G6RL-1A-(ASI) SPST-NO 3, 5, 6, 12, 24, or 48 VDC 10 A at 250 VAC (NO) 10,000 operations at 85°C
G6RL-1-(ASI) SPDT 8 A at 250 VAC 30,000 operations at 85°C
5 A at 30 VDC 50,000 operations at 85°C
G6RL-1A4-ASI (See note.) SPST-NO 3, 5, 6, 12, 24, or 48 VDC 10 A at 250 VAC (NO) 10,000 operations at 85°C
G6RL-14-ASI (See note.) SPDT 8 A at 250 VAC 10,000 operations at 85°C
5 A at 30 VDC 10,000 operations at 85°C
G6RL-1(4)-SR-ASI SPDT 3, 5, 6, 12 or 24 VDC 10 A at 250 VAC (NO) 10,000 operations at 85°C
8 A at 250 VAC 10,000 operations at 85°C
5 A at 30 VDC 10,000 operations at 85°C
200 PCB Relay G6RL
VDE (60947-5-1) (Certificate No. C266)
Note: 1. In progress
2. All ratings are valid at Room Temperature
VDE (60947-4-1) (Certificate No. C266)
Note: 1. In progress
2. All ratings are valid at Room Temperature
VDE (EN60730-1) (Certificate No. C266)
Note: In progress
Models Contact rating
Utilization category Rated voltage (V) Operations
G6RL-1(A) AC15 (NO) Ie: 3 A, Ithe: 10 A (A300) AC240 6,000
AC15 (NO) Ie: 3 A, Ithe: 5 A (B300) AC120 6,000
AC15 (NO) Ie: 1.5 A, Ithe: 5 A (B300) AC240 6,000
DC13 Ie: 0.22A, Ithe: 1A (R150) DC125 6,000
DC13 (See note.) Ie: 0.1 A, Ithe: 1 A (R300) DC250 6,000
G6RL-1(A)-ASI
G6RL-1(A)4-ASI (See note.)
G6RL-1(4)-SR-ASI
AC15 Ie: 3 A, Ithe: 10 A (A300) AC240 6,000
AC15 Ie: 3 A, Ithe: 5 A (B300) AC120 6,000
AC15 Ie: 1.5 A, Ithe: 5 A (B300) AC240 6,000
DC13 Ie: 0.22 A, Ithe: 1 A (R150) DC125 6,000
DC13 (See note.) Ie: 0.1 A, Ithe: 1 A (R300) DC250 6,000
Models Contact rating
Utilization category Rated voltage (V) Operations
G6RL-1(A)
G6RL-1(A)-ASI (See note.)
AC1 8 A AC250 6,000
AC3 2 A AC250 6,000
DC1 5 A DC24 6,000
DC3 2 A DC24 6,000
Models Contact rating
Utilization category Rated voltage (V) Operations
G6RL-1(A) 2 (2) A 65°C AC250 100,000
8 (4) A (NO) 85°C AC250 100,000
6 (4) A (NO) 85°C (See note.) AC250 100,000
6 (4)A (NO) 65°C AC250 100,000
6 (4) A (NC) 65°C AC250 100,000
G6RL-1(A)-ASI (See note.) 2 (2) A 65°C AC250 100,000
8 (4) A (NO) 85°C AC250 100,000
6 (4) A (NO) 85°C AC250 100,000
6 (4) A (NC) 65°C AC250 100,000
PCB Relay G6RL 201
Electrical Endurance Data
Endurance Under Real Load
G6RL-1(A)-ASI-PL
Note: The results shown reflect values measured using very severe test conditions, i.e., Duty: 1 s ON/OFF.
Electrical endurance will vary depending on the test conditions. Contact your OMRON representative if you require more detailed information
for the electrical endurance under your test conditions.
G6RL-1(A) 8 A at 250 VAC (cosφ = 1) NO 50,000 operations min.
8 A at 250 VAC (cosφ = 1) NC 50,000 operations min.
5 A at 24 VDC 50,000 operations min.
G6RL-1(A)-(SR)-ASI-(PL) 10 A at 250 VAC (cosφ = 1) NO 100,000 operations min.
8 A at 250 VAC (cosφ = 1) 100,000 operations min.
5 A at 30 VDC 50,000 operations min.
G6RL-1(A)4-ASI 8 A at 250 VAC (cosφ = 1) NO 50,000 operations min.
8 A at 250 VAC (cosφ = 1) NC 50,000 operations min.
5 A at 24 VDC 50,000 operations min.
G6RL-14-SR-ASI 8 A at 250 VAC (cosφ = 1) NO 50,000 operations min.
3 A at 250 VAC (cosφ = 1) NC 100,000 operations min.
5 A at 24 VDC NO 50,000 operations min.
5 A at 24 VDC NC 30,000 operations min.
(Reference Only)
Rated voltage Condition Frequency Electrical life
230 VAC P1 load (2 × 200 W lamps parallel to ignition transformer) 1.5 s ON/4.5 s OFF 250,000 operations
202 PCB Relay G6RL
Engineering Data
Dimensions
Note: All units are in millimeters unless otherwise indicated.
G6RL-1(A)(4)-(SR)-(ASI)-(PL)
Maximum Switching Capacity
G6RL-1(A)
Endurance
G6RL-1(A)(4)-(SR)-(ASI)-(PL)
Ambient Temperature vs.
Maximum Coil Voltage
G6RL-1(A)(4)-(ASI)-(PL)
Ambient Temperature vs. Must
Operate or Must Release Voltage
Note: The “maximum coil voltage” refers to the maximum value in a varying range of operating voltage, not a continuous voltage.
Switching current (A)
Switching voltage (V)
100
50
10
5
1
0.5
0.1
1 3 5 10 30 50 100 300 500 1,000
AC resistive load (N.O.)
AC resistive load (N.C.)
DC resistive load
250-VAC inductive load
(cos φ = 0.4)
250-VAC resistive load (N.O.)
Switching current (A)
0246810
1,000
10
30
50
100
300
500
Switching operations ( 103 operations)
24-VDC resistive load
Maximum coil voltage (%)
200
180
160
140
120
100
80
60
150
Ambient temperature (°C)
2320 30 40 50 60 70 80 90 10040
G6RL-1 (220 mW)
G6RL-1-SR (300 mW)
Ambient temperature (°C)
On the basis of rated voltage (%)
Sample: G6RL 24 VDC
Number of relays: 5
Must operate voltage
Must release voltage
max.
min.
X
max.
min.
X
0
20
40
60
80
100
120
40 20 0 20 40 60 80 100
(2.9) 18.9±0.1 5±0.1
(1.7)
7.62±0.1
Four, 1.3±0.1 dia.
Note: Indicates average dimensions.
Terminal Arrangement/
Internal Connections
(Bottom View)
Mounting Holes
(Bottom View)
28.5 max. 10.0 max.
0.4 0.4
0.24 0.8 0.8
3.2
12.3 max.
12
53
G6RL-1A(-ASI)
G6RL-1A4(-ASI)
G6RL-1(-ASI)
G6RL-14(-ASI)
PCB Relay G6RL
MEMO
PCB Relay G6RL
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
Cat. No. X301-E-1b Printed in USA
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
09/11 Specifications subject to change without notice
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.