Polyphase Multifunction Energy Metering IC ADE7854/ADE7858/ADE7868/ADE7878 FEATURES Highly accurate; supports EN 50470-1, EN 50470-3, IEC 62053-21, IEC 62053-22, and IEC 62053-23 standards Compatible with 3-phase, 3- or 4-wire (delta or wye), and other 3-phase services Supplies total (fundamental and harmonic) active, reactive (ADE7878, ADE7868, and ADE7858 only), and apparent energy, and fundamental active/reactive energy (ADE7878 only) on each phase and on the overall system Less than 0.1% error in active and reactive energy over a dynamic range of 1000 to 1 at TA = 25C Less than 0.2% error in active and reactive energy over a dynamic range of 3000 to 1 at TA = 25C Supports current transformer and di/dt current sensors Dedicated ADC channel for neutral current input (ADE7868 and ADE7878 only) Less than 0.1% error in voltage and current rms over a dynamic range of 1000 to 1 at TA = 25C Supplies sampled waveform data on all three phases and on neutral current Selectable no load threshold levels for total and fundamental active and reactive powers, as well as for apparent powers Low power battery mode monitors phase currents for antitampering detection (ADE7868 and ADE7878 only) Battery supply input for missing neutral operation Phase angle measurements in both current and voltage channels with a typical 0.3 error Wide-supply voltage operation: 2.4 V to 3.7 V Reference: 1.2 V (drift 10 ppm/C typical) with external overdrive capability Single 3.3 V supply 40-lead lead frame chip scale package (LFCSP), Pb-free Operating temperature: -40C to +85C Flexible I2C, SPI, and HSDC serial interfaces and harmonic) active, reactive (ADE7878, ADE7868, and ADE7858), and apparent energy measurement and rms calculations, as well as fundamental-only active and reactive energy measurement (ADE7878) and rms calculations. A fixed function digital signal processor (DSP) executes this signal processing. The DSP program is stored in the internal ROM memory. The ADE7854/ADE7858/ADE7868/ADE7878 are suitable for measuring active, reactive, and apparent energy in various 3-phase configurations, such as wye or delta services, with both three and four wires. The ADE78xx devices provide system calibration features for each phase, that is, rms offset correction, phase calibration, and gain calibration. The CF1, CF2, and CF3 logic outputs provide a wide choice of power information: total active, reactive, and apparent powers, or the sum of the current rms values, and fundamental active and reactive powers. The ADE7854/ADE7858/ADE7868/ADE7878 contain waveform sample registers that allow access to all ADC outputs. The devices also incorporate power quality measurements, such as short duration low or high voltage detections, short duration high current variations, line voltage period measurement, and angles between phase voltages and currents. Two serial interfaces, SPI and I2C, can be used to communicate with the ADE78xx. A dedicated high speed interface, the high speed data capture (HSDC) port, can be used in conjunction with I2C to provide access to the ADC outputs and real-time power information. The ADE7854/ADE7858/ADE7868/ADE7878 also have two interrupt request pins, IRQ0 and IRQ1, to indicate that an enabled interrupt event has occurred. For the ADE7868/ADE7878, three specially designed low power modes ensure the continuity of energy accumulation when the ADE7868/ADE7878 is in a tampering situation. See Table 1 for a quick reference chart listing each part and its functions. The ADE78xx are available in the 40-lead LFCSP, Pb-free package. Table 1. Part Comparison APPLICATIONS Energy metering systems GENERAL DESCRIPTION The ADE7854/ADE7858/ADE7868/ADE7878 are high accuracy, 3-phase electrical energy measurement ICs with serial interfaces and three flexible pulse outputs. The ADE78xx devices incorporate second-order sigma-delta (-) analog-to-digital converters (ADCs), a digital integrator, reference circuitry, and all of the signal processing required to perform total (fundamental Part No. ADE7878 ADE7868 ADE7858 ADE7854 WATT Yes Yes Yes Yes VAR Yes Yes Yes No IRMS, VRMS, and VA Yes Yes Yes Yes di/dt Yes Yes Yes Yes Fundamental WATT and VAR Yes No No No Tamper Detect and Low Power Modes Yes Yes No No Rev. E Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective owners. One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 www.analog.com Fax: 781.461.3113 (c)2010-2011 Analog Devices, Inc. All rights reserved. ADE7854/ADE7858/ADE7868/ADE7878 TABLE OF CONTENTS Features .............................................................................................. 1 Changing Phase Voltage Datapath........................................... 31 Applications....................................................................................... 1 Power Quality Measurements................................................... 32 General Description ......................................................................... 1 Phase Compensation ................................................................. 37 Revision History ............................................................................... 3 Reference Circuit........................................................................ 39 Functional Block Diagrams............................................................. 4 Digital Signal Processor............................................................. 39 Specifications..................................................................................... 8 Root Mean Square Measurement............................................. 40 Timing Characteristics .............................................................. 11 Active Power Calculation .......................................................... 44 Absolute Maximum Ratings.......................................................... 14 Thermal Resistance .................................................................... 14 Reactive Power Calculation--ADE7858, ADE7868, ADE7878 Only.............................................................................................. 49 ESD Caution................................................................................ 14 Apparent Power Calculation..................................................... 54 Pin Configuration and Function Descriptions........................... 15 Waveform Sampling Mode ....................................................... 57 Typical Performance Characteristics ........................................... 17 Energy-to-Frequency Conversion............................................ 57 Test Circuit ...................................................................................... 19 No Load Condition .................................................................... 61 Terminology .................................................................................... 20 Checksum Register..................................................................... 63 Power Management........................................................................ 21 Interrupts..................................................................................... 64 PSM0--Normal Power Mode (All Parts)................................ 21 Serial Interfaces .......................................................................... 65 PSM1--Reduced Power Mode (ADE7868, ADE7878 Only) 21 ADE7878 Evaluation Board...................................................... 72 PSM2--Low Power Mode (ADE7868, ADE7878 Only) ....... 21 Die Version.................................................................................. 72 PSM3--Sleep Mode (All Parts) ................................................ 22 Silicon Anomaly ............................................................................. 73 Power-Up Procedure.................................................................. 24 ADE7854/ADE7858/ADE7868/ADE7878 Functionality Issues ............................................................................................ 73 Hardware Reset........................................................................... 25 Software Reset Functionality .................................................... 25 Functionality Issues.................................................................... 73 Theory of Operation ...................................................................... 26 Section 1. ADE7854/ADE7858/ADE7868/ADE7878 Functionality Issues.................................................................... 74 Analog Inputs.............................................................................. 26 Registers List ................................................................................... 75 Analog-to-Digital Conversion.................................................. 26 Outline Dimensions ....................................................................... 93 Current Channel ADC............................................................... 27 Ordering Guide .......................................................................... 93 di/dt Current Sensor and Digital Integrator .............................. 29 Voltage Channel ADC ............................................................... 30 Rev. E | Page 2 of 96 ADE7854/ADE7858/ADE7868/ADE7878 REVISION HISTORY 4/11--Rev. D to Rev. E Changes to Input Clock FrequencyParameter, Table 2 ..............10 Changes to Current RMS Offset Compensation Section ..........42 Changes to Voltage RMS Offset Compensation Section ...........44 Changes to Note 2, Table 30...........................................................77 Changes to Address 0xE707, Table 33 ..........................................80 Changes to Table 45 ........................................................................87 Changes to Table 46 ........................................................................88 Changes to Bit Location 7:3, Default Value, Table 54.................92 2/11--Rev. C to Rev. D Changes to Figure 1...........................................................................4 Changes to Figure 2...........................................................................5 Changes to Figure 3...........................................................................6 Changes to Figure 4...........................................................................7 Changes to Table 2 ............................................................................8 Changed SCLK Edge to HSCLK Edge, Table 5 ...........................13 Change to Current Channel HPF Section ...................................28 Change to di/dt Current Sensor and Digital Integrator Section ..............................................................................................30 Changes to Digital Signal Processor Section ...............................39 Changes to Figure 59 ......................................................................44 Changes to Figure 62 ......................................................................47 Changes to Figure 65 ......................................................................49 Changes to Figure 66 ......................................................................52 Changes to Line Cycle Reactive Energy Accumulation Mode Section and to Figure 67.................................................................53 No Load Detection Based On Total Active, Reactive Powers Section ..............................................................................................61 Change to Equation 50 ...................................................................63 Changes to the HSDC Interface Section ......................................70 Changes to Figure 87 and Figure 88 .............................................71 Changes to Figure 89 ......................................................................72 Changes to Table 30 ........................................................................77 11/10--Rev. B to Rev. C Change to Signal-to-Noise-and-Distortion Ratio, SINAD Parameter, Table 1 .............................................................................9 Changes to Figure 18 ......................................................................18 Changes to Figure 22 ......................................................................19 Changes to Silicon Anomaly Section............................................72 Added Table 28 to Silicon Anomaly Section, Renumbered Tables Sequentially ..........................................................................73 8/10--Rev. A to Rev. B Changes to Figure 1 ..........................................................................4 Changes to Figure 2 ..........................................................................5 Changes to Figure 3 ..........................................................................6 Changes to Figure 4 ..........................................................................7 Change to Table 8............................................................................16 Changes to Power-Up Procedure Section....................................23 Changes to Equation 6 and Equation 7........................................33 Changes to Equation 17 .................................................................43 Changes to Active Power Offset Calibration Section.................45 Changes to Figure 63 ......................................................................46 Changes to Reactive Power Offset Calibration Section .............49 Changes to Figure 82 ......................................................................65 Added Silicon Anomaly Section, Renumbered Tables Sequentially......................................................................................71 3/10--Rev. 0 to Rev. A Added ADE7854, ADE7858, and ADE7878 .................. Universal Reorganized Layout ........................................................... Universal Added Table 1, Renumbered Sequentially.....................................1 Added Figure 1, Renumbered Sequentially ...................................3 Added Figure 2 ..................................................................................4 Added Figure 3 ..................................................................................5 Changes to Specifications Section ..................................................7 Changes to Figure 9 ........................................................................14 Changes to Table 8 ..........................................................................14 Changes to Typical Performance Characteristics Section .........16 Changes to Figure 22 ......................................................................18 Changes to the Power Management Section ...............................20 Changes to the Theory of Operation Section..............................25 Changes to Figure 31 and Figure 32 .............................................27 Change to Equation 28 ...................................................................47 Changes to Figure 83 ......................................................................66 Changes to Figure 86 ......................................................................68 Changes to the Registers List Section...........................................72 Changes to Ordering Guide...........................................................91 2/10--Revision 0: Initial Version Rev. E | Page 3 of 96 Figure 1. ADE7854 Functional Block Diagram Rev. E | Page 4 of 96 VN 18 VCP 19 ICN 14 ICP 13 VBP 22 IBN 12 IBP 9 VAP 23 IAN 8 IAP 7 CLKOUT 28 CLKIN 27 PGA1 PGA1 PGA1 PGA3 PGA3 PGA3 ADC ADC ADC ADC ADC ADC 17 1.2V REF REFIN/OUT 4 LDO HPF HPFDIS [23:0] HPF HPFDIS [23:0] LDO 5 6 DGND DIGITAL INTEGRATOR DVDD TOTAL ACTIVE/APPARENT ENERGIES AND VOLTAGE/ CURRENT RMS CALCULATION FOR PHASE C (SEE PHASE A FOR DETAILED DATA PATH) TOTAL ACTIVE/APPARENT ENERGIES AND VOLTAGE/ CURRENT RMS CALCULATION FOR PHASE B (SEE PHASE A FOR DETAILED DATA PATH) AVGAIN 24 AVDD AIGAIN 25 AGND APHCAL POR 26 VDD X2 X2 LPF LPF LPF AWGAIN AVRMSOS AIRMSOS AWATTOS PHASE A, PHASE B, AND PHASE C DATA DIGITAL SIGNAL PROCESSOR AVRMS AIRMS AVAGAIN : : CFxDEN HSDC I2C : CFxDEN SPI/I2C DFC DFC DFC CFxDEN ADE7854 39 SS/HSA 37 MISO/HSD 38 MOSI/SDA 36 SCLK/SCL 32 IRQ1 29 IRQ0 35 CF3/HSCLK 34 CF2 33 CF1 3 PM1 2 PM0 08510-204 RESET ADE7854/ADE7858/ADE7868/ADE7878 FUNCTIONAL BLOCK DIAGRAMS Rev. E | Page 5 of 96 Figure 2. ADE7858 Functional Block Diagram VN 18 VCP 19 ICN 14 ICP 13 VBP 22 IBN 12 IBP 9 VAP 23 IAN 8 IAP 7 CLKOUT 28 CLKIN 27 PGA1 PGA1 PGA1 PGA3 PGA3 PGA3 ADC ADC ADC ADC ADC ADC 17 1.2V REF REFIN/OUT 4 LDO HPF HPFDIS [23:0] HPF HPFDIS [23:0] LDO 5 6 DGND DIGITAL INTEGRATOR DVDD TOTAL ACTIVE/REACTIVE/ APPARENT/ENERGIES AND VOLTAGE/CURRENT RMS CALCULATION FOR PHASE C (SEE PHASE A FOR DETAILED DATA PATH) TOTAL ACTIVE/REACTIVE/ APPARENT/ENERGIES AND VOLTAGE/CURRENT RMS CALCULATION FOR PHASE B (SEE PHASE A FOR DETAILED DATA PATH) AVGAIN 24 AVDD AIGAIN 25 AGND APHCAL POR 26 VDD LPF LPF LPF AWGAIN AWATTOS AVARGAIN AVRMSOS COMPUTATIONAL BLOCK FOR TOTAL REACTIVE POWER X2 X2 AIRMSOS PHASE A, PHASE B, AND PHASE C DATA DIGITAL SIGNAL PROCESSOR AVAROS AVRMS AIRMS AVAGAIN : : CF3DEN HSDC I2C : CF2DEN SPI/I2C DFC DFC DFC CF1DEN ADE7858 39 SS/HSA 37 MISO/HSD 38 MOSI/SDA 36 SCLK/SCL 32 IRQ1 29 IRQ0 35 CF3/HSCLK 34 CF2 33 CF1 3 PM1 2 PM0 08510-203 RESET ADE7854/ADE7858/ADE7868/ADE7878 Figure 3. ADE7868 Functional Block Diagram Rev. E | Page 6 of 96 INN 16 INP 15 VN 18 VCP 19 ICN 14 ICP 13 VBP 22 IBN 12 IBP 9 VAP 23 IAN 8 IAP 7 CLKOUT 28 CLKIN 27 PGA2 PGA1 PGA1 PGA1 PGA3 PGA3 PGA3 ADC ADC ADC ADC ADC ADC ADC 17 1.2V REF REFIN/OUT 4 LDO HPF HPFDIS [23:0] HPF HPFDIS [23:0] LDO 5 6 DGND DIGITAL INTEGRATOR DVDD NIGAIN HPF HPFDIS [23:0] DIGITAL INTEGRATOR TOTAL ACTIVE/REACTIVE/ APPARENT/ENERGIES AND VOLTAGE/CURRENT RMS CALCULATION FOR PHASE C (SEE PHASE A FOR DETAILED DATA PATH) TOTAL ACTIVE/REACTIVE/ APPARENT/ENERGIES AND VOLTAGE/CURRENT RMS CALCULATION FOR PHASE B (SEE PHASE A FOR DETAILED DATA PATH) AVGAIN 24 AVDD AIGAIN 25 AGND APHCAL POR 26 VDD X2 LPF LPF LPF AWGAIN LPF NIRMSOS AWATTOS AVARGAIN AVRMSOS COMPUTATIONAL BLOCK FOR TOTAL REACTIVE POWER X2 X2 AIRMSOS NIRMS PHASE A, PHASE B, AND PHASE C DATA DIGITAL SIGNAL PROCESSOR AVAROS AVRMS AIRMS AVAGAIN : : CF3DEN HSDC I2C : CF2DEN SPI/I2C DFC DFC DFC CF1DEN ADE7868 39 SS/HSA 37 MISO/HSD 38 MOSI/SDA 36 SCLK/SCL 32 IRQ1 29 IRQ0 35 CF3/HSCLK 34 CF2 33 CF1 3 PM1 2 PM0 08 51 0-20 2 RESET ADE7854/ADE7858/ADE7868/ADE7878 Figure 4. ADE7878 Functional Block Diagram Rev. E | Page 7 of 96 INN 16 INP 15 VN 18 VCP 19 ICN 14 ICP 13 VBP 22 IBN 12 IBP 9 VAP 23 IAN 8 IAP 7 CLKOUT 28 CLKIN 27 PGA2 PGA1 PGA1 PGA1 PGA3 PGA3 PGA3 ADC ADC ADC ADC ADC ADC ADC 17 1.2V REF REFIN/OUT 4 LDO HPF HPFDIS [23:0] HPF HPFDIS [23:0] LDO 5 6 DGND DIGITAL INTEGRATOR DVDD NIGAIN HPF HPFDIS [23:0] DIGITAL INTEGRATOR TOTAL/FUNDAMENTAL ACTIVE/ REACTIVE ENERGIES, APPARENT ENERGY AND VOLTAGE/CURRENT RMS CALCULATION FOR PHASE C (SEE PHASE A FOR DETAILED DATA PATH) TOTAL/FUNDAMENTAL ACTIVE/ REACTIVE ENERGIES, APPARENT ENERGY AND VOLTAGE/CURRENT RMS CALCULATION FOR PHASE B (SEE PHASE A FOR DETAILED DATA PATH) AVGAIN 24 AVDD AIGAIN 25 AGND APHCAL POR 26 VDD X2 LPF LPF LPF AWGAIN LPF AFWGAIN AFVARGAIN NIRMSOS COMPUTATIONAL BLOCK FOR FUNDAMENTAL ACTIVE AND REACTIVE POWER AWATTOS AVARGAIN AVRMSOS COMPUTATIONAL BLOCK FOR TOTAL REACTIVE POWER X2 X2 AIRMSOS PHASE A, PHASE B, AND PHASE C DATA NIRMS DIGITAL SIGNAL PROCESSOR AFVAROS AFWATTOS AVAROS AVRMS AIRMS AVAGAIN : : CF3DEN HSDC I2C : CF2DEN SPI/I2C DFC DFC DFC CF1DEN ADE7878 39 SS/HSA 37 MISO/HSD 38 MOSI/SDA 36 SCLK/SCL 32 IRQ1 29 IRQ0 35 CF3/HSCLK 34 CF2 33 CF1 3 PM1 2 PM0 0 8 5 1 0-2 01 RESET ADE7854/ADE7858/ADE7868/ADE7878 ADE7854/ADE7858/ADE7868/ADE7878 SPECIFICATIONS VDD = 3.3 V 10%, AGND = DGND = 0 V, on-chip reference, CLKIN = 16.384 MHz, TMIN to TMAX = -40C to +85C. Table 2. Parameter 1, 2 ACCURACY Active Energy Measurement Active Energy Measurement Error (per Phase) Total Active Power Fundamental Active Power (ADE7878 Only) Min Typ Unit Test Conditions/Comments 0.1 % 0.2 % 0.1 % 0.1 % 0.2 % 0.1 % Over a dynamic range of 1000 to 1, PGA = 1, 2, 4; integrator off Over a dynamic range of 3000 to 1, PGA = 1, 2, 4; integrator off Over a dynamic range of 500 to 1, PGA = 8, 16; integrator on Over a dynamic range of 1000 to 1, PGA = 1, 2, 4; integrator off Over a dynamic range of 3000 to 1, PGA = 1, 2, 4; integrator off Over a dynamic range of 500 to 1, PGA = 8, 16; integrator on Line frequency = 45 Hz to 65 Hz, HPF on Phase lead 37 Phase lag 60 VDD = 3.3 V + 120 mV rms/120 Hz, IPx = VPx = 100 mV rms Phase Error Between Channels Power Factor (PF) = 0.8 Capacitive PF = 0.5 Inductive AC Power Supply Rejection Output Frequency Variation DC Power Supply Rejection Output Frequency Variation Total Active Energy Measurement Bandwidth REACTIVE ENERGY MEASUREMENT (ADE7858, ADE7868, AND ADE7878) Reactive Energy Measurement Error (per Phase) Total Active Power Fundamental Active Power (ADE7878 Only) 0.05 0.05 Degrees Degrees 0.01 % 0.01 2 % kHz 0.1 % 0.2 % 0.1 % 0.1 % 0.2 % 0.1 % VDD = 3.3 V 330 mV dc Phase Error Between Channels PF = 0.8 Capacitive PF = 0.5 Inductive AC Power Supply Rejection Output Frequency Variation Max 0.05 0.05 0.01 Degrees Degrees % Rev. E | Page 8 of 96 Over a dynamic range of 1000 to 1, PGA = 1, 2, 4; integrator off Over a dynamic range of 3000 to 1, PGA = 1, 2, 4; integrator off Over a dynamic range of 500 to 1, PGA = 8, 16; integrator on Over a dynamic range of 1000 to 1, PGA = 1, 2, 4; integrator off Over a dynamic range of 3000 to 1, PGA = 1, 2, 4; integrator off Over a dynamic range of 500 to 1, PGA = 8, 16; integrator on Line frequency = 45 Hz to 65 Hz, HPF on Phase lead 37 Phase lag 60 VDD = 3.3 V + 120 mV rms/120 Hz, IPx = VPx = 100 mV rms ADE7854/ADE7858/ADE7868/ADE7878 Parameter 1, 2 DC Power Supply Rejection Output Frequency Variation Total Reactive Energy Measurement Bandwidth RMS MEASUREMENTS I rms and V rms Measurement Bandwidth I rms and V rms Measurement Error (PSM0 Mode) MEAN ABSOLUTE VALUE (MAV) MEASUREMENT (ADE7868 AND ADE7878) I mav Measurement Bandwidth (PSM1 Mode) I mav Measurement Error (PSM1 Mode) ANALOG INPUTS Maximum Signal Levels Input Impedance (DC) IAP, IAN, IBP, IBN, ICP, ICN, VAP, VBP, and VCP Pins VN Pin ADC Offset Error Min Max Test Conditions/Comments VDD = 3.3 V 330 mV dc % kHz 2 kHz 0.1 % 260 Hz 0.5 % Over a dynamic range of 100 to 1, PGA = 1, 2, 4, 8 mV peak Differential inputs between the following pins: IAP and IAN, IBP and IBN, ICP and ICN; singleended inputs between the following pins: VAP and VN, VBP and VN, VCP and VN 400 Over a dynamic range of 1000 to 1, PGA = 1 k 130 Active Low Pulse Width Jitter Unit 0.01 2 500 Gain Error WAVEFORM SAMPLING Current and Voltage Channels Signal-to-Noise Ratio, SNR Signal-to-Noise-and-Distortion Ratio, SINAD Bandwidth (-3 dB) TIME INTERVAL BETWEEN PHASES Measurement Error CF1, CF2, CF3 PULSE OUTPUTS Maximum Output Frequency Duty Cycle REFERENCE INPUT REFIN/OUT Input Voltage Range Input Capacitance ON-CHIP REFERENCE PSM0 and PSM1 Modes Reference Error Output Impedance Temperature Coefficient Typ 2 k mV 4 % 70 60 dB dB 2 kHz 0.3 Degrees Line frequency = 45 Hz to 65 Hz, HPF on 8 50 kHz % (1 + 1/CFDEN) x 50% 80 0.04 ms % WTHR = VARTHR = VATHR = PMAX = 33,516,139 If CF1, CF2, or CF3 frequency > 6.25 Hz and CFDEN is even and > 1 If CF1, CF2, or CF3 frequency > 6.25 Hz and CFDEN is odd and > 1 If CF1, CF2, or CF3 frequency < 6.25 Hz For CF1, CF2, or CF3 frequency = 1 Hz and nominal phase currents are larger than 10% of full scale 1.1 1.3 10 V pF PGA = 1, uncalibrated error, see the Terminology section External 1.2 V reference Sampling CLKIN/2048, 16.384 MHz/2048 = 8 kSPS See the Waveform Sampling Mode section PGA = 1 PGA = 1 Minimum = 1.2 V - 8%; maximum = 1.2 V + 8% Nominal 1.207 V at the REFIN/OUT pin at TA = 25C 2 1.2 10 50 Rev. E | Page 9 of 96 mV k ppm/C Maximum value across full temperature range of -40C to +85C ADE7854/ADE7858/ADE7868/ADE7878 Parameter 1, 2 CLKIN Input Clock Frequency Crystal Equivalent Series Resistance CLKIN Input Capacitance CLKOUT Output Capacitance LOGIC INPUTS--MOSI/SDA, SCLK/SCL, SS, RESET, PM0, AND PM1 Input High Voltage, VINH Input Low Voltage, VINL Input Current, IIN Input Capacitance, CIN LOGIC OUTPUTS--IRQ0, IRQ1, MISO/HSD Output High Voltage, VOH ISOURCE Output Low Voltage, VOL ISINK CF1, CF2, CF3/HSCLK Output High Voltage, VOH ISOURCE Output Low Voltage, VOL ISINK POWER SUPPLY PSM0 Mode VDD Pin IDD PSM1 and PSM2 Modes (ADE7868 and ADE7878) VDD Pin IDD PSM1 Mode PSM2 Mode PSM3 Mode VDD Pin IDD in PSM3 Mode 1 2 Min Typ Max Unit 16.22 30 16.384 16.55 200 MHz pF pF 20 20 2.0 0.8 -8.7 3 100 10 2.4 V V A A nA pF 800 0.4 2 V A V mA 500 0.4 2 V A V mA 2.4 Test Conditions/Comments All specifications CLKIN of 16.384 MHz VDD = 3.3 V 10% VDD = 3.3 V 10% Input = 0 V, VDD = 3.3 V Input = VDD = 3.3 V Input = VDD = 3.3 V VDD = 3.3 V 10% VDD = 3.3 V 10% VDD = 3.3 V 10% VDD = 3.3 V 10% VDD = 3.3 V 10% For specified performance 3.0 24 2.4 3.6 26.8 V mA 3.7 V 6.0 0.2 Minimum = 3.3 V - 10%; maximum = 3.3 V + 10% mA mA For specified performance 2.4 3.7 1.7 See the Typical Performance Characteristics section. See the Terminology section for a definition of the parameters. Rev. E | Page 10 of 96 V A ADE7854/ADE7858/ADE7868/ADE7878 TIMING CHARACTERISTICS VDD = 3.3 V 10%, AGND = DGND = 0 V, on-chip reference, CLKIN = 16.384 MHz, TMIN to TMAX = -40C to +85C. Note that dual function pin names are referenced by the relevant function only within the timing tables and diagrams; see the Pin Configuration and Function Descriptions section for full pin mnemonics and descriptions. Table 3. I2C-Compatible Interface Timing Parameter Parameter SCL Clock Frequency Hold Time (Repeated) Start Condition Low Period of SCL Clock High Period of SCL Clock Set-Up Time for Repeated Start Condition Data Hold Time Data Setup Time Rise Time of Both SDA and SCL Signals Fall Time of Both SDA and SCL Signals Setup Time for Stop Condition Bus Free Time Between a Stop and Start Condition Pulse Width of Suppressed Spikes Standard Mode Min Max 0 100 4.0 4.7 4.0 4.7 0 3.45 250 1000 300 4.0 4.7 N/A 1 Fast Mode Min Max 0 400 0.6 1.3 0.6 0.6 0 0.9 100 20 300 20 300 0.6 1.3 50 Unit kHz s s s s s ns ns ns s s ns N/A means not applicable. SDA tSU;DAT tF tLOW tr tHD;STA tSP tr tBUF tf SCLK tHD;STA START CONDITION tHD;DAT tHIGH tSU;STA REPEATED START CONDITION Figure 5. I2C-Compatible Interface Timing Rev. E | Page 11 of 96 tSU;STO STOP START CONDITION CONDITION 08510-002 1 Symbol fSCL tHD;STA tLOW tHIGH tSU;STA tHD;DAT tSU;DAT tR tF tSU;STO tBUF tSP ADE7854/ADE7858/ADE7868/ADE7878 Table 4. SPI Interface Timing Parameters Parameter SS to SCLK Edge SCLK Period SCLK Low Pulse Width SCLK High Pulse Width Data Output Valid After SCLK Edge Data Input Setup Time Before SCLK Edge Data Input Hold Time After SCLK Edge Data Output Fall Time Data Output Rise Time SCLK Rise Time SCLK Fall Time MISO Disable After SS Rising Edge SS High After SCLK Edge Min 50 0.4 175 175 tSL tSH tDAV tDSU tDHD tDF tDR tSR tSF tDIS tSFS Max 4000 1 100 100 5 20 20 20 20 200 0 Guaranteed by design. SS tSS tSFS SCLK tSL tSH tDAV tSF tSR tDIS MSB MISO INTERMEDIATE BITS tDF LSB tDR INTERMEDIATE BITS LSB IN MSB IN MOSI tDSU 08510-003 1 Symbol tSS tDHD Figure 6. SPI Interface Timing Rev. E | Page 12 of 96 Unit ns s ns ns ns ns ns ns ns ns ns ns ns ADE7854/ADE7858/ADE7868/ADE7878 Table 5. HSDC Interface Timing Parameter Parameter HSA to HSCLK Edge HSCLK Period HSCLK Low Pulse Width HSCLK High Pulse Width Data Output Valid After HSCLK Edge Data Output Fall Time Data Output Rise Time HSCLK Rise Time HSCLK Fall Time HSD Disable After HSA Rising Edge HSA High After HSCLK Edge Symbol tSS Min 0 125 50 50 tSL tSH tDAV tDF tDR tSR tSF tDIS tSFS Max 40 20 20 10 10 5 0 HSA tSS tSFS HSCLK tSL tSF tSR tDIS MSB INTERMEDIATE BITS LSB tDF tDR Figure 7. HSDC Interface Timing 2mA TO OUTPUT PIN IOL 1.6V CL 50pF 800A IOH Figure 8. Load Circuit for Timing Specifications Rev. E | Page 13 of 96 08510-004 HSD tSH 08510-005 tDAV Unit ns ns ns ns ns ns ns ns ns ns ns ADE7854/ADE7858/ADE7868/ADE7878 ABSOLUTE MAXIMUM RATINGS TA = 25C, unless otherwise noted. THERMAL RESISTANCE Table 6. JA is specified equal to 29.3C/W; JC is specified equal to 1.8C/W. Parameter VDD to AGND VDD to DGND Analog Input Voltage to AGND, IAP, IAN, IBP, IBN, ICP, ICN, VAP, VBP, VCP, VN Analog Input Voltage to INP and INN Reference Input Voltage to AGND Digital Input Voltage to DGND Digital Output Voltage to DGND Operating Temperature Industrial Range Storage Temperature Range Junction Temperature Lead Temperature (Soldering, 10 sec) Rating -0.3 V to +3.7 V -0.3 V to +3.7 V -2 V to +2 V Table 7. Thermal Resistance Package Type 40-Lead LFCSP -2 V to +2 V -0.3 V to VDD + 0.3 V -0.3 V to VDD + 0.3 V -0.3 V to VDD + 0.3 V ESD CAUTION -40C to +85C -65C to +150C 150C 300C Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those listed in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Rev. E | Page 14 of 96 JA 29.3 JC 1.8 Unit C/W ADE7854/ADE7858/ADE7868/ADE7878 40 39 38 37 36 35 34 33 32 31 NC SS/HSA MOSI/SDA MISO/HSD SCLK/SCL CF3/HSCLK CF2 CF1 IRQ1 NC PIN CONFIGURATION AND FUNCTION DESCRIPTIONS ADE78xx TOP VIEW (Not to Scale) 30 29 28 27 26 25 24 23 22 21 NC IRQ0 CLKOUT CLKIN VDD AGND AVDD VAP VBP NC NOTES 1. NC = NO CONNECT. 2. CREATE A SIMILAR PAD ON THE PCB UNDER THE EXPOSED PAD. SOLDER THE EXPOSED PAD TO THE PAD ON THE PCB TO CONFER MECHANICAL STRENGTH TO THE PACKAGE. DO NOT CONNECT THE PADS TO AGND. 08510-106 NC IBN ICP ICN INP INN REFIN/OUT VN VCP NC 11 12 13 14 15 16 17 18 19 20 NC 1 PM0 2 PM1 3 RESET 4 DVDD 5 DGND 6 IAP 7 IAN 8 IBP 9 NC 10 Figure 9. Pin Configuration Table 8. Pin Function Descriptions Pin No. 1, 10, 11, 20, 21, 30, 31, 40 2 Mnemonic NC Description No Connect. These pins are not connected internally. PM0 3 PM1 4 RESET 5 DVDD 6 7, 8 DGND IAP, IAN 9, 12 IBP, IBN 13, 14 ICP, ICN 15, 16 INP, INN 17 REFIN/OUT Power Mode Pin 0. This pin, combined with PM1, defines the power mode of the ADE7854/ADE7858/ADE7868/ADE7878, as described in Table 9. Power Mode Pin 1. This pin defines the power mode of the ADE7854/ADE7858/ADE7868/ADE7878 when combined with PM0, as described in Table 9. Reset Input, Active Low. In PSM0 mode, this pin should stay low for at least 10 s to trigger a hardware reset. This pin provides access to the on-chip 2.5 V digital LDO. Do not connect any external active circuitry to this pin. Decouple this pin with a 4.7 F capacitor in parallel with a ceramic 220 nF capacitor. Ground Reference. This pin provides the ground reference for the digital circuitry. Analog Inputs for Current Channel A. This channel is used with the current transducers and is referenced in this document as Current Channel A. These inputs are fully differential voltage inputs with a maximum differential level of 0.5 V. This channel also has an internal PGA equal to the ones on Channel B and Channel C. Analog Inputs for Current Channel B. This channel is used with the current transducers and is referenced in this document as Current Channel B. These inputs are fully differential voltage inputs with a maximum differential level of 0.5 V. This channel also has an internal PGA equal to the ones on Channel C and Channel A. Analog Inputs for Current Channel C. This channel is used with the current transducers and is referenced in this document as Current Channel C. These inputs are fully differential voltage inputs with a maximum differential level of 0.5 V. This channel also has an internal PGA equal to the ones on Channel A and Channel B. Analog Inputs for Neutral Current Channel N. This channel is used with the current transducers and is referenced in this document as Current Channel N. These inputs are fully differential voltage inputs with a maximum differential level of 0.5 V. This channel also has an internal PGA, different from the ones found on the A, B, and C channels. The neutral current channel is available in the ADE7878 and ADE7868. In the ADE7858 and ADE7854, connect these pins to AGND. This pin provides access to the on-chip voltage reference. The on-chip reference has a nominal value of 1.2 V. An external reference source with 1.2 V 8% can also be connected at this pin. In either case, decouple this pin to AGND with a 4.7 F capacitor in parallel with a ceramic 100 nF capacitor. After reset, the on-chip reference is enabled. Rev. E | Page 15 of 96 ADE7854/ADE7858/ADE7868/ADE7878 Pin No. 18, 19, 22, 23 Mnemonic VN, VCP, VBP, VAP 24 AVDD 25 AGND 26 VDD 27 CLKIN 28 CLKOUT 29, 32 IRQ0, IRQ1 33, 34, 35 CF1, CF2, CF3/HSCLK 36 SCLK/SCL 37 38 39 EP MISO/HSD MOSI/SDA SS/HSA Exposed Pad Description Analog Inputs for the Voltage Channel. This channel is used with the voltage transducer and is referenced as the voltage channel in this document. These inputs are single-ended voltage inputs with a maximum signal level of 0.5 V with respect to VN for specified operation. This channel also has an internal PGA. This pin provides access to the on-chip 2.5 V analog low dropout regulator (LDO). Do not connect external active circuitry to this pin. Decouple this pin with a 4.7 F capacitor in parallel with a ceramic 220 nF capacitor. Ground Reference. This pin provides the ground reference for the analog circuitry. Tie this pin to the analog ground plane or to the quietest ground reference in the system. Use this quiet ground reference for all analog circuitry, for example, antialiasing filters, current, and voltage transducers. Supply Voltage. This pin provides the supply voltage. In PSM0 (normal power mode), maintain the supply voltage at 3.3 V 10% for specified operation. In PSM1 (reduced power mode), PSM2 (low power mode), and PSM3 (sleep mode), when the ADE7868/ADE7878 is supplied from a battery, maintain the supply voltage between 2.4 V and 3.7 V. Decouple this pin to AGND with a 10 F capacitor in parallel with a ceramic 100 nF capacitor. The only modes available on the ADE7858 and ADE7854 are the PSM0 and PSM3 power modes. Master Clock. An external clock can be provided at this logic input. Alternatively, a parallel resonant AT-cut crystal can be connected across CLKIN and CLKOUT to provide a clock source for the ADE7854/ADE7858/ADE7868/ADE7878. The clock frequency for specified operation is 16.384 MHz. Use ceramic load capacitors of a few tens of picofarad with the gate oscillator circuit. Refer to the crystal manufacturer's data sheet for load capacitance requirements. A crystal can be connected across this pin and CLKIN (as previously described with Pin 27 in this table) to provide a clock source for the ADE7854/ADE7858/ADE7868/ADE7878. The CLKOUT pin can drive one CMOS load when either an external clock is supplied at CLKIN or a crystal is being used. Interrupt Request Outputs. These are active low logic outputs. See the Interrupts section for a detailed presentation of the events that can trigger interrupts. Calibration Frequency (CF) Logic Outputs. These outputs provide power information based on the CF1SEL[2:0], CF2SEL[2:0], and CF3SEL[2:0] bits in the CFMODE register. These outputs are used for operational and calibration purposes. The full-scale output frequency can be scaled by writing to the CF1DEN, CF2DEN, and CF3DEN registers, respectively (see the Energy-to-Frequency Conversion section). CF3 is multiplexed with the serial clock output of the HSDC port. Serial Clock Input for SPI Port/Serial Clock Input for I2C Port. All serial data transfers are synchronized to this clock (see the Serial Interfaces section). This pin has a Schmidt trigger input for use with a clock source that has a slow edge transition time, for example, opto-isolator outputs. Data Out for SPI Port/Data Out for HSDC Port. Data In for SPI Port/Data Out for I2C Port. Slave Select for SPI Port/HSDC Port Active. Create a similar pad on the PCB under the exposed pad. Solder the exposed pad to the pad on the PCB to confer mechanical strength to the package. Do not connect the pads to AGND. Rev. E | Page 16 of 96 ADE7854/ADE7858/ADE7868/ADE7878 TYPICAL PERFORMANCE CHARACTERISTICS 0.10 0.50 0.05 0.40 0 0.30 0.20 -0.15 -0.20 0 -0.10 -0.25 -0.20 -0.30 -0.30 -0.35 -0.40 -0.40 0.01 0.1 1 10 100 PERCENTAGE OF FULL-SCALE CURRENT (%) Figure 10. Total Active Energy Error As Percentage of Reading (Gain = +1, Power Factor = 1) over Temperature with Internal Reference and Integrator Off 0.15 0.01 0.1 1 PERCENTAGE OF FULL-SCALE CURRENT (%) Figure 13. Total Active Energy Error As Percentage of Reading (Gain = +16, Power Factor = 1) over Temperature with Internal Reference and Integrator On 0.40 +85C, POWER FACTOR = 0 +25C, POWER FACTOR = 0 -40C, POWER FACTOR = 0 0.30 0.20 0.05 0.10 ERROR (%) 0 -0.05 -0.10 0 -0.10 -0.20 -0.15 -0.30 -0.20 47 49 51 53 55 57 59 61 63 65 LINE FREQUENCY (Hz) Figure 11. Total Active Energy Error As Percentage of Reading (Gain = +1) over Frequency with Internal Reference and Integrator Off 0.15 -0.50 0.01 1 10 100 Figure 14. Total Reactive Energy Error As Percentage of Reading (Gain = +1, Power Factor = 0) over Temperature with Internal Reference and Integrator Off 0.10 VDD = 2.97V VDD = 3.30V VDD = 3.63V 0.10 0.1 PERCENTAGE OF FULL-SCALE CURRENT (%) 08510-311 -0.40 08510-305 -0.25 45 +85C, POWER FACTOR = 1.0 +25C, POWER FACTOR = 1.0 -40C, POWER FACTOR = 1.0 -0.50 0.001 POWER FACTOR = 1 POWER FACTOR = +0.5 POWER FACTOR = -0.5 0.10 ERROR (%) 0.10 08510-308 -0.10 ERROR (%) +85C, POWER FACTOR = 1.0 +25C, POWER FACTOR = 1.0 -40C, POWER FACTOR = 1.0 08510-301 ERROR (%) -0.05 POWER FACTOR = 0 POWER FACTOR = +0.5 POWER FACTOR = -0.5 0.05 0 ERROR (%) 0 -0.05 -0.10 -0.15 -0.10 -0.20 0.1 1 10 PERCENTAGE OF FULL-SCALE CURRENT (%) 100 -0.25 45 08510-306 -0.15 0.01 -0.05 Figure 12. Total Active Energy Error As Percentage of Reading (Gain = +1, Power Factor = 1) over Power Supply with Internal Reference and Integrator Off 47 49 51 53 55 57 59 LINE FREQUENCY (Hz) 61 63 65 08510-315 ERROR (%) 0.05 Figure 15. Total Reactive Energy Error As Percentage of Reading (Gain = +1) over Frequency with Internal Reference and Integrator Off Rev. E | Page 17 of 96 ADE7854/ADE7858/ADE7868/ADE7878 0.30 0.70 VDD = 2.97V VDD = 3.30V VDD = 3.63V 0.20 0.60 0.50 0.40 ERROR (%) ERROR (%) 0.10 0 -0.10 0.30 0.20 0.10 0 -0.10 -0.20 0.1 1 10 100 PERCENTAGE OF FULL-SCALE CURRENT (%) -0.30 0.1 08510-316 -0.30 0.01 Figure 16. Total Reactive Energy Error As Percentage of Reading (Gain = +1, Power Factor = 0) over Power Supply with Internal Reference and Integrator Off 1 10 100 PERCENTAGE OF FULL-SCALE CURRENT (%) 08510-338 +85C, POWER FACTOR = 1.0 +25C, POWER FACTOR = 1.0 -40C, POWER FACTOR = 1.0 -0.20 Figure 19. Fundamental Active Energy Error As Percentage of Reading (Gain = +16) over Temperature with Internal Reference and Integrator On 0.15 0.60 0.50 POWER FACTOR = 1.0 POWER FACTOR = +0.5 POWER FACTOR = -0.5 0.10 0.40 0.05 0.20 ERROR (%) ERROR (%) 0.30 0.10 0 0 -0.05 -0.10 -0.10 -0.15 -0.20 +85C, POWER FACTOR = 0 +25C, POWER FACTOR = 0 -40C, POWER FACTOR = 0 10 100 PERCENTAGE OF FULL-SCALE CURRENT (%) Figure 17. Total Reactive Energy Error As Percentage of Reading (Gain = +16, Power Factor = 1) over Temperature with Internal Reference and Integrator On 0.20 ERROR (%) 0.20 0 -0.05 -0.15 -0.20 -0.20 -0.30 57 59 LINE FREQUENCY (Hz) 61 63 65 59 61 63 65 Figure 18. Fundamental Active Energy Error As Percentage of Reading (Gain = +1) over Frequency with Internal Reference and Integrator Off +85C, POWER FACTOR = 1.0 +25C, POWER FACTOR = 1.0 -40C, POWER FACTOR = 1.0 -0.40 08510-335 -0.25 55 57 0 -0.10 53 55 0.10 -0.10 51 53 0.40 0.30 49 51 0.50 0.05 47 49 Figure 20. Fundamental Reactive Energy Error As Percentage of Reading (Gain = +1) over Frequency with Internal Reference and Integrator Off 0.10 45 47 LINE FREQUENCY (Hz) POWER FACTOR = 1.0 POWER FACTOR = +0.5 POWER FACTOR = -0.5 0.15 ERROR (%) -0.25 45 08510-345 1 0.1 1 10 PERCENTAGE OF FULL-SCALE CURRENT (%) 100 08510-348 -0.40 0.1 -0.20 08510-318 -0.30 Figure 21. Fundamental Reactive Energy Error As Percentage of Reading (Gain = +16) over Temperature with Internal Reference and Integrator On Rev. E | Page 18 of 96 ADE7854/ADE7858/ADE7868/ADE7878 TEST CIRCUIT 3.3V 10k 1F 1k 5 18nF MISO/HSD 37 SAME AS IAP, IAN 18nF CF3/HSCLK 35 ADE78xx 14 ICN 6 25 4.7F + 0.1F 16.384MHz CLKIN 27 20pF 08510-099 23 VAP 20pF CLKOUT 28 AGND 22 VBP 1.5k IRQ0 29 REFIN/OUT 17 DGND SAME AS VCP SAME AS VCP SAME AS CF2 IRQ1 32 19 VCP 18nF 10k CF2 34 CF1 33 13 ICP 18 VN 1k 3.3V SCLK/SCL 36 9 IBP 12 IBN 0.22F MOSI/SDA 38 RESET 8 IAN SAME AS IAP, IAN + SS/HSA 39 7 IAP 18nF 1k 26 3 PM1 4 1k 24 DVDD 2 PM0 4.7F VDD 3.3V 0.22F AVDD 4.7F + Figure 22. Test Circuit Rev. E | Page 19 of 96 ADE7854/ADE7858/ADE7868/ADE7878 TERMINOLOGY Measurement Error The error associated with the energy measurement made by the ADE7854/ADE7858/ADE7868/ADE7878 is defined by Measurement Error = Energy Registered by ADE7878 - True Energy True Energy x 100% (1) Phase Error Between Channels The high-pass filter (HPF) and digital integrator introduce a slight phase mismatch between the current and the voltage channel. The all digital design ensures that the phase matching between the current channels and voltage channels in all three phases is within 0.1 over a range of 45 Hz to 65 Hz and 0.2 over a range of 40 Hz to 1 kHz. This internal phase mismatch can be combined with the external phase error (from current sensor or component tolerance) and calibrated with the phase calibration registers. Power Supply Rejection (PSR) This quantifies the ADE7878 measurement error as a percentage of reading when the power supplies are varied. For the ac PSR measurement, a reading at nominal supplies (3.3 V) is taken. A second reading is obtained with the same input signal levels when an ac signal (120 mV rms at 100 Hz) is introduced onto the supplies. Any error introduced by this ac signal is expressed as a percentage of reading--see the Measurement Error definition. ADC Offset Error This refers to the dc offset associated with the analog inputs to the ADCs. It means that with the analog inputs connected to AGND, the ADCs still see a dc analog input signal. The magnitude of the offset depends on the gain and input range selection (see the Typical Performance Characteristics section). However, the HPF removes the offset from the current and voltage channels and the power calculation remains unaffected by this offset. Gain Error The gain error in the ADCs of the ADE7858/ADE7868/ADE7878/ ADE7854 is defined as the difference between the measured ADC output code (minus the offset) and the ideal output code (see the Current Channel ADC section and the Voltage Channel ADC section). The difference is expressed as a percentage of the ideal code. CF Jitter The period of pulses at one of the CF1, CF2, or CF3 pins is continuously measured. The maximum, minimum, and average values of four consecutive pulses are computed as follows: Maximum = max(Period0, Period1, Period2, Period3) Minimum = min(Period0, Period1, Period2, Period3) Average = Period 0 + Period1 + Period 2 + Period 3 4 The CF jitter is then computed as For the dc PSR measurement, a reading at nominal supplies (3.3 V) is taken. A second reading is obtained with the same input signal levels when the power supplies are varied 10%. Any error introduced is expressed as a percentage of the reading. Rev. E | Page 20 of 96 CFJITTER = Maximum - Minimum x 100% Average (2) ADE7854/ADE7858/ADE7868/ADE7878 POWER MANAGEMENT The ADE7868/ADE7878 have four modes of operation, determined by the state of the PM0 and PM1 pins (see Table 9). The ADE7854/ADE7858 have two modes of operation. These pins provide complete control of the ADE7854/ADE7858/ADE7868/ ADE7878 operation and can easily be connected to an external microprocessor I/O. The PM0 and PM1 pins have internal pullup resistors. See Table 11 and Table 12 for a list of actions that are recommended before and after setting a new power mode. Table 9. Power Supply Modes Power Supply Modes PSM0, Normal Power Mode PSM1, Reduced Power Mode1 PSM2, Low Power Mode1 PSM3, Sleep Mode PM1 0 0 1 1 PM0 1 0 0 1 In summary, in this mode, it is not recommended to access any register other than AIMAV, BIMAV, and CIMAV. The circuit that measures these estimates of rms values is also active during PSM0; therefore, its calibration can be completed in either PSM0 mode or in PSM1 mode. Note that the ADE7868 and ADE7878 do not provide any register to store or process the corrections resulting from the calibration process. The external microprocessor stores the gain values in connection with these measurements and uses them during PSM1 (see the Current Mean Absolute Value Calculation--ADE7868 and ADE7878 Only section for more details on the xIMAV registers). PSM0--NORMAL POWER MODE (ALL PARTS) The 20-bit mean absolute value measurements done in PSM1, although available also in PSM0, are different from the rms measurements of phase currents and voltages executed only in PSM0 and stored in the xIRMS and xVRMS 24-bit registers. See the Current Mean Absolute Value Calculation--ADE7868 and ADE7878 Only section for details. In PSM0 mode, the ADE7854/ADE7858/ADE7868/ADE7878 are fully functional. The PM0 pin is set to high and the PM1 pin is set to low for the ADE78xx to enter this mode. If the ADE78xx is in one of PSM1, PSM2, or PSM3 modes and is switched into PSM0 mode, then all control registers take the default values with the exception of the threshold register, LPOILVL, which is used in PSM2 mode, and the CONFIG2 register, both of which maintain their values. If the ADE7868/ADE7878 is set in PSM1 mode while still in the PSM0 mode, the ADE7868/ADE7878 immediately begin the mean absolute value calculations without any delay. The xIMAV registers are accessible at any time; however, if the ADE7878 or ADE7868 is set in PSM1 mode while still in PSM2 or PSM3 modes, the ADE7868/ADE7878 signal the start of the mean absolute value computations by triggering the IRQ1 pin low. The xIMAV registers can be accessed only after this moment. The ADE7854/ADE7858/ADE7868/ADE7878 signal the end of the transition period by triggering the IRQ1 interrupt pin low and setting Bit 15 (RSTDONE) in the STATUS1 register to 1. This bit is 0 during the transition period and becomes 1 when the transition is finished. The status bit is cleared and the IRQ1 pin is set back to high by writing to the STATUS1 register with the corresponding bit set to 1. Bit 15 (RSTDONE) in the interrupt mask register does not have any functionality attached even if the IRQ1 pin goes low when Bit 15 (RSTDONE) in the STATUS1 register is set to 1. This makes the RSTDONE interrupt unmaskable. PSM2--LOW POWER MODE (ADE7868, ADE7878 ONLY) 1 Available in the ADE7868 and ADE7878. PSM1--REDUCED POWER MODE (ADE7868, ADE7878 ONLY) The reduced power mode, PSM1, is available on the ADE7868 and ADE7878 only. In this mode, the ADE7868/ADE7878 measure the mean absolute values (mav) of the 3-phase currents and store the results in the AIMAV, BIMAV, and CIMAV 20-bit registers. This mode is useful in missing neutral cases in which the voltage supply of the ADE7868 or ADE7878 is provided by an external battery. The serial ports, I2C or SPI, are enabled in this mode; the active port can be used to read the AIMAV, BIMAV, and CIMAV registers. It is not recommended to read any of the other registers because their values are not guaranteed in this mode. Similarly, a write operation is not taken into account by the ADE7868/ADE7878 in this mode. The low power mode, PSM2, is available on the ADE7868 and ADE7878 only. In this mode, the ADE7868/ADE7878 compare all phase currents against a threshold for a period of 0.02 x (LPLINE[4:0] + 1) seconds, independent of the line frequency. LPLINE[4:0] are Bits[7:3] of the LPOILVL register (see Table 10). Table 10. LPOILVL Register Bit [2:0] Mnemonic LPOIL[2:0] Default 111 [7:3] LPLINE[4:0] 00000 Description Threshold is put at a value corresponding to full scale multiplied by LPOIL/8. The measurement period is (LPLINE[4:0] + 1)/50 sec. The threshold is derived from Bits[2:0] (LPOIL[2:0]) of the LPOILVL register as LPOIL[2:0]/8 of full scale. Every time one phase current becomes greater than the threshold, a counter is incremented. If every phase counter remains below LPLINE[4:0] + 1 at the end of the measurement period, then the IRQ0 pin is triggered low. If a single phase counter becomes greater or equal to LPLINE[4:0] + 1 at the end of the measurement period, the IRQ1 pin is triggered low. Figure 23 illustrates how the ADE7868/ADE7878 behave in PSM2 mode when Rev. E | Page 21 of 96 ADE7854/ADE7858/ADE7868/ADE7878 LPLINE[4:0] = 2 and LPOIL[2:0] = 3. The test period is three 50 Hz cycles (60 ms), and the Phase A current rises above the LPOIL[2:0] threshold three times. At the end of the test period, the IRQ1 pin is triggered low. LPLINE[4:0] = 2 LPOIL[2:0] THRESHOLD IA CURRENT PHASE COUNTER = 2 PHASE COUNTER = 3 08510-008 PHASE COUNTER = 1 IRQ1 this signifies all phase currents stayed below threshold and, therefore, there is no current flowing through the system. At this point, the external microprocessor sets the ADE7868/ ADE7878 into Sleep Mode PSM3. If the IRQ1 pin is triggered low at the end of the measurement period, this signifies that at least one current input is above the defined threshold and current is flowing through the system, although no voltage is present at the ADE7868/ADE7878 pins. This situation is often called missing neutral and is considered a tampering situation, at which point the external microprocessor sets the ADE7868/ ADE7878 into PSM1 mode, measures the mean absolute values of phase currents, and integrates the energy based on their values and the nominal voltage. It is recommended to use the ADE7868/ADE7878 in PSM2 mode when Bits[2:0] (PGA1[2:0]) of the gain register are equal to 1 or 2. These bits represent the gain in the current channel datapath. It is not recommended to use the ADE7868/ADE7878 in PSM2 mode when the PGA1[2:0] bits are equal to 4, 8, or 16. PSM3--SLEEP MODE (ALL PARTS) Figure 23. PSM2 Mode Triggering IRQ1 Pin for LPLINE[4:0] = 2 (50 Hz Systems) The I2C or SPI port is not functional during this mode. The PSM2 mode reduces the power consumption required to monitor the currents when there is no voltage input and the voltage supply of the ADE7868/ADE7878 is provided by an external battery. If the IRQ0 pin is triggered low at the end of a measurement period, The sleep mode is available on all parts (ADE7854, ADE7858, ADE7868, and ADE7878). In this mode, the ADE78xx has most of its internal circuits turned off and the current consumption is at its lowest level. The I2C, HSDC, and SPI ports are not functional during this mode, and the RESET, SCLK/SCL, MOSI/SDA, and SS/HSA pins should be set high. Table 11. Power Modes and Related Characteristics All Registers1 LPOILVL, CONFIG2 I2C/SPI Functionality Set to default Set to default I2C enabled State After Software Reset Set to default Unchanged PSM1--ADE7878, ADE7868 Only Not available Values set during PSM0 unchanged Active serial port is unchanged if lockin procedure has been previously executed Enabled All circuits are active and DSP is in idle mode. All circuits are active and DSP is in idle mode. PSM2--ADE7878, ADE7868 Only Not available Values set during PSM0 unchanged Disabled PSM3 Not available Values set during PSM0 unchanged Disabled Power Mode PSM0 State After Hardware Reset 1 Setting for all registers except the LPOILVL and CONFIG2 registers. Rev. E | Page 22 of 96 Current mean absolute values are computed and the results are stored in the AIMAV, BIMAV, and CIMAV registers. The I2C or SPI serial port is enabled with limited functionality. Compares phase currents against the threshold set in LPOILVL. Triggers IRQ0 or IRQ1 pins accordingly. The serial ports are not available. Internal circuits shut down and the serial ports are not available. ADE7854/ADE7858/ADE7868/ADE7878 Table 12. Recommended Actions When Changing Power Modes Initial Power Mode PSM0 PSM1-- ADE7878, ADE7868 Only Recommended Actions Before Setting Next Power Mode Stop DSP by setting the run register = 0x0000. Disable HSDC by clearing Bit 6 (HSDEN) to 0 in the CONFIG register. Mask interrupts by setting MASK0 = 0x0 and MASK1 = 0x0. Erase interrupt status flags in the STATUS0 and STATUS1 registers. No action necessary. PSM2-- ADE7878, ADE7868 Only No action necessary. PSM3 No action necessary. Next Power Mode PSM0 PSM1 Current mean absolute values (mav) computed immediately. xIMAV registers can be accessed immediately. Wait until the IRQ1 pin is triggered low. Poll the STATUS1 register until Bit 15 (RSTDONE) is set to 1. Wait until the IRQ1 pin is triggered low. Poll the STATUS1 register until Bit 15 (RSTDONE) is set to 1. Wait until the IRQ1 pin is triggered low. Poll the STATUS1 register until Bit 15 (RSTDONE) is set to 1. Wait until the IRQ1 pin triggered low. Current mean absolute values compute at this moment. xIMAV registers may be accessed from this moment. Wait until the IRQ1 pin is triggered low. Current mav circuit begins computations at this time. xIMAV registers can be accessed from this moment. Rev. E | Page 23 of 96 PSM2 Wait until the IRQ0 or IRQ1 pin is triggered accordingly. PSM3 No action necessary. Wait until the IRQ0 or IRQ1 pin is triggered accordingly. No action necessary. No action necessary. Wait until the IRQ0 or IRQ1 pin is triggered accordingly. ADE7854/ADE7858/ADE7868/ADE7878 POWER-UP PROCEDURE 3.3V - 10% 2.0V 10% ADE78xx PSM0 READY 0V ADE78xx POWERED UP POR TIMER TURNED ON 40ms MICROPROCESSOR MAKES THE ADE78xx MICROPROCESSOR RSTDONE CHOICE BETWEEN ENTER PSM3 INTERRUPT I2C AND SPI SETS ADE78xx TRIGGERED IN PSM0 08510-009 26ms Figure 24. Power-Up Procedure The ADE7854/ADE7858/ADE7868/ADE7878 contain an onchip power supply monitor that supervises the power supply (VDD). At power-up, until VDD reaches 2 V 10%, the chip is in an inactive state. As VDD crosses this threshold, the power supply monitor keeps the chip in this inactive state for an additional 26 ms, allowing VDD to achieve 3.3 V - 10%, the minimum recommended supply voltage. Because the PM0 and PM1 pins have internal pull-up resistors and the external microprocessor keeps them high, the ADE7854/ADE7858/ADE7868/ ADE7878 always power-up in sleep mode (PSM3). Then, an external circuit (that is, a microprocessor) sets the PM1 pin to a low level, allowing the ADE78xx to enter normal mode (PSM0). The passage from PSM3 mode, in which most of the internal circuitry is turned off, to PSM0 mode, in which all functionality is enabled, is accomplished in less than 40 ms (see Figure 24 for details). If PSM0 mode is the only desired power mode, the PM1 pin can be set low permanently by using a direct connection to ground. The PM0 pin can remain open because the internal pull-up resistor ensures that its state is high. When the ADE7854/ADE7858/ADE7868/ADE7878 enter PSM0 mode, the I2C port is the active serial port. If the SPI port is used, then the SS/HSA pin must be toggled three times, high to low. This action selects the SPI port for further use. If I2C is the active serial port, Bit 1 (I2C_LOCK) of the CONFIG2 register must be set to 1 to lock it in. From this moment, the ADE78xx ignores spurious toggling of the SS/HSA pin, and an eventual switch to use the SPI port is no longer possible. Likewise, if SPI is the active serial port, any write to the CONFIG2 register locks the port, at which time a switch to use the I2C port is no longer possible. Only a power-down or by setting the RESET pin low can the ADE7854/ADE7858/ADE7868/ADE7878 be reset to use the I2C port. Once locked, the serial port choice is maintained when the ADE78xx changes PSMx power modes. Immediately after entering PSM0, the ADE7854/ADE7858/ ADE7868/ADE7878 set all registers to their default values, including the CONFIG2 and LPOILVL registers. The ADE7854/ADE7858/ADE7868/ADE7878 signals the end of the transition period by triggering the IRQ1 interrupt pin low and setting Bit 15 (RSTDONE) in the STATUS1 register to 1. This bit is 0 during the transition period and becomes 1 when the transition ends. The status bit is cleared and the IRQ1 pin is returned high by writing the STATUS1 register with the corresponding bit set to 1. Because the RSTDONE is an unmaskable interrupt, Bit 15 (RSTDONE) in the STATUS1 register must be cancelled for the IRQ1 pin to return high. It is recommended to wait until the IRQ1 pin goes low before accessing the STATUS1 register to test the state of the RSTDONE bit. At this point, as a good programming practice, it is also recommended to cancel all other status flags in the STATUS1 and STATUS0 registers by writing the corresponding bits with 1. Initially, the DSP is in idle mode, which means it does not execute any instruction. This is the moment to initialize all ADE78xx registers. The last register in the queue must be written three times to ensure the register has been initialized. Then, enable the data memory RAM protection and write 0x0001 into the run register to start the DSP (see the Digital Signal Processor section for details on data memory RAM protection and the run register). If the supply voltage, VDD, drops lower than 2 V 10%, the ADE7854/ADE7858/ADE7868/ADE7878 enter an inactive state, which means that no measurements or computations are executed. Rev. E | Page 24 of 96 ADE7854/ADE7858/ADE7868/ADE7878 HARDWARE RESET SOFTWARE RESET FUNCTIONALITY The ADE7854/ADE7858/ADE7868/ADE7878 each has a RESET pin. If the ADE7854, ADE7858, ADE7868, or ADE7878 is in PSM0 mode and the RESET pin is set low, then the ADE78xx enters the hardware reset state. The ADE78xx must be in PSM0 mode for a hardware reset to be considered. Setting the RESET pin low while the ADE78xx is in PSM1, PSM2, and PSM3 modes does not have any effect. Bit 7 (SWRST) in the CONFIG register manages the software reset functionality in PSM0 mode. The default value of this bit is 0. If this bit is set to 1, then the ADE7854/ADE7858/ADE7868/ ADE7878 enter the software reset state. In this state, almost all internal registers are set to their default values. In addition, the choice of which serial port, I2C or SPI, is in use remains unchanged if the lock-in procedure has been executed previously (see the Serial Interfaces for details). The registers that maintain their values despite the SWRST bit being set to 1 are the CONFIG2 and LPOILVL registers. When the software reset ends, Bit 7 (SWRST) in the CONFIG register is cleared to 0, the IRQ1 interrupt pin is set low, and Bit 15 (RSTDONE) in the STATUS1 register is set to 1. This bit is 0 during the transition period and becomes 1 when the transition ends. The status bit is cleared and the IRQ1 pin is set back high by writing to the STATUS1 register with the corresponding bit set to 1. If the ADE7854, ADE7858, ADE7868, or ADE7878 is in PSM0 mode and the RESET pin is toggled from high to low and then back to high after at least 10 s, all the registers are set to their default values, including the CONFIG2 and LPOILVL registers. The ADE78xx signals the end of the transition period by triggering the IRQ1 interrupt pin low and setting Bit 15 (RSTDONE) in the STATUS1 register to 1. This bit is 0 during the transition period and becomes 1 when the transition ends. The status bit is cleared and the IRQ1 pin is returned high by writing to the STATUS1 register with the corresponding bit set to 1. After a hardware reset, the DSP is in idle mode, which means it does not execute any instruction. Because the I2C port is the default serial port of the ADE7854/ ADE7858/ADE7868/ADE7878, it becomes active after a reset state. If SPI is the port used by the external microprocessor, the procedure to enable it must be repeated immediately after the RESET pin is toggled back to high (see the Serial Interfaces section for details). After a software reset ends, the DSP is in idle mode, which means it does not execute any instruction. It is recommended to initialize all the ADE7854/ADE7858/ADE7868/ADE7878 registers and then enable the data memory RAM protection and write 0x0001 into the run register to start the DSP (see the Digital Signal Processor section for details on data memory RAM protection and the run register). Software reset functionality is not available in PSM1, PSM2, or PSM3 mode. At this point, it is recommended to initialize all of the ADE78xx registers, enable data memory RAM protection, and then write 0x0001 into the run register to start the DSP. See the Digital Signal Processor section for details on data memory RAM protection and the run register. Rev. E | Page 25 of 96 ADE7854/ADE7858/ADE7868/ADE7878 THEORY OF OPERATION GAIN SELECTION ANALOG INPUTS DIFFERENTIAL INPUT V1 + V2 = 500mV MAX PEAK COMMON MODE VCM = 25mV MAX +500mV V1 IAP, IBP, ICP, OR INP V2 IAN, IBN, ICN, OR INN VCM Figure 25. Maximum Input Level, Current Channels, Gain = 1 The voltage channel has three single-ended voltage inputs: VAP, VBP, and VCP. These single-ended voltage inputs have a maximum input voltage of 0.5 V with respect to VN. In addition, the maximum signal level on analog inputs for VxP and VN is 0.5 V with respect to AGND. The maximum common-mode signal allowed on the inputs is 25 mV. Figure 26 presents a schematic of the voltage channels inputs and their relation to the maximum common-mode voltage. DIFFERENTIAL INPUT V1 + V2 = 500mV MAX PEAK COMMON MODE VCM = 25mV MAX +500mV V1 VAP, VBP, OR VCP VCM VN 08510-012 VCM -500mV IxN, VN NOTES 1. x = A, B, C, N y = A, B, C. Figure 27. PGA in Current and Voltage Channels ANALOG-TO-DIGITAL CONVERSION The ADE7868/ADE7878 have seven sigma-delta (-) analogto-digital converters (ADCs), and the ADE7854/ADE7858 have six - ADCs. In PSM0 mode, all ADCs are active. In PSM1 mode, only the ADCs that measure the Phase A, Phase B, and Phase C currents are active. The ADCs that measure the neutral current and the A, B, and C phase voltages are turned off. In PSM2 and PSM3 modes, the ADCs are powered down to minimize power consumption. CLKIN/16 All inputs have a programmable gain amplifier (PGA) with a possible gain selection of 1, 2, 4, 8, or 16. The gain of IA, IB, and IC inputs is set in Bits[2:0] (PGA1[2:0]) of the gain register. For the ADE7868 and ADE7878 only, the gain of the IN input is set in Bits[5:3] (PGA2[2:0]) of the gain register; thus, a different gain from the IA, IB, or IC inputs is possible. See Table 44 for details on the gain register. V1 K x VIN For simplicity, the block diagram in Figure 28 shows a firstorder - ADC. The converter is composed of the - modulator and the digital low-pass filter. 08510-010 VCM -500mV VIN Figure 26. Maximum Input Level, Voltage Channels, Gain = 1 All inputs have a programmable gain with a possible gain selection of 1, 2, 4, 8, or 16. To set the gain, use Bits[8:6] (PGA3[2:0]) in the gain register (see Table 44). Figure 27 shows how the gain selection from the gain register works in both current and voltage channels. ANALOG LOW-PASS FILTER R INTEGRATOR + C + - VREF LATCHED COMPARATOR - DIGITAL LOW-PASS FILTER 24 .....10100101..... 1-BIT DAC 08510-013 V1 + V2 IxP, VyP 08510-011 The ADE7868/ADE7878 have seven analog inputs forming current and voltage channels. The ADE7854/ADE7858 have six analog inputs, not offering the neutral current. The current channels consist of four pairs of fully differential voltage inputs: IAP and IAN, IBP and IBN, ICP and ICN, and INP and INN. These voltage input pairs have a maximum differential signal of 0.5 V. In addition, the maximum signal level on analog inputs for the IxP/IxN pair is 0.5 V with respect to AGND. The maximum common-mode signal allowed on the inputs is 25 mV. Figure 25 presents a schematic of the input for the current channels and their relation to the maximum common-mode voltage. Figure 28. First-Order - ADC A - modulator converts the input signal into a continuous serial stream of 1s and 0s at a rate determined by the sampling clock. In the ADE7854/ADE7858/ADE7868/ADE7878, the sampling clock is equal to 1.024 MHz (CLKIN/16). The 1-bit DAC in the feedback loop is driven by the serial data stream. The DAC output is subtracted from the input signal. If the loop gain is high enough, the average value of the DAC output (and, therefore, the bit stream) can approach that of the input signal level. For any given input value in a single sampling interval, the data from the 1-bit ADC is virtually meaningless. Only when a large number of samples are averaged is a meaningful result obtained. This averaging is carried out in the second part of the ADC, the digital low-pass filter. By averaging a large number of bits from the modulator, the low-pass filter can produce 24-bit data-words that are proportional to the input signal level. The - converter uses two techniques to achieve high resolution from what is essentially a 1-bit conversion technique. The first is oversampling. Oversampling means that the signal is sampled at a rate (frequency) that is many times higher than the bandwidth of interest. For example, the sampling rate in the ADE7854/ADE7858/ADE7868/ADE7878 is 1.024 MHz, Rev. E | Page 26 of 96 ADE7854/ADE7858/ADE7868/ADE7878 and the bandwidth of interest is 40 Hz to 2 kHz. Oversampling has the effect of spreading the quantization noise (noise due to sampling) over a wider bandwidth. With the noise spread more thinly over a wider bandwidth, the quantization noise in the band of interest is lowered, as shown in Figure 29. However, oversampling alone is not efficient enough to improve the signal-to-noise ratio (SNR) in the band of interest. For example, an oversampling factor of 4 is required just to increase the SNR by a mere 6 dB (1 bit). To keep the oversampling ratio at a reasonable level, it is possible to shape the quantization noise so that the majority of the noise lies at the higher frequencies. In the - modulator, the noise is shaped by the integrator, which has a high-pass-type response for the quantization noise. This is the second technique used to achieve high resolution. The result is that most of the noise is at the higher frequencies where it can be removed by the digital low-pass filter. This noise shaping is shown in Figure 29. filer (LPF) must be introduced. For conventional current sensors, it is recommended to use one RC filter with a corner frequency of 5 kHz for the attenuation to be sufficiently high at the sampling frequency of 1.024 MHz. The 20 dB per decade attenuation of this filter is usually sufficient to eliminate the effects of aliasing for conventional current sensors. However, for a di/dt sensor such as a Rogowski coil, the sensor has a 20 dB per decade gain. This neutralizes the 20 dB per decade attenuation produced by the LPF. Therefore, when using a di/dt sensor, take care to offset the 20 dB per decade gain. One simple approach is to cascade one additional RC filter, thereby producing a -40 dB per decade attenuation. ALIASING EFFECTS SAMPLING FREQUENCY ANTIALIAS FILTER (RC) DIGITAL FILTER SHAPED NOISE SAMPLING FREQUENCY 0 2 4 512 FREQUENCY (kHz) IMAGE FREQUENCIES NOISE 1024 08510-015 SIGNAL Figure 30. Aliasing Effects 0 2 4 512 FREQUENCY (kHz) ADC Transfer Function 1024 All ADCs in the ADE7854/ADE7858/ADE7868/ADE7878 are designed to produce the same 24-bit signed output code for the same input signal level. With a full-scale input signal of 0.5 V and an internal reference of 1.2 V, the ADC output code is nominally 5,928,256 (0x5A7540). The code from the ADC can vary between 0x800000 (-8,388,608) and 0x7FFFFF (+8,388,607); this is equivalent to an input signal level of 0.707 V. However, for specified performance, do not exceed the nominal range of 0.5 V; ADC performance is guaranteed only for input signals lower than 0.5 V. HIGH RESOLUTION OUTPUT FROM DIGITAL LPF SIGNAL 0 2 4 512 FREQUENCY (kHz) 1024 08510-014 NOISE Figure 29. Noise Reduction Due to Oversampling and Noise Shaping in the Analog Modulator Antialiasing Filter CURRENT CHANNEL ADC Figure 28 also shows an analog low-pass filter (RC) on the input to the ADC. This filter is placed outside the ADE7854/ADE7858/ ADE7868/ADE7878, and its role is to prevent aliasing. Aliasing is an artifact of all sampled systems as shown in Figure 30. Aliasing means that frequency components in the input signal to the ADC, which are higher than half the sampling rate of the ADC, appear in the sampled signal at a frequency below half the sampling rate. Frequency components above half the sampling frequency (also known as the Nyquist frequency, that is, 512 kHz) are imaged or folded back down below 512 kHz. This happens with all ADCs regardless of the architecture. In the example shown, only frequencies near the sampling frequency, that is, 1.024 MHz, move into the band of interest for metering, that is, 40 Hz to 2 kHz. To attenuate the high frequency (near 1.024 MHz) noise and prevent the distortion of the band of interest, a low-pass Figure 31 shows the ADC and signal processing path for Input IA of the current channels (it is the same for IB and IC). The ADC outputs are signed twos complement 24-bit datawords and are available at a rate of 8 kSPS (thousand samples per second). With the specified full-scale analog input signal of 0.5 V, the ADC produces its maximum output code value. Figure 31 shows a full-scale voltage signal applied to the differential inputs (IAP and IAN). The ADC output swings between -5,928,256 (0xA58AC0) and +5,928,256 (0x5A7540). The input, IN, corresponds to the neutral current of a 3-phase system (available in the ADE7868 and ADE7878 only). If no neutral line is present, connect this input to AGND. The datapath of the neutral current is similar to the path of the phase currents as shown in Figure 32. Rev. E | Page 27 of 96 ADE7854/ADE7858/ADE7868/ADE7878 LPF1 0x5A7540 = +5,928,256 CURRENT PEAK, OVERCURRENT DETECT INTEN BIT CONFIG[0] DSP IAP VIN PGA1 BITS REFERENCE GAIN[2:0] x1, x2, x4, x8, x16 PGA1 AIGAIN[23:0] ADC HPFDIS [23:0] ZX SIGNAL DATA RANGE ZX DETECTION 0V CURRENT RMS (IRMS) CALCULATION IAWV WAVEFORM SAMPLE REGISTER DIGITAL INTEGRATOR 0xA58AC0 = -5,928,256 TOTAL/FUNDAMENTAL ACTIVE AND REACTIVE POWER CALCULATION HPF IAN VIN CURRENT CHANNE L DATA RANGE AFTER INTEGRATION CURRENT CHANNE L DATA RANGE +0.5V/GAIN 0x5A7540 = +5,928,256 0x5A7540 = +5,928,256 0V 0V 0V ANALOG INPUT RANGE 0xA58AC0 = -5,928,256 ANALOG OUTPUT RANGE 0xA58AC0 = -5,928,256 08510-019 -0.5V/GAIN Figure 31. Current Channel Signal Path INTEN BIT CONFIG[0] INP VIN PGA2 BITS REFERENCE GAIN[5:3] x1, x2, x4, x8, x16 PGA2 NIGAIN[23:0] ADC CURRENT RMS (IRMS) CALCULATION DIGITAL INTEGRATOR INWV WAVEFORM SAMPLE REGISTER HPF INN 08510-120 DSP Figure 32. Neutral Current Signal Path (ADE7868, ADE7878 Only) Current Waveform = Content of Current Gain Register ADC Output x 1 + 223 (3) Changing the content of the AIGAIN, BIGAIN, CIGAIN, or INGAIN registers affects all calculations based on its current; that is, it affects the corresponding phase active/reactive/ apparent energy and current rms calculation. In addition, waveform samples scale accordingly. Note that the serial ports of the ADE7854, ADE7858, ADE7868, and/or ADE7878 work on 32-, 16-, or 8-bit words, and the DSP works on 28 bits. The 24-bit AIGAIN, BIGAIN, CIGAIN, and NIGAIN registers are accessed as 32-bit registers with the four 31 28 27 24 23 0000 0 24-BIT NUMBER BITS[27:24] ARE EQUAL TO BIT 23 08510-016 There is a multiplier in the signal path of each phase and neutral current. The current waveform can be changed by 100% by writing a corresponding twos complement number to the 24-bit signed current waveform gain registers (AIGAIN, BIGAIN, CIGAIN, and NIGAIN). For example, if 0x400000 is written to those registers, the ADC output is scaled up by 50%. To scale the input by -50%, write 0xC00000 to the registers. Equation 3 describes mathematically the function of the current waveform gain registers. most significant bits (MSBs) padded with 0s and sign extended to 28 bits. See Figure 33 for details. BIT 23 IS A SIGN BIT Figure 33. 24-Bit xIGAIN Transmitted as 32-Bit Words Current Channel HPF The ADC outputs can contain a dc offset. This offset can create errors in power and rms calculations. High-pass filters (HPFs) are placed in the signal path of the phase and neutral currents and of the phase voltages. If enabled, the HPF eliminates any dc offset on the current channel. All filters are implemented in the DSP and, by default, they are all enabled: the 24-bit HPFDIS register is cleared to 0x00000000. All filters are disabled by setting HPFDIS to any nonzero value. As stated in the Current Waveform Gain Registers section, the serial ports of the ADE78xx work on 32-, 16-, or 8-bit words. The HPFDIS register is accessed as a 32-bit register with eight MSBs padded with 0s. See Figure 34 for details. 31 24 0000 0000 23 0 24-BIT NUMBER 08510-017 Current Waveform Gain Registers Figure 34. 24-Bit HPFDIS Register Transmitted as 32-Bit Word Rev. E | Page 28 of 96 ADE7854/ADE7858/ADE7868/ADE7878 Current Channel Sampling The waveform samples of the current channel are taken at the output of HPF and stored in the 24-bit signed registers, IAWV, IBWV, ICWV, and INWV (ADE7868 and ADE7878 only) at a rate of 8 kSPS. All power and rms calculations remain uninterrupted during this process. Bit 17 (DREADY) in the STATUS0 register is set when the IAWV, IBWV, ICWV, and INWV registers are available to be read using the I2C or SPI serial port. Setting Bit 17 (DREADY) in the MASK0 register enables an interrupt to be set when the DREADY flag is set. See the Digital Signal Processor section for more details on Bit DREADY. As stated in the Current Waveform Gain Registers section, the serial ports of the ADE78xx work on 32-, 16-, or 8-bit words. When the IAWV, IBWV, ICWV, and INWV 24-bit signed registers are read from the ADE78xx (INWV is available on ADE7868/ADE7878 only), they are transmitted sign extended to 32 bits. See Figure 35 for details. 24 23 22 0 BITS[31:24] ARE EQUAL TO BIT 23 BIT 23 IS A SIGN BIT 08510-018 24-BIT SIGNED NUMBER Due to the di/dt sensor, the current signal needs to be filtered before it can be used for power measurement. On each phase and neutral current datapath, there is a built-in digital integrator to recover the current signal from the di/dt sensor. The digital integrator is disabled by default when the ADE78xx is powered up and after a reset. Setting Bit 0 (INTEN) of the CONFIG register turns on the integrator. Figure 37 and Figure 38 show the magnitude and phase response of the digital integrator. Note that the integrator has a -20 dB/dec attenuation and approximately -90 phase shift. When combined with a di/dt sensor, the resulting magnitude and phase response should be a flat gain over the frequency band of interest. However, the di/dt sensor has a 20 dB/dec gain associated with it and generates significant high frequency noise. An antialiasing filter of at least the second order is needed to avoid noise aliasing back in the band of interest when the ADC is sampling (see the Antialiasing Filter section). Figure 35. 24-Bit IxWV Register Transmitted as 32-Bit Signed Word MAGNITUDE (dB) 50 The ADE7854/ADE7858/ADE7868/ADE7878 devices each contain a high speed data capture (HSDC) port that is specially designed to provide fast access to the waveform sample registers. See the HSDC Interface section for more details. di/dt CURRENT SENSOR AND DIGITAL INTEGRATOR MAGNETIC FIELD CREATED BY CURRENT (DIRECTLY PROPORTIONAL TO CURRENT) 0.1 1 10 FREQUENCY (Hz) 100 1000 0 -50 -100 0 500 1000 1500 2000 2500 FREQUENCY (Hz) 3000 3500 4000 Figure 37. Combined Gain and Phase Response of the Digital Integrator 08510-020 + EMF (ELECTROMOTIVE FORCE) - INDUCED BY CHANGES IN MAGNETIC FLUX DENSITY (di/dt) -50 0.01 PHASE (Degrees) The di/dt sensor detects changes in the magnetic field caused by the ac current. Figure 36 shows the principle of a di/dt current sensor. 0 08510-116 31 loop generate an electromotive force (EMF) between the two ends of the loop. The EMF is a voltage signal that is proportional to the di/dt of the current. The voltage output from the di/dt current sensor is determined by the mutual inductance between the current carrying conductor and the di/dt sensor. Figure 36. Principle of a di/dt Current Sensor The flux density of a magnetic field induced by a current is directly proportional to the magnitude of the current. The changes in the magnetic flux density passing through a conductor The DICOEFF 24-bit signed register is used in the digital integrator algorithm. At power-up or after a reset, its value is 0x000000. Before turning on the integrator, this register must be initialized with 0xFFF8000. DICOEFF is not used when the integrator is turned off and can remain at 0x000000 in that case. Rev. E | Page 29 of 96 ADE7854/ADE7858/ADE7868/ADE7878 Similar to the registers shown in Figure 33, the DICOEFF 24-bit signed register is accessed as a 32-bit register with four MSBs padded with 0s and sign extended to 28 bits, which practically means it is transmitted equal to 0xFFF8000. -20 -25 -30 30 35 40 45 50 55 FREQUENCY (Hz) 60 65 When the digital integrator is switched off, the ADE78xx can be used directly with a conventional current sensor, such as a current transformer (CT). 70 VOLTAGE CHANNEL ADC -89.97 Figure 39 shows the ADC and signal processing chain for Input VA in the voltage channel. The VB and VC channels have similar processing chains. The ADC outputs are signed twos complement 24-bit words and are available at a rate of 8 kSPS. With the specified full-scale analog input signal of 0.5 V, the ADC produces its maximum output code value. Figure 39 shows a full-scale voltage signal being applied to the differential inputs (VA and VN). The ADC output swings between -5,928,256 (0xA58AC0) and +5,928,256 (0x5A7540). -89.98 -89.99 30 35 40 45 50 55 60 65 70 FREQUENCY (Hz) 08510-101 PHASE (Degrees) -89.96 Figure 38. Combined Gain and Phase Response of the Digital Integrator (40 Hz to 70 Hz) As stated in the Current Waveform Gain Registers section, the serial ports of the ADE78xx work on 32-, 16-, or 8-bit words. VOLTAGE PEAK, OVERVOLTAGE, SAG DETECT CURRENT RMS (VRMS) CALCULATION DSP VAP VIN PGA3 BITS GAIN[8:6] x1, x2, x4, x8, x16 PGA3 REFERENCE AVGAIN[23:0] ADC HPFDIS [23:0] HPF VN VIN VOLTAGE CHANNEL DATA RANGE +0.5V/GAIN VAWV WAVEFORM SAMPLE REGISTER TOTAL/FUNDAMENTAL ACTIVE AND REACTIVE POWER CALCULATION ZX DETECTION LPF1 0x5A7540 = +5,928,256 ZX SIGNAL DATA RANGE 0V 0V -0.5V/GAIN ANALOG INPUT RANGE 0xA58AC0 = -5,928,256 0x5A7540 = +5,928,256 ANALOG OUTPUT RANGE 0V 0xA58AC0 = -5,928,256 Figure 39. Voltage Channel Datapath Rev. E | Page 30 of 96 08510-025 MAGNITUDE (dB) -15 ADE7854/ADE7858/ADE7868/ADE7878 Voltage Waveform Gain Registers CHANGING PHASE VOLTAGE DATAPATH There is a multiplier in the signal path of each phase voltage. The voltage waveform can be changed by 100% by writing a corresponding twos complement number to the 24-bit signed current waveform gain registers (AVGAIN, BVGAIN, and CVGAIN). For example, if 0x400000 is written to those registers, the ADC output is scaled up by 50%. To scale the input by -50%, write 0xC00000 to the registers. Equation 4 describes mathematically the function of the current waveform gain registers. The ADE7854/ADE7858/ADE7868/ADE7878 can direct one phase voltage input to the computational datapath of another phase. For example, Phase A voltage can be introduced in the Phase B computational datapath, which means all powers computed by the ADE78xx in Phase B are based on Phase A voltage and Phase B current. (4) Changing the content of the AVGAIN, BVGAIN, and CVGAIN registers affects all calculations based on its voltage; that is, it affects the corresponding phase active/reactive/apparent energy and voltage rms calculation. In addition, waveform samples are scaled accordingly. As stated in the Current Waveform Gain Registers section, the serial ports of the ADE78xx work on 32-, 16-, or 8-bit words, and the DSP works on 28 bits. As presented in Figure 33, the AVGAIN, BVGAIN, and CVGAIN registers are accessed as 32-bit registers with four MSBs padded with 0s and sign extended to 28 bits. Voltage Channel HPF As explained in the Current Channel HPF section, the ADC outputs can contain a dc offset that can create errors in power and rms calculations. HPFs are placed in the signal path of the phase voltages, similar to the ones in the current channels. The HPFDIS register can enable or disable the filters. See the Current Channel HPF section for more details. Bits[11:10] (VTOIB[1:0]) of the CONFIG register manage the Phase B voltage measured at the VB pin. If VTOIB[1:0] = 00 (default value), the voltage is directed to the Phase B computational datapath. If VTOIB[1:0] = 01, the voltage is directed to the Phase C path. If VTOIB[1:0] = 10, the voltage is directed to the Phase A path. If VTOIB[1:0] = 11, the ADE78xx behaves as if VTOIB[1:0] = 00. Bits[13:12] (VTOIC[1:0]) of the CONFIG register manage the Phase C voltage measured at the VC pin. If VTOIC[1:0] = 00 (default value), the voltage is directed to Phase C computational datapath, if VTOIC[1:0] = 01, the voltage is directed to the Phase A path. If VTOIC[1:0] = 10, the voltage is directed to the Phase B path. If VTOIC[1:0] = 11, the ADE78xx behaves as if VTOIC[1:0] = 00. IA APHCAL Voltage Channel Sampling VTOIA[1:0] = 01, PHASE A VOLTAGE DIRECTED TO PHASE B VA The waveform samples of the voltage channel are taken at the output of HPF and stored into VAWV, VBWV, and VCWV 24-bit signed registers at a rate of 8 kSPS. All power and rms calculations remain uninterrupted during this process. Bit 17 (DREADY) in the STATUS0 register is set when the VAWV, VBWV, and VCWV registers are available to be read using the I2C or SPI serial port. Setting Bit 17 (DREADY) in the MASK0 register enables an interrupt to be set when the DREADY flag is set. See the Digital Signal Processor section for more details on Bit DREADY. As stated in the Current Waveform Gain Registers section, the serial ports of the ADE78xx work on 32-, 16-, or 8-bit words. Similar to registers presented in Figure 35, the VAWV, VBWV, and VCWV 24-bit signed registers are transmitted sign extended to 32 bits. PHASE A COMPUTATIONAL DATAPATH IB BPHCAL PHASE B COMPUTATIONAL DATAPATH VTOIB[1:0] = 01, PHASE B VOLTAGE DIRECTED TO PHASE C VB IC CPHCAL VC PHASE C COMPUTATIONAL DATAPATH VTOIC[1:0] = 01, PHASE C VOLTAGE DIRECTED TO PHASE A 08510-026 Voltage Waveform = Content of Voltage Gain Register ADC Output x 1 + 2 23 Bits[9:8] (VTOIA[1:0]) of the CONFIG register manage the Phase A voltage measured at the VA pin. If VTOIA[1:0] = 00 (default value), the voltage is directed to the Phase A computational datapath. If VTOIA[1:0] = 01, the voltage is directed to the Phase B path. If VTOIA[1:0] = 10, the voltage is directed to the Phase C path. If VTOIA[1:0] = 11, the ADE7878 behaves as if VTOIA[1:0] = 00. Figure 40. Phase Voltages Used in Different Datapaths Figure 40 presents the case in which Phase A voltage is used in the Phase B datapath, Phase B voltage is used in the Phase C datapath, and Phase C voltage is used in the Phase A datapath. The ADE7854/ADE7858/ADE7868/ADE7878 each contain an HSDC port especially designed to provide fast access to the waveform sample registers. See the HSDC Interface section for more details. Rev. E | Page 31 of 96 ADE7854/ADE7858/ADE7868/ADE7878 POWER QUALITY MEASUREMENTS Zero-Crossing Detection The ADE7854/ADE7858/ADE7868/ADE7878 have a zerocrossing (ZX) detection circuit on the phase current and voltage channels. The neutral current datapath does not contain a zerocrossing detection circuit. Zero-crossing events are used as a time base for various power quality measurements and in the calibration process. The output of LPF1 is used to generate zero crossing events. The low-pass filter is intended to eliminate all harmonics of 50 Hz and 60 Hz systems, and to help identify the zero-crossing events on the fundamental components of both current and voltage channels. The digital filter has a pole at 80 Hz and is clocked at 256 kHz. As a result, there is a phase lag between the analog input signal (one of IA, IB, IC, VA, VB, and VC) and the output of LPF1. The error in ZX detection is 0.0703 for 50 Hz systems (0.0843 for 60 Hz systems). The phase lag response of LPF1 results in a time delay of approximately 31.4 or 1.74 ms (at 50 Hz) between its input and output. The overall delay between the zero crossing on the analog inputs and ZX detection obtained after LPF1 is about 39.6 or 2.2 ms (at 50 Hz). The ADC and HPF introduce the additional delay. The LPF1 cannot be disabled to assure a good resolution of the ZX detection. Figure 41 shows how the zero-crossing signal is detected. DSP PGA REFERENCE xIGAIN[23:0] OR xVGAIN[23:0] HPFDIS [23:0] HPF IA, IB, IC, OR VA, VB, VC If a ZXTOIx or ZXTOVx bit is set in the MASK1 register, the IRQ1 interrupt pin is driven low when the corresponding status bit is set to 1. The status bit is cleared and the IRQ1 pin is returned to high by writing to the STATUS1 register with the status bit set to 1. The resolution of the ZXOUT register is 62.5 s (16 kHz clock) per LSB. Thus, the maximum timeout period for an interrupt is 4.096 sec: 216/16 kHz. LPF1 39.6 OR 2.2ms @ 50Hz 1 0.855 0V Every zero-crossing detection circuit has an associated timeout register. This register is loaded with the value written into the 16-bit ZXTOUT register and is decremented (1 LSB) every 62.5 s (16 kHz clock). The register is reset to the ZXTOUT value every time a zero crossing is detected. The default value of this register is 0xFFFF. If the timeout register decrements to 0 before a zero crossing is detected, one of Bits[8:3] of the STATUS1 register is set to 1. Bit 3 (ZXTOVA), Bit 4 (ZXTOVB), and Bit 5 (ZXTOVC) in the STATUS1 register refer to Phase A, Phase B, and Phase C of the voltage channel; Bit 6 (ZXTOIA), Bit 7 (ZXTOIB), and Bit 8 (ZXTOIC) in the STATUS1 register refer to Phase A, Phase B, and Phase C of the current channel. Figure 42 shows the mechanism of the zero-crossing timeout detection when the voltage or the current signal stays at a fixed dc level for more than 62.5 s x ZXTOUT s. ZX DETECTION ADC Zero-Crossing Timeout 16-BIT INTERNAL REGISTER VALUE ZXTOUT ZX ZX ZX ZX 08510-027 IA, IB, IC, OR VA, VB, VC in the current channel drive Bit 12 (ZXIA), Bit 13 (ZXIB), and Bit 14 (ZXIC) in the STATUS1 register. If a ZX detection bit is set in the MASK1 register, the IRQ1 interrupt pin is driven low and the corresponding status flag is set to 1. The status bit is cleared and the IRQ1 pin is set to high by writing to the STATUS1 register with the status bit set to 1. LPF1 OUTPUT Figure 41. Zero-Crossing Detection on Voltage and Current Channels The ADE7854/ADE7858/ADE7868/ADE7878 contain six zerocrossing detection circuits, one for each phase voltage and current channel. Each circuit drives one flag in the STATUS1 register. If a circuit placed in the Phase A voltage channel detects one zero-crossing event, Bit 9 (ZXVA) in the STATUS1 register is set to 1. Similarly, the Phase B voltage circuit drives Bit 10 (ZXVB), the Phase C voltage circuit drives Bit 11 (ZXVC), and circuits placed VOLTAGE OR CURRENT SIGNAL 0V ZXZOxy FLAG IN STATUS1[31:0], x = V, A y = A, B, C IRQ1 INTERRUPT PIN 08510-028 To provide further protection from noise, input signals to the voltage channel with amplitude lower than 10% of full scale do not generate zero-crossing events at all. The Current Channel ZX detection circuit is active for all input signals independent of their amplitudes. Figure 42. Zero-Crossing Timeout Detection Phase Sequence Detection The ADE7854/ADE7858/ADE7868/ADE7878 have on-chip phase sequence error detection circuits. This detection works on phase voltages and considers only the zero crossings Rev. E | Page 32 of 96 ADE7854/ADE7858/ADE7868/ADE7878 If Bit 19 (SEQERR) in the MASK1 register is set to 1 and a phase sequence error event is triggered, the IRQ1 interrupt pin is driven low. The status bit is cleared and the IRQ1 pin is set high by writing to the STATUS1 register with the Status Bit 19 (SEQERR) set to 1. The phase sequence error detection circuit is functional only when the ADE78xx is connected in a 3-phase, 4-wire, three voltage sensors configuration (Bits[5:4], CONSEL[1:0] in the ACCMODE register, set to 00). In all other configurations, only two voltage sensors are used; therefore, it is not recommended to use the detection circuit. In these cases, use the time intervals between phase voltages to analyze the phase sequence (see the Time Interval Between Phases section for details). Figure 43 presents the case in which Phase A voltage is not followed by Phase B voltage but by Phase C voltage. Every time a negative-to-positive zero crossing occurs, Bit 19 (SEQERR) in the STATUS1 register is set to 1 because such zero crossings on Phase C, Phase B, or Phase A cannot come after zero crossings from Phase A, Phase C, or respectively, Phase B zero crossings. PHASE A PHASE C Time Interval Between Phases The ADE7854/ADE7858/ADE7868/ADE7878 have the capability to measure the time delay between phase voltages, between phase currents, or between voltages and currents of the same phase. The negative-to-positive transitions identified by the zerocrossing detection circuit are used as start and stop measuring points. Only one set of such measurements is available at one time, based on Bits[10:9] (ANGLESEL[1:0]) in the COMPMODE register. PHASE A ZX A PHASE B ZX B PHASE C ZX C 08510-030 determined by their negative-to-positive transitions. The regular succession of these zero-crossing events is Phase A followed by Phase B followed by Phase C (see Figure 44). If the sequence of zero-crossing events is, instead, Phase A followed by Phase C followed by Phase B, then Bit 19 (SEQERR) in the STATUS1 register is set. Figure 44. Regular Succession of Phase A, Phase B, and Phase C When the ANGLESEL[1:0] bits are set to 00, the default value, the delays between voltages and currents on the same phase are measured. The delay between Phase A voltage and Phase A current is stored in the 16-bit unsigned ANGLE0 register (see Figure 45 for details). In a similar way, the delays between voltages and currents on Phase B and Phase C are stored in the ANGLE1 and ANGLE2 registers, respectively. PHASE A VOLTAGE PHASE B PHASE A CURRENT ANGLE0 ZX A ZX C ZX B 08510-031 A, B, C PHASE VOLTAGES AFTER LPF1 Figure 45. Delay Between Phase A Voltage and Phase A Current Is Stored in the ANGLE0 Register BIT 19 (SEQERR) IN STATUS1 REGISTER STATUS1[19] SET TO 1 STATUS1[19] CANCELLED BY A WRITE TO THE STATUS1 REGISTER WITH SEQERR BIT SET 08510-029 IRQ1 Figure 43. SEQERR Bit Set to 1 When Phase A Voltage Is Followed by Phase C Voltage Once a phase sequence error has been detected, the time measurement between various phase voltages (see the Time Interval Between Phases section) can help to identify which phase voltage should be considered with another phase current in the computational datapath. Bits[9:8] (VTOIA[1:0]), Bits[11:10] (VTOIB[1:0]), and Bits[13:12] (VTOIC[1:0]) in the CONFIG register can be used to direct one phase voltage to the datapath of another phase. See the Changing Phase Voltage Datapath section for details. When the ANGLESEL[1:0] bits are set to 01, the delays between phase voltages are measured. The delay between Phase A voltage and Phase C voltage is stored into the ANGLE0 register. The delay between Phase B voltage and Phase C voltage is stored in the ANGLE1 register, and the delay between Phase A voltage and Phase B voltage is stored in the ANGLE2 register (see Figure 46 for details). When the ANGLESEL[1:0] bits are set to 10, the delays between phase currents are measured. Similar to delays between phase voltages, the delay between Phase A and Phase C currents is stored into the ANGLE0 register, the delay between Phase B and Phase C currents is stored in the ANGLE1 register, and the delay between Phase A and Phase B currents is stored into the ANGLE2 register (see Figure 46 for details). Rev. E | Page 33 of 96 ADE7854/ADE7858/ADE7868/ADE7878 PHASE A Phase Voltage Sag Detection PHASE C The ADE7854/ADE7858/ADE7868/ADE7878 can be programmed to detect when the absolute value of any phase voltage drops below a certain peak value for a number of half-line cycles. The phase where this event takes place is identified in Bits[14:12] (VSPHASE[x]) of the PHSTATUS register. This condition is illustrated in Figure 47. ANGLE1 08510-032 ANGLE2 PHASE B ANGLE0 PHASE B VOLTAGE FULL SCALE SAGLVL[23:0] Figure 46. Delays Between Phase Voltages (Currents) The ANGLE0, ANGLE1, and ANGLE2 registers are 16-bit unsigned registers with 1 LSB corresponding to 3.90625 s (256 kHz clock), which means a resolution of 0.0703 (360 x 50 Hz/256 kHz) for 50 Hz systems and 0.0843 (360 x 60 Hz/ 256 kHz) for 60 Hz systems. The delays between phase voltages or phase currents are used to characterize how balanced the load is. The delays between phase voltages and currents are used to compute the power factor on each phase as shown in the following Equation 5: 360 o x f LINE cosx = cos ANGLEx x 256 kHz SAGCYC[7:0] = 0x4 PHASE A VOLTAGE FULL SCALE SAGLVL[23:0] STATUS1[16] AND PHSTATUS[12] CANCELLED BY A WRITE TO STATUS1[31:0] WITH SAG BIT SET (5) SAGCYC[7:0] = 0x4 where fLINE = 50 Hz or 60 Hz. BIT 16 (SAG) IN STATUS1[31:0] The ADE7854/ADE7858/ADE7868/ADE7878 provide the period measurement of the line in the voltage channel. Bits[1:0] (PERSEL[1:0]) in the MMODE register select the phase voltage used for this measurement. The period register is a 16-bit unsigned register and updates every line period. Because of the LPF1 filter (see Figure 41), a settling time of 30 ms to 40 ms is associated with this filter before the measurement is stable. The period measurement has a resolution of 3.90625 s/LSB (256 kHz clock), which represents 0.0195% (50 Hz/256 kHz) when the line frequency is 50 Hz and 0.0234% (60 Hz/256 kHz) when the line frequency is 60 Hz. The value of the period register for 50 Hz networks is approximately 5120 (256 kHz/50 Hz) and for 60 Hz networks is approximately 4267 (256 kHz/60 Hz). The length of the register enables the measurement of line frequencies as low as 3.9 Hz (256 kHz/216). The period register is stable at 1 LSB when the line is established and the measurement does not change. The following expressions can be used to compute the line period and frequency using the period register: TL = PERIOD[15:0] + 1 [sec] 256E3 (6) fL = 256E3 [Hz] PERIOD[15:0] + 1 (7) IRQ1 PIN STATUS[16] AND PHSTATUS[13] SET TO 1 VSPHASE[0] = PHSTATUS[12] VSPHASE[1] = PHSTATUS[13] 08510-033 Period Measurement Figure 47. SAG Detection Figure 47 shows Phase A voltage falling below a threshold that is set in the SAG level register (SAGLVL) for four half-line cycles (SAGCYC = 4). When Bit 16 (SAG) in the STATUS1 register is set to 1 to indicate the condition, Bit VSPHASE[0] in the PHSTATUS register is also set to 1 because the event happened on Phase A Bit 16 (SAG) in the STATUS1 register. All Bits[14:12] (VSPHASE[2], VSPHASE[1], and VSPHASE[0]) of the PHSTATUS register (not just the VSPHASE[0] bit) are erased by writing the STATUS1 register with the SAG bit set to 1. The SAGCYC register represents the number of half-line cycles the phase voltage must remain below the level indicated in the SAGLVL register to trigger a SAG condition; 0 is not a valid number for SAGCYC. For example, when the SAG cycle (SAGCYC[7:0]) contains 0x07, the SAG flag in the STATUS1 register is set at the end of the seventh half line cycle for which the line voltage falls below the threshold. If Bit 16 (SAG) in Rev. E | Page 34 of 96 ADE7854/ADE7858/ADE7868/ADE7878 Note that the internal zero-crossing counter is always active. By setting the SAGLVL register, the first SAG detection result is, therefore, not executed across a full SAGCYC period. Writing to the SAGCYC register when the SAGLVL register is already initialized resets the zero-crossing counter, thus ensuring that the first SAG detection result is obtained across a full SAGCYC period. The recommended procedure to manage SAG events is the following: 1. 2. 3. 4. 5. Enable SAG interrupts in the MASK1 register by setting Bit 16 (SAG) to 1. When a SAG event happens, the IRQ1 interrupt pin goes low and Bit 16 (SAG) in the STATUS1 is set to 1. The STATUS1 register is read with Bit 16 (SAG) set to 1. The PHSTATUS register is read, identifying on which phase or phases a SAG event happened. The STATUS1 register is written with Bit 16 (SAG) set to 1. Immediately, the SAG bit and all Bits[14:12] (VSPHASE[2], VSPHASE[1], and VSPHASE[0]) of the PHSTATUS register are erased. The PEAKCYC register contains the number of half-line cycles used as a time base for the measurement. The circuit uses the zero-crossing points identified by the zero-crossing detection circuit. Bits[4:2] (PEAKSEL[2:0]) in the MMODE register select the phases upon which the peak measurement is performed. Bit 2 selects Phase A, Bit 3 selects Phase B, and Bit 4 selects Phase C. Selecting more than one phase to monitor the peak values decreases proportionally the measurement period indicated in the PEAKCYC register because zero crossings from more phases are involved in the process. When a new peak value is determined, one of Bits[26:24] (IPPHASE[2:0] or VPPHASE[2:0]) in the IPEAK and VPEAK registers is set to 1, identifying the phase that triggered the peak detection event. For example, if a peak value has been identified on Phase A current, Bit 24 (IPPHASE[0]) in the IPEAK register is set to 1. If next time a new peak value is measured on Phase B, Bit 24 (IPPHASE[0]) of the IPEAK register is cleared to 0, and Bit 25 (IPPHASE[1]) of the IPEAK register is set to 1. Figure 48 shows the composition of the IPEAK and VPEAK registers. IPPHASE/VPPHASE BITS 31 00000 27 26 25 24 23 0 24 BIT UNSIGNED NUMBER PEAK DETECTED ON PHASE A PEAK DETECTED ON PHASE C PEAK DETECTED ON PHASE B Figure 48. Composition of IPEAK[31:0] and VPEAK[31:0] Registers PEAK VALUE WRITTEN INTO IPEAK AT THE END OF FIRST PEAKCYC PERIOD END OF FIRST PEAKCYC = 16 PERIOD SAG Level Set The content of the SAGLVL[23:0] SAG level register is compared to the absolute value of the output from HPF. Writing 5,928,256 (0x5A7540) to the SAGLVL register, puts the SAG detection level at full scale (see the Voltage Channel ADC section), thus; the SAG event is triggered continuously. Writing 0x00 or 0x01 puts the SAG detection level at 0, therefore, the SAG event is never triggered. As stated in the Current Waveform Gain Registers section, the serial ports of the ADE78xx work on 32-, 16-, or 8-bit words. Similar to the register presented in Figure 34, the SAGLVL register is accessed as a 32-bit register with eight MSBs padded with 0s. END OF SECOND PEAKCYC = 16 PERIOD PHASE A CURRENT BIT 24 OF IPEAK CLEARED TO 0 AT THE END OF SECOND PEAKCYC PERIOD BIT 24 OF IPEAK PHASE B CURRENT Peak Detection The ADE7854/ADE7858/ADE7868/ADE7878 record the maximum absolute values reached by the voltage and current channels over a certain number of half-line cycles and stores BIT 25 OF IPEAK Rev. E | Page 35 of 96 PEAK VALUE WRITTEN INTO IPEAK AT THE END OF SECOND PEAKCYC PERIOD Figure 49. Peak Level Detection BIT 25 OF IPEAK SET TO 1 AT THE END OF SECOND PEAKCYC PERIOD 08510-035 When the Phase B voltage falls below the indicated threshold into the SAGLVL register for two line cycles, Bit VSPHASE[1] in the PHSTATUS register is set to 1, and Bit VSPHASE[0] is cleared to 0. Simultaneously, Bit 16 (SAG) in the STATUS1 register is set to 1 to indicate the condition. them into the less significant 24 bits of the VPEAK and IPEAK 32-bit registers. 08510-034 MASK1 is set, the IRQ1 interrupt pin is driven low in case of a SAG event in the same moment the Status Bit 16 (SAG) in STATUS1 register is set to 1. The SAG status bit in the STATUS1 register and all Bits[14:12] (VSPHASE[2], VSPHASE[1], and VSPHASE[0]]) of the PHSTATUS register are cleared, and the IRQ1 pin is returned to high by writing to the STATUS1 register with the status bit set to 1. ADE7854/ADE7858/ADE7868/ADE7878 PHASE A VOLTAGE CHANNEL Figure 49 shows how the ADE78xx records the peak value on the current channel when measurements on Phase A and Phase B are enabled (Bit PEAKSEL[2:0] in the MMODE register are 011). PEAKCYC is set to 16, meaning that the peak measurement cycle is four line periods. The maximum absolute value of Phase A is the greatest during the first four line periods (PEAKCYC = 16), so the maximum absolute value is written into the less significant 24 bits of the IPEAK register, and Bit 24 (IPPHASE[0]) of the IPEAK register is set to 1 at the end of the period. This bit remains at 1 for the duration of the second PEAKCYC period of four line cycles. The maximum absolute value of Phase B is the greatest during the second PEAKCYC period; therefore, the maximum absolute value is written into the less significant 24 bits of the IPEAK register, and Bit 25 (IPPHASE[1]) in the IPEAK register is set to 1 at the end of the period. Note that the internal zero-crossing counter is always active. By setting Bits[4:2] (PEAKSEL[2:0]) in the MMODE register, the first peak detection result is, therefore, not executed across a full PEAKCYC period. Writing to the PEAKCYC register when the PEAKSEL[2:0] bits are set resets the zero-crossing counter, thereby ensuring that the first peak detection result is obtained across a full PEAKCYC period. OVLVL[23:0] BIT 18 (OV) OF STATUS1 STATUS1[18] AND PHSTATUS[9] CANCELLED BY A WRITE OF STATUS1 WITH OV BIT SET. BIT 9 (OVPHASE) OF PHSTATUS Figure 50. Overvoltage Detection Whenever the absolute instantaneous value of the voltage goes above the threshold from the OVLVL register, Bit 18 (OV) in the STATUS1 register and Bit 9 (OVPHASE[0]) in the PHSTATUS register are set to 1. Bit 18 (OV) of the STATUS1 register and Bit 9 (OVPHASE[0]) in the PHSTATUS register are cancelled when the STATUS1 register is written with Bit 18 (OV) set to 1. The recommended procedure to manage overvoltage events is the following: 1. 2. 3. 4. 5. Overvoltage and Overcurrent Detection The ADE7854/ADE7858/ADE7868/ADE7878 detect when the instantaneous absolute value measured on the voltage and current channels becomes greater than the thresholds set in the OVLVL and OILVL 24-bit unsigned registers. If Bit 18 (OV) in the MASK1 register is set, the IRQ1 interrupt pin is driven low in case of an overvoltage event. There are two status flags set when the IRQ1 interrupt pin is driven low: Bit 18 (OV) in the STATUS1 register and one of Bits[11:9] (OVPHASE[2:0]) in the PHSTATUS register to identify the phase that generated the overvoltage. The Status Bit 18 (OV) in the STATUS1 register and all Bits[11:9] (OVPHASE[2:0]) in the PHSTATUS register are cleared, and the IRQ1 pin is set to high by writing to the STATUS1 register with the status bit set to 1. Figure 50 presents overvoltage detection in Phase A voltage. 08510-036 At the end of the peak detection period in the current channel, Bit 23 (PKI) in the STATUS1 register is set to 1. If Bit 23 (PKI) in the MASK1 register is set, the IRQ1 interrupt pin is driven low at the end of PEAKCYC period and Status Bit 23 (PKI) in the STATUS1 register is set to 1. In a similar way, at the end of the peak detection period in the voltage channel, Bit 24 (PKV) in the STATUS1 register is set to 1. If Bit 24 (PKV) in the MASK1 register is set, the IRQ1 interrupt pin is driven low at the end of PEAKCYC period and Status Bit 24 (PKV) in the STATUS1 register is set to 1. To find the phase that triggered the interrupt, one of either the IPEAK or VPEAK registers is read immediately after reading the STATUS1 register. Next, the status bits are cleared, and the IRQ1 pin is set to high by writing to the STATUS1 register with the status bit set to 1. OVERVOLTAGE DETECTED Enable OV interrupts in the MASK1 register by setting Bit 18 (OV) to 1. When an overvoltage event happens, the IRQ1 interrupt pin goes low. The STATUS1 register is read with Bit 18 (OV) set to 1. The PHSTATUS register is read, identifying on which phase or phases an overvoltage event happened. The STATUS1 register is written with Bit 18 (OV) set to 1. In this moment, Bit OV is erased and also all Bits[11:9] (OVPHASE[2:0]) of the PHSTATUS register. In case of an overcurrent event, if Bit 17 (OI) in the MASK1 register is set, the IRQ1 interrupt pin is driven low. Immediately, Bit 17 (OI) in the STATUS1 register and one of Bits[5:3] (OIPHASE[2:0]) in the PHSTATUS register, which identify the phase that generated the interrupt, are set. To find the phase that triggered the interrupt, the PHSTATUS register is read immediately after reading the STATUS1 register. Next, Status Bit 17 (OI) in the STATUS1 register and Bits[5:3] (OIPHASE[2:0]) in the PHSTATUS register are cleared and the IRQ1 pin is set to high by writing to the STATUS1 register with the status bit set to 1. The process is similar with overvoltage detection. Rev. E | Page 36 of 96 ADE7854/ADE7858/ADE7868/ADE7878 The content of the overvoltage (OVLVL), and overcurrent, (OILVL) 24-bit unsigned registers is compared to the absolute value of the voltage and current channels. The maximum value of these registers is the maximum value of the HPF outputs: +5,928,256 (0x5A7540). When the OVLVL or OILVL register is equal to this value, the overvoltage or overcurrent conditions are never detected. Writing 0x0 to these registers signifies the overvoltage or overcurrent conditions are continuously detected, and the corresponding interrupts are permanently triggered. As stated in the Current Waveform Gain Registers section, the serial ports of the ADE78xx work on 32-, 16-, or 8-bit words. Similar to the register presented in Figure 34, OILVL and OVLVL registers are accessed as 32-bit registers with the eight MSBs padded with 0s. Neutral Current Mismatch--ADE7868, ADE7878 Neutral current mismatch is available in the ADE7868 and ADE7878 only. In 3-phase systems, the neutral current is equal to the algebraic sum of the phase currents IN(t) = IA(t) + IB(t) + IC(t) If there is a mismatch between these two quantities, then a tamper situation may have occurred in the system. If ISUM - INWV ISUMLVL , then MISMTCH = 0 If ISUM - INWV > ISUMLVL , then MISMTCH = 1 ISUMLVL, the positive threshold used in the process, is a 24-bit signed register. Because it is used in a comparison with an absolute value, always set ISUMLVL as a positive number, somewhere between 0x00000 and 0x7FFFFF. ISUMLVL uses the same scale of the current ADCs outputs, so writing +5,928,256 (0x5A7540) to the ISUMLVL register puts the mismatch detection level at full scale; see the Current Channel ADC section for details. Writing 0x000000, the default value, or a negative value, signifies the MISMTCH event is always triggered. The right value for the application should be written into the ISUMLVL register after power-up or after a hardware/software reset to avoid continuously triggering MISMTCH events. As stated in the Current Waveform Gain Registers section, the serial ports of the ADE7868/ADE7878 work on 32-, 16-, or 8-bit words and the DSP works on 28 bits. As presented in Figure 51, ISUM, the 28-bit signed register, is accessed as a 32-bit register with the four most significant bits padded with 0s. 31 The ADE7868/ADE7878 compute the sum of the phase currents adding the content of the IAWV, IBWV, and ICWV registers, and storing the result into the ISUM 28-bit signed register: ISUM(t) = IA(t) + IB(t) + IC(t). ISUM is computed every 125 s (8 kHz frequency), the rate at which the current samples are available, and Bit 17 (DREADY) in the STATUS0 register is used to signal when the ISUM register can be read. See the Digital Signal Processor section for more details on Bit DREADY. To recover ISUM(t) value from the ISUM register, use the following expression: I SUM (t ) = The status bit is cleared and the IRQ1 pin is set back to high by writing to the STATUS1 register with Bit 20 (MISMTCH) set to 1. ISUM[27:0] x I FS ADC MAX where: ADCMAX = 5,928,256, the ADC output when the input is at full scale. IFS is the full-scale ADC phase current. The ADE7868/ADE7878 compute the difference between the absolute values of ISUM and the neutral current from the INWV register, take its absolute value and compare it against the ISUMLVL threshold. If ISUM - INWV ISUMLVL , then it is assumed that the neutral current is equal to the sum of the phase currents, and the system functions correctly. If ISUM - INWV > ISUMLVL , then a tamper situation may 28 27 0000 0 28-BIT SIGNED NUMBER 08510-250 Overvoltage and Overcurrent Level Set BIT 27 IS A SIGN BIT Figure 51. The ISUM[27:0] Register is Transmitted As a 32-Bit Word Similar to the registers presented in Figure 33, the ISUMLVL register is accessed as a 32-bit register with four most significant bits padded with 0s and sign extended to 28 bits. PHASE COMPENSATION As described in the Current Channel ADC and Voltage Channel ADC sections, the datapath for both current and voltages is the same. The phase error between current and voltage signals introduced by the ADE7854/ADE7858/ADE7868/ADE7878 is negligible. However, the ADE7854/ADE7858/ADE7868/ADE7878 must work with transducers that may have inherent phase errors. For example, a current transformer (CT) with a phase error of 0.1 to 3 is not uncommon. These phase errors can vary from part to part, and they must be corrected to perform accurate power calculations. The errors associated with phase mismatch are particularly noticeable at low power factors. The ADE78xx provides a means of digitally calibrating these small phase errors. The ADE78xx allows a small time delay or time advance to be introduced into the signal processing chain to compensate for the small phase errors. have occurred, and Bit 20 (MISMTCH) in the STATUS1 register is set to 1. An interrupt attached to the flag can be enabled by setting Bit 20 (MISMTCH) in the MASK1 register. If enabled, the IRQ1 pin is set low when Status Bit MISMTCH is set to 1. Rev. E | Page 37 of 96 ADE7854/ADE7858/ADE7868/ADE7878 APHCAL, BPHCAL, or CPHCAL = The phase calibration registers (APHCAL, BPHCAL, and CPHCAL) are 10-bit registers that can vary the time advance in the voltage channel signal path from -374.0 s to +61.5 s. Negative values written to the PHCAL registers represent a time advance whereas positive values represent a time delay. One LSB is equivalent to 0.976 s of time delay or time advance (clock rate of 1.024 MHz). With a line frequency of 60 Hz, this gives a phase resolution of 0.0211 (360 x 60 Hz/1.024 MHz) at the fundamental. This corresponds to a total correction range of -8.079 to +1.329 at 60 Hz. At 50 Hz, the correction range is -6.732 to +1.107 and the resolution is 0.0176 (360 x 50 Hz/ 1.024 MHz). (8) x ,x 0 phase _ resolution x + 512, x > 0 phase _ resolution Figure 53 illustrates how the phase compensation is used to remove x = -1 phase lead in IA of the current channel from the external current transducer (equivalent of 55.5 s for 50 Hz systems). To cancel the lead (1) in the current channel of Phase A, a phase lead must be introduced into the corresponding voltage channel. Using Equation 8, APHCAL is 57 least significant bits, rounded up from 56.8. The phase lead is achieved by introducing a time delay of 55.73 s into the Phase A current. Given a phase error of x degrees, measured using the phase voltage as the reference, the corresponding LSBs are computed dividing x by the phase resolution (0.0211/LSB for 60 Hz and 0.0176/LSB for 50 Hz). Results between -383 and +63 only are acceptable; numbers outside this range are not accepted. If the result is negative, the absolute value is written into the PHCAL registers. If the result is positive, 512 is added to the result before writing it into xPHCAL. 15 10 9 0000 00 0 xPHCAL 08510-038 As stated in the Current Waveform Gain Registers section, the serial ports of the ADE785xx work on 32-, 16-, or 8-bit words. As shown in Figure 52, APHCAL, BPHCAL, and CPHCAL 10-bit registers are accessed as 16-bit registers with the six MSBs padded with 0s. Figure 52. xPHCAL Registers Communicated As 16-Bit Registers IAP IA PGA1 ADC IAN PHASE CALIBRATION APHCAL = 57 VAP VA PGA3 ADC VN 1 IA IA PHASE COMPENSATION ACHIEVED DELAYING IA BY 56s VA 08510-039 VA 50Hz Figure 53. Phase Calibration on Voltage Channels Rev. E | Page 38 of 96 ADE7854/ADE7858/ADE7868/ADE7878 REFERENCE CIRCUIT The nominal reference voltage at the REFIN/OUT pin is 1.2 0.075% V. This is the reference voltage used for the ADCs in the ADE7854/ADE7858/ADE7868/ADE7878. The REFIN/OUT pin can be overdriven by an external source, for example, an external 1.2 V reference. The voltage of the ADE78xx reference drifts slightly with temperature; see the Specifications section for the temperature coefficient specification (in ppm/C). The value of the temperature drift varies from part to part. Because the reference is used for all ADCs, any x% drift in the reference results in a 2x% deviation of the meter accuracy. The reference drift resulting from temperature changes is usually very small and typically much smaller than the drift of other components on a meter. Alternatively, the meter can be calibrated at multiple temperatures. If Bit 0 (EXTREFEN) in the CONFIG2 register is cleared to 0 (the default value), the ADE7854/ADE7858/ADE7868/ADE7878 use the internal voltage reference. If the bit is set to 1, the external voltage reference is used. Set the CONFIG2 register during the PSM0 mode. Its value is maintained during the PSM1, PSM2, and PSM3 power modes. DIGITAL SIGNAL PROCESSOR The ADE7854/ADE7858/ADE7868/ADE7878 contain a fixed function digital signal processor (DSP) that computes all powers and rms values. It contains program memory ROM and data memory RAM. values. Next, write the last register in the queue two additional times to flush the pipeline, and then write the run register with 0x0001. In this way, the DSP starts the computations from a desired configuration. To protect the integrity of the data stored in the data memory RAM of the DSP (addresses between 0x4380 and 0x43BE), a write protection mechanism is available. By default, the protection is disabled and registers placed between 0x4380 and 0x43BE can be written without restriction. When the protection is enabled, no writes to these registers is allowed. Registers can be always read, without restriction, independent of the write protection state. To enable the protection, write 0xAD to an internal 8-bit register located at Address 0xE7FE, followed by a write of 0x80 to an internal 8-bit register located at Address 0xE7E3. It is recommended to enable the write protection before starting the DSP. If any data memory RAM based register needs to be changed, simply disable the protection, change the value and then re-enable the protection. There is no need to stop the DSP to change these registers. To disable the protection, write 0xAD to an internal 8-bit register located at Address 0xE7FE, followed by a write of 0x00 to an internal 8-bit register located at Address 0xE7E3. The recommended procedure to initialize the registers located in the data memory RAM is as follows: The program used for the power and rms computations is stored in the program memory ROM and the processor executes it every 8 kHz. The end of the computations is signaled by setting Bit 17 (DREADY) to 1 in the STATUS0 register. An interrupt attached to this flag can be enabled by setting Bit 17 (DREADY) in the MASK0 register. If enabled, the IRQ0 pin is set low and Status Bit DREADY is set to 1 at the end of the computations. The status bit is cleared and the IRQ0 pin is set to high by writing to the STATUS0 register with Bit 17 (DREADY) set to 1. * Initialize all registers. Write the last register in the queue three times to ensure its value was written into the RAM. Initialize all of the other registers of the ADE7854/ADE7858/ ADE7868/ADE7878 here as well. * Enable the write protection by writing 0xAD to an internal 8-bit register located at Address 0xE7FE, followed by a write of 0x80 to an internal 8-bit register located at Address 0xE7E3. * Read back all data memory RAM registers to ensure they were initialized with the desired values. The registers used by the DSP are located in the data memory RAM, at addresses between 0x4380 and 0x43BE. The width of this memory is 28 bits. Within the DSP core, the DSP contains a two stage pipeline. This means that when a single register needs to be initialized, two more writes are required to ensure the value has been written into RAM, and if two or more registers need to be initialized, the last register must be written two more times to ensure the value has been written into RAM. * In the remote case that one or more registers are not initialized correctly, disable the protection by writing 0xAD to an internal 8-bit register located at Address 0xE7FE, followed by a write of 0x00 to an internal 8-bit register located at Address 0xE7E3. Reinitialize the registers. Write the last register in the queue three times. Enable the write protection by writing 0xAD to an internal 8-bit register located at Address 0xE7FE, followed by a write of 0x80 to an internal 8-bit register located at Address 0xE7E3.. * Start the DSP by setting run = 1. As explained in the Power-Up Procedure section, at power-up or after a hardware or software reset, the DSP is in idle mode. No instruction is executed. All the registers located in the data memory RAM are initialized at 0, their default values, and they can be read/written without any restriction. The run register, used to start and stop the DSP, is cleared to 0x0000. The run register needs to be written with 0x0001 for the DSP to start code execution. It is recommended to first initialize all ADE78xx registers located in the data memory RAM with their desired There is no obvious reason to stop the DSP if the ADE78xx is maintained in PSM0 normal mode. All ADE78xx registers, including ones located in the data memory RAM, can be modified without stopping the DSP. However, to stop the DSP, 0x0000 has to be written into run register. To restart the DSP, one of the following procedures must be followed: Rev. E | Page 39 of 96 ADE7854/ADE7858/ADE7868/ADE7878 * * If the ADE7854/ADE7858/ADE7868/ADE7878 registers located in the data memory RAM have not been modified, write 0x0001 into the run register to start the DSP. If the ADE7854/ADE7858/ADE7868/ADE7878 registers located in the data memory RAM have to be modified, first execute a software or a hardware reset, initialize all ADE7854/ADE7858/ADE7868/ADE7878 registers at desired values, enable the write protection, and then write 0x0001 into the run register to start the DSP. As mentioned in the Power Management section, when the ADE7854/ADE7858/ADE7868/ADE7878 switch out of PSM0 power mode, it is recommended to stop the DSP by writing 0x0000 into the run register (see Table 11 and Table 12 for the recommended actions when changing power modes). The rms calculation based on this method is simultaneously processed on all seven analog input channels. Each result is available in the 24-bit registers: AIRMS, BIRMS, CIRMS, AVRMS, BVRMS, CVRMS, and NIRMS (NIRMS is available on the ADE7868 and ADE7878 only). The second method computes the absolute value of the input signal and then filters it to extract its dc component. It computes the absolute mean value of the input. If the input signal in Equation 12 has a fundamental component only, its average value is FDC FDC = ROOT MEAN SQUARE MEASUREMENT Root mean square (rms) is a measurement of the magnitude of an ac signal. Its definition can be both practical and mathematical. Defined practically, the rms value assigned to an ac signal is the amount of dc required to produce an equivalent amount of power in the load. Mathematically, the rms value of a continuous signal f(t) is defined as 1 t 2 f (t )dt t 0 F rms = (9) 1 N N f 2 [n] (10) N =1 Equation 10 implies that for signals containing harmonics, the rms calculation contains the contribution of all harmonics, not only the fundamental. The ADE78xx uses two different methods to calculate rms values. The first one is very accurate and is active only in PSM0 mode. The second one is less accurate, uses the estimation of the mean absolute value (mav) measurement, is active in PSM0 and PSM1 modes, and is available for the ADE7868 and ADE7878 only. The first method is to low-pass filter the square of the input signal (LPF) and take the square root of the result (see Figure 54). f (t ) = Fk 2 sin(kt + k ) (11) k =1 Then k =1 k =1 f 2 (t ) = Fk2 - Fk2 cos(2kt + k ) + +2 2 x Fk x Fm sin(kt + k )x sin(mt + m ) (12) k ,m=1 k m After the LPF and the execution of the square root, the rms value of f(t) is obtained by F= Fk2 2 x 2 x F1 The calculation based on this method is simultaneously processed only on the three phase currents. Each result is available in the 20-bit registers, which are available on the AE7868 and ADE7878 only: AIMAV, BMAV, and CMAV. Note that the proportionality between mav and rms values is maintained for the fundamental components only. If harmonics are present in the current channel, the mean absolute value is no longer proportional to rms. Current RMS Calculation For time sampling signals, rms calculation involves squaring the signal, taking the average, and obtaining the square root. F rms = T T 1 2 = 2 x F1 x sin(t )dt - 2 x F1 x sin(t )dt T 0 T 2 (13) This section presents the first approach to compute the rms values of all phase and neutral currents. Figure 54 shows the detail of the signal processing chain for the rms calculation on one of the phases of the current channel. The current channel rms value is processed from the samples used in the current channel. The current rms values are signed 24-bit values and they are stored into the AIRMS, BIRMS, CIRMS, and NIRMS (ADE7868/ADE7878 only) registers. The update rate of the current rms measurement is 8 kHz. With the specified full-scale analog input signal of 0.5 V, the ADC produces an output code that is approximately 5,928,256. The equivalent rms value of a full-scale sinusoidal signal is 4,191,910 (0x3FF6A6), independent of the line frequency. If the integrator is enabled, that is, when Bit 0 (INTEN) in the CONFIG register is set to 1, the equivalent rms value of a fullscale sinusoidal signal at 50 Hz is 4,191,910 (0x3FF6A6) and at 60 Hz is 3,493,258 (0x354D8A). The accuracy of the current rms is typically 0.1% error from the full-scale input down to 1/1000 of the full-scale input when PGA = 1. Additionally, this measurement has a bandwidth of 2 kHz. It is recommended to read the rms registers synchronous to the voltage zero crossings to ensure stability. The IRQ1 interrupt can be used to indicate when a zero crossing has occurred (see the Interrupts section). Table 13 shows the settling time for the I rms measurement, which is the time it takes for the rms register to reflect the value at the input to the current channel when starting from 0. k =1 Rev. E | Page 40 of 96 ADE7854/ADE7858/ADE7868/ADE7878 As stated in the Current Waveform Gain Registers section, the serial ports of the ADE78xx work on 32-, 16-, or 8-bit words. Similar to the register presented in Figure 34, the AIRMS, BIRMS, CIRMS, and NIRMS (ADE7868/ADE7878 only) 24-bit signed registers are accessed as 32-bit registers with the eight MSBs padded with 0s. Table 13. Settling Time for I rms Measurement 50 Hz Input signals 440 ms 550 ms 60 Hz Input signals 440 ms 500 ms xIRMSOS[23:0] 27 CURRENT SIGNAL FROM HPF OR INTEGRATOR (IF ENABLED) x2 LPF xIRMS[23:0] 0x5A7540 = 5,928,256 0V 0xA58AC0 = -5,928,256 Figure 54. Current RMS Signal Processing Rev. E | Page 41 of 96 08510-040 Integrator Status Integrator Off Integrator On ADE7854/ADE7858/ADE7868/ADE7878 212000 Current RMS Offset Compensation I rms = I rms02 + 128 x IRMSOS (14) where I rms0 is the rms measurement without offset correction. As stated in the Current Waveform Gain Registers section, the serial ports of the ADE78xx work on 32-, 16-, or 8-bit words and the DSP works on 28 bits. Similar to the register presented in Figure 33, the AIRMSOS, BIRMSOS, CIRMSOS, and NIRMSOS (ADE7868/ADE7878 only) 24-bit signed registers are accessed as 32-bit registers with four MSBs padded with 0s and sign extended to 28 bits. Current Mean Absolute Value Calculation--ADE7868 and ADE7878 Only CURRENT SIGNAL COMING FROM ADC xIMAV[23:0] |X| HPF HPF 08510-251 This section presents the second approach to estimate the rms values of all phase currents using the mean absolute value (mav) method. This approach is used in PSM1 mode, which is available to the ADE7868 and ADE7878 only, to allow energy accumulation based on current rms values when the missing neutral case demonstrates to be a tamper attack. This datapath is active also in PSM0 mode to allow for its gain calibration. The gain is used in the external microprocessor during PSM1 mode. The mav value of the neutral current is not computed using this method. Figure 55 shows the details of the signal processing chain for the mav calculation on one of the phases of the current channel. Figure 55. Current MAV Signal Processing for PSM1 Mode The current channel mav value is processed from the samples used in the current channel waveform sampling mode. The samples are passed through a high-pass filter to eliminate the eventual dc offsets introduced by the ADCs and the absolute values are computed. The outputs of this block are then filtered to obtain the average. The current mav values are unsigned 20-bit values and they are stored in the AIMAV, BIMAV, and CIMAV registers. The update rate of this mav measurement is 8 kHz. 211000 210500 210000 209500 209000 208500 208000 08510-252 207500 207000 45 50 55 FREQUENCY (Hz) 60 65 Figure 56. xIMAV Register Values at Full Scale, 45 Hz to 65 Hz Line Frequencies The mav values of full-scale sinusoidal signals of 50 Hz and 60 Hz are 209,686 and 210,921, respectively. As seen in Figure 56, there is a 1.25% variation between the mav estimate at 45 Hz and the one at 65 Hz for full-scale sinusoidal inputs. The accuracy of the current mav is typically 0.5% error from the full-scale input down to 1/100 of the full-scale input. Additionally, this measurement has a bandwidth of 2 kHz. The settling time for the current mav measurement, that is the time it takes for the mav register to reflect the value at the input to the current channel within 0.5% error, is 500 ms. As stated in the Current Waveform Gain Registers section, the serial ports of the ADE7868/ADE7878 work on 32-, 16-, or 8bit words. As presented in Figure 57, the AIMAV, BIMAV, and CIMAV 20-bit unsigned registers are accessed as 32-bit registers with the 12 MSBs padded with 0s. 31 20 19 0000 0000 0000 0 20-BIT UNSIGNED NUMBER 08510-253 rms offset represents 0.00037% (( 41912 + 128 /4191 - 1) x 100) of the rms measurement at 60 dB down from full scale. Conduct offset calibration at low current; avoid using currents equal to zero for this purpose. 211500 LSB The ADE7854/ADE7858/ADE7868/ADE7878 incorporate a current rms offset compensation register for each phase: AIRMSOS, BIRMSOS, CIRMSOS registers, and the NIRMSOS register for ADE7878 and ADE7868 only. These are 24-bit signed registers that are used to remove offsets in the current rms calculations. An offset can exist in the rms calculation due to input noises that are integrated in the dc component of I2(t). The current rms offset compensation register is added to the squared current rms before the square root is executed. Assuming that the maximum value from the current rms calculation is 4,191,400 with full-scale ac inputs (50 Hz), one LSB of the current Figure 57. xIMAV Registers Transmitted as 32-Bit Registers Current MAV Gain and Offset Compensation The current rms values stored in the AIMAV, BIMAV, and CIMAV registers can be calibrated using gain and offset coefficients corresponding to each phase. It is recommended to calculate the gains in PSM0 mode by supplying the ADE7868/ ADE7878 with nominal currents. The offsets can be estimated by supplying the ADE7868/ADE7878 with low currents, usually equal to the minimum value at which the accuracy is required. Every time the external microcontroller reads the AIMAV, BIMAV, and CIMAV registers, it uses these coefficients stored in its memory to correct them. Voltage Channel RMS Calculation Figure 58 shows the detail of the signal processing chain for the rms calculation on one of the phases of the voltage channel. The voltage channel rms value is processed from the samples used in the voltage channel. The voltage rms values are signed 24-bit values and they are stored into the Registers AVRMS, BVRMS, and CVRMS. The update rate of the current rms measurement is 8 kHz. Rev. E | Page 42 of 96 ADE7854/ADE7858/ADE7868/ADE7878 With the specified full-scale analog input signal of 0.5 V, the ADC produces an output code that is approximately 5,928,256. The equivalent rms value of a full-scale sinusoidal signal is 4,191,910 (0x3FF6A6), independent of the line frequency. The settling time for the V rms measurement is 440 ms for both 50 Hz and 60 Hz input signals. The V rms measurement is the time it takes for the rms register to reflect the value at the input to the voltage channel when starting from 0. The accuracy of the voltage rms is typically 0.1% error from the full-scale input down to 1/1000 of the full-scale input. Additionally, this measurement has a bandwidth of 2 kHz. It is recommended to read the rms registers synchronous to the voltage zero crossings to ensure stability. The IRQ1 interrupt can be used to indicate when a zero crossing has occurred (see the Interrupts section). As stated in the Current Waveform Gain Registers section, the serial ports of the ADE78xx work on 32-, 16-, or 8-bit words. Similar to the register presented in Figure 34, the AVRMS, BVRMS, and CVRMS 24-bit signed registers are accessed as 32-bit registers with the eight MSBs padded with 0s. xVRMSOS[23:0] 27 x2 LPF xVRMS[23:0] 0x5A7540 = 5,928,256 0V 0xA58AC0 = -5,928,256 Figure 58. Voltage RMS Signal Processing Rev. E | Page 43 of 96 08510-041 VOLTAGE SIGNAL FROM HPF ADE7854/ADE7858/ADE7868/ADE7878 Voltage RMS Offset Compensation The ADE78xx incorporates voltage rms offset compensation registers for each phase: AVRMSOS, BVRMSOS, and CVRMSOS. These are 24-bit signed registers used to remove offsets in the voltage rms calculations. An offset can exist in the rms calculation due to input noises that are integrated in the dc component of V2(t). The voltage rms offset compensation register is added to the squared voltage rms before the square root is executed. Assuming that the maximum value from the voltage rms calculation is 4,191,400 with full-scale ac inputs (50 Hz), one LSB of the current rms offset represents 0.00037% (( 41912 + 128 /4191 - 1) x 100) of the rms measurement at 60 dB down from full scale. Conduct offset calibration at low current; avoid using voltages equal to zero for this purpose. + 128 x VRMSOS (15) where V rms0 is the rms measurement without offset correction. As stated in the Current Waveform Gain Registers section, the serial ports of the ADE78xx work on 32-, 16-, or 8-bit words and the DSP works on 28 bits. Similar to registers presented in Figure 33, the AVRMSOS, BVRMSOS, and CVRMSOS 24-bit registers are accessed as 32-bit registers with the four most significant bits padded with 0s and sign extended to 28 bits. ACTIVE POWER CALCULATION The ADE7854/ADE7858/ADE7868/ADE7878 compute the total active power on every phase. Total active power considers in its calculation all fundamental and harmonic components of the voltages and currents. In addition, the ADE7878 computes the fundamental active power, the power determined only by the fundamental components of the voltages and currents. Total Active Power Calculation Electrical power is defined as the rate of energy flow from source to load, and it is given by the product of the voltage and current waveforms. The resulting waveform is called the instantaneous power signal, and it is equal to the rate of energy flow at every instant of time. The unit of power is the watt or joules/sec. If an AIGAIN HPFDIS [23:0] v(t ) = Vk 2 sin (kt + k) (16) k =1 i(t ) = I k 2 sin(kt + k ) k =1 where: Vk, Ik are rms voltage and current, respectively, of each harmonic. k, k are the phase delays of each harmonic. The instantaneous power in an ac system is k =1 k =1 p(t) = v(t) x i(t) = Vk I k cos(k - k) - Vk I k cos(2kt + k + k) + Vk I m {cos[(k - m)t + k - m] - cos[(k + m)t + k + m]} k , m =1 k m (17) The average power over an integral number of line cycles (n) is given by the expression in Equation 18. P= 1 nT p(t )dt = Vk I k cos(k - k) nT 0 k =1 (18) where: T is the line cycle period. P is referred to as the total active or total real power. Note that the total active power is equal to the dc component of the instantaneous power signal p(t) in Equation 17, that is, Vk I k cos(k - k) k =1 This is the expression used to calculate the total active power in the ADE78xx for each phase. The expression of fundamental active power is obtained from Equation 18 with k = 1, as follows: FP = V1I1 cos(1 - 1) (19) Figure 59 shows how the ADE78xx computes the total active power on each phase. First, it multiplies the current and voltage signals in each phase. Next, it extracts the dc component of the instantaneous power signal in each phase (A, B, and C) using LPF2, the low-pass filter. DIGITAL INTEGRATOR AWGAIN IA AWATTOS HPF APHCAL AVGAIN HPFDIS [23:0] LPF INSTANTANEOUS PHASE A ACTIVE POWER VA AWATT HPF DIGITAL SIGNAL PROCESSOR Figure 59. Total Active Power Datapath Rev. E | Page 44 of 96 24 08510-145 V rms = V rms02 ac system is supplied by a voltage, v(t), and consumes the current, i(t), and each of them contains harmonics, then ADE7854/ADE7858/ADE7868/ADE7878 If the phase currents and voltages contain only the fundamental component, are in phase (that is 1 = 1 = 0), and they correspond to full-scale ADC inputs, then multiplying them results in an instantaneous power signal that has a dc component, V1 x I1, and a sinusoidal component, V1 x I1 cos(2t); Figure 60 shows the corresponding waveforms. INSTANTANEOUS POWER SIGNAL p(t)= V rms x I rms - V rms x I rms x cos(2t) INSTANTANEOUS ACTIVE POWER SIGNAL: V rms x I rms V rms x I rms 0x1FF6A6B = 33,516,139 0x000 0000 Fundamental Active Power Calculation--ADE7878 Only VLEVEL = 08510-043 Figure 60. Active Power Calculation Because LPF2 does not have an ideal brick wall frequency response (see Figure 61), the active power signal has some ripple due to the instantaneous power signal. This ripple is sinusoidal and has a frequency equal to twice the line frequency. Because the ripple is sinusoidal in nature, it is removed when the active power signal is integrated over time to calculate the energy. 0 U FS x 491,520 Un (21) where: UFS is the rms value of the phase voltages when the ADC inputs are at full scale. Un is the rms nominal value of the phase voltage. As stated in the Current Waveform Gain Registers section, the serial ports of the ADE7878 work on 32-, 16-, or 8-bit words and the DSP works on 28 bits. Similar to the registers presented in Figure 33, the VLEVEL 24-bit signed register is accessed as a 32-bit register with four most significant bits padded with 0s and sign extended to 28 bits. Table 14 presents the settling time for the fundamental active power measurement. -5 -10 Table 14. Settling Time for Fundamental Active Power Input Signals 100% Full Scale 875 ms -15 63% Full Scale 375 ms -20 Active Power Gain Calibration -25 0.1 1 FREQUENCY (Hz) 3 10 08510-103 MAGNITUDE (dB) The xWATT[23:0] waveform registers can be accessed using various serial ports. Refer to the Waveform Sampling Mode section for more details. The ADE7878 computes the fundamental active power using a proprietary algorithm that requires some initializations function of the frequency of the network and its nominal voltage measured in the voltage channel. Bit 14 (SELFREQ) in the COMPMODE register must be set according to the frequency of the network in which the ADE7878 is connected. If the network frequency is 50 Hz, clear this bit to 0 (the default value). If the network frequency is 60 Hz, set this bit to 1. In addition, initialize the VLEVEL 24-bit signed register with a positive value based on the following expression: 0x3FED4D6 67,032,278 i(t) = 2 x I rms x sin(t) v(t) = 2 x V rms x sin(t) PMAX = 33,516,139; it is the instantaneous power computed when the ADC inputs are at full scale and in phase. Figure 61. Frequency Response of the LPF Used to Filter Instantaneous Power in Each Phase The ADE7854/ADE7858/ADE7868/ADE7878 store the instantaneous total phase active powers into the AWATT, BWATT, and CWATT registers. Their expression is xWATT = Uk k =1 U FS x Ik I FS x cos(k - k) x PMAX x 1 24 (20) Note that the average active power result from the LPF2 output in each phase can be scaled by 100% by writing to the phase's watt gain 24-bit register (AWGAIN, BWGAIN, CWGAIN, AFWGAIN, BFWGAIN, or CFWGAIN). The xWGAIN registers are placed in each phase of the total active power datapath, and the xFWGAIN (available for the ADE7878 only) registers are placed in each phase of the fundamental active power datapath. The watt gain registers are twos complement, signed registers and have a resolution of 2-23/LSB. Equation 22 describes mathematically the function of the watt gain registers. Average Power Data = where: UFS, IFS are the rms values of the phase voltage and current when the ADC inputs are at full scale. Rev. E | Page 45 of 96 Watt Gain Register LPF 2 Output x 1 + 223 (22) ADE7854/ADE7858/ADE7868/ADE7878 The output is scaled by -50% by writing 0xC00000 to the watt gain registers, and it is increased by +50% by writing 0x400000 to them. These registers are used to calibrate the active power (or energy) calculation in the ADE7854/ADE7858/ADE7868/ ADE7878 for each phase. As stated in the Current Waveform Gain Registers section, the serial ports of the ADE7854/ADE7858/ADE7868/ADE7878 work on 32-, 16-, or 8-bit words, and the DSP works on 28 bits. Similar to registers presented in Figure 33, AWGAIN, BWGAIN, CWGAIN, AFWGAIN, BFWGAIN, and CFWGAIN 24-bit signed registers are accessed as 32-bit registers with the four MSBs padded with 0s and sign extended to 28 bits. Active Power Offset Calibration The ADE7854/ADE7858/ADE7868/ADE7878 incorporate a watt offset 24-bit register on each phase and on each active power. The AWATTOS, BWATTOS, and CWATTOS registers compensate the offsets in the total active power calculations, and the AFWATTOS, BFWATTOS, and CFWATTOS registers compensate offsets in the fundamental active power calculations. These are signed twos complement, 24-bit registers that are used to remove offsets in the active power calculations. An offset can exist in the power calculation due to crosstalk between channels on the PCB or in the chip itself. One LSB in the active power offset register is equivalent to 1 LSB in the active power multiplier output. With full-scale current and voltage inputs, the LPF2 output is PMAX = 33,516,139. At -80 dB down from the full scale (active power scaled down 104 times), one LSB of the active power offset register represents 0.0298% of PMAX. As stated in the Current Waveform Gain Registers section, the serial ports of the ADE7854/ADE7858/ADE7868/ADE7878 work on 32-, 16-, or 8-bit words and the DSP works on 28 bits. Similar to registers presented in Figure 33, the AWATTOS, BWATTOS, CWATTOS, AFWATTOS, BFWATTOS, and CFWATTOS 24-bit signed registers are accessed as 32-bit registers with the four MSBs padded with 0s and sign extended to 28 bits. Sign of Active Power Calculation The average active power is a signed calculation. If the phase difference between the current and voltage waveform is more than 90, the average power becomes negative. Negative power indicates that energy is being injected back on the grid. The ADE78xx has sign detection circuitry for total active power calculations. It can monitor the total active powers or the fundamental active powers. As described in the Active Energy Calculation section, the active energy accumulation is performed in two stages. Every time a sign change is detected in the energy accumulation at the end of the first stage, that is, after the energy accumulated into the internal accumulator reaches the WTHR register threshold, a dedicated interrupt is triggered. The sign of each phase active power can be read in the PHSIGN register. Bit 6 (REVAPSEL) in the ACCMODE register sets the type of active power being monitored. When REVAPSEL is 0, the default value, the total active power is monitored. When REVAPSEL is 1, the fundamental active power is monitored. Bits[8:6] (REVAPC, REVAPB, and REVAPA, respectively) in the STATUS0 register are set when a sign change occurs in the power selected by Bit 6 (REVAPSEL) in the ACCMODE register. Bits[2:0] (CWSIGN, BWSIGN, and AWSIGN, respectively) in the PHSIGN register are set simultaneously with the REVAPC, REVAPB, and REVAPA bits. They indicate the sign of the power. When they are 0, the corresponding power is positive. When they are 1, the corresponding power is negative. Bit REVAPx of STATUS0 and Bit xWSIGN in the PHSIGN register refer to the total active power of Phase x, the power type being selected by Bit 6 (REVAPSEL) in the ACCMODE register. Interrupts attached to Bits[8:6] (REVAPC, REVAPB, and REVAPA, respectively) in the STATUS0 register can be enabled by setting Bits[8:6] in the MASK0 register. If enabled, the IRQ0 pin is set low, and the status bit is set to 1 whenever a change of sign occurs. To find the phase that triggered the interrupt, the PHSIGN register is read immediately after reading the STATUS0 register. Next, the status bit is cleared and the IRQ0 pin is returned to high by writing to the STATUS0 register with the corresponding bit set to 1. Active Energy Calculation As previously stated, power is defined as the rate of energy flow. This relationship can be expressed mathematically as Power = dEnergy dt (23) Conversely, energy is given as the integral of power, as follows: Energy = p (t )dt (24) Total and fundamental active energy accumulations are always signed operations. Negative energy is subtracted from the active energy contents. Rev. E | Page 46 of 96 ADE7854/ADE7858/ADE7868/ADE7878 AIGAIN HPFDIS [23:0] DIGITAL INTEGRATOR REVAPA BIT IN STATUS0[31:0] IA HPF APHCAL AVGAIN AWGAIN AWATTOS AWATTHR[31:0] HPFDIS [23:0] ACCUMULATOR LPF2 32-BIT REGISTER VA HPF WTHR[47:0] 08510-044 AWATT 24 DIGITAL SIGNAL PROCESSOR Figure 62. Total Active Energy Accumulation The ADE7854/ADE7858/ADE7868/ADE7878 achieve the integration of the active power signal in two stages (see Figure 62). The process is identical for both total and fundamental active powers. The first stage is accomplished inside the DSP: every 125 s (8 kHz frequency) the instantaneous phase total or fundamental active power is accumulated into an internal register. When a threshold is reached, a pulse is generated at the processor port, and the threshold is subtracted from the internal register. The sign of the energy in this moment is considered the sign of the active power (see Sign of Active Power Calculation section for details). The second stage is done outside the DSP and consists of accumulating the pulses generated by the processor into internal 32-bit accumulation registers. The content of these registers is transferred to watt-hour registers, xWATTHR and xFWATTHR, when these registers are accessed. WTHR[47:0] where: PMAX = 33,516,139 = 0x1FF6A6B as the instantaneous power computed when the ADC inputs are at full scale. fS = 8 kHz, the frequency with which the DSP computes the instantaneous power. UFS, IFS are the rms values of phase voltages and currents when the ADC inputs are at full scale. The maximum value that can be written on WTHR is 247 - 1. The minimum value is 0x0, but it is recommended to write a number equal to or greater than PMAX. Never use negative numbers. WTHR is a 48-bit register. As stated in the Current Waveform Gain Registers section, the serial ports of the ADE7854/ADE7858/ ADE7868/ADE7878 work on 32-, 16-, or 8-bit words. As shown in Figure 64, the WTHR register is accessed as two 32-bit registers (WTHR1 and WTHR0), each having eight MSBs padded with 0s. ACTIVE POWER ACCUMULATION IN DSP WTHR[47:0] 31 24 23 1 DSP PULSE = 1LSB OF WATTHR[31:0] 08510-045 0000 0000 DSP GENERATED PULSES WTHR = PMAX x f S x 3600 x 10 n U FS x I FS (25) 0 24 BIT SIGNED NUMBER 23 0 31 0000 0000 WTHR1[31:0] 24 23 0 24 BIT SIGNED NUMBER WTHR0[31:0] Figure 64. WTHR[47:0] Communicated As Two 32-Bit Registers Figure 63. Active Power Accumulation Inside the DSP Figure 63 explains this process. The WTHR 48-bit signed register contains the threshold. It is introduced by the user and is common for all phase total active and fundamental powers. Its value depends on how much energy is assigned to one LSB of watthour registers. Supposing a derivative of wh [10n wh], n as an integer, is desired as one LSB of the xWATTHR register. Then WTHR is computed using the following expression: 24 08510-046 47 This discrete time accumulation or summation is equivalent to integration in continuous time following the description in Equation 26. Energy = p (t )dt = Lim p (nT ) x T T0 n=0 (26) where: n is the discrete time sample number. T is the sample period. In the ADE7854/ADE7858/ADE7868/ADE7878, the total phase active powers are accumulated in the AWATTHR, BWATTHR, and CWATTHR 32-bit signed registers, and the fundamental phase active powers are accumulated in AFWATTHR, BFWATTHR, and Rev. E | Page 47 of 96 ADE7854/ADE7858/ADE7868/ADE7878 CFWATTHR 32-bit signed registers. The active energy register content can roll over to full-scale negative (0x80000000) and continue increasing in value when the active power is positive. Conversely, if the active power is negative, the energy register underflows to full-scale positive (0x7FFFFFFF) and continues decreasing in value. Table 15. Inputs to Watt-Hour Accumulation Registers CONSEL 00 01 10 AWATTHR VA x IA VA x IA VA x IA Bit 0 (AEHF) in the STATUS0 register is set when Bit 30 of one of the xWATTHR registers changes, signifying one of these registers is half full. If the active power is positive, the watt-hour register becomes half full when it increments from 0x3FFF FFFF to 0x4000 0000. If the active power is negative, the watt-hour register becomes half full when it decrements from 0xC000 0000 to 0xBFFF FFFF. Similarly, Bit 1 (FAEHF) in STATUS0 register, is set when Bit 30 of one of the xFWATTHR registers changes, signifying one of these registers is half full. 11 VA x IA Setting Bits[1:0] in the MASK0 register enable the FAEHF and AEHF interrupts, respectively. If enabled, the IRQ0 pin is set low and the status bit is set to 1 whenever one of the energy registers, xWATTHR (for the AEHF interrupt) or xFWATTHR (for the FAEHF interrupt), become half full. The status bit is cleared and the IRQ0 pin is set to logic high by writing to the STATUS0 register with the corresponding bit set to 1. Setting Bit 6 (RSTREAD) of the LCYCMODE register enables a read-with-reset for all watt-hour accumulation registers, that is, the registers are reset to 0 after a read operation. Integration Time Under Steady Load The discrete time sample period (T) for the accumulation register is 125 s (8 kHz frequency). With full-scale sinusoidal signals on the analog inputs and the watt gain registers set to 0x00000, the average word value from each LPF2 is PMAX = 33,516,139 = 0x1FF6A6B. If the WTHR register threshold is set at the PMAX level, this means the DSP generates a pulse that is added at watthour registers every 125 s. The maximum value that can be stored in the watt-hour accumulation register before it overflows is 231 - 1 or 0x7FFFFFFF. The integration time is calculated as Time = 0x7FFF,FFFF x 125 s = 74 hr 33 min 55 sec (27) Energy Accumulation Modes The active power accumulated in each watt-hour accumulation 32-bit register (AWATTHR, BWATTHR, CWATTHR, AFWATTHR, BFWATTHR, and CFWATTHR) depends on the configuration of Bit 5 and Bit 4 (CONSEL bits) in the ACCMODE register. The various configurations are described in Table 15. BWATTHR VB x IB 0 VB x IB VB = -VA - VC VB x IB VB = -VA CWATTHR VC x IC VC x IC VC x IC VC x IC Depending on the polyphase meter service, choose the appropriate formula to calculate the active energy. The American ANSI C12.10 standard defines the different configurations of the meter. Table 16 describes which mode to choose in these various configurations. Table 16. Meter Form Configuration ANSI Meter Form 5S/13S 6S/14S 8S/15S 9S/16S Configuration 3-wire delta 4-wire wye 4-wire delta 4-wire wye CONSEL 01 10 11 00 Bits[1:0] (WATTACC[1:0]) in the ACCMODE register determine how the CF frequency output can be generated as a function of the total and fundamental active powers. Whereas the watt-hour accumulation registers accumulate the active power in a signed format, the frequency output can be generated in signed mode or in absolute mode as a function of the WATTACC[1:0] bits. See the Energy-to-Frequency Conversion section for details. Line Cycle Active Energy Accumulation Mode In line cycle energy accumulation mode, the energy accumulation is synchronized to the voltage channel zero crossings such that active energy is accumulated over an integral number of half line cycles. The advantage of summing the active energy over an integer number of line cycles is that the sinusoidal component in the active energy is reduced to 0. This eliminates any ripple in the energy calculation and allows the energy to be accumulated accurately over a shorter time. By using the line cycle energy accumulation mode, the energy calibration can be greatly simplified, and the time required to calibrate the meter can be significantly reduced. In line cycle energy accumulation mode, the ADE7854/ADE7858/ADE7868/ADE7878 transfer the active energy accumulated in the 32-bit internal accumulation registers into the xWATHHR or xFWATTHR registers after an integral number of line cycles, as shown in Figure 65. The number of half line cycles is specified in the LINECYC register. Rev. E | Page 48 of 96 ADE7854/ADE7858/ADE7868/ADE7878 ZXSEL[0] IN LCYCMODE[7:0] Therefore, total energy accumulated using the line cycle accumulation mode is ZEROCROSSING DETECTION (PHASE A) e= ZXSEL[1] IN LCYCMODE[7:0] LINECYC[15:0] ZEROCROSSING DETECTION (PHASE B) t +nT t k =1 p (t )dt = nT Vk I k cos(k - k) (28) where nT is the accumulation time. Note that line cycle active energy accumulation uses the same signal path as the active energy accumulation. The LSB size of these two methods is equivalent. CALIBRATION CONTROL ZXSEL[2] IN LCYCMODE[7:0] REACTIVE POWER CALCULATION--ADE7858, ADE7868, ADE7878 ONLY ZEROCROSSING DETECTION (PHASE C) The ADE7858/ADE7868/ADE7878 can compute the total reactive power on every phase. Total reactive power integrates all fundamental and harmonic components of the voltages and currents. The ADE7878 also computes the fundamental reactive power, the power determined only by the fundamental components of the voltages and currents. AWATTOS AWGAIN AWATTHR[31:0] OUTPUT FROM LPF2 WTHR[47:0] 32-BIT REGISTER 08510-147 ACCUMULATOR Figure 65. Line Cycle Active Energy Accumulation Mode The line cycle energy accumulation mode is activated by setting Bit 0 (LWATT) in the LCYCMODE register. The energy accumulation over an integer number of half line cycles is written to the watt-hour accumulation registers after LINECYC number of half line cycles is detected. When using the line cycle accumulation mode, the Bit 6 (RSTREAD) of the LCYCMODE register should be set to Logic 0 because the read with reset of watt-hour registers is not available in this mode. A load that contains a reactive element (inductor or capacitor) produces a phase difference between the applied ac voltage and the resulting current. The power associated with reactive elements is called reactive power, and its unit is VAR. Reactive power is defined as the product of the voltage and current waveforms when all harmonic components of one of these signals are phase shifted by 90. Equation 31 gives an expression for the instantaneous reactive power signal in an ac system when the phase of the current channel is shifted by +90. v(t ) = Vk 2 sin(kt + k) Phase A, Phase B, and Phase C zero crossings are, respectively, included when counting the number of half line cycles by setting Bits[5:3] (ZXSEL[x]) in the LCYCMODE register. Any combination of the zero crossings from all three phases can be used for counting the zero crossing. Select only one phase at a time for inclusion in the zero crossings count during calibration. The number of zero crossings is specified by the LINECYC 16-bit unsigned register. The ADE78xx can accumulate active power for up to 65,535 combined zero crossings. Note that the internal zero-crossing counter is always active. By setting Bit 0 (LWATT) in the LCYCMODE register, the first energy accumulation result is, therefore, incorrect. Writing to the LINECYC register when the LWATT bit is set resets the zero-crossing counter, thus ensuring that the first energy accumulation result is accurate. At the end of an energy calibration cycle, Bit 5 (LENERGY) in the STATUS0 register is set. If the corresponding mask bit in the MASK0 interrupt mask register is enabled, the IRQ0 pin also goes active low. The status bit is cleared and the IRQ0 pin is set to high again by writing to the STATUS0 register with the corresponding bit set to 1. Because the active power is integrated on an integer number of half-line cycles in this mode, the sinusoidal components are reduced to 0, eliminating any ripple in the energy calculation. (29) k =1 i(t ) = I k 2 sin(kt + k ) (30) k =1 i ' (t ) = I k 2 sin kt + k + 2 k =1 where i(t) is the current waveform with all harmonic components phase shifted by 90. Next, the instantaneous reactive power, q(t), can be expressed as q(t) = v(t) x i(t) (31) q(t ) = Vk I k x 2 sin(kt + k) x sin(kt + k + k =1 Vk I m x 2sin(kt + k) x sin(mt + m + k ,m =1 k m )+ 2 ) 2 Note that q(t) can be rewritten as { q(t ) = Vk I k cos(k - k - k =1 V kI m k ,m =1 k m Rev. E | Page 49 of 96 2 ) - cos(2 kt + + + )} + k {cos[(k - m)t + - - 2 ]} k k k 2 (32) ADE7854/ADE7858/ADE7868/ADE7878 The average total reactive power over an integral number of line cycles (n) is given by the expression in Equation 33. Q= 1 nT nT 0 k =1 q(t )dt = Vk I k cos(k - k - ) 2 (33) Q = Vk I k sin(k - k) k =1 where: T is the period of the line cycle. Q is referred to as the total reactive power. Note that the total reactive power is equal to the dc component of the instantaneous reactive power signal q(t) in Equation 32, that is, Reactive Power Gain Calibration The average reactive power from the LPF output in each phase can be scaled by 100% by writing to one of the phase's VAR gain 24-bit register (AVARGAIN, BVARGAIN, CVARGAIN, AFVARGAIN, BFVARGAIN, or CFVARGAIN). The xVARGAIN registers are placed in each phase of the total reactive power datapath. The xFVARGAIN registers are placed in each phase of the fundamental reactive power datapath. The xVARGAIN registers are twos complement signed registers and have a resolution of 2-23/LSB. The function of the xVARGAIN registers is expressed by Average Reactive Power = xVARGAIN Register LPF 2 Output x 1 + 223 Vk I k sin(k - k) k =1 This is the relationship used to calculate the total reactive power in the ADE7858/ADE7868/ADE7878 for each phase. The instantaneous reactive power signal, q(t), is generated by multiplying each harmonic of the voltage signals by the 90 phaseshifted corresponding harmonic of the current in each phase. The ADE7858/ADE7868/ADE7878 store the instantaneous total phase reactive powers into the AVAR, BVAR, and CVAR registers. Their expression is Uk I 1 x k x sin(k - k) x PMAX x 4 U I 2 k =1 FS FS xVAR = (34) where: UFS, IFS are the rms values of the phase voltage and current when the ADC inputs are at full scale. PMAX = 33,516,139, the instantaneous power computed when the ADC inputs are at full scale and in phase. The xVAR waveform registers can be accessed using various serial ports. Refer to the Waveform Sampling Mode section for more details. The expression of fundamental reactive power is obtained from Equation 33 with k = 1, as follows: FQ = V1I1 sin(1 - 1) The ADE7878 computes the fundamental reactive power using a proprietary algorithm that requires some initialization function of the frequency of the network and its nominal voltage measured in the voltage channel. These initializations are introduced in the Active Power Calculation section and are common for both fundamental active and reactive powers. Table 17 presents the settling time for the fundamental reactive power measurement, which is the time it takes the power to reflect the value at the input of the ADE7878. Table 17. Settling Time for Fundamental Reactive Power 63% Full Scale 375 ms Input Signals 100% Full Scale 875 ms (35) The output is scaled by -50% by writing 0xC00000 to the xVARGAIN registers and increased by +50% by writing 0x400000 to them. These registers can be used to calibrate the reactive power (or energy) gain in the ADE78xx for each phase. As stated in the Current Waveform Gain Registers section, the serial ports of the ADE7858/ADE7868/ADE7878 work on 32-, 16-, or 8-bit words and the DSP works on 28 bits. Similar to registers presented in Figure 33, the AVARGAIN, BVARGAIN, CVARGAIN, AFVARGAIN, BFVARGAIN, and CFVARGAIN 24-bit signed registers are accessed as 32-bit registers with the four MSBs padded with 0s and sign extended to 28 bits. Reactive Power Offset Calibration The ADE7858/ADE7868/ADE7878 provide a reactive power offset register on each phase and on each reactive power. AVAROS, BVAROS, and CVAROS registers compensate the offsets in the total reactive power calculations, whereas AFVAROS, BFVAROS, and CFVAROS registers compensate offsets in the fundamental reactive power calculations. These are signed twos complement, 24-bit registers that are used to remove offsets in the reactive power calculations. An offset can exist in the power calculation due to crosstalk between channels on the PCB or in the chip itself. The offset resolution of the registers is the same as for the active power offset registers (see the Active Power Offset Calibration section). As stated in the Current Waveform Gain Registers section, the serial ports of the ADE7858/ADE7868/ADE7878 work on 32-, 16-, or 8-bit words and the DSP works on 28 bits. Similar to the registers presented in Figure 33, the AVAROS, BVAROS, and CVAROS 24-bit signed registers are accessed as 32-bit registers with the four MSBs padded with 0s and sign extended to 28 bits. Sign of Reactive Power Calculation Note that the reactive power is a signed calculation. Table 18 summarizes the relationship between the phase difference between the voltage and the current and the sign of the resulting reactive power calculation. Rev. E | Page 50 of 96 ADE7854/ADE7858/ADE7868/ADE7878 The ADE7858/ADE7868/ADE7878 have sign detection circuitry for reactive power calculations that can monitor the total reactive powers or the fundamental reactive powers. As described in the Reactive Energy Calculation section, the reactive energy accumulation is executed in two stages. Every time a sign change is detected in the energy accumulation at the end of the first stage, that is, after the energy accumulated into the internal accumulator reaches the VARTHR register threshold, a dedicated interrupt is triggered. The sign of each phase reactive power can be read in the PHSIGN register. Bit 7 (REVRPSEL) in the ACCMODE register sets the type of reactive power being monitored. When REVRPSEL is 0, the default value, the total reactive power is monitored. When REVRPSEL is 1, then the fundamental reactive power is monitored. Similar to active power, the ADE7858/ADE7868/ADE7878 achieve the integration of the reactive power signal in two stages (see Figure 66). The process is identical for both total and fundamental active powers. * * Bits[12:10] (REVRPC, REVRPB, and REVRPA, respectively) in the STATUS0 register are set when a sign change occurs in the power selected by Bit 7 (REVRPSEL) in the ACCMODE register. Bits[6:4] (CVARSIGN, BVARSIGN, and AVARSIGN, respectively) in the PHSIGN register are set simultaneously with the REVRPC, REVRPB, and REVRPA bits. They indicate the sign of the reactive power. When they are 0, the reactive power is positive. When they are 1, the reactive power is negative. Bit REVRPx of the STATUS0 register and Bit xVARSIGN in the PHSIGN register refer to the reactive power of Phase x, the power type being selected by Bit REVRPSEL in ACCMODE register. Setting Bits[12:10] in the MASK0 register enables the REVRPC, REVRPB, and REVRPA interrupts, respectively. If enabled, the IRQ0 pin is set low and the status bit is set to 1 whenever a change of sign occurs. To find the phase that triggered the interrupt, the PHSIGN register is read immediately after reading the STATUS0 register. Next, the status bit is cleared and the IRQ0 pin is set to high by writing to the STATUS0 register with the corresponding bit set to 1. Table 18. Sign of Reactive Power Calculation 1 Between 0 to +180 Between -180 to 0 Between 0 to +180 Between -180 to 0 1 Integrator Off Off On On Sign of Reactive Power Positive Negative Positive Negative is defined as the phase angle of the voltage signal minus the current signal; that is, is positive if the load is inductive and negative if the load is capacitive. Reactive Energy Calculation Reactive energy is defined as the integral of reactive power. Reactive Energy = q(t)dt (36) The first stage is conducted inside the DSP: every 125 s (8 kHz frequency), the instantaneous phase total reactive or fundamental power is accumulated into an internal register. When a threshold is reached, a pulse is generated at the processor port and the threshold is subtracted from the internal register. The sign of the energy in this moment is considered the sign of the reactive power (see the Sign of Reactive Power Calculation section for details). The second stage is performed outside the DSP and consists in accumulating the pulses generated by the processor into internal 32-bit accumulation registers. The content of these registers is transferred to the var-hour registers (xVARHR and xFVARHR) when these registers are accessed. AVARHR, BVARHR, CVARHR, AFWATTHR, BFWATTHR, and CFWATTHR represent phase fundamental reactive powers. Figure 63 from the Active Energy Calculation section explains this process. The VARTHR 48-bit signed register contains the threshold and it is introduced by the user. It is introduced by the user and is common for both total and fundamental phase reactive powers. Its value depends on how much energy is assigned to one LSB of var-hour registers. Supposing a derivative of a volt ampere reactive hour (varh) at [10n varh] where n is an integer, is desired as one LSB of the VARHR register. Then, the VARTHR register can be computed using the following equation: VARTHR = PMAX x f s x 3600 x 10n U FS x I FS where: PMAX = 33,516,139 = 0x1FF6A6B, the instantaneous power computed when the ADC inputs are at full scale. fS = 8 kHz, the frequency with which the DSP computes the instantaneous power. UFS, IFS are the rms values of phase voltages and currents when the ADC inputs are at full scale. The maximum value that may be written on the VARTHR register is 247 - 1. The minimum value is 0x0, but it is recommended to write a number equal to or greater than PMAX. Never use negative numbers. VARTHR is a 48-bit register. As previously stated in the Voltage Waveform Gain Registers section, the serial ports of the ADE7858/ ADE7868/ADE7878 work on 32-, 16-, or 8-bit words. Similar to the WTHR register shown in Figure 64, VARTHR is accessed as two 32-bit registers (VARTHR1 and VARTHR0), each having eight MSBs padded with 0s. Both total and fundamental reactive energy accumulations are always a signed operation. Negative energy is subtracted from the reactive energy contents. Rev. E | Page 51 of 96 ADE7854/ADE7858/ADE7868/ADE7878 This discrete time accumulation or summation is equivalent to integration in continuous time following the expression in Equation 37: ReactiveEnergy = q (t )dt = Lim q (nT ) x T T0 n=0 Bit 2 (REHF) in the STATUS0 register is set when Bit 30 of one of the xVARHR registers changes, signifying one of these registers is half full. If the reactive power is positive, the var-hour register becomes half full when it increments from 0x3FFF FFFF to 0x4000 0000. If the reactive power is negative, the var-hour register becomes half full when it decrements from 0xC000 0000 to 0xBFFF FFFF. Analogously, Bit 3 (FREHF) in the STATUS0 register is set when Bit 30 of one of the xFVARHR registers changes, signifying one of these registers is half full. (37) where: n is the discrete time sample number. T is the sample period. Setting Bits[3:2] in the MASK0 register enable the FREHF and REHF interrupts, respectively. If enabled, the IRQ0 pin is set low and the status bit is set to 1 whenever one of the energy registers, xVARHR (for REHF interrupt) or xFVARHR (for FREHF interrupt), becomes half full. The status bit is cleared and the IRQ0 pin is set to high by writing to the STATUS0 register with the corresponding bit set to 1. On the ADE7858/ADE7868/ADE7878, the total phase reactive powers are accumulated in the AVARHR, BVARHR, and CVARHR 32-bit signed registers. The fundamental phase reactive powers are accumulated in the AFVARHR, BFVARHR, and CFVARHR 32-bit signed registers. The reactive energy register content can roll over to full-scale negative (0x80000000) and continue increasing in value when the reactive power is positive. Conversely, if the reactive power is negative, the energy register underflows to full-scale positive (0x7FFFFFFF) and continues to decrease in value. HPFDIS [23:0] DIGITAL INTEGRATOR AVARGAIN REVRPA BIT IN STATUS0[31:0] IA AVAROS HPF APHCAL AVGAIN HPFDIS [23:0] AVARHR[31:0] TOTAL REACTIVE POWER ALGORITHM ACCUMULATOR VA VARTHR[47:0] HPF 32-BIT REGISTER AVAR 24 DIGITAL SIGNAL PROCESSOR Figure 66. Total Reactive Energy Accumulation Rev. E | Page 52 of 96 08510-245 AIGAIN Setting Bit 6 (RSTREAD) of the LCYCMODE register enables a read-with-reset for all var-hour accumulation registers, that is, the registers are reset to 0 after a read operation. ADE7854/ADE7858/ADE7868/ADE7878 Integration Time Under A Steady Load The discrete time sample period (T) for the accumulation register is 125 s (8 kHz frequency). With full-scale pure sinusoidal signals on the analog inputs and a 90 phase difference between the voltage and the current signal (the largest possible reactive power), the average word value representing the reactive power is PMAX = 33,516,139 = 0x1FF6A6B. If the VARTHR threshold is set at the PMAX level, this means the DSP generates a pulse that is added at the var-hour registers every 125 s. The maximum value that can be stored in the var-hour accumulation register before it overflows is 231 - 1 or 0x7FFFFFFF. The integration time is calculated as Time = 0x7FFF,FFFF x 125 s = 74 hr 33 min 55 sec (38) In this mode, the ADE7858/ADE7868/ADE7878 transfer the reactive energy accumulated in the 32-bit internal accumulation registers into the xVARHR or xFVARHR registers after an integral number of line cycles, as shown in Figure 67. The number of half line cycles is specified in the LINECYC register. The line cycle reactive energy accumulation mode is activated by setting Bit 1 (LVAR) in the LCYCMODE register. The total reactive energy accumulated over an integer number of half line cycles or zero crossings is available in the var-hour accumulation registers after the number of zero crossings specified in the LINECYC register is detected. When using the line cycle accumulation mode, Bit 6 (RSTREAD) of the LCYCMODE register should be set to Logic 0 because a read with the reset of var-hour registers is not available in this mode. Energy Accumulation Modes ZXSEL[0] IN LCYCMODE[7:0] The reactive power accumulated in each var-hour accumulation 32-bit register (AVARHR, BVARHR, CVARHR, AFVARHR, BFVARHR, and CFVARHR) depends on the configuration of Bits[5:4] (CONSEL[1:0]) in the ACCMODE register, in correlation with the watt-hour registers. The different configurations are described in Table 19. Note that IA'/IB'/IC' are the phase-shifted current waveforms. ZEROCROSSING DETECTION (PHASE A) ZXSEL[1] IN LCYCMODE[7:0] ZEROCROSSING DETECTION (PHASE B) Table 19. Inputs to Var-Hour Accumulation Registers 11 VA x IA' BVARHR, BFVARHR VB x IB' 0 VB x IB' VB = -VA - VC VB x IB' VB = -VA CVARHR, CFVARHR VC x IC' VC x IC' VC x IC' CALIBRATION CONTROL ZXSEL[2] IN LCYCMODE[7:0] ZEROCROSSING DETECTION (PHASE C) AVAROS AVARGAIN VC x IC' Bits[3:2] (VARACC[1:0]) in the ACCMODE register determine how CF frequency output can be a generated function of the total active and fundamental powers. While the var-hour accumulation registers accumulate the reactive power in a signed format, the frequency output can be generated in either the signed mode or the sign adjusted mode function of VARACC[1:0]. See the Energy-toFrequency Conversion section for details. Line Cycle Reactive Energy Accumulation Mode As mentioned in the Line Cycle Active Energy Accumulation Mode section, in line cycle energy accumulation mode, the energy accumulation can be synchronized to the voltage channel zero crossings so that reactive energy can be accumulated over an integral number of half line cycles. OUTPUT FROM TOTAL REACTIVE POWER ALGORITHM AVARHR[31:0] ACCUMULATOR VARTHR[47:0] 32-BIT REGISTER Figure 67. Line Cycle Reactive Energy Accumulation Mode Phase A, Phase B, and Phase C zero crossings are, respectively, included when counting the number of half line cycles by setting Bits[5:3] (ZXSEL[x]) in the LCYCMODE register. Any combination of the zero crossings from all three phases can be used for counting the zero crossing. Select only one phase at a time for inclusion in the zero-crossings count during calibration. For details on setting the LINECYC register and the Bit 5 (LENERGY) in the MASK0 interrupt mask register associated with the line cycle accumulation mode, see the Line Cycle Active Energy Accumulation Mode section. Rev. E | Page 53 of 96 08510-146 CONSEL[1:0] 00 01 10 AVARHR, AFVARHR VA x IA' VA x IA' VA x IA' LINECYC[15:0] ADE7854/ADE7858/ADE7868/ADE7878 The ADE7854/ADE7858/ADE7868/ADE7878 store the instantaneous phase apparent powers into the AVA, BVA, and CVA registers. Their expression is APPARENT POWER CALCULATION Apparent power is defined as the maximum power that can be delivered to a load. One way to obtain the apparent power is by multiplying the voltage rms value by the current rms value (also called the arithmetic apparent power) S = V rms x I rms xVA = (39) where: S is the apparent power. V rms and I rms are the rms voltage and current, respectively. The ADE7854/ADE7858/ADE7868/ADE7878 compute the arithmetic apparent power on each phase. Figure 68 illustrates the signal processing in each phase for the calculation of the apparent power in the ADE78xx. Because V rms and I rms contain all harmonic information, the apparent power computed by the ADE78xx is total apparent power. The ADE7878 does not compute fundamental apparent power because it does not measure the rms values of the fundamental voltages and currents. AIRMS U I 1 x x PMAX x 4 U FS I FS 2 where: U, I are the rms values of the phase voltage and current. UFS, IFS are the rms values of the phase voltage and current when the ADC inputs are at full scale. PMAX = 33,516,139, the instantaneous power computed when the ADC inputs are at full scale and in phase. The xVA[23:0] waveform registers may be accessed using various serial ports. Refer to the Waveform Sampling Mode section for more details. The ADE7854/ADE7858/ADE7868/ADE7878 can compute the apparent power in an alternative way by multiplying the phase rms current by an rms voltage introduced externally. See the Apparent Power Calculation Using VNOM section for details. AVAGAIN AVAHR[31:0] ACCUMULATOR 32-BIT REGISTER VATHR[47:0] AVRMS 24 DIGITAL SIGNAL PROCESSOR Figure 68. Apparent Power Data Flow and Apparent Energy Accumulation Rev. E | Page 54 of 96 08510-048 AVA (40) ADE7854/ADE7858/ADE7868/ADE7878 Apparent Power Gain Calibration The average apparent power result in each phase can be scaled by 100% by writing to one of the phase's VAGAIN 24-bit registers (AVAGAIN, BVAGAIN, or CVAG AIN). The VAGAIN registers are twos complement, signed registers and have a resolution of 2-23/LSB. The function of the xVAGAIN registers is expressed mathematically as As stated in the Current Waveform Gain Registers, the serial ports of the ADE78xx work on 32-, 16-, or 8-bit words. Similar to the register presented in Figure 34, the VNOM 24-bit signed register is accessed as a 32-bit register with the eight MSBs padded with 0s. Apparent Energy Calculation Apparent energy is defined as the integral of apparent power. Average Apparent Power = VAGAIN Register V rms x I rms x 1 + 2 23 Apparent Energy = s(t)dt (41) The output is scaled by -50% by writing 0xC00000 to the xVAGAIN registers, and it is increased by +50% by writing 0x400000 to them. These registers calibrate the apparent power (or energy) calculation in the ADE7854/ADE7858/ADE7868/ ADE7878 for each phase. As previously stated in the Current Waveform Gain Registers section, the serial ports of the ADE78xx work on 32-, 16-, or 8-bit words and the DSP works on 28 bits. Similar to registers presented in Figure 33, the AVAGAIN, BVAGAIN, and CVAGAIN 24-bit registers are accessed as 32-bit registers with the four MSBs padded with 0s and sign extended to 28 bits. Apparent Power Offset Calibration Each rms measurement includes an offset compensation register to calibrate and eliminate the dc component in the rms value (see the Root Mean Square Measurement section). The voltage and current rms values are multiplied together in the apparent power signal processing. As no additional offsets are created in the multiplication of the rms values, there is no specific offset compensation in the apparent power signal processing. The offset compensation of the apparent power measurement in each phase is accomplished by calibrating each individual rms measurement. Apparent Power Calculation Using VNOM The ADE7854/ADE7858/ADE7868/ADE7878 can compute the apparent power by multiplying the phase rms current by an rms voltage introduced externally in the VNOM 24-bit signed register. When one of Bits[13:11] (VNOMCEN, VNOMBEN, or VNOMAEN) in the COMPMODE register is set to 1, the apparent power in the corresponding phase (Phase x for VNOMxEN) is computed in this way. When the VNOMxEN bits are cleared to 0, the default value, then the arithmetic apparent power is computed. The VNOM register contains a number determined by U, the desired rms voltage, and U FS , the rms value of the phase voltage when the ADC inputs are at full scale: U VNOM = x 4,191,910 U FS where U is the nominal phase rms voltage. (43) Similar to active and reactive powers, the ADE7854/ADE7858/ ADE7868/ADE7878 achieve the integration of the apparent power signal in two stages (see Figure 68). The first stage is conducted inside the DSP: every 125 s (8 kHz frequency), the instantaneous phase apparent power is accumulated into an internal register. When a threshold is reached, a pulse is generated at the processor port and the threshold is subtracted from the internal register. The second stage is conducted outside the DSP and consists of accumulating the pulses generated by the processor into internal 32-bit accumulation registers. The content of these registers is transferred to the VA-hour registers, xVAHR, when these registers are accessed. Figure 63 from the Active Energy Calculation section illustrates this process. The VATHR 48-bit register contains the threshold. Its value depends on how much energy is assigned to one LSB of the VA-hour registers. When a derivative of apparent energy (VAh) of [10n VAh], where n is an integer, is desired as one LSB of the xVAHR register; then, the xVATHR register can be computed using the following equation: VATHR = PMAX x f s x 3600 x 10 n U FS x I FS where: PMAX = 33,516,139 = 0x1FF6A6B, the instantaneous power computed when the ADC inputs are at full scale. fS = 8 kHz, the frequency with which the DSP computes the instantaneous power. UFS, IFS are the rms values of phase voltages and currents when the ADC inputs are at full scale. VATHR is a 48-bit register. As previously stated in the Current Waveform Gain Registers section, the serial ports of the ADE7854/ ADE7858/ADE7868/ADE7878 work on 32-, 16-, or 8-bit words. Similar to the WTHR register presented in Figure 64, the VATHR register is accessed as two 32-bit registers (VATHR1 and VATHR0), each having eight MSBs padded with 0s. This discrete time accumulation or summation is equivalent to integration in continuous time following the description in Equation 44. ApparentEnergy = s (t )dt = Lim s (nT ) x T T0 n=0 (42) where: n is the discrete time sample number. T is the sample period. Rev. E | Page 55 of 96 (44) ADE7854/ADE7858/ADE7868/ADE7878 In the ADE7854/ADE7858/ADE7868/ADE7878, the phase apparent powers are accumulated in the AVAHR, BVAHR, and CVAHR 32-bit signed registers. The apparent energy register content can roll over to full-scale negative (0x80000000) and continue increasing in value when the apparent power is positive. Conversely, if because of offset compensation in the rms datapath, the apparent power is negative, the energy register underflows to full-scale positive (0x7FFFFFFF) and continues to decrease in value. The maximum value that can be stored in the xVAHR accumulation register before it overflows is 231 - 1 or 0x7FFFFFFF. The integration time is calculated as Time = 0x7FFF,FFFF x 125 s = 74 hr 33 min 55 sec Energy Accumulation Mode The apparent power accumulated in each accumulation register depends on the configuration of Bits[5:4] (CONSEL[1:0]) in the ACCMODE register. The various configurations are described in Table 20. Bit 4 (VAEHF) in the STATUS0 register is set when Bit 30 of one of the xVAHR registers changes, signifying one of these registers is half full. As the apparent power is always positive and the xVAHR registers are signed, the VA-hour registers become half full when they increment from 0x3FFFFFFF to 0x4000 0000. Interrupts attached to Bit VAEHF in the STATUS0 register can be enabled by setting Bit 4 in the MASK0 register. If enabled, the IRQ0 pin is set low and the status bit is set to 1 whenever one of the Energy Registers xVAHR becomes half full. The status bit is cleared and the IRQ0 pin is set to high by writing to the STATUS0 register with the corresponding bit set to 1. Table 20. Inputs to VA-Hour Accumulation Registers CONSEL[1:0] 00 01 10 AVAHR AVRMS x AIRMS AVRMS x AIRMS AVRMS x AIRMS 11 AVRMS x AIRMS BVAHR BVRMS x BIRMS 0 BVRMS x BIRMS VB = -VA - VC BVRMS x BIRMS VB = -VA CVAHR CVRMS x CIRMS CVRMS x CIRMS CVRMS x CIRMS CVRMS x CIRMS Line Cycle Apparent Energy Accumulation Mode As described in the Line Cycle Active Energy Accumulation Mode section, in line cycle energy accumulation mode, the energy accumulation can be synchronized to the voltage channel zero crossings allowing apparent energy to be accumulated over an integral number of half line cycles. In this mode, the ADE7854/ ADE7858/ADE7868/ADE7878 transfer the apparent energy accumulated in the 32-bit internal accumulation registers into the xVAHR registers after an integral number of line cycles, as shown in Figure 69. The number of half line cycles is specified in the LINECYC register. Setting Bit 6 (RSTREAD) of the LCYCMODE register enables a read-with-reset for all xVAHR accumulation registers, that is, the registers are reset to 0 after a read operation. Integration Time Under Steady Load The discrete time sample period for the accumulation register is 125 s (8 kHz frequency). With full-scale pure sinusoidal signals on the analog inputs, the average word value representing the apparent power is PMAX. If the VATHR threshold register is set at the PMAX level, this means the DSP generates a pulse that is added at the xVAHR registers every 125 s. ZXSEL[0] IN LCYCMODE[7:0] ZEROCROSSING DETECTION (PHASE A) ZXSEL[1] IN LCYCMODE[7:0] LINECYC[15:0] ZEROCROSSING DETECTION (PHASE B) CALIBRATION CONTROL ZXSEL[2] IN LCYCMODE[7:0] ZEROCROSSING DETECTION (PHASE C) AVAGAIN AVAHR[31:0] ACCUMULATOR VAHR[47:0] 32-BIT REGISTER AVRMS Figure 69. Line Cycle Apparent Energy Accumulation Mode Rev. E | Page 56 of 96 08510-049 AIRMS (45) ADE7854/ADE7858/ADE7868/ADE7878 The line cycle apparent energy accumulation mode is activated by setting Bit 2 (LVA) in the LCYCMODE register. The apparent energy accumulated over an integer number of zero crossings is written to the xVAHR accumulation registers after the number of zero crossings specified in LINECYC register is detected. When using the line cycle accumulation mode, set Bit 6 (RSTREAD) of the LCYCMODE register to Logic 0 because a read with the reset of xVAHR registers is not available in this mode. Phase A, Phase B, and Phase C zero crossings are, respectively, included when counting the number of half line cycles by setting Bits[5:3] (ZXSEL[x]) in the LCYCMODE register. Any combination of the zero crossings from all three phases can be used for counting the zero crossing. Select only one phase at a time for inclusion in the zero-crossings count during calibration. For details on setting the LINECYC register and Bit 5 (LENERGY) in the MASK0 interrupt mask register associated with the line cycle accumulation mode, see the Line Cycle Active Energy Accumulation Mode section. WAVEFORM SAMPLING MODE The waveform samples of the current and voltage waveform, the active, reactive, and apparent power outputs are stored every 125 s (8 kHz rate) into 24-bit signed registers that can be accessed through various serial ports of the ADE7854/ADE7858/ ADE7868/ADE7878. Table 21 provides a list of registers and their descriptions. Table 21. Waveform Registers List Register IAWV VAWV IBWV VBWV ICWV VCWV INWV AVA BVA CVA AWATT BWATT CWATT AVAR BVAR CVAR Description Phase A current Phase A voltage Phase B current Phase B voltage Phase C current Phase C voltage Neutral current, available in the ADE7868 and ADE7878 only Phase A apparent power Phase B apparent power Phase C apparent power Phase A active power Phase B active power Phase C active power Phase A reactive power Phase B reactive power Phase C reactive power Bit 17 (DREADY) in the STATUS0 register can be used to signal when the registers listed in Table 21 can be read using I2C or SPI serial ports. An interrupt attached to the flag can be enabled by setting Bit 17 (DREADY) in the MASK0 register. See the Digital Signal Processor section for more details on Bit DREADY. The ADE7854/ADE7858/ADE7868/ADE7878 contain a high speed data capture (HSDC) port that is specially designed to provide fast access to the waveform sample registers. Read the HSDC Interface section for more details. As stated in the Current Waveform Gain Registers section, the serial ports of the ADE7854/ADE7858/ADE7868/ADE7878 work on 32-, 16-, or 8-bit words. All registers listed in Table 21 are transmitted signed extended from 24 bits to 32 bits (see Figure 35). ENERGY-TO-FREQUENCY CONVERSION The ADE7854/ADE7858/ADE7868/ADE7878 provide three frequency output pins: CF1, CF2, and CF3. The CF3 pin is multiplexed with the HSCLK pin of the HSDC interface. When HSDC is enabled, the CF3 functionality is disabled at the pin. CF1 and CF2 pins are always available. After initial calibration at manufacturing, the manufacturer or end customer verifies the energy meter calibration. One convenient way to verify the meter calibration is to provide an output frequency proportional to the active, reactive, or apparent powers under steady load conditions. This output frequency can provide a simple, single-wire, optically isolated interface to external calibration equipment. Figure 70 illustrates the energy-to-frequency conversion in the ADE7854/ADE7858/ADE7868/ADE7878. The DSP computes the instantaneous values of all phase powers: total active, fundamental active, total reactive, fundamental reactive, and apparent. The process in which the energy is sign accumulated in various xWATTHR, xVARHR, and xVAHR registers has already been described in the energy calculation sections: Active Energy Calculation, Reactive Energy Calculation, and Apparent Energy Calculation. In the energy-to-frequency conversion process, the instantaneous powers generate signals at the frequency output pins (CF1, CF2, and CF3). One digitalto-frequency converter is used for every CFx pin. Every converter sums certain phase powers and generates a signal proportional to the sum. Two sets of bits decide what powers are converted. First, Bits[2:0] (TERMSEL1[2:0]), Bits[5:3] (TERMSEL2[2:0]), and Bits[8:6] (TERMSEL3[2:0]) of the COMPMODE register decide which phases, or which combination of phases, are added. The TERMSEL1 bits refer to the CF1 pin, the TERMSEL2 bits refer to the CF2 pin, and the TERMSEL3 bits refer to the CF3 pin. The TERMSELx[0] bits manage Phase A. When set to 1, Phase A power is included in the sum of powers at the CFx converter. When cleared to 0, Phase A power is not included. The TERMSELx[1] bits manage Phase B, and the TERMSELx[2] bits manage Phase C. Setting all TERMSELx bits to 1 means all 3-phase powers are added at the CFx converter. Clearing all TERMSELx bits to 0 means no phase power is added and no CF pulse is generated. Rev. E | Page 57 of 96 ADE7854/ADE7858/ADE7868/ADE7878 Second, Bits[2:0] (CF1SEL[2:0]), Bits[5:3] (CF2SEL[2:0]), and Bits[8:6] (CF3SEL[2:0]) in the CFMODE register decide what type of power is used at the inputs of the CF1, CF2, and CF3 converters, respectively. Table 22 shows the values that CFxSEL can have: total active, total reactive (available in the ADE7858, ADE7868, and ADE7878 only), apparent, fundamental active (available in the ADE7878 only), or fundamental reactive (available in the ADE7878 only) powers. Table 22. CFxSEL Bits Description CFxSEL 000 001 010 011 100 101 to 111 INSTANTANEOUS PHASE A ACTIVE POWER Description CFx signal proportional to the sum of total phase active powers CFx signal proportional to the sum of total phase reactive powers (ADE7858/ADE7868/ ADE7878) CFx signal proportional to the sum of phase apparent powers CFx signal proportional to the sum of fundamental phase active powers (ADE7878 only) CFx signal proportional to the sum of fundamental phase reactive powers (ADE7878 only) Reserved Registers Latched When CFxLATCH = 1 AWATTHR, BWATTHR, CWATTHR AVARHR, BVARHR, CVARHR AVAHR, BVAHR, CVAHR AFWATTHR, BFWATTHR, CFWATTHR AFVARHR, BFVARHR, CFVARHR CFxSEL BITS IN CFMODE TERMSELx BITS IN COMPMODE VA INSTANTANEOUS PHASE B ACTIVE POWER WATT INSTANTANEOUS PHASE C ACTIVE POWER FWATT1 27 ACCUMULATOR VAR REVPSUMx BIT OF STATUS0[31:0] FREQUENCY DIVIDER CFx PULSE OUTPUT WTHR[47:0] FVAR1 CFxDEN DIGITAL SIGNAL PROCESSOR 08510-050 27 1FWATT AND FVAR FOR ADE7878 ONLY. Figure 70. Energy-to-Frequency Conversion Rev. E | Page 58 of 96 ADE7854/ADE7858/ADE7868/ADE7878 The second stage consists of the frequency divider by the CFxDEN 16-bit unsigned registers. The values of CFxDEN depend on the meter constant (MC), measured in impulses/kWh and how much energy is assigned to one LSB of various energy registers: xWATTHR, xVARHR, and so forth. Supposing a derivative of wh [10n wh], n a positive or negative integer, is desired as one LSB of xWATTHR register. Then, CFxDEN is as follows: CFxDEN = 103 MC[imp/kwh] x 10n (46) The derivative of wh must be chosen in such a way to obtain a CFxDEN register content greater than 1. If CFxDEN = 1, then the CFx pin stays active low for only 1 s, therefore, avoid this number. The frequency converter cannot accommodate fractional results; the result of the division must be rounded to the nearest integer. If CFxDEN is set equal to 0, then the ADE78xx considers it to be equal to 1. The pulse output for all digital-to-frequency converters stays low for 80 ms if the pulse period is larger than 160 ms (6.25 Hz). If the pulse period is smaller than 160 ms and CFxDEN is an even number, the duty cycle of the pulse output is exactly 50%. If the pulse period is smaller than 160 ms and CFxDEN is an odd number, the duty cycle of the pulse output is VDD CFx PIN Figure 71. CFx Pin Recommended Connection Bits[11:9] (CF3DIS, CF2DIS, and CF1DIS) of the CFMODE register decide if the frequency converter output is generated at the CF3, CF2, or CF1 pin. When Bit CFxDIS is set to 1 (the default value), the CFx pin is disabled and the pin stays high. When Bit CFxDIS is cleared to 0, the corresponding CFx pin output generates an active low signal. Bits[16:14] (CF3, CF2, CF1) in the Interrupt Mask Register MASK0 manage the CF3, CF2, and CF1 related interrupts. When the CFx bits are set, whenever a high-to-low transition at the corresponding frequency converter output occurs, an interrupt IRQ0 is triggered and a status bit in the STATUS0 register is set to 1. The interrupt is available even if the CFx output is not enabled by the CFxDIS bits in the CFMODE register. Synchronizing Energy Registers with CFx Outputs The ADE7854/ADE7858/ADE7868/ADE7878 contain a feature that allows synchronizing the content of phase energy accumulation registers with the generation of a CFx pulse. When a high-to-low transition at one frequency converter output occurs, the content of all internal phase energy registers that relate to the power being output at CFx pin is latched into hour registers and then resets to 0. See Table 22 for the list of registers that are latched based on the CFxSEL[2:0] bits in the CFMODE register. All 3-phase registers are latched independent of the TERMSELx bits of the COMPMODE register. The process is shown in Figure 72 for CF1SEL[2:0] = 010 (apparent powers contribute at the CF1 pin) and CFCYC = 2. The CFCYC 8-bit unsigned register contains the number of high to low transitions at the frequency converter output between two consecutive latches. Avoid writing a new value into the CFCYC register during a high-to-low transition at any CFx pin. CF1 PULSE BASED ON PHASE A AND PHASE B APPARENT POWERS (1+1/CFxDEN) x 50% CFCYC = 2 AVAHR, BVAHR, CVAHR LATCHED ENERGY REGISTERS RESET AVAHR, BVAHR, CVAHR LATCHED ENERGY REGISTERS RESET Figure 72. Synchronizing AVAHR and BVAHR with CF1 Rev. E | Page 59 of 96 08510-052 Similar to the energy accumulation process, the energy-tofrequency conversion is accomplished in two stages. In the first stage, the instantaneous phase powers obtained from the DSP at the 8 kHz rate are shifted left by seven bits and then accumulate into an internal register at a 1 MHz rate. When a threshold is reached, a pulse is generated and the threshold is subtracted from the internal register. The sign of the energy in this moment is considered the sign of the sum of phase powers (see the Sign of Sum-of-Phase Powers in the CFx Datapath section for details). The threshold is the same threshold used in various active, reactive, and apparent energy accumulators in the DSP, such as the WTHR, VARTHR, or VATHR registers, except for being shifted left by seven bits. The advantage of accumulating the instantaneous powers at the 1 MHz rate is that the ripple at the CFx pins is greatly diminished. The pulse output is active low and preferably connected to an LED, as shown in Figure 71. 08510-051 By default, the TERMSELx bits are all 1 and the CF1SEL bits are 000, the CF2SEL bits are 001, and the CF3SEL bits are 010. This means that by default, the CF1 digital-to-frequency converter produces signals proportional to the sum of all 3-phase total active powers, CF2 produces signals proportional to total reactive powers, and CF3 produces signals proportional to apparent powers. ADE7854/ADE7858/ADE7868/ADE7878 Bits[14:12] (CF3LATCH, CF2LATCH, and CF1LATCH) of the CFMODE register enable this process when set to 1. When cleared to 0, the default state, no latch occurs. The process is available even if the CFx output is not enabled by the CFxDIS bits in the CFMODE register. lated in the xVARHR registers because the powers are sign accumulated in both datapaths. CF Outputs for Various Accumulation Modes Bits[1:0] (WATTACC[1:0]) in the ACCMODE register determine the accumulation modes of the total active and fundamental powers when signals proportional to the active powers are chosen at the CFx pins (the CFxSEL[2:0] bits in the CFMODE register equal 000 or 011). When WATTACC[1:0] = 00 (the default value), the active powers are sign accumulated before entering the energyto-frequency converter. Figure 73 shows how signed active power accumulation works. In this mode, the CFx pulses synchronize perfectly with the active energy accumulated in xWATTHR registers because the powers are sign accumulated in both data paths. ACTIVE ENERGY NO-LOAD THRESHOLD ACTIVE POWER NO-LOAD THRESHOLD REVAPx BIT IN STATUS0 APNOLOAD SIGN = POSITIVE ACTIVE ENERGY POS NEG POS 08510-054 xWSIGN BIT IN PHSIGN NEG Figure 74. Active Power Absolute Accumulation Mode NO-LOAD THRESHOLD ACTIVE POWER REACTIVE ENERGY NO-LOAD THRESHOLD REVAPx BIT IN STATUS0 NO-LOAD THRESHOLD xWSIGN BIT IN PHSIGN NEG POS NEG NO-LOAD THRESHOLD Figure 73. Active Power Signed Accumulation Mode When WATTACC[1:0] = 11, the active powers are accumulated in absolute mode. When the powers are negative, they change sign and accumulate together with the positive power. Figure 74 shows how absolute active power accumulation works. Note that in this mode, the xWATTHR registers continue to accumulate active powers in signed mode, even if the CFx pulses are generated based on the absolute accumulation mode. Bits[3:2] (VARACC[1:0]) in the ACCMODE register determine the accumulation modes of the total and fundamental reactive powers when signals proportional to the reactive powers are chosen at the CFx pins (the CFxSEL[2:0] bits in the CFMODE register equal 001 or 100). When VARACC[1:0] = 00, the default value, the reactive powers are sign accumulated before entering the energy-to-frequency converter. Figure 75 shows how signed reactive power accumulation works. In this mode, the CFx pulses synchronize perfectly with the reactive energy accumu REVRPx BIT IN STATUS0 xVARSIGN BIT IN PHSIGN VARNOLOAD SIGN = POSITIVE POS NEG POS NEG 08510-153 POS 08510-053 APNOLOAD SIGN = POSITIVE REACTIVE POWER Figure 75. Reactive Power Signed Accumulation Mode When VARACC[1:0] = 10, the reactive powers are accumulated depending on the sign of the corresponding active power. If the active power is positive, the reactive power is accumulated as is. If the active power is negative, the sign of the reactive power is changed for accumulation. Figure 76 shows how the sign adjusted reactive power accumulation mode works. In this mode, the xVARHR registers continue to accumulate reactive powers in signed mode, even if the CFx pulses are generated based on the sign adjusted accumulation mode. Rev. E | Page 60 of 96 ADE7854/ADE7858/ADE7868/ADE7878 status bit is cleared, and the IRQ0 pin is set high again by writing to the STATUS0 register with the corresponding bit set to 1. REACTIVE ENERGY NO LOAD CONDITION The no load condition is defined in metering equipment standards as occurring when the voltage is applied to the meter and no current flows in the current circuit. To eliminate any creep effects in the meter, the ADE7854/ADE7858/ADE7868/ADE7878 contain three separate no load detection circuits: one related to the total active and reactive powers (ADE7858/ADE7868/ADE7878 only), one related to the fundamental active and reactive powers (ADE7878 only), and one related to the apparent powers. NO-LOAD THRESHOLD REACTIVE POWER NO-LOAD THRESHOLD NO-LOAD THRESHOLD ACTIVE POWER No Load Detection Based On Total Active, Reactive Powers REVRPx BIT IN STATUS0 VARNOLOAD SIGN = POSITIVE POS NEG POS 08510-155 xVARSIGN BIT IN PHSIGN Figure 76. Reactive Power Accumulation in Sign Adjusted Mode Sign of Sum-of-Phase Powers in the CFx Datapath The ADE7854/ADE7858/ADE7868/ADE7878 have sign detection circuitry for the sum of phase powers that are used in the CFx datapath. As seen in the beginning of the Energy-to-Frequency Conversion section, the energy accumulation in the CFx datapath is executed in two stages. Every time a sign change is detected in the energy accumulation at the end of the first stage, that is, after the energy accumulated into the accumulator reaches one of the WTHR, VARTHR, or VATHR thresholds, a dedicated interrupt can be triggered synchronously with the corresponding CFx pulse. The sign of each sum can be read in the PHSIGN register. Bit 18, Bit 13, and Bit 9 (REVPSUM3, REVPSUM2, and REVPSUM1, respectively) of the STATUS0 register are set to 1 when a sign change of the sum of powers in CF3, CF2, or CF1 datapaths occurs. To correlate these events with the pulses generated at the CFx pins, after a sign change occurs, Bit REVPSUM3, Bit REVPSUM2, and Bit REVPSUM1 are set in the same moment in which a high-to-low transition at the CF3, CF2, and CF1 pin, respectively, occurs. Bit 8, Bit 7, and Bit 3 (SUM3SIGN, SUM2SIGN, and SUM1SIGN, respectively) of the PHSIGN register are set in the same moment with Bit REVPSUM3, Bit REVPSUM2, and Bit EVPSUM1 and indicate the sign of the sum of phase powers. When cleared to 0, the sum is positive. When set to 1, the sum is negative. Interrupts attached to Bit 18, Bit 13, and Bit 9 (REVPSUM3, REVPSUM2, and REVPSUM1, respectively) in the STATUS0 register are enabled by setting Bit 18, Bit 13, and Bit 9 in the MASK0 register. If enabled, the IRQ0 pin is set low, and the status bit is set to 1 whenever a change of sign occurs. To find the phase that triggered the interrupt, the PHSIGN register is read immediately after reading the STATUS0 register. Next, the This no load condition is triggered when the absolute values of both phase total active and reactive powers are less than or equal to positive thresholds indicated in the respective APNOLOAD and VARNOLOAD signed 24-bit registers. In this case, the total active and reactive energies of that phase are not accumulated and no CFx pulses are generated based on these energies. The APNOLOAD register represents the positive no load level of active power relative to PMAX, the maximum active power obtained when full-scale voltages and currents are provided at ADC inputs. The VARNOLOAD register represents the positive no load level of reactive power relative to PMAX. The expression used to compute APNOLOAD signed 24-bit value is APNOLOAD = U n I NOLOAD x x PMAX U FS I FS (47) where: PMAX = 33,516,139 = 0x1FF6A6B, the instantaneous power computed when the ADC inputs are at full scale. UFS, IFS are the rms values of phase voltages and currents when the ADC inputs are at full scale. Un is the nominal rms value of phase voltage. INOLOAD is the minimum rms value of phase current the meter starts measuring. The VARNOLOAD register usually contains the same value as the APNOLOAD register. When APNOLOAD and VARNOLOAD are set to negative values, the no load detection circuit is disabled. Note that the ADE7854 measures only the total active powers. To ensure good functionality of the ADE7854 no-load circuit, set the VARNOLOAD register at 0x800000. As previously stated in the Current Waveform Gain Registers section, the serial ports of the ADE78xx work on 32-, 16-, or 8-bit words and the DSP works on 28 bits. APNOLOAD and VARNOLOAD 24-bit signed registers are accessed as 32-bit registers with the four MSBs padded with 0s and sign extended to 28 bits. See Figure 33 for details. Rev. E | Page 61 of 96 ADE7854/ADE7858/ADE7868/ADE7878 Bit 0 (NLOAD) in the STATUS1 register is set when this no load condition in one of the three phases is triggered. Bits[2:0] (NLPHASE[2:0]) in the PHNOLOAD register indicate the state of all phases relative to a no load condition and are set simultaneously with Bit NLOAD in the STATUS1 register. NLPHASE[0] indicates the state of Phase A, NLPHASE[1] indicates the state of Phase B, and NLPHASE[2] indicates the state of Phase C. When Bit NLPHASE[x] is cleared to 0, it means the phase is out of a no load condition. When set to 1, it means the phase is in a no load condition. An interrupt attached to Bit 0 (NLOAD) in the STATUS1 register can be enabled by setting Bit 0 in the MASK1 register. If enabled, the IRQ1 pin is set to low, and the status bit is set to 1 whenever one of three phases enters or exits this no load condition. To find the phase that triggered the interrupt, the PHNOLOAD register is read immediately after reading the STATUS1 register. Next, the status bit is cleared, and the IRQ1 pin is set to high by writing to the STATUS1 register with the corresponding bit set to 1. No Load Detection Based on Fundamental Active and Reactive Powers--ADE7878 Only This no load condition (available on the ADE7878 only) is triggered when the absolute values of both phase fundamental active and reactive powers are less than or equal to the respective APNOLOAD and VARNOLOAD positive thresholds. In this case, the fundamental active and reactive energies of that phase are not accumulated, and no CFx pulses are generated based on these energies. APNOLOAD and VARNOLOAD are the same no load thresholds set for the total active and reactive powers. When APNOLOAD and VARNOLOAD are set to negative values, this no load detection circuit is disabled. Bit 1 (FNLOAD) in the STATUS1 register is set when this no load condition in one of the three phases is triggered. Bits[5:3] (FNLPHASE[2:0]) in the PHNOLOAD register indicate the state of all phases relative to a no load condition and are set simultaneously with Bit FNLOAD in the STATUS1 register. FNLPHASE[0] indicates the state of Phase A, FNLPHASE[1] indicates the state of Phase B, and FNLPHASE[2] indicates the state of Phase C. When Bit FNLPHASE[x] is cleared to 0, it means the phase is out of the no load condition. When set to 1, it means the phase is in a no load condition. An interrupt attached to the Bit 1 (FNLOAD) in the STATUS1 register can be enabled by setting Bit 1 in the MASK1 register. If enabled, the IRQ1 pin is set low and the status bit is set to 1 whenever one of three phases enters or exits this no load condition. To find the phase that triggered the interrupt, the PHNOLOAD register is read immediately after reading the STATUS1 register. Then the status bit is cleared and the IRQ1 pin is set back high by writing to the STATUS1 register with the corresponding bit set to 1. No Load Detection Based on Apparent Power This no load condition is triggered when the absolute value of phase apparent power is less than or equal to the threshold indicated in the VANOLOAD 24-bit signed register. In this case, the apparent energy of that phase is not accumulated and no CFx pulses are generated based on this energy. The VANOLOAD register represents the positive no load level of apparent power relative to PMAX, the maximum apparent power obtained when full-scale voltages and currents are provided at the ADC inputs. The expression used to compute the VANOLOAD signed 24-bit value is VANOLOAD = U n I NOLOAD x x PMAX U FS I FS (48) where: PMAX = 33,516,139 = 0x1FF6A6B, the instantaneous apparent power computed when the ADC inputs are at full scale. UFS, IFS are the rms values of phase voltages and currents when the ADC inputs are at full scale. Un is the nominal rms value of phase voltage. INOLOAD is the minimum rms value of phase current the meter starts measuring. When the VANOLOAD register is set to negative values, the no load detection circuit is disabled. As stated in the Current Waveform Gain Registers section, the serial ports of the ADE7854/ADE7858/ADE7868/ADE7878 work on 32-, 16-, or 8-bit words and the DSP works on 28 bits. Similar to the registers presented in Figure 33, the VANOLOAD 24-bit signed register is accessed as a 32-bit register with the four MSBs padded with 0s and sign extended to 28 bits. Bit 2 (VANLOAD) in the STATUS1 register is set when this no load condition in one of the three phases is triggered. Bits[8:6] (VANLPHASE[2:0]) in the PHNOLOAD register indicate the state of all phases relative to a no load condition and they are set simultaneously with Bit VANLOAD in the STATUS1 register: * * * Bit VANLPHASE[0] indicates the state of Phase A. Bit VANLPHASE[1] indicates the state of Phase B. Bit VANLPHASE[2] indicates the state of Phase C. When Bit VANLPHASE[x] is cleared to 0, it means the phase is out of no load condition. When set to 1, it means the phase is in no load condition. An interrupt attached to Bit 2 (VANLOAD) in the STATUS1 register is enabled by setting Bit 2 in the MASK1 register. If enabled, the IRQ1 pin is set low and the status bit is set to 1 whenever one of three phases enters or exits this no load condition. To find the phase that triggered the interrupt, the PHNOLOAD register is read immediately after reading the STATUS1 register. Next, the status bit is cleared, and the IRQ1 pin is set to high by writing to the STATUS1 register with the corresponding bit set to 1. Rev. E | Page 62 of 96 ADE7854/ADE7858/ADE7868/ADE7878 bi(0) = 1, i = 0, 1, 2, ..., 31, the initial state of the bits that form the CRC. Bit b0 is the least significant bit, and Bit b31 is the most significant. CHECKSUM REGISTER The ADE7854/ADE7858/ADE7868/ADE7878 have a checksum 32-bit register, CHECKSUM, that ensures certain very important configuration registers maintain their desired value during Normal Power Mode PSM0. gi, i = 0, 1, 2, ..., 31 are the coefficients of the generating polynomial defined by the IEEE802.3 standard as follows: G(x) = x32 + x26 + x23 + x22 + x16 + x12 + x11 + x10 + x8 + x7 + x5 + x4 + x2 + x + 1 (49) The registers covered by this register are MASK0, MASK1, COMPMODE, gain, CFMODE, CF1DEN, CF2DEN, CF3DEN, CONFIG, MMODE, ACCMODE, LCYCMODE, HSDC_CFG, and another six 8-bit reserved internal registers that always have default values. The ADE78xx computes the cyclic redundancy check (CRC) based on the IEEE802.3 standard. The registers are introduced one-by-one into a linear feedback shift register (LFSR) based generator starting with the least significant bit (as shown in Figure 77). The 32-bit result is written in the CHECKSUM register. After power-up or a hardware/software reset, the CRC is computed on the default values of the registers giving the results presented in the Table 23. g0 = g1 = g2 = g4 = g5 = g7 = 1 g8 = g10 = g11 = g12 = g16 = g22 = g26 = g31 = 1 All of the other gi coefficients are equal to 0. CRC of Internal Registers 0x3A7ABC72 0x3E7D0FC1 0x23F7C7B1 0x2D32A389 0 15 0 15 0 15 7 0 255 248 240 232 224 0 7 INTERNAL REGISTER 216 (52) bi(j) = FB(j) AND gi XOR bi - 1(j - 1), i = 1, 2, 3, ..., 31 (53) 0 INTERNAL REGISTER 40 32 7 0 INTERNAL REGISTER 7 0 INTERNAL REGISTER 24 7 0 INTERNAL REGISTER 16 8 7 Figure 77. CHECKSUM Register Calculation g0 g1 g2 g3 g31 FB b0 b1 b2 b31 LFSR a255, a254,....,a2, a1, a0 Figure 78. LFSR Generator Used in CHECKSUM Register Calculation Rev. E | Page 63 of 96 0 INTERNAL REGISTER 7 LFSR GENERATOR 08510-056 0 31 MASK0 MASK1 COMPMODE GAIN CFMODE b0(j) = FB(j) AND g0 Two different approaches can be followed in using the CHECKSUM register. One is to compute the CRC based on the relations (47) to (51) and then compare the value against the CHECKSUM register. Another is to periodically read the CHECKSUM register. If two consecutive readings differ, it can be assumed that one of the registers has changed value and therefore, the ADE7854, ADE7858, ADE7868, or ADE7878 has changed configuration. The recommended response is to initiate a hardware/software reset that sets the values of all registers to the default, including the reserved ones, and then reinitialize the configuration registers. Figure 78 shows how the LFSR works. The MASK0, MASK1, COMPMODE, gain, CFMODE, CF1DEN, CF2DEN, CF3DEN, CONFIG, MMODE, ACCMODE, LCYCMODE, and HSDC_CFG registers, and the six 8-bit reserved internal registers form the bits [a255, a254,..., a0] used by LFSR. Bit a0 is the least significant bit of the first internal register to enter LFSR; Bit a255 is the most significant bit of the MASK0 register, the last register to enter LFSR. The formulas that govern LFSR are as follows: 31 (51) 0 08510-055 Default Value of CHECKSUM 0x2689B124 0xD6744F93 0x93D774E6 0x33666787 FB(j) = aj - 1 XOR b31(j - 1) Equation 51, Equation 52, and Equation 53 must be repeated for j = 1, 2, ..., 256. The value written into the CHECKSUM register contains the Bit bi(256), i = 0, 1, ..., 31. The value of the CRC, after the bits from the reserved internal register have passed through LFSR, is obtained at Step j = 48 and is presented in the Table 23. Table 23. Default Values of CHECKSUM and of Internal Registers CRC Part No. ADE7854 ADE7858 ADE7868 ADE7878 (50) ADE7854/ADE7858/ADE7868/ADE7878 INTERRUPTS The ADE7854/ADE7858/ADE7868/ADE7878 have two interrupt pins, IRQ0 and IRQ1. Each of the pins is managed by a 32-bit interrupt mask register, MASK0 and MASK1, respectively. To enable an interrupt, a bit in the MASKx register must be set to 1. To disable it, the bit must be cleared to 0. Two 32-bit status registers, STATUS0 and STATUS1, are associated with the interrupts. When an interrupt event occurs in the ADE78xx, the corresponding flag in the interrupt status register is set to a Logic 1 (see Table 37 and Table 38). If the mask bit for this interrupt in the interrupt mask register is Logic 1, then the IRQx logic output goes active low. The flag bits in the interrupt status register are set irrespective of the state of the mask bits. To determine the source of the interrupt, the MCU should perform a read of the corresponding STATUSx register and identify which bit is set to 1. To erase the flag in the status register, write back to the STATUSx register with the flag set to 1. After an interrupt pin goes low, the status register is read and the source of the interrupt is identified. Then, the status register is written back without any change to clear the status flag to 0. The IRQx pin remains low until the status flag is cancelled. By default, all interrupts are disabled. However, the RSTDONE interrupt is an exception. This interrupt can never be masked (disabled) and, therefore, Bit 15 (RSTDONE) in the MASK1 register does not have any functionality. The IRQ1 pin always goes low, and Bit 15 (RSTDONE) in the STATUS1 register is set to 1 whenever a power-up or a hardware/software reset process ends. To cancel the status flag, the STATUS1 register has to be written with Bit 15 (RSTDONE) set to 1. Certain interrupts are used in conjunction with other status registers. The following bits in the MASK1 register work in conjunction with the status bits in the PHNOLOAD register: * * * Bit 16, (SAG) Bit 17 (OI) Bit 18 (OV) The following bits in the MASK1 register work with the status bits in the IPEAK and VPEAK registers, respectively: * * Bit 23 (PKI) Bit 24 (PKV) When the STATUSx register is read and one of these bits is set to 1, the status register associated with the bit is immediately read to identify the phase that triggered the interrupt and only at that time can the STATUSx register be written back with the bit set to 1. Using the Interrupts with an MCU Figure 79 shows a timing diagram that illustrates a suggested implementation of the ADE7854/ADE7858/ADE7868/ADE7878 interrupt management using an MCU. At Time t1, the IRQx pin goes active low indicating that one or more interrupt events have occurred in the ADE78xx, at which point the following steps should be taken: 1. 2. 3. 4. 5. Bit 0 (NLOAD) Bit1 (FNLOAD), available in the ADE7878 only Bit 2 (VANLOAD) The following bits in the MASK1 register work with the status bits in the PHSTATUS register: * * * The following bits in the MASK0 register work with the status bits in the PHSIGN register: * Bits[6:8] (REVAPx) * Bits[10:12] (REVRPx), available in the ADE7858, ADE7868, and ADE7878 only * Bit 9, Bit 13, and Bit 18 (REVPSUMx) Tie the IRQx pin to a negative-edge-triggered external interrupt on the MCU. On detection of the negative edge, configure the MCU to start executing its interrupt service routine (ISR). On entering the ISR, disable all interrupts using the global interrupt mask bit. At this point, the MCU external interrupt flag can be cleared to capture interrupt events that occur during the current ISR. When the MCU interrupt flag is cleared, a read from STATUSx, the interrupt status register, is carried out. The interrupt status register content is used to determine the source of the interrupt(s) and, hence, the appropriate action to be taken. The same STATUSx content is written back into the ADE78xx to clear the status flag(s) and reset the IRQx line to logic high (t2). If a subsequent interrupt event occurs during the ISR (t3), that event is recorded by the MCU external interrupt flag being set again. On returning from the ISR, the global interrupt mask bit is cleared (same instruction cycle) and the external interrupt flag uses the MCU to jump to its ISR once again. This ensures that the MCU does not miss any external interrupts. Figure 80 shows a recommended timing diagram when the status bits in the STATUSx registers work in conjunction with bits in other registers. When the IRQx pin goes active low, the STATUSx register is read, and if one of these bits is 1, a second Rev. E | Page 64 of 96 ADE7854/ADE7858/ADE7868/ADE7878 t1 t2 t3 MCU INTERRUPT FLAG SET PROGRAM SEQUENCE GLOBAL INTERRUPT MASK JUMP TO ISR CLEAR MCU INTERRUPT FLAG READ STATUSx WRITE BACK STATUSx ISR ACTION (BASED ON STATUSx CONTENTS) ISR RETURN GLOBAL INTERRUPT MASK RESET JUMP TO ISR 08510-057 IRQx Figure 79. Interrupt Management t1 t2 t3 MCU INTERRUPT FLAG SET PROGRAM SEQUENCE JUMP TO ISR GLOBAL INTERRUPT MASK CLEAR MCU INTERRUPT FLAG READ STATUSx READ PHx WRITE BACK STATUSx ISR ACTION (BASED ON STATUSx CONTENTS) ISR RETURN GLOBAL INTERRUPT MASK RESET JUMP TO ISR 08510-058 IRQx Figure 80. Interrupt Management when PHSTATUS, IPEAK, VPEAK, or PHSIGN Registers are Involved status register is read immediately to identify the phase that triggered the interrupt. The name, PHx, in Figure 80 denotes one of the PHSTATUS, IPEAK, VPEAK, or PHSIGN registers. Then, STATUSx is written back to clear the status flag(s). SERIAL INTERFACES The ADE7854/ADE7858/ADE7868/ADE7878 have three serial port interfaces: one fully licensed I2C interface, one serial peripheral interface (SPI), and one high speed data capture port (HSDC). As the SPI pins are multiplexed with some of the pins of the I2C and HSDC ports, the ADE78xx accepts two configurations: one using the SPI port only and one using the I2C port in conjunction with the HSDC port. Serial Interface Choice After reset, the HSDC port is always disabled. Choose between the I2C and SPI ports by manipulating the SS/HSA pin after power-up or after a hardware reset. If the SS/HSA pin is kept high, then the ADE7854/ADE7858/ADE7868/ADE7878 use the I2C port until a new hardware reset is executed. If the SS/HSA pin is toggled high to low three times after power-up or after a hardware reset, the ADE7854/ADE7858/ADE7868/ADE7878 use the SPI port until a new hardware reset is executed. This manipulation of the SS/HSA pin can be accomplished in two ways. First, use the SS/HSA pin of the master device (that is, the microcontroller) as a regular I/O pin and toggle it three times. Second, execute three SPI write operations to a location in the address space that is not allocated to a specific ADE78xx register (for example 0xEBFF, where eight bit writes can be executed). These writes allow the SS/HSA pin to toggle three times. See the SPI Write Operation section for details on the write protocol involved. After the serial port choice is completed, it needs to be locked. Consequently, the active port remains in use until a hardware reset is executed in PSM0 normal mode or until a power-down. If I2C is the active serial port, Bit 1 (I2C_LOCK) of the CONFIG2 register must be set to 1 to lock it in. From this moment, the ADE7854/ADE7858/ADE7868/ADE7878 ignore spurious toggling of the SS pin and an eventual switch into using the SPI port is no longer possible. If the SPI is the active serial port, any write to the CONFIG2 register locks the port. From this moment, a switch into using the I2C port is no longer possible. Once locked, the serial port choice is maintained when the ADE78xx changes PSMx power modes. The functionality of the ADE78xx is accessible via several onchip registers. The contents of these registers can be updated or read using either the I2C or SPI interfaces. The HSDC port provides the state of up to 16 registers representing instantaneous values of phase voltages and neutral currents, and active, reactive, and apparent powers. I2C-Compatible Interface The ADE7854/ADE7858/ADE7868/ADE7878 supports a fully licensed I2C interface. The I2C interface is implemented as a full hardware slave. SDA is the data I/O pin, and SCL is the serial clock. These two pins are shared with the MOSI and SCLK pins of the on-chip SPI interface. The maximum serial clock frequency supported by this interface is 400 kHz. The two pins used for data transfer, SDA and SCL, are configured in a wire-AND'ed format that allows arbitration in a multimaster system. The transfer sequence of an I2C system consists of a master device initiating a transfer by generating a start condition while the bus is idle. The master transmits the address of the slave device and the direction of the data transfer in the initial address transfer. If the slave acknowledges, the data transfer is initiated. This continues until the master issues a stop condition, and the bus becomes idle. Rev. E | Page 65 of 96 ADE7854/ADE7858/ADE7868/ADE7878 I2C Write Operation The write operation using the I2C interface of the ADE7854/ ADE7858/ADE7868/ADE7878 initiate when the master generates a start condition and consists in one byte representing the address of the ADE78xx followed by the 16-bit address of the target register and by the value of the register. 15 8 7 0 31 16 15 8 7 0 7 0 S 0 1 1 1 0 0 0 0 SLAVE ADDRESS S MS 8 BITS OF LS 8 BITS OF A A A C REGISTER ADDRESS C REGISTER ADDRESS C K K K BYTE 3 (MS) OF REGISTER A A A C BYTE 2 OF REGISTER C BYTE 1 OF REGISTER C K K K ACKNOWLEDGE GENERATED BY ADE78xx Figure 81. I2C Write Operation of a 32-Bit Register Rev. E | Page 66 of 96 BYTE 0 (LS) OF REGISTER A C K 08510-059 START The most significant seven bits of the address byte constitute the address of the ADE7854/ADE7858/ADE7868/ADE7878 and they are equal to 0111000b. Bit 0 of the address byte is a STOP read/write bit. Because this is a write operation, it has to be cleared to 0; therefore, the first byte of the write operation is 0x70. After every byte is received, the ADE7854/ADE7858/ ADE7868/ADE7878 generate an acknowledge. As registers can have 8, 16, or 32 bits, after the last bit of the register is transmitted and the ADE78xx acknowledges the transfer, the master generates a stop condition. The addresses and the register content are sent with the most significant bit first. See Figure 81 for details of the I2C write operation. ADE7854/ADE7858/ADE7868/ADE7878 I2C Read Operation ADE7854/ADE7858/ADE7868/ADE7878, the second stage begins with the master generating a new start condition followed by an address byte. The most significant seven bits of this address byte constitute the address of the ADE78xx, and they are equal to 0111000b. Bit 0 of the address byte is a read/write bit. Because this is a read operation, it must be set to 1; thus, the first byte of the read operation is 0x71. After this byte is received, the ADE78xx generates an acknowledge. Then, the ADE78xx sends the value of the register, and after every eight bits are received, the master generates an acknowledge. All the bytes are sent with the most significant bit first. Because registers can have 8, 16, or 32 bits, after the last bit of the register is received, the master does not acknowledge the transfer but generates a stop condition. The read operation using the I2C interface of the ADE7854/ ADE7858/ADE7868/ADE7878 is accomplished in two stages. The first stage sets the pointer to the address of the register. The second stage reads the content of the register. START As seen in Figure 82, the first stage initiates when the master generates a start condition and consists in one byte representing the address of the ADE7854/ADE7858/ADE7868/ADE7878 followed by the 16-bit address of the target register. The ADE78xx acknowledges every byte received. The address byte is similar to the address byte of a write operation and is equal to 0x70 (see the I2C Write Operation section for details). After the last byte of the register address has been sent and acknowledged by the 15 8 7 0 S 0 1 1 1 0 0 0 0 A MSB 8 BITS OF C REGISTER ADDRESS K SLAVE ADDRESS A LSB 8 BITS OF C REGISTER ADDRESS K A C K START ACKNOWLEDGE GENERATED BY MASTER 0 1 1 1 0 0 A 0 C K 7 7 0 1 SLAVE ADDRESS S A C K BYTE 3 (MSB) OF REGISTER BYTE 2 OF REGISTER BYTE 1 OF REGISTER BYTE 0 (LSB) OF REGISTER 08510-060 S A 8 C K A 16 C 15 K 31 N O A C 0 K STOP ACKNOWLEDGE GENERATED BY ADE78xx ACKNOWLEDGE GENERATED BY ADE78xx Figure 82. I2C Read Operation of a 32-Bit Register Rev. E | Page 67 of 96 ADE7854/ADE7858/ADE7868/ADE7878 SPI-Compatible Interface The SS logic input is the chip select input. This input is used when multiple devices share the serial bus. Drive the SS input low for the entire data transfer operation. Bringing SS high during a data transfer operation aborts the transfer and places the serial bus in a high impedance state. A new transfer can then be initiated by returning the SS logic input to low. However, because aborting a data transfer before completion leaves the accessed register in a state that cannot be guaranteed, every time a register is written, its value should be verified by reading it back. The protocol is similar to the protocol used in I2C interface. SPI DEVICE ADE78xx MOSI/SDA MOSI MISO/HSD MISO SCLK/SCL SCK SS/HSA Figure 83. Connecting ADE78xx SPI with an SPI Device SPI Read Operation The read operation using the SPI interface of the ADE7854/ ADE7858/ADE7868/ADE7878 initiate when the master sets the SS/HSA pin low and begins sending one byte, representing the address of the ADE7854/ADE7858/ADE7868/ADE7878, on the MOSI line. The master sets data on the MOSI line starting with the first high-to-low transition of SCLK. The SPI of the ADE78xx samples data on the low-to-high transitions of SCLK. The most significant seven bits of the address byte can have any value, but as a good programming practice, they should be different from 0111000b, the seven bits used in the I2C protocol. Bit 0 (read/write) of the address byte must be 1 for a read operation. Next, the master sends the 16-bit address of the register that is read. After the ADE78xx receives the last bit of address of the register on a low-to-high transition of SCLK, it begins to transmit its contents on the MISO line when the next SCLK high-to-low transition occurs; thus, the master can sample the data on a low-to-high SCLK transition. After the master receives the last bit, it sets the SS and SCLK lines high and the communication ends. The data lines, MOSI and MISO, go into a high impedance state. See Figure 84 for details of the SPI read operation. SS SCLK 15 14 0 0 0 0 0 0 0 1 1 0 REGISTER ADDRESS 31 30 MISO 1 0 REGISTER VALUE Figure 84. SPI Read Operation of a 32-Bit Register Rev. E | Page 68 of 96 08510-062 MOSI SS 08510-061 The SPI of the ADE7854/ADE7858/ADE7868/ADE7878 is always a slave of the communication and consists of four pins (with dual functions): SCLK/SCL, MOSI/SDA, MISO/HSD, and SS/HSA. The functions used in the SPI-compatible interface are SCLK, MOSI, MISO, and SS. The serial clock for a data transfer is applied at the SCLK logic input. This logic input has a Schmitt trigger input structure that allows the use of slow rising (and falling) clock edges. All data transfer operations synchronize to the serial clock. Data shifts into the ADE78xx at the MOSI logic input on the falling edge of SCLK and the ADE78xx samples it on the rising edge of SCLK. Data shifts out of the ADE7854/ ADE7858/ADE7868/ADE7878 at the MISO logic output on a falling edge of SCLK and can be sampled by the master device on the raising edge of SCLK. The most significant bit of the word is shifted in and out first. The maximum serial clock frequency supported by this interface is 2.5 MHz. MISO stays in high impedance when no data is transmitted from the ADE7854/ADE7858/ADE7868/ADE7878. See Figure 83 for details of the connection between the ADE78xx SPI and a master device containing an SPI interface. ADE7854/ADE7858/ADE7868/ADE7878 SPI Write Operation The write operation using the SPI interface of the ADE78xx initiates when the master sets the SS/HSA pin low and begins sending one byte representing the address of the ADE7854/ ADE7858/ADE7868/ADE7878 on the MOSI line. The master sets data on the MOSI line starting with the first high-to-low transition of SCLK. The SPI of the ADE78xx samples data on the low-to-high transitions of SCLK. The most significant seven bits of the address byte can have any value, but as a good programming practice, they should be different from 0111000b, the seven bits used in the I2C protocol. Bit 0 (read/write) of the address byte must be 0 for a write operation. Next, the master sends both the 16-bit address of the register that is written and the 32-, 16-, or 8-bit value of that register without losing any SCLK cycle. After the last bit is transmitted, the master sets the SS and SCLK lines high at the end of the SCLK cycle and the communication ends. The data lines, MOSI and MISO, go into a high impedance state. See Figure 85 for details of the SPI write operation. SS SCLK MOSI 0 0 0 0 0 0 0 0 1 0 31 30 REGISTER ADDRESS REGISTER VALUE Figure 85. SPI Write Operation of a 32-Bit Register Rev. E | Page 69 of 96 1 0 08510-063 15 14 ADE7854/ADE7858/ADE7868/ADE7878 HSDC Interface The high speed data capture (HSDC) interface is disabled after default. It can be used only if the ADE7854/ADE7858/ADE7868/ ADE7878 is configured with an I2C interface. The SPI interface of the ADE7854/ADE7858/ADE7868/ADE7878 cannot be used simultaneously with HSDC. Bit 6 (HSDCEN) in the CONFIG register activates HSDC when set to 1. If Bit HSDCEN is cleared to 0, the default value, the HSDC interface is disabled. Setting Bit HSDCEN to 1 when SPI is in use does not have any effect. HSDC is an interface for sending to an external device (usually a microprocessor or a DSP) up to sixteen 32-bit words. The words represent the instantaneous values of the phase currents and voltages, neutral current, and active, reactive, and apparent powers. The registers being transmitted include IAWV, VAWV, IBWV, VBWV, ICWV, VCWV, AVA, INWV, BVA, CVA, AWATT, BWATT, CWATT, AVAR, BVAR, and CVAR. All are 24-bit registers that are sign extended to 32-bits (see Figure 35 for details). In the case of ADE7854 and ADE7858, the INWV register is not available. In its place, the HSDC transmits one 32-bit word always equal to 0. In addition, the AVAR, BVAR, and CVAR registers are not available in the ADE7854. In their place, the HSDC transmits three 32-bit words that are always equal to 0. HSDC can be interfaced with SPI or similar interfaces. HSDC is always a master of the communication and consists of three pins: HSA, HSD, and HSCLK. HSA represents the select signal. It stays active low or high when a word is transmitted and it is usually connected to the select pin of the slave. HSD sends data to the slave and it is usually connected to the data input pin of the slave. HSCLK is the serial clock line that is generated by the ADE7854/ADE7858/ADE7868/ADE7878 and it is usually connected to the serial clock input of the slave. Figure 86 shows the connections between the ADE78xx HSDC and slave devices containing an SPI interface. MISO/HSD CF3/HSCLK SS/HSA SPI DEVICE MISO SCK SS 08510-064 ADE78xx Figure 86. Connecting the ADE78xx HSDC with an SPI The HSDC communication is managed by the HSDC_CFG register (see Table 53). It is recommended to set the HSDC_CFG register to the desired value before enabling the port using Bit 6 (HSDCEN) in the CONFIG register. In this way, the state of various pins belonging to the HSDC port do not take levels inconsistent with the desired HSDC behavior. After a hardware reset or after power-up, the MISO/HSD and SS/HSA pins are set high. Bit 0 (HCLK) in the HSDC_CFG register determines the serial clock frequency of the HSDC communication. When HCLK is 0 (the default value), the clock frequency is 8 MHz. When HCLK is 1, the clock frequency is 4 MHz. A bit of data is transmitted for every HSCLK high-to-low transition. The slave device that receives data from HSDC samples the HSD line on the low-tohigh transition of HSCLK. The words can be transmitted as 32-bit packages or as 8-bit packages. When Bit 1 (HSIZE) in the HSDC_CFG register is 0 (the default value), the words are transmitted as 32-bit packages. When Bit HSIZE is 1, the registers are transmitted as 8-bit packages. The HSDC interface transmits the words MSB first. Bit 2 (HGAP) introduces a gap of seven HSCLK cycles between packages when Bit 2 (HGAP) is set to 1. When Bit HGAP is cleared to 0 (the default value), no gap is introduced between packages and the communication time is shortest. In this case, HSIZE does not have any influence on the communication and a data bit is placed on the HSD line with every HSCLK high-to-low transition. Bits[4:3] (HXFER[1:0]) decide how many words are transmitted. When HXFER[1:0] is 00, the default value, then all 16 words are transmitted. When HXFER[1:0] is 01, only the words representing the instantaneous values of phase and neutral currents and phase voltages are transmitted in the following order: IAWV, VAWV, IBWV, VBWV, ICWV, VCWV, and one 32-bit word that is always equal to INWV. When HXFER[1:0] is 10, only the instantaneous values of phase powers are transmitted in the following order: AVA, BVA, CVA, AWATT, BWATT, CWATT, AVAR, BVAR, and CVAR. The value, 11, for HXFER[1:0] is reserved and writing it is equivalent to writing 00, the default value. Bit 5 (HSAPOL) determines the polarity of HSA function of the SS/HSA pin during communication. When HSAPOL is 0 (the default value), HSA is active low during the communication. This means that HSA stays high when no communication is in progress. When the communication starts, HSA goes low and stays low until the communication ends. Then it goes back to high. When HSAPOL is 1, the HSA function of the SS/HSA pin is active high during the communication. This means that HSA stays low when no communication is in progress. When the communication starts, HSA goes high and stays high until the communication ends; then, it goes back to low. Bits[7:6] of the HSDC_CFG register are reserved. Any value written into these bits does not have any consequence on HSDC behavior. Figure 87 shows the HSDC transfer protocol for HGAP = 0, HXFER[1:0] = 00 and HSAPOL = 0. Note that the HSDC interface sets a data bit on the HSD line every HSCLK highto-low transition and the value of Bit HSIZE is irrelevant. Rev. E | Page 70 of 96 ADE7854/ADE7858/ADE7868/ADE7878 Figure 88 shows the HSDC transfer protocol for HSIZE = 0, HGAP = 1, HXFER[1:0] = 00, and HSAPOL = 0. Note that the HSDC interface introduces a seven-HSCLK cycles gap between every 32-bit word. Table 24 lists the time it takes to execute an HSDC data transfer for all HSDC_CFG register settings. For some settings, the transfer time is less than 125 s (8 kHz), the waveform sample registers update rate. This means the HSDC port transmits data every sampling cycle. For settings in which the transfer time is greater than 125 s, the HSDC port transmits data only in the first of two consecutive 8 kHz sampling cycles. This means it transmits registers at an effective rate of 4 kHz. Figure 89 shows the HSDC transfer protocol for HSIZE = 1, HGAP = 1, HXFER[1:0] = 00, and HSAPOL = 0. Note that the HSDC interface introduces a seven-HSCLK cycles gap between every 8-bit word. See Table 53 for the HSDC_CFG register and descriptions for the HCLK, HSIZE, HGAP, HXFER[1:0], and HSAPOL bits. Table 24. Communication Times for Various HSDC Settings HXFER[1:0] 00 00 00 00 00 00 01 01 01 01 01 01 10 10 10 10 10 10 HCLK 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 Communication Time (s) 64 128 77.125 154.25 119.25 238.25 28 56 33.25 66.5 51.625 103.25 36 72 43 86 66.625 133.25 N/A means not applicable. HSCLK 31 HSD 0 31 IAVW (32 BITS) 0 31 VAWV (32 BITS) 31 0 IBWV (32 BITS) 0 CVAR (32 BITS) 08510-066 HSA Figure 87. HSDC Communication for HGAP = 0, HXFER[1:0] = 00, and HSAPOL = 0; HSIZE Is Irrelevant HSCLK 31 HSDATA 31 0 IAVW (32 BITS) 31 0 VAWV (32 BITS) 7 HCLK CYCLES 0 IBWV (32 BITS) 31 0 CVAR (32 BITS) 7 HCLK CYCLES 08510-067 1 HSIZE 1 N/A N/A 0 0 1 1 N/A N/A 0 0 1 1 N/A N/A 0 0 1 1 HGAP 0 0 1 1 1 1 0 0 1 1 1 1 0 0 1 1 1 1 HSACTIVE Figure 88. HSDC Communication for HSIZE = 0, HGAP = 1, HXFER[1:0] = 00, and HSAPOL = 0 Rev. E | Page 71 of 96 ADE7854/ADE7858/ADE7868/ADE7878 HSCLK 31 HSDATA 23 24 IAVW (BYTE 3) 15 16 IAWV (BYTE 2) 7 0 CVAR (BYTE 0) 7 HCLK CYCLES 08510-068 7 HCLK CYCLES 8 IAWV (BYTE 1) HSACTIVE Figure 89. HSDC Communication for HSIZE = 1, HGAP = 1, HXFER[1:0] = 00, and HSAPOL = 0 ADE7878 EVALUATION BOARD DIE VERSION An evaluation board built upon the ADE7878 configuration supports all ADE7854, ADE7858, ADE7868, and ADE7878 components. Visit www.analog.com/ADE7878 for details. The register named version identifies the version of the die. It is an 8-bit, read-only version register located at Address 0xE707. Rev. E | Page 72 of 96 ADE7854/ADE7858/ADE7868/ADE7878 SILICON ANOMALY This anomaly list describes the known issues with the ADE7854, ADE7858, ADE7868, and ADE7878 silicon identified by the version register (Address 0xE707) being equal to 2 and to 4. Analog Devices, Inc., is committed, through future silicon revisions, to continuously improve silicon functionality. Analog Devices tries to ensure that these future silicon revisions remain compatible with your present software/systems by implementing the recommended workarounds outlined here. ADE7854/ADE7858/ADE7868/ADE7878 FUNCTIONALITY ISSUES Silicon Revision Identifier Version = 2 Version = 4 Chip Marking ADE7854ACPZ ADE7858ACPZ ADE7868ACPZ ADE7878ACPZ ADE7854ACPZ ADE7858ACPZ ADE7868ACPZ ADE7878ACPZ Silicon Status Released Anomaly Sheet Rev. A No. of Reported Issues 4 (er001, er002, er003, er004) Released Rev. B 1 (er005) FUNCTIONALITY ISSUES Table 25. Offset RMS Registers Cannot be Set to Negative Values [er001, Version = 2 Silicon] Background Issue Workaround Related Issues When the AIRMSOS, AVRMSOS, BIRMSOS, BVRMSOS, CIRMSOS, CVRMSOS, and NIRMSOS registers are set to a negative value, for sufficiently small inputs, the argument of the square root used in the rms data path may become negative. In this case, the corresponding AIRMS, AVRMS, BIRMS, BVRMS, CIRMS, or CVRMS rms register is automatically set to 0. Negative values for the AIRMSOS, AVRMSOS, BIRMSOS, BVRMSOS, CIRMSOS, CVRMSOS, and NIRMSOS registers are not supported in the silicon version identified by the version register being equal to 2. Do not use negative values for the AIRMSOS, AVRMSOS, BIRMSOS, BVRMSOS, CIRMSOS, CVRMSOS, and NIRMSOS registers. If further details on this issue are required, please use the following website to submit your query: www.analog.com/en/content/technical_support_page/fca.html. None. Table 26. Values Written to the CF1DEN, CF2DEN, CF3DEN, SAGLVL, and ZXTOUT Registers May Not Be Immediately Used By ADE7854, ADE7858, ADE7868, ADE7878 [er002, Version = 2 Silicon] Background Issue Workaround Related Issues Usually, the CF1DEN, CF2DEN, CF3DEN, SAGLVL, and ZXTOUT registers initialize immediately after power-up or after a hardware/software reset. After the RUN register is set to 1, the energy-to-frequency converter (for CF1DEN, CF2DEN, and CF3DEN), the phase voltage sag detector (for SAGLVL), and the zero-crossing timeout circuit (for ZXTOUT) use these values immediately. After the CF1DEN register is initialized with a new value after power-up or a hardware/software reset, the new value may be delayed and, therefore, not immediately available for use by the energy-to-frequency converter. It is, however, used by the converter after the first high-to-low transition is triggered at t the CF1 pin using the CF1DEN default value (0x0). CF2DEN and CF3DEN registers present similar behavior at the CF2 and CF3 pins, respectively. CF1DEN, CF2DEN and CF3DEN above behavior has been corrected in Version = 4 silicon. After the SAGLVL register is initialized with a new value after power-up or a hardware or software reset, the new value may be delayed and not available for immediate use by the phase voltage sag detector. However, it is used by the detector after at least one phase voltage rises above 10% of the full-scale input at the phase voltage ADCs. After the ZXTOUT register is initialized with a new value after power-up or a hardware or software reset, the new value may be delayed and not available for immediate use by the zero-crossing timeout circuit. However, the circuit does use the new value after at least one phase voltage rises above 10% of the full-scale input at the phase voltage ADCs. If the behavior outlined in the Issue row does not conflict with the meter specification, then the new values of the CF1DEN, CF2DEN, CF3DEN, SAGLVL, and ZXTOUT registers may be written one time only. If the behavior is not acceptable, write the new value into the CF1DEN, CF2DEN, and CF3DEN registers eight consecutive times. This ensures the probability of the new value not being considered immediately by the energy-to-frequency converter becomes lower than 0.2 ppm. Usually, at least one of the phase voltages is greater than 10% of full scale after power-up or after a hardware/software reset. If this cannot be guaranteed, then the SAGLVL and ZXTOUT registers should also be written eight consecutive times to reduce the probability of not being considered immediately by the phase voltage sag detector and zero-crossing timeout circuit. None. Rev. E | Page 73 of 96 ADE7854/ADE7858/ADE7868/ADE7878 Table 27. The Read-Only RMS Registers May Show the Wrong Value [er003, Version = 2 Silicon] Background Issue Workaround Related Issues The read-only rms registers (AVRMS, BVRMS, CVRMS, AIRMS, BIRMS, CIRMS, and NIRMS) can be read without restrictions at any time. The fixed function DSP of ADE7854, ADE7858, ADE7868, and ADE7878 computes all the powers and rms values in a loop with a period of 125 s (8 kHz frequency). If two rms registers are accessed (read) consecutively, the value of the second register may be corrupted. Consequently, the apparent power computed during that 125 s cycle is also corrupted. The rms calculation recovers in the next 125 s cycle, and all the rms and apparent power values compute correctly. The issue appears independent of the communication type, SPI or I2C, when the time between the start of two consecutive rms readings is lower than 265 s. The issue affects only the rms registers; all of the other registers of ADE7854, ADE7858, ADE7868, and ADE7878 can be accessed without any restrictions. The rms registers can be read one at a time with at least 265 s between the start of the readings. DREADY interrupt at the IRQ0 pin can be used to time one rms register reading every three consecutive DREADY interrupts. This ensures 375 s between the start of the rms readings. Alternatively, the rms registers can be read interleaved with readings of other registers that are not affected by this restriction as long as the time between the start of two consecutive rms register readings is 265 s. None. Table 28. To Obtain Best Accuracy Performance, Internal Setting Must Be Changed [er004, Version = 2 Silicon] Background Issue Workaround Related Issues Internal default settings provide best accuracy performance for ADE7854, ADE7858, ADE7868, and ADE7878. It was found that if a different setting is used, the accuracy performance can be improved. To enable a new setting for this internal register, execute two consecutive 8-bit register write operations: The first write operation: 0xAD is written to Address 0xE7FE. The second write operation: 0x01 is written to Address 0xE7E2. The write operations must be executed consecutively without any other read/write operation in between. As a verification that the value was captured correctly, a simple 8-bit read of Address 0xE7E2 should show the 0x01 value. None. Table 29. Values Written to the SAGLVL and ZXTOUT Registers May Not Be Immediately Used by ADE7854, ADE7858, ADE7868, and ADE7878 [er005, Version = 4 Silicon] Background Issue Workaround Related Issues Usually, the SAGLVL and ZXTOUT registers initialize immediately after power-up or after a hardware/software reset. After the run register is set to 1, the phase voltage sag detector (for SAGLVL), and the zero-crossing timeout circuit (for ZXTOUT) use these values immediately. After the SAGLVL register is initialized with a new value after power-up or a hardware or software reset, the new value may be delayed and not available for immediate use by the phase voltage sag detector. However, it is used by the detector after at least one phase voltage rises above 10% of the full-scale input at the phase voltage ADCs. After the ZXTOUT register is initialized with a new value after power-up or a hardware or software reset, the new value may be delayed and not available for immediate use by the zero-crossing timeout circuit. However, the circuit does use the new value after at least one phase voltage rises above 10% of the full-scale input at the phase voltage ADCs. Usually, at least one of the phase voltages is greater than 10% of full scale after power-up or after a hardware/software reset. If this cannot be guaranteed, then the SAGLVL and ZXTOUT registers should be written eight consecutive times to reduce the probability of not being considered immediately by the phase voltage sag detector and zero-crossing timeout circuit below 0.2 ppm. None. SECTION 1. ADE7854/ADE7858/ADE7868/ADE7878 FUNCTIONALITY ISSUES Reference Number er001 er002 er003 er004 er005 Description Offset rms registers cannot be set to negative values. Values written to the CF1DEN, CF2DEN, CF2DEN, SAGLVL, and ZXTOUT registers may not be immediately used by ADE7854, ADE7858, ADE7868, and ADE7878. The read-only rms registers may show the wrong value. To obtain best accuracy performance, internal setting must be changed. Values written to the SAGLVL and ZXTOUT registers may not be immediately used by ADE7854, ADE7858, ADE7868, and ADE7878. This completes the Silicon Anomaly section. Rev. E | Page 74 of 96 Status Identified Identified Identified Identified Identified ADE7854/ADE7858/ADE7868/ADE7878 REGISTERS LIST Table 30. Registers List Located in DSP Data Memory RAM Address 0x4380 0x4381 0x4382 0x4383 0x4384 0x4385 0x4386 Register Name AIGAIN AVGAIN BIGAIN BVGAIN CIGAIN CVGAIN NIGAIN R/W 1 R/W R/W R/W R/W R/W R/W R/W Bit Length 24 24 24 24 24 24 24 Bit Length During Communication 2 32 ZPSE 32 ZPSE 32 ZPSE 32 ZPSE 32 ZPSE 32 ZPSE 32 ZPSE Type 3 S S S S S S S Default Value 0x000000 0x000000 0x000000 0x000000 0x000000 0x000000 0x000000 0x4387 0x4388 0x4389 0x438A 0x438B 0x438C 0x438D AIRMSOS AVRMSOS BIRMSOS BVRMSOS CIRMSOS CVRMSOS NIRMSOS R/W R/W R/W R/W R/W R/W R/W 24 24 24 24 24 24 24 32 ZPSE 32 ZPSE 32 ZPSE 32 ZPSE 32 ZPSE 32 ZPSE 32 ZPSE S S S S S S S 0x000000 0x000000 0x000000 0x000000 0x000000 0x000000 0x000000 0x438E 0x438F 0x4390 0x4391 0x4392 0x4393 0x4394 0x4395 0x4396 0x4397 AVAGAIN BVAGAIN CVAGAIN AWGAIN AWATTOS BWGAIN BWATTOS CWGAIN CWATTOS AVARGAIN R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W 24 24 24 24 24 24 24 24 24 24 32 ZPSE 32 ZPSE 32 ZPSE 32 ZPSE 32 ZPSE 32 ZPSE 32 ZPSE 32 ZPSE 32 ZPSE 32 ZPSE S S S S S S S S S S 0x000000 0x000000 0x000000 0x000000 0x000000 0x000000 0x000000 0x000000 0x000000 0x000000 0x4398 AVAROS R/W 24 32 ZPSE S 0x000000 0x4399 BVARGAIN R/W 24 32 ZPSE S 0x000000 0x439A BVAROS R/W 24 32 ZPSE S 0x000000 0x439B CVARGAIN R/W 24 32 ZPSE S 0x000000 0x439C CVAROS R/W 24 32 ZPSE S 0x000000 0x439D AFWGAIN R/W 24 32 ZPSE S 0x000000 0x439E AFWATTOS R/W 24 32 ZPSE S 0x000000 0x439F BFWGAIN R/W 24 32 ZPSE S 0x000000 0x43A0 BFWATTOS R/W 24 32 ZPSE S 0x000000 0x43A1 CFWGAIN R/W 24 32 ZPSE S 0x000000 0x43A2 CFWATTOS R/W 24 32 ZPSE S 0x000000 Rev. E | Page 75 of 96 Description Phase A current gain adjust. Phase A voltage gain adjust. Phase B current gain adjust. Phase B voltage gain adjust. Phase C current gain adjust. Phase C voltage gain adjust. Neutral current rms offset (ADE7868 and ADE7878 only). Phase A current rms offset. Phase A voltage rms offset. Phase B current rms offset. Phase B voltage rms offset. Phase C current rms offset. Phase C voltage rms offset. Neutral current rms offset (ADE7868 and ADE7878 only). Phase A apparent power gain adjust. Phase B apparent power gain adjust. Phase C apparent power gain adjust. Phase A total active power gain adjust. Phase A total active power offset adjust. Phase B total active power gain adjust. Phase B total active power offset adjust. Phase C total active power gain adjust. Phase C total active power offset adjust. Phase A total reactive power gain adjust (ADE7858, ADE7868, ADE7878 only). Phase A total reactive power offset adjust (ADE7858, ADE7868, ADE7878 only). Phase B total reactive power gain adjust (ADE7858, ADE7868, ADE7878 only). Phase B total reactive power offset adjust (ADE7858, ADE7868, and ADE7878 only). Phase C total reactive power gain adjust (ADE7858, ADE7868, and ADE7878 only). Phase C total reactive power offset adjust (ADE7858, ADE7868, and ADE7878 only). Phase A fundamental active power gain adjust. Location reserved for ADE7854, ADE7858, and ADE7868. Phase A fundamental active power offset adjust. Location reserved for ADE7854, ADE7858, and ADE7868. Phase B fundamental active power gain adjust (ADE7878 only). Phase B fundamental active power offset adjust (ADE7878 only). Phase C fundamental active power gain adjust. Phase C fundamental active power offset adjust (ADE7878 only). ADE7854/ADE7858/ADE7868/ADE7878 Address 0x43A3 Register Name AFVARGAIN R/W 1 R/W Bit Length 24 Bit Length During Communication 2 32 ZPSE Type 3 S Default Value 0x000000 0x43A4 AFVAROS R/W 24 32 ZPSE S 0x000000 0x43A5 BFVARGAIN R/W 24 32 ZPSE S 0x000000 0x43A6 BFVAROS R/W 24 32 ZPSE S 0x000000 0x43A7 CFVARGAIN, R/W 24 32 ZPSE S 0x000000 0x43A8 CFVAROS R/W 24 32 ZPSE S 0x000000 0x43A9 VATHR1 R/W 24 32 ZP U 0x000000 0x43AA VATHR0 R/W 24 32 ZP U 0x000000 0x43AB WTHR1 R/W 24 32 ZP U 0x000000 0x43AC WTHR0 R/W 24 32 ZP U 0x000000 0x43AD VARTHR1 R/W 24 32 ZP U 0x000000 0x43AE VARTHR0 R/W 24 32 ZP U 0x000000 0x43AF Reserved N/A 4 N/A4 N/A4 N/A4 0x000000 0x43B0 VANOLOAD R/W 24 32 ZPSE S 0x0000000 0x43B1 APNOLOAD R/W 24 32 ZPSE S 0x0000000 0x43B2 VARNOLOAD R/W 24 32 ZPSE S 0x0000000 0x43B3 VLEVEL R/W 24 32 ZPSE S 0x000000 0x43B4 Reserved N/A4 N/A4 N/A4 N/A4 0x000000 0x43B5 DICOEFF R/W 24 32 ZPSE S 0x0000000 0x43B6 HPFDIS R/W 24 32 ZP U 0x000000 0x43B7 Reserved N/A4 N/A4 N/A4 N/A4 0x000000 0x43B8 ISUMLVL R/W 24 32 ZPSE S 0x000000 Rev. E | Page 76 of 96 Description Phase A fundamental reactive power gain adjust (ADE7878 only). Phase A fundamental reactive power offset adjust (ADE7878 only). Phase B fundamental reactive power gain adjust (ADE7878 only). Phase B fundamental reactive power offset adjust (ADE7878 only). Phase C fundamental reactive power gain adjust (ADE7878 only). Phase C fundamental reactive power offset adjust (ADE7878 only). Most significant 24 bits of VATHR[47:0] threshold used in phase apparent power datapath. Less significant 24 bits of VATHR[47:0] threshold used in phase apparent power datapath. Most significant 24 bits of WTHR[47:0] threshold used in phase total/fundamental active power datapath. Less significant 24 bits of WTHR[47:0] threshold used in phase total/fundamental active power datapath. Most significant 24 bits of VARTHR[47:0] threshold used in phase total/fundamental reactive power datapath (ADE7858, ADE7868, ADE7878 only). Less significant 24 bits of VARTHR[47:0] threshold used in phase total/fundamental reactive power datapath (ADE7858, ADE7868, ADE7878 only). This memory location should be kept at 0x000000 for proper operation. No load threshold in the apparent power datapath. No load threshold in the total/fundamental active power datapath. No load threshold in the total/fundamental reactive power datapath. Location reserved for ADE7854. Register used in the algorithm that computes the fundamental active and reactive powers (ADE7878 only). This location should not be written for proper operation. Register used in the digital integrator algorithm. If the integrator is turned on, it must be set at 0xFF8000. In practice, it is transmitted as 0xFFF8000. Disables/enables the HPF in the current datapath (see Table 34). This memory location should be kept at 0x000000 for proper operation. Threshold used in comparison between the sum of phase currents and the neutral current (ADE7868 and ADE7878 only). ADE7854/ADE7858/ADE7868/ADE7878 Register Name Reserved R/W 1 N/A4 Bit Length N/A4 Bit Length During Communication 2 N/A4 Type 3 N/A4 Default Value 0x000000 ISUM R 28 32 ZP S N/A4 0x43C0 0x43C1 0x43C2 0x43C3 0x43C4 0x43C5 0x43C6 AIRMS AVRMS BIRMS BVRMS CIRMS CVRMS NIRMS R R R R R R R 24 24 24 24 24 24 24 32 ZP 32 ZP 32 ZP 32 ZP 32 ZP 32 ZP 32 ZP S S S S S S S N/A4 N/A4 N/A4 N/A4 N/A4 N/A4 N/A4 0x43C7 to 0x43FF Reserved N/A4 N/A4 N/A4 N/A4 N/A4 Address 0x43B9 to 0x43BE 0x43BF Description These memory locations should be kept at 0x000000 for proper operation. Sum of IAWV, IBWV, and ICWV registers (ADE7868 and ADE7878 only). Phase A current rms value. Phase A voltage rms value. Phase B current rms value. Phase B voltage rms value. Phase C current rms value. Phase C voltage rms value. Neutral current rms value (ADE7868 and ADE7878 only). These memory locations should not be written for proper operation. 1 R is read, and W is write. 32 ZPSE = 24-bit signed register that is transmitted as a 32-bit word with four MSBs padded with 0s and sign extended to 28 bits. Whereas 32 ZP = 28- or 24-bit signed or unsigned register that is transmitted as a 32-bit word with four MSBs or eight MSBs, respectively, padded with 0s. 3 U is unsigned register, and S is signed register in twos complement format. 4 N/A means not applicable. 2 Table 31. Internal DSP Memory RAM Registers Address 0xE203 Register Name Reserved 0xE228 Run 1 2 R/W 1 R/W Bit Length 16 Bit Length During Communication 16 Type 2 U Default Value 0x0000 R/W 16 16 U 0x0000 Description This memory location should not be written for proper operation. Run register starts and stops the DSP. See the Digital Signal Processor section for more details. R is read, and W is write. U is unsigned register, and S is signed register in twos complement format. Table 32. Billable Registers R/W 1, 2 R R R R Bit Length2 32 32 32 32 Bit Length During Communication2 32 32 32 32 Type2, 3 S S S S Default Value 0x00000000 0x00000000 0x00000000 0x00000000 BFWATTHR R 32 32 S 0x00000000 0xE405 CFWATTHR R 32 32 S 0x00000000 0xE406 AVARHR R 32 32 S 0x00000000 0xE407 BVARHR R 32 32 S 0x00000000 0xE408 CVARHR R 32 32 S 0x00000000 0xE409 AFVARHR R 32 32 S 0x00000000 0xE40A BFVARHR R 32 32 S 0x00000000 0xE40B CFVARHR R 32 32 S 0x00000000 Address 0xE400 0xE401 0xE402 0xE403 Register Name AWATTHR BWATTHR CWATTHR AFWATTHR 0xE404 Rev. E | Page 77 of 96 Description Phase A total active energy accumulation. Phase B total active energy accumulation. Phase C total active energy accumulation. Phase A fundamental active energy accumulation (ADE7878 only). Phase B fundamental active energy accumulation (ADE7878 only). Phase C fundamental active energy accumulation (ADE7878 only). Phase A total reactive energy accumulation (ADE7858, ADE7868, and ADE7878 only). Phase B total reactive energy accumulation (ADE7858, ADE7868, and ADE7878 only). Phase C total reactive energy accumulation (ADE7858, ADE7868, and ADE7878 only). Phase A fundamental reactive energy accumulation (ADE7878 only). Phase B fundamental reactive energy accumulation (ADE7878 only). Phase C fundamental reactive energy accumulation (ADE7878 only). ADE7854/ADE7858/ADE7868/ADE7878 Address 0xE40C 0xE40D 0xE40E 1 2 3 Register Name AVAHR BVAHR CVAHR R/W 1, 2 R R R Bit Length2 32 32 32 Bit Length During Communication2 32 32 32 Type2, 3 S S S Default Value 0x00000000 0x00000000 0x00000000 Description Phase A apparent energy accumulation. Phase B apparent energy accumulation. Phase C apparent energy accumulation. R is read, and W is write. N/A is not applicable. U is unsigned register, and S is signed register in twos complement format. Table 33. Configuration and Power Quality Registers R/W 1 R Bit Length 32 Bit Length During Communication 2 32 Type 3 U Default Value 4 N/A VPEAK R 32 32 U N/A 0xE502 0xE503 0xE504 STATUS0 STATUS1 AIMAV R/W R/W R 32 32 20 32 32 32 ZP U U U N/A N/A N/A 0xE505 BIMAV R 20 32 ZP U N/A 0xE506 CIMAV R 20 32 ZP U N/A 0xE507 0xE508 0xE509 0xE50A 0xE50B 0xE50C 0xE50D 0xE50E 0xE50F OILVL OVLVL SAGLVL MASK0 MASK1 IAWV IBWV ICWV INWV R/W R/W R/W R/W R/W R R R R 24 24 24 32 32 24 24 24 24 32 ZP 32 ZP 32 ZP 32 32 32 SE 32 SE 32 SE 32 SE U U U U U S S S S 0xFFFFFF 0xFFFFFF 0x000000 0x00000000 0x00000000 N/A N/A N/A N/A 0xE510 0xE511 0xE512 0xE513 VAWV VBWV VCWV AWATT R R R R 24 24 24 24 32 SE 32 SE 32 SE 32 SE S S S S N/A N/A N/A N/A 0xE514 BWATT R 24 32 SE S N/A 0xE515 CWATT R 24 32 SE S N/A 0xE516 AVAR R 24 32 SE S N/A 0xE517 BVAR R 24 32 SE S N/A 0xE518 CVAR R 24 32 SE S N/A Address 0xE500 Register Name IPEAK 0xE501 Rev. E | Page 78 of 96 Description Current peak register. See Figure 48 and Table 35 for details about its composition. Voltage peak register. See Figure 48 and Table 36 for details about its composition. Interrupt Status Register 0. See Table 37. Interrupt Status Register 1. See Table 38. Phase A current mean absolute value computed during PSM0 and PSM1 modes (ADE7868 and ADE7878 only). Phase B current mean absolute value computed during PSM0 and PSM1 modes (ADE7868 and ADE7878 only). Phase C current mean absolute value computed during PSM0 and PSM1 modes (ADE7868 and ADE7878 only). Overcurrent threshold. Overvoltage threshold. Voltage SAG level threshold. Interrupt Enable Register 0. See Table 39. Interrupt Enable Register 1. See Table 40. Instantaneous value of Phase A current. Instantaneous value of Phase B current. Instantaneous value of Phase C current. Instantaneous value of neutral current (ADE7868 and ADE7878 only). Instantaneous value of Phase A voltage. Instantaneous value of Phase B voltage. Instantaneous value of Phase C voltage. Instantaneous value of Phase A total active power. Instantaneous value of Phase B total active power. Instantaneous value of Phase C total active power. Instantaneous value of Phase A total reactive power (ADE7858, ADE7868, and ADE7878 only). Instantaneous value of Phase B total reactive power (ADE7858, ADE7868, and ADE7878 only). Instantaneous value of Phase C total reactive power (ADE7858, ADE7868, and ADE7878 only). ADE7854/ADE7858/ADE7868/ADE7878 R/W 1 R Bit Length 24 Bit Length During Communication 2 32 SE Type 3 S Default Value 4 N/A BVA R 24 32 SE S N/A 0xE51B CVA R 24 32 SE S N/A 0xE51F CHECKSUM R 32 32 U 0x33666787 0xE520 VNOM R/W 24 32 ZP S 0x000000 0xE521 to 0xE52E 0xE600 0xE601 Reserved PHSTATUS ANGLE0 R R 16 16 16 16 U U N/A N/A 0xE602 ANGLE1 R 16 16 U N/A 0xE603 ANGLE2 R 16 16 U N/A 0xE604 to 0xE606 0xE607 0xE608 0xE609 to 0xE60B 0xE60C 0xE60D 0xE60E Reserved PERIOD PHNOLOAD Reserved R R 16 16 16 16 U U N/A N/A LINECYC ZXTOUT COMPMODE R/W R/W R/W 16 16 16 16 16 16 U U U 0xFFFF 0xFFFF 0x01FF 0xE60F 0xE610 0xE611 0xE612 0xE613 0xE614 Gain CFMODE CF1DEN CF2DEN CF3DEN APHCAL R/W R/W R/W R/W R/W R/W 16 16 16 16 16 10 16 16 16 16 16 16 ZP U U U U U U 0x0000 0x0E88 0x0000 0x0000 0x0000 0x0000 0xE615 0xE616 0xE617 0xE618 BPHCAL CPHCAL PHSIGN CONFIG R/W R/W R R/W 10 10 16 16 16 ZP 16 ZP 16 16 U U U U 0x0000 0x0000 N/A 0x0000 0xE700 MMODE R/W 8 8 U 0x1C 0xE701 ACCMODE R/W 8 8 U 0x00 0xE702 LCYCMODE R/W 8 8 U 0x78 0xE703 0xE704 0xE705 PEAKCYC SAGCYC CFCYC R/W R/W R/W 8 8 8 8 8 8 U U U 0x00 0x00 0x01 0xE706 HSDC_CFG R/W 8 8 U 0x00 Address 0xE519 Register Name AVA 0xE51A Rev. E | Page 79 of 96 Description Instantaneous value of Phase A apparent power. Instantaneous value of Phase B apparent power. Instantaneous value of Phase C apparent power. Checksum verification. See the Checksum Register section for details. Nominal phase voltage rms used in the alternative computation of the apparent power. These addresses should not be written for proper operation. Phase peak register. See Table 41. Time Delay 0. See the Time Interval Between Phases section for details. Time Delay 1. See the Time Interval Between Phases section for details. Time Delay 2. See the Time Interval Between Phases section for details. These addresses should not be written for proper operation. Network line period. Phase no load register. See Table 42. These addresses should not be written for proper operation. Line cycle accumulation mode count. Zero-crossing timeout count. Computation-mode register. See Table 43. PGA gains at ADC inputs. See Table 44. CFx configuration register. See Table 45. CF1 denominator. CF2 denominator. CF3 denominator. Phase calibration of Phase A. See Table 46. Phase calibration of Phase B. See Table 46. Phase calibration of Phase C. See Table 46. Power sign register. See Table 47. ADE7878 configuration register. See Table 48. Measurement mode register. See Table 49. Accumulation mode register. See Table 50. Line accumulation mode behavior. See Table 52. Peak detection half line cycles. SAG detection half line cycles. Number of CF pulses between two consecutive energy latches. See the Synchronizing Energy Registers with CFx Outputs section. HSDC configuration register. See Table 53. ADE7854/ADE7858/ADE7868/ADE7878 R/W 1 R Bit Length 8 8 Bit Length During Communication 2 8 8 Type 3 U LPOILVL R/W 8 8 U 0x07 CONFIG2 R/W 8 8 U 0x00 Address 0xE707 0xEBFF Register Name Version Reserved 0xEC00 0xEC01 Default Value 4 Description Version of die. This address can be used in manipulating the SS/HSA pin when SPI is chosen as the active port. See the Serial Interfaces section for details. Overcurrent threshold used during PSM2 mode (ADE7868 and ADE7878 only). See Table 54 in which the register is detailed. Configuration register used during PSM1 mode. See Table 55. 1 R is read, and W is write. 32 ZP = 24- or 20-bit signed or unsigned register that is transmitted as a 32-bit word with 8 or 12 MSBs, respectively, padded with 0s. 32 SE = 24-bit signed register that is transmitted as a 32-bit word sign extended to 32 bits. 16 ZP = 10-bit unsigned register that is transmitted as a 16-bit word with six MSBs padded with 0s. 3 U is unsigned register, and S is signed register in twos complement format. 4 N/A is not applicable. 2 Table 34. HPFDIS Register (Address 0x43B6) Bit Location 23:0 Default Value 00000000 Description When HPFDIS = 0x00000000, then all high-pass filters in voltage and current channels are enabled. When the register is set to any nonzero value, all high-pass filters are disabled. Table 35. IPEAK Register (Address 0xE500) Bit Location 23:0 24 25 26 31:27 Bit Mnemonic IPEAKVAL[23:0] IPPHASE[0] IPPHASE[1] IPPHASE[2] Default Value 0 0 0 0 00000 Description These bits contain the peak value determined in the current channel. When this bit is set to 1, Phase A current generated IPEAKVAL[23:0] value. When this bit is set to 1, Phase B current generated IPEAKVAL[23:0] value. When this bit is set to 1, Phase C current generated IPEAKVAL[23:0] value. These bits are always 0. Table 36. VPEAK Register (Address 0xE501) Bit Location 23:0 24 25 26 31:27 Bit Mnemonic VPEAKVAL[23:0] VPPHASE[0] VPPHASE[1] VPPHASE[2] Default Value 0 0 0 0 00000 Description These bits contain the peak value determined in the voltage channel. When this bit is set to 1, Phase A voltage generated VPEAKVAL[23:0] value. When this bit is set to 1, Phase B voltage generated VPEAKVAL[23:0] value. When this bit is set to 1, Phase C voltage generated VPEAKVAL[23:0] value. These bits are always 0. Table 37. STATUS0 Register (Address 0xE502) Bit Location 0 Bit Mnemonic AEHF Default Value 0 1 FAEHF 0 2 REHF 0 3 FREHF 0 4 VAEHF 0 5 LENERGY 0 Description When this bit is set to 1, it indicates that Bit 30 of any one of the total active energy registers (AWATTHR, BWATTHR, or CWATTHR) has changed. When this bit is set to 1, it indicates that Bit 30 of any one of the fundamental active energy registers, FWATTHR, BFWATTHR, or CFWATTHR, has changed. This bit is always 0 for ADE7854, ADE7858, and ADE7868. When this bit is set to 1, it indicates that Bit 30 of any one of the total reactive energy registers (AVARHR, BVARHR, or CVARHR) has changed. This bit is always 0 for ADE7854. When this bit is set to 1, it indicates that Bit 30 of any one of the fundamental reactive energy registers, AFVARHR, BFVARHR, or CFVARHR, has changed. This bit is always 0 for ADE7854, ADE7858, and ADE7868. When this bit is set to 1, it indicates that Bit 30 of any one of the apparent energy registers (AVAHR, BVAHR, or CVAHR) has changed. When this bit is set to 1, in line energy accumulation mode, it indicates the end of an integration over an integer number of half line cycles set in the LINECYC register. Rev. E | Page 80 of 96 ADE7854/ADE7858/ADE7868/ADE7878 Bit Location 6 Bit Mnemonic REVAPA Default Value 0 7 REVAPB 0 8 REVAPC 0 9 REVPSUM1 0 10 REVRPA 0 11 REVRPB 0 12 REVRPC 0 13 REVPSUM2 0 14 CF1 15 CF2 16 CF3 17 DREADY 0 18 REVPSUM3 0 31:19 Reserved 0 0000 0000 0000 Description When this bit is set to 1, it indicates that the Phase A active power identified by Bit 6 (REVAPSEL) in the ACCMODE register (total or fundamental) has changed sign. The sign itself is indicated in Bit 0 (AWSIGN) of the PHSIGN register (see Table 47). When this bit is set to 1, it indicates that the Phase B active power identified by Bit 6 (REVAPSEL) in the ACCMODE register (total or fundamental) has changed sign. The sign itself is indicated in Bit 1 (BWSIGN) of the PHSIGN register (see Table 47). When this bit is set to 1, it indicates that the Phase C active power identified by Bit 6 (REVAPSEL) in the ACCMODE register (total or fundamental) has changed sign. The sign itself is indicated in Bit 2 (CWSIGN) of the PHSIGN register (see Table 47). When this bit is set to 1, it indicates that the sum of all phase powers in the CF1 datapath has changed sign. The sign itself is indicated in Bit 3 (SUM1SIGN) of the PHSIGN register (see Table 47). When this bit is set to 1, it indicates that the Phase A reactive power identified by Bit 7 (REVRPSEL) in the ACCMODE register (total or fundamental) has changed sign. The sign itself is indicated in Bit 4 (AVARSIGN) of the PHSIGN register (see Table 47). This bit is always 0 for ADE7854. When this bit is set to 1, it indicates that the Phase B reactive power identified by Bit 7 (REVRPSEL) in the ACCMODE register (total or fundamental) has changed sign. The sign itself is indicated in Bit 5 (BVARSIGN) of the PHSIGN register (see Table 47). This bit is always 0 for ADE7854. When this bit is set to 1, it indicates that the Phase C reactive power identified by Bit 7 (REVRPSEL) in the ACCMODE register (total or fundamental) has changed sign. The sign itself is indicated in Bit 6 (CVARSIGN) of the PHSIGN register (see Table 47). This bit is always 0 for ADE7854. When this bit is set to 1, it indicates that the sum of all phase powers in the CF2 datapath has changed sign. The sign itself is indicated in Bit 7 (SUM2SIGN) of the PHSIGN register (see Table 47). When this bit is set to 1, it indicates a high to low transition has occurred at CF1 pin; that is, an active low pulse has been generated. The bit is set even if the CF1 output is disabled by setting Bit 9 (CF1DIS) to 1 in the CFMODE register. The type of power used at the CF1 pin is determined by Bits[2:0] (CF1SEL[2:0]) in the CFMODE register (see Table 45). When this bit is set to 1, it indicates a high-to-low transition has occurred at the CF2 pin; that is, an active low pulse has been generated. The bit is set even if the CF2 output is disabled by setting Bit 10 (CF2DIS) to 1 in the CFMODE register. The type of power used at the CF2 pin is determined by Bits[5:3] (CF2SEL[2:0]) in the CFMODE register (see Table 45). When this bit is set to 1, it indicates a high-to-low transition has occurred at CF3 pin; that is, an active low pulse has been generated. The bit is set even if the CF3 output is disabled by setting Bit 11 (CF3DIS) to 1 in the CFMODE register. The type of power used at the CF3 pin is determined by Bits[8:6] (CF3SEL[2:0]) in the CFMODE register (see Table 45). When this bit is set to 1, it indicates that all periodical (at 8 kHz rate) DSP computations have finished. When this bit is set to 1, it indicates that the sum of all phase powers in the CF3 datapath has changed sign. The sign itself is indicated in Bit 8 (SUM3SIGN) of the PHSIGN register (see Table 47). Reserved. These bits are always 0. Table 38. STATUS1 Register (Address 0xE503) Bit Location 0 Bit Mnemonic NLOAD Default Value 0 1 FNLOAD 0 Description When this bit is set to 1, it indicates that at least one phase entered no load condition based on total active and reactive powers. The phase is indicated in Bits[2:0] (NLPHASE[x]) in the PHNOLOAD register (see Table 42). When this bit is set to 1, it indicates that at least one phase entered no load condition based on fundamental active and reactive powers. The phase is indicated in Bits[5:3] (FNLPHASE[x]) in PHNOLOAD register (see Table 42 in which this register is described). This bit is always 0 for ADE7854, ADE7858, and ADE7868. Rev. E| Page 81 of 96 ADE7854/ADE7858/ADE7868/ADE7878 Bit Location 2 Bit Mnemonic VANLOAD Default Value 0 3 4 5 6 7 8 9 10 11 12 13 14 15 ZXTOVA ZXTOVB ZXTOVC ZXTOIA ZXTOIB ZXTOIC ZXVA ZXVB ZXVC ZXIA ZXIB ZXIC RSTDONE 0 0 0 0 0 0 0 0 0 0 0 0 1 16 SAG 0 17 OI 0 18 OV 0 19 SEQERR 0 20 MISMTCH 0 21 22 23 Reserved Reserved PKI 1 0 0 24 PKV 0 31:25 Reserved 000 0000 Description When this bit is set to 1, it indicates that at least one phase entered no load condition based on apparent power. The phase is indicated in Bits[8:6] (VANLPHASE[x]) in the PHNOLOAD register (see Table 42). When this bit is set to 1, it indicates a zero crossing on Phase A voltage is missing. When this bit is set to 1, it indicates a zero crossing on Phase B voltage is missing. When this bit is set to 1, it indicates a zero crossing on Phase C voltage is missing. When this bit is set to 1, it indicates a zero crossing on Phase A current is missing. When this bit is set to 1, it indicates a zero crossing on Phase B current is missing. When this bit is set to 1, it indicates a zero crossing on Phase C current is missing. When this bit is set to 1, it indicates a zero crossing has been detected on Phase A voltage. When this bit is set to 1, it indicates a zero crossing has been detected on Phase B voltage. When this bit is set to 1, it indicates a zero crossing has been detected on Phase C voltage. When this bit is set to 1, it indicates a zero crossing has been detected on Phase A current. When this bit is set to 1, it indicates a zero crossing has been detected on Phase B current. When this bit is set to 1, it indicates a zero crossing has been detected on Phase C current. In case of a software reset command, Bit 7 (SWRST) is set to 1 in the CONFIG register, or a transition from PSM1, PSM2, or PSM3 to PSM0, or a hardware reset, this bit is set to 1 at the end of the transition process and after all registers changed value to default. The IRQ1 pin goes low to signal this moment because this interrupt cannot be disabled. When this bit is set to 1, it indicates a SAG event has occurred on one of the phases indicated by Bits[14:12] (VSPHASE[x]) in the PHSTATUS register (see Table 41). When this bit is set to 1, it indicates an overcurrent event has occurred on one of the phases indicated by Bits[5:3] (OIPHASE[x]) in the PHSTATUS register (see Table 41). When this bit is set to 1, it indicates an overvoltage event has occurred on one of the phases indicated by Bits[11:9] (OVPHASE[x]) in the PHSTATUS register (see Table 41). When this bit is set to 1, it indicates a negative-to-positive zero crossing on Phase A voltage was not followed by a negative-to-positive zero crossing on Phase B voltage but by a negative-to-positive zero crossing on Phase C voltage. When this bit is set to 1, it indicates ISUM - INWV > ISUMLVL , where ISUMLVL is indicated in the ISUMLVL register. This bit is always 0 for ADE7854 and ADE7858. Reserved. This bit is always set to 1. Reserved. This bit is always set to 0. When this bit is set to 1, it indicates that the period used to detect the peak value in the current channel has ended. The IPEAK register contains the peak value and the phase where the peak has been detected (see Table 35). When this bit is set to 1, it indicates that the period used to detect the peak value in the voltage channel has ended. VPEAK register contains the peak value and the phase where the peak has been detected (see Table 36). Reserved. These bits are always 0. Table 39. MASK0 Register (Address 0xE50A) Bit Location 0 Bit Mnemonic AEHF Default Value 0 1 FAEHF 0 2 REHF 0 3 FREHF 0 Description When this bit is set to 1, it enables an interrupt when Bit 30 of any one of the total active energy registers (AWATTHR, BWATTHR, or CWATTHR) changes. When this bit is set to 1, it enables an interrupt when Bit 30 of any one of the fundamental active energy registers (AFWATTHR, BFWATTHR, or CFWATTHR) changes. Setting this bit to1 does not have any consequence for ADE7854, ADE7858, and ADE7868. When this bit is set to 1, it enables an interrupt when Bit 30 of any one of the total reactive energy registers (AVARHR, BVARHR, CVARHR) changes. Setting this bit to1 does not have any consequence for ADE7854. When this bit is set to 1, it enables an interrupt when Bit 30 of any one of the fundamental reactive energy registers (AFVARHR, BFVARHR, or CFVARHR) changes. Setting this bit to1 does not have any consequence for ADE7854, ADE7858, and ADE7868. Rev. E| Page 82 of 96 ADE7854/ADE7858/ADE7868/ADE7878 Bit Location 4 Bit Mnemonic VAEHF Default Value 0 5 LENERGY 0 6 REVAPA 0 7 REVAPB 0 8 REVAPC 0 9 REVPSUM1 0 10 REVRPA 0 11 REVRPB 0 12 REVRPC 0 13 REVPSUM2 0 14 CF1 15 CF2 16 CF3 17 DREADY 0 18 REVPSUM3 0 31:19 Reserved 00 0000 0000 0000 Description When this bit is set to 1, it enables an interrupt when Bit 30 of any one of the apparent energy registers (AVAHR, BVAHR, or CVAHR) changes. When this bit is set to 1, in line energy accumulation mode, it enables an interrupt at the end of an integration over an integer number of half line cycles set in the LINECYC register. When this bit is set to 1, it enables an interrupt when the Phase A active power identified by Bit 6 (REVAPSEL) in the ACCMODE register (total or fundamental) changes sign. When this bit is set to 1, it enables an interrupt when the Phase B active power identified by Bit 6 (REVAPSEL) in the ACCMODE register (total or fundamental) changes sign. When this bit is set to 1, it enables an interrupt when the Phase C active power identified by Bit 6 (REVAPSEL) in the ACCMODE register (total or fundamental) changes sign. When this bit is set to 1, it enables an interrupt when the sum of all phase powers in the CF1 datapath changes sign. When this bit is set to 1, it enables an interrupt when the Phase A reactive power identified by Bit 7 (REVRPSEL) in the ACCMODE register (total or fundamental) changes sign. Setting this bit to1 does not have any consequence for ADE7854. When this bit is set to 1, it enables an interrupt when the Phase B reactive power identified by Bit 7 (REVRPSEL) in the ACCMODE register (total or fundamental) changes sign. Setting this bit to1 does not have any consequence for ADE7854. When this bit is set to 1, it enables an interrupt when the Phase C reactive power identified by Bit 7 (REVRPSEL) in the ACCMODE register (total or fundamental) changes sign. Setting this bit to1 does not have any consequence for ADE7854. When this bit is set to 1, it enables an interrupt when the sum of all phase powers in the CF2 datapath changes sign. When this bit is set to 1, it enables an interrupt when a high-to-low transition occurs at the CF1 pin, that is, an active low pulse is generated. The interrupt can be enabled even if the CF1 output is disabled by setting Bit 9 (CF1DIS) to 1 in the CFMODE register. The type of power used at the CF1 pin is determined by Bits[2:0] (CF1SEL[2:0]) in the CFMODE register (see Table 45). When this bit is set to 1, it enables an interrupt when a high-to-low transition occurs at CF2 pin, that is, an active low pulse is generated. The interrupt may be enabled even if the CF2 output is disabled by setting Bit 10 (CF2DIS) to 1 in the CFMODE register. The type of power used at the CF2 pin is determined by Bits[5:3] (CF2SEL[2:0]) in the CFMODE register (see Table 45). When this bit is set to 1, it enables an interrupt when a high to low transition occurs at CF3 pin, that is, an active low pulse is generated. The interrupt may be enabled even if the CF3 output is disabled by setting Bit 11 (CF3DIS) to 1 in the CFMODE register. The type of power used at the CF3 pin is determined by Bits[8:6] (CF3SEL[2:0]) in the CFMODE register (see Table 45). When this bit is set to 1, it enables an interrupt when all periodical (at 8 kHz rate) DSP computations finish. When this bit is set to 1, it enables an interrupt when the sum of all phase powers in the CF3 datapath changes sign. Reserved. These bits do not manage any functionality. Table 40. MASK1 Register (Address 0xE50B) Bit Location 0 Bit Mnemonic NLOAD Default Value 0 1 FNLOAD 0 2 VANLOAD 0 3 ZXTOVA 0 4 ZXTOVB 0 Description When this bit is set to 1, it enables an interrupt when at least one phase enters no load condition based on total active and reactive powers. When this bit is set to 1, it enables an interrupt when at least one phase enters no load condition based on fundamental active and reactive powers. Setting this bit to 1 does not have any consequence for ADE7854, ADE7858, and ADE7868. When this bit is set to 1, it enables an interrupt when at least one phase enters no load condition based on apparent power. When this bit is set to 1, it enables an interrupt when a zero crossing on Phase A voltage is missing. When this bit is set to 1, it enables an interrupt when a zero crossing on Phase B voltage is missing. Rev. E| Page 83 of 96 ADE7854/ADE7858/ADE7868/ADE7878 Bit Location 5 Bit Mnemonic ZXTOVC Default Value 0 6 ZXTOIA 0 7 ZXTOIB 0 8 ZXTOIC 0 9 ZXVA 0 10 ZXVB 0 11 ZXVC 0 12 ZXIA 0 13 ZXIB 0 14 ZXIC 0 15 RSTDONE 0 16 SAG 0 17 OI 0 18 OV 0 19 SEQERR 0 20 MISMTCH 0 22:21 23 Reserved PKI 00 0 24 PKV 0 31:25 Reserved 000 0000 Description When this bit is set to 1, it enables an interrupt when a zero crossing on Phase C voltage is missing. When this bit is set to 1, it enables an interrupt when a zero crossing on Phase A current is missing. When this bit is set to 1, it enables an interrupt when a zero crossing on Phase B current is missing. When this bit is set to 1, it enables an interrupt when a zero crossing on Phase C current is missing. When this bit is set to 1, it enables an interrupt when a zero crossing is detected on Phase A voltage. When this bit is set to 1, it enables an interrupt when a zero crossing is detected on Phase B voltage. When this bit is set to 1, it enables an interrupt when a zero crossing is detected on Phase C voltage. When this bit is set to 1, it enables an interrupt when a zero crossing is detected on Phase A current. When this bit is set to 1, it enables an interrupt when a zero crossing is detected on Phase B current. When this bit is set to 1, it enables an interrupt when a zero crossing is detected on Phase C current. Because the RSTDONE interrupt cannot be disabled, this bit does not have any functionality attached. It can be set to 1 or cleared to 0 without having any effect. When this bit is set to 1, it enables an interrupt when a SAG event occurs on one of the phases indicated by Bits[14:12] (VSPHASE[x]) in the PHSTATUS register (see Table 41). When this bit is set to 1, it enables an interrupt when an overcurrent event occurs on one of the phases indicated by Bits[5:3] (OIPHASE[x]) in the PHSTATUS register (see Table 41). When this bit is set to 1, it enables an interrupt when an overvoltage event occurs on one of the phases indicated by Bits[11:9] (OVPHASE[x]) in the PHSTATUS register (see Table 41). When this bit is set to 1, it enables an interrupt when a negative-to-positive zero crossing on Phase A voltage is not followed by a negative-to-positive zero crossing on Phase B voltage, but by a negative-to-positive zero crossing on Phase C voltage. When this bit is set to 1, it enables an interrupt when ISUM - INWV > ISUMLVL is greater than the value indicated in ISUMLVL register. Setting this bit to1 does not have any consequence for ADE7854 and ADE7858. Reserved. These bits do not manage any functionality. When this bit is set to 1, it enables an interrupt when the period used to detect the peak value in the current channel has ended. When this bit is set to 1, it enables an interrupt when the period used to detect the peak value in the voltage channel has ended. Reserved. These bits do not manage any functionality. Table 41. PHSTATUS Register (Address 0xE600) Bit Location 2:0 3 4 5 8:6 9 10 11 12 13 Bit Mnemonic Reserved OIPHASE[0] OIPHASE[1] OIPHASE[2] Reserved OVPHASE[0] OVPHASE[1] OVPHASE[2] VSPHASE[0] VSPHASE[1] Default Value 000 0 0 0 000 0 0 0 0 0 Description Reserved. These bits are always 0. When this bit is set to 1, Phase A current generates Bit 17 (OI) in the STATUS1 register. When this bit is set to 1, Phase B current generates Bit 17 (OI) in the STATUS1 register. When this bit is set to 1, Phase C current generates Bit 17 (OI) in the STATUS1 register. Reserved. These bits are always 0. When this bit is set to 1, Phase A voltage generates Bit 18 (OV) in the STATUS1 register. When this bit is set to 1, Phase B voltage generates Bit 18 (OV) in the STATUS1 register. When this bit is set to 1, Phase C voltage generates Bit 18 (OV) in the STATUS1 register. When this bit is set to 1, Phase A voltage generates Bit 16 (SAG) in the STATUS1 register. When this bit is set to 1, Phase B voltage generates Bit 16 (SAG) in the STATUS1 register. Rev. E| Page 84 of 96 ADE7854/ADE7858/ADE7868/ADE7878 Bit Location 14 15 Bit Mnemonic VSPHASE[2] Reserved Default Value 0 0 Description When this bit is set to 1, Phase C voltage generates Bit16 (SAG) in the STATUS1 register. Reserved. This bit is always 0. Table 42. PHNOLOAD Register (Address 0xE608) Bit Location 0 Bit Mnemonic NLPHASE[0] Default Value 0 1 NLPHASE[1] 0 2 NLPHASE[2] 0 3 FNLPHASE[0] 0 4 FNLPHASE[1] 0 5 FNLPHASE[2] 0 6 VANLPHASE[0] 0 7 VANLPHASE[1] 0 8 VANLPHASE[2] 0 15:9 Reserved 000 0000 Description 0: Phase A is out of no load condition based on total active/reactive powers. 1: Phase A is in no load condition based on total active/reactive powers. Bit set together with Bit 0 (NLOAD) in the STATUS1 register. The ADE7854 no load condition is based only on the total active powers. 0: Phase B is out of no load condition based on total active/reactive powers. 1: Phase B is in no load condition based on total active/reactive powers. Bit set together with Bit 0 (NLOAD) in the STATUS1 register. The ADE7854 no load condition is based only on the total active powers. 0: Phase C is out of no load condition based on total active/reactive powers. 1: Phase C is in no load condition based on total active/reactive powers. Bit set together with Bit 0 (NLOAD) in the STATUS1 register. The ADE7854 no load condition is based only on the total active powers. 0: Phase A is out of no load condition based on fundamental active/reactive powers. This bit is always 0 for ADE7854, ADE7858, and ADE7868. 1: Phase A is in no load condition based on fundamental active/reactive powers. This bit is set together with Bit 1 (FNLOAD) in STATUS1. 0: Phase B is out of no load condition based on fundamental active/reactive powers. This bit is always 0 for ADE7854, ADE7858, and ADE7868. 1: Phase B is in no load condition based on fundamental active/reactive powers. This bit is set together with Bit 1 (FNLOAD) in STATUS1. 0: Phase C is out of no load condition based on fundamental active/reactive powers. This bit is always 0 for ADE7854, ADE7858, and ADE7868. 1: Phase C is in no load condition based on fundamental active/reactive powers. This bit is set together with Bit 1 (FNLOAD) in STATUS1. 0: Phase A is out of no load condition based on apparent power. 1: Phase A is in no load condition based on apparent power. Bit set together with Bit 2 (VANLOAD) in the STATUS1 register. 0: Phase B is out of no load condition based on apparent power. 1: Phase B is in no load condition based on apparent power. Bit set together with Bit 2 (VANLOAD) in the STATUS1 register. 0: Phase C is out of no load condition based on apparent power. 1: Phase C is in no load condition based on apparent power. Bit set together with Bit 2 (VANLOAD) in the STATUS1 register. Reserved. These bits are always 0. Table 43. COMPMODE Register (Address 0xE60E) Bit Location 0 Bit Mnemonic TERMSEL1[0] Default Value 1 1 2 3 TERMSEL1[1] TERMSEL1[2] TERMSEL2[0] 1 1 1 4 5 6 TERMSEL2[1] TERMSEL2[2] TERMSEL3[0] 1 1 1 7 TERMSEL3[1] 1 Description Setting all TERMSEL1[2:0] to 1 signifies the sum of all three phases is included in the CF1 output. Phase A is included in the CF1 outputs calculations. Phase B is included in the CF1 outputs calculations. Phase C is included in the CF1 outputs calculations. Setting all TERMSEL2[2:0] to 1 signifies the sum of all three phases is included in the CF2 output. Phase A is included in the CF2 outputs calculations. Phase B is included in the CF2 outputs calculations. Phase C is included in the CF2 outputs calculations. Setting all TERMSEL3[2:0] to 1 signifies the sum of all three phases is included in the CF3 output. Phase A is included in the CF3 outputs calculations. Phase B is included in the CF3 outputs calculations. Rev. E| Page 85 of 96 ADE7854/ADE7858/ADE7868/ADE7878 Bit Location 8 10:9 Bit Mnemonic TERMSEL3[2] ANGLESEL[1:0] Default Value 1 00 11 VNOMAEN 0 12 VNOMBEN 0 13 VNOMCEN 0 14 SELFREQ 0 15 Reserved 0 Description Phase C is included in the CF3 outputs calculations. 00: the angles between phase voltages and phase currents are measured. 01: the angles between phase voltages are measured. 10: the angles between phase currents are measured. 11: no angles are measured. When this bit is 0, the apparent power on Phase A is computed regularly. When this bit is 1, the apparent power on Phase A is computed using VNOM register instead of regular measured rms phase voltage. When this bit is 0, the apparent power on Phase B is computed regularly. When this bit is 1, the apparent power on Phase B is computed using VNOM register instead of regular measured rms phase voltage. When this bit is 0, the apparent power on Phase C is computed regularly. When this bit is 1, the apparent power on Phase C is computed using VNOM register instead of regular measured rms phase voltage. When the ADE7878 is connected to 50 Hz networks, this bit should be cleared to 0 (default value). When the ADE7878 is connected to 60 Hz networks, this bit should be set to 1. This bit does not have any consequence for ADE7854, ADE7858, and ADE7868. This bit is 0 by default and it does not manage any functionality. Table 44. Gain Register (Address 0xE60F) Bit Location 2:0 Bit Mnemonic PGA1[2:0] Default Value 000 5:3 PGA2[2:0] 000 8:6 PGA3[2:0] 000 15:9 Reserved 000 0000 Description Phase currents gain selection. 000: gain = 1. 001: gain = 2. 010: gain = 4. 011: gain = 8. 100: gain = 16. 101, 110, 111: reserved. When set, the ADE7854/ADE7858/ADE7868/ADE7878 behave like PGA1[2:0] = 000. Neutral current gain selection. 000: gain = 1. These bits are always 000 for ADE7854 and ADE7858. 001: gain = 2. 010: gain = 4. 011: gain = 8. 100: gain = 16. 101, 110, 111: reserved. When set, the ADE7868/ADE7878 behave like PGA2[2:0] = 000. Phase voltages gain selection. 000: gain = 1. 001: gain = 2. 010: gain = 4. 011: gain = 8. 100: gain = 16. 101, 110, 111: reserved. When set, the ADE7854/ADE7858/ADE7868/ADE7878 behave like PGA3[2:0] = 000. Reserved. These bits do not manage any functionality. Rev. E| Page 86 of 96 ADE7854/ADE7858/ADE7868/ADE7878 Table 45. CFMODE Register (Address 0xE610) Bit Location 2:0 Bit Mnemonic CF1SEL[2:0] Default Value 000 5:3 CF2SEL[2:0] 001 8:6 CF3SEL[2:0] 010 9 CF1DIS 1 10 CF2DIS 1 11 CF3DIS 1 Description 000: the CF1 frequency is proportional to the sum of total active powers on each phase identified by Bits[2:0] (TERMSEL1[x]) in the COMPMODE register. 001: the CF1 frequency is proportional to the sum of total reactive powers on each phase identified by Bits[2:0] (TERMSEL1[x]) in the COMPMODE register. This condition does not have any consequence for the ADE7854. 010: the CF1 frequency is proportional to the sum of apparent powers on each phase identified by Bits[2:0] (TERMSEL1[x]) in the COMPMODE register. 011: the CF1 frequency is proportional to the sum of fundamental active powers on each phase identified by Bits[2:0] (TERMSEL1[x]) in the COMPMODE register. This condition does not have any consequence for the ADE7854, ADE7858, and ADE7868. 100: the CF1 frequency is proportional to the sum of fundamental reactive powers on each phase identified by Bits[2:0] (TERMSEL1[x]) in the COMPMODE register. This condition does not have any consequence for the ADE7854, ADE7858, and ADE7868. 101, 110, 111: reserved. When set, the CF1 signal is not generated. 000: the CF2 frequency is proportional to the sum of total active powers on each phase identified by Bits[5:3] (TERMSEL2[x]) in the COMPMODE register. 001: the CF2 frequency is proportional to the sum of total reactive powers on each phase identified by Bits[5:3] (TERMSEL2[x]) in the COMPMODE register. This condition does not have any consequence for the ADE7854. 010: the CF2 frequency is proportional to the sum of apparent powers on each phase identified by Bits[5:3] (TERMSEL2[x]) in the COMPMODE register. 011: the CF2 frequency is proportional to the sum of fundamental active powers on each phase identified by Bits[5:3] (TERMSEL2[x]) in the COMPMODE register. This condition does not have any consequence for the ADE7854, ADE7858, and ADE7868. 100: the CF2 frequency is proportional to the sum of fundamental reactive powers on each phase identified by Bits[5:3] (TERMSEL2[x]) in the COMPMODE register. This condition does not have any consequence for the ADE7854, ADE7858, and ADE7868. 101,110,111: reserved. When set, the CF2 signal is not generated. 000: the CF3 frequency is proportional to the sum of total active powers on each phase identified by Bits[8:6] (TERMSEL3[x]) in the COMPMODE register. 001: the CF3 frequency is proportional to the sum of total reactive powers on each phase identified by Bits[8:6] (TERMSEL3[x]) in the COMPMODE register. This condition does not have any consequence for the ADE7854. 010: the CF3 frequency is proportional to the sum of apparent powers on each phase identified by Bits[8:6] (TERMSEL3[x]) in the COMPMODE register. 011: CF3 frequency is proportional to the sum of fundamental active powers on each phase identified by Bits[8:6] (TERMSEL3[x]) in the COMPMODE register. This condition does not have any consequence for the ADE7854, ADE7858, and ADE7868. 100: CF3 frequency is proportional to the sum of fundamental reactive powers on each phase identified by Bits[8:6] (TERMSEL3[x]) in the COMPMODE register. This condition does not have any consequence for the ADE7854, ADE7858, and ADE7868. 101,110,111: reserved. When set, the CF3 signal is not generated. When this bit is set to 1, the CF1 output is disabled. The respective digital to frequency converter remains enabled even if CF1DIS = 1. When this bit is set to 0, the CF1 output is enabled. When this bit is set to 1, the CF2 output is disabled. The respective digital to frequency converter remains enabled even if CF2DIS = 1. When this bit is set to 0, the CF2 output is enabled. When this bit is set to 1, the CF3 output is disabled. The respective digital to frequency converter remains enabled even if CF3DIS = 1. When this bit is set to 0, the CF3 output is enabled. Rev. E| Page 87 of 96 ADE7854/ADE7858/ADE7868/ADE7878 Bit Location 12 Bit Mnemonic CF1LATCH Default Value 0 13 CF2LATCH 0 14 CF3LATCH 0 15 Reserved 0 Description When this bit is set to 1, the content of the corresponding energy registers is latched when a CF1 pulse is generated. See the Synchronizing Energy Registers with CFx Outputs section. When this bit is set to 1, the content of the corresponding energy registers is latched when a CF2 pulse is generated. See the Synchronizing Energy Registers with CFx Outputs section. When this bit is set to 1, the content of the corresponding energy registers is latched when a CF3 pulse is generated. See the Synchronizing Energy Registers with CFx Outputs section. Reserved. This bit does not manage any functionality. Table 46. APHCAL, BPHCAL, CPHCAL Registers (Address 0xE614, Address 0xE615, Address 0xE616) Bit Location 9:0 Bit Mnemonic PHCALVAL Default Value 0000000000 15:10 Reserved 000000 Description If current channel compensation is necessary, these bits can vary only between 0 and 383. If voltage channel compensation is necessary, these bits can vary only between 512 and 575. If the PHCALVAL bits are set with numbers between 384 and 511, the compensation behaves like PHCALVAL set between 256 and 383. If the PHCALVAL bits are set with numbers between 576 and 1023, the compensation behaves like PHCALVAL bits set between 384 and 511. Reserved. These bits do not manage any functionality. Table 47. PHSIGN Register (Address 0xE617) Bit Location 0 Bit Mnemonic AWSIGN Default Value 0 1 BWSIGN 0 2 CWSIGN 0 3 SUM1SIGN 0 4 AVARSIGN 0 5 BVARSIGN 0 6 CVARSIGN 0 7 SUM2SIGN 0 Description 0: if the active power identified by Bit 6 (REVAPSEL) in the ACCMODE register (total of fundamental) on Phase A is positive. 1: if the active power identified by Bit 6 (REVAPSEL) in the ACCMODE register (total of fundamental) on Phase A is negative. 0: if the active power identified by Bit 6 (REVAPSEL) in the ACCMODE register (total of fundamental) on Phase B is positive. 1: if the active power identified by Bit 6 (REVAPSEL) in the ACCMODE register (total of fundamental) on Phase B is negative. 0: if the active power identified by Bit 6 (REVAPSEL) in the ACCMODE register (total of fundamental) on Phase C is positive. 1: if the active power identified by Bit 6 (REVAPSEL) bit in the ACCMODE register (total of fundamental) on Phase C is negative. 0: if the sum of all phase powers in the CF1 datapath is positive. 1: if the sum of all phase powers in the CF1 datapath is negative. Phase powers in the CF1 datapath are identified by Bits[2:0] (TERMSEL1[x]) of the COMPMODE register and by Bits[2:0] (CF1SEL[x]) of the CFMODE register. 0: if the reactive power identified by Bit 7 (REVRPSEL) in the ACCMODE register (total of fundamental) on Phase A is positive. This bit is always 0 for ADE7854. 1: if the reactive power identified by Bit 7 (REVRPSEL) in the ACCMODE register (total of fundamental) on Phase A is negative. 0: if the reactive power identified by Bit 7 (REVRPSEL) in the ACCMODE register (total of fundamental) on Phase B is positive. This bit is always 0 for ADE7854. 1: if the reactive power identified by Bit 7 (REVRPSEL) in the ACCMODE register (total of fundamental) on Phase B is negative. 0: if the reactive power identified by Bit 7 (REVRPSEL) in the ACCMODE register (total of fundamental) on Phase C is positive. This bit is always 0 for ADE7854. 1: if the reactive power identified by Bit 7 (REVRPSEL) in the ACCMODE register (total of fundamental) on Phase C is negative. 0: if the sum of all phase powers in the CF2 datapath is positive. 1: if the sum of all phase powers in the CF2 datapath is negative. Phase powers in the CF2 datapath are identified by Bits[5:3] (TERMSEL2[x]) of the COMPMODE register and by Bits[5:3] (CF2SEL[x]) of the CFMODE register. Rev. E| Page 88 of 96 ADE7854/ADE7858/ADE7868/ADE7878 Bit Location 8 Bit Mnemonic SUM3SIGN Default Value 0 15:9 Reserved 000 0000 Description 0: if the sum of all phase powers in the CF3 datapath is positive. 1: if the sum of all phase powers in the CF3 datapath is negative. Phase powers in the CF3 datapath are identified by Bits[8:6] (TERMSEL3[x]) of the COMPMODE register and by Bits[8:6] (CF3SEL[x]) of the CFMODE register. Reserved. These bits are always 0. Table 48. CONFIG Register (Address 0xE618) Bit Location 0 Bit Mnemonic INTEN Default Value 0 2:1 3 Reserved SWAP 00 0 4 MOD1SHORT 0 5 MOD2SHORT 0 6 HSDCEN 0 7 9:8 SWRST VTOIA[1:0] 0 00 11:10 VTOIB[1:0] 00 13:12 VTOIC[1:0] 00 15:14 Reserved 0 Description Integrator enable. When this bit is set to 1, the internal digital integrator is enabled for use in meters utilizing Rogowski coils on all 3-phase and neutral current inputs. When this bit is cleared to 0, the internal digital integrator is disabled. Reserved. These bits do not manage any functionality. When this bit is set to 1, the voltage channel outputs are swapped with the current channel outputs. Thus, the current channel information is present in the voltage channel registers and vice versa. When this bit is set to 1, the voltage channel ADCs behave as if the voltage inputs were put to ground. When this bit is set to 1, the current channel ADCs behave as if the voltage inputs were put to ground. When this bit is set to 1, the HSDC serial port is enabled and HSCLK functionality is chosen at CF3/HSCLK pin. When this bit is cleared to 0, HSDC is disabled and CF3 functionality is chosen at CF3/HSCLK pin. When this bit is set to 1, a software reset is initiated. These bits decide what phase voltage is considered together with Phase A current in the power path. 00 = Phase A voltage. 01 = Phase B voltage. 10 = Phase C voltage. 11 = reserved. When set, the ADE7854/ADE7858/ADE7868/ADE7878 behave like VTOIA[1:0] = 00. These bits decide what phase voltage is considered together with Phase B current in the power path. 00 = Phase B voltage. 01 = Phase C voltage. 10 = Phase A voltage. 11 = reserved. When set, the ADE7854/ADE7858/ADE7868/ADE7878 behave like VTOIB[1:0] = 00. These bits decide what phase voltage is considered together with Phase C current in the power path. 00 = Phase C voltage. 01 = Phase A voltage. 10 = Phase B voltage. 11 = reserved. When set, the ADE7854/ADE7858/ADE7868/ADE7878 behave like VTOIC[1:0] = 00. Reserved. These bits do not manage any functionality. Rev. E| Page 89 of 96 ADE7854/ADE7858/ADE7868/ADE7878 Table 49. MMODE Register (Address 0xE700) Bit Location 1:0 Bit Mnemonic PERSEL[1:0] Default Value 00 2 PEAKSEL[0] 1 3 4 7:5 PEAKSEL[1] PEAKSEL[2] Reserved 1 1 000 Description 00: Phase A selected as the source of the voltage line period measurement. 01: Phase B selected as the source of the voltage line period measurement. 10: Phase C selected as the source of the voltage line period measurement. 11: reserved. When set, the ADE7854/ADE7858/ADE7868/ADE7878 behave like PERSEL[1:0] = 00. PEAKSEL[2:0] bits can all be set to 1 simultaneously to allow peak detection on all three phases simultaneously. If more than one PEAKSEL[2:0] bits are set to 1, then the peak measurement period indicated in the PEAKCYC register decreases accordingly because zero crossings are detected on more than one phase. When this bit is set to 1, Phase A is selected for the voltage and current peak registers. When this bit is set to 1, Phase B is selected for the voltage and current peak registers. When this bit is set to 1, Phase C is selected for the voltage and current peak registers. Reserved. These bits do not manage any functionality. Table 50. ACCMODE Register (Address 0xE701) Bit Location 1:0 Bit Mnemonic WATTACC[1:0] Default Value 00 3:2 VARACC[1:0] 00 5:4 CONSEL[1:0] 00 Description 00: signed accumulation mode of the total and fundamental active powers. Fundamental active powers are available in the ADE7878. 01: reserved. When set, the device behaves like WATTACC[1:0] = 00. 10: reserved. When set, the device behaves like WATTACC[1:0] = 00. 11: absolute accumulation mode of the total and fundamental active powers. 00: signed accumulation of the total and fundamental reactive powers. Total reactive powers are available in the ADE7858, ADE7868, and ADE7878. Fundamental reactive powers are available in the ADE7878. These bits are always 00 for the ADE7854. 01: reserved. When set, the device behaves like VARACC[1:0] = 00. 10: the total and fundamental reactive powers are accumulated, depending on the sign of the total and fundamental active power: if the active power is positive, the reactive power is accumulated as is, whereas if the active power is negative, the reactive power is accumulated with reversed sign. 11: reserved. When set, the device behave like VARACC[1:0] = 00. These bits select the inputs to the energy accumulation registers. IA', IB', and IC' are IA, IB, and IC shifted respectively by -90. See Table 51. 00: 3-phase four wires with three voltage sensors. 01: 3-phase three wires delta connection. 10: 3-phase four wires with two voltage sensors. 11: 3-phase four wires delta connection. 6 REVAPSEL 0 7 REVRPSEL 0 0: The total active power on each phase is used to trigger a bit in the STATUS0 register as follows: on Phase A triggers Bit 6 (REVAPA), on Phase B triggers Bit 7 (REVAPB), and on Phase C triggers Bit 8 (REVAPC). This bit is always 0 for the ADE7854, ADE7858, and ADE7868. 1: The fundamental active power on each phase is used to trigger a bit in the STATUS0 register as follows: on Phase A triggers Bit 6 (REVAPA), on Phase B triggers Bit 7 (REVAPB), and on Phase C triggers Bit 8 (REVAPC). 0: The total active power on each phase is used to trigger a bit in the STATUS0 register as follows: on Phase A triggers Bit 10 (REVRPA), on Phase B triggers Bit 11 (REVRPB), and on Phase C triggers Bit 12 (REVRPC). This bit is always 0 for the ADE7854, ADE7858, and ADE7868. 1: The fundamental active power on each phase is used to trigger a bit in the STATUS0 register as follows: on Phase A triggers Bit 10 (REVRPA), on Phase B triggers Bit 11 (REVRPB), and on Phase C triggers Bit 12 (REVRPC). Rev. E| Page 90 of 96 ADE7854/ADE7858/ADE7868/ADE7878 Table 51. CONSEL[1:0] Bits in Energy Registers Energy Registers AWATTHR, AFWATTHR BWATTHR, BFWATTHR CONSEL[1:0] = 00 VA x IA VB x IB CONSEL[1:0] = 01 VA x IA 0 CWATTHR, CFWATTHR AVARHR, AFVARHR BVARHR, BFVARHR VC x IC VA x IA' VB x IB' VC x IC VA x IA' 0 CVARHR, CFVARHR AVAHR BVAHR CVAHR VC x IC' VA rms x IA rms VB rms x IB rms VC rms x IC rms VC x IC' VA rms x IA rms 0 VC rms x IC rms CONSEL[1:0] = 10 VA x IA VB = -VA - VC VB x IB VC x IC VA x IA' VB = -VA - VC VB x IB' VC x IC' VA rms x IA rms VB rms x IB rms VC rms x IC rms CONSEL[1:0] = 11 VA x IA VB = -VA VB x IB VC x IC VA x IA' VB = -VA VB x IB' VC x IC' VA rms x IA rms VB rms x IB rms VC rms x IC rms Table 52. LCYCMODE Register (Address 0xE702) Bit Location 0 Bit Mnemonic LWATT Default Value 0 1 LVAR 0 2 LVA 0 3 ZXSEL[0] 1 4 ZXSEL[1] 1 5 ZXSEL[2] 1 6 RSTREAD 1 7 Reserved 0 Description 0: the watt-hour accumulation registers (AWATTHR, BWATTHR, CWATTHR, AFWATTHR, BFWATTHR, and CFWATTHR) are placed in regular accumulation mode. 1: the watt-hour accumulation registers (AWATTHR, BWATTHR, CWATTHR, AFWATTHR, BFWATTHR, and CFWATTHR) are placed into line cycle accumulation mode. 0: the var-hour accumulation registers (AVARHR, BVARHR, and CVARHR) are placed in regular accumulation mode. This bit is always 0 for the ADE7854. 1: the var-hour accumulation registers (AVARHR, BVARHR, and CVARHR) are placed into linecycle accumulation mode. 0: the VA-hour accumulation registers (AVAHR, BVAHR, and CVAHR) are placed in regular accumulation mode. 1: the VA-hour accumulation registers (AVAHR, BVAHR, and CVAHR) are placed into line-cycle accumulation mode. 0: Phase A is not selected for zero-crossings counts in the line cycle accumulation mode. 1: Phase A is selected for zero-crossings counts in the line cycle accumulation mode. If more than one phase is selected for zero-crossing detection, the accumulation time is shortened accordingly. 0: Phase B is not selected for zero-crossings counts in the line cycle accumulation mode. 1: Phase B is selected for zero-crossings counts in the line cycle accumulation mode. 0: Phase C is not selected for zero-crossings counts in the line cycle accumulation mode. 1: Phase C is selected for zero-crossings counts in the line cycle accumulation mode. 0: read-with-reset of all energy registers is disabled. Clear this bit to 0 when Bits[2:0] (LWATT, LVAR, and LVA) are set to 1. 1: enables read-with-reset of all xWATTHR, xVARHR, xVAHR, xFWATTHR, and xFVARHR registers. This means a read of those registers resets them to 0. Reserved. This bit does not manage any functionality. Table 53. HSDC_CFG Register (Address 0xE706) Bit Location 0 Bit Mnemonic HCLK Default Value 0 1 HSIZE 0 2 HGAP 0 Description 0: HSCLK is 8 MHz. 1: HSCLK is 4 MHz. 0: HSDC transmits the 32-bit registers in 32-bit packages, most significant bit first. 1: HSDC transmits the 32-bit registers in 8-bit packages, most significant bit first. 0: no gap is introduced between packages. 1: a gap of seven HCLK cycles is introduced between packages. Rev. E| Page 91 of 96 ADE7854/ADE7858/ADE7868/ADE7878 Bit Location 4:3 Bit Mnemonic HXFER[1:0] Default Value 00 5 HSAPOL 0 7:6 Reserved 00 Description 00 = for ADE7854, HSDC transmits sixteen 32-bit words in the following order: IAWV, VAWV, IBWV, VBWV, ICWV, and VCWV, one 32-bit word equal to 0, AVA, BVA, CVA, AWATT, BWATT, and CWATT, three 32-bit words equal to 0. For ADE7858, HSDC transmits sixteen 32-bit words in the following order: IAWV, VAWV, IBWV, VBWV, ICWV, and VCWV, one 32-bit word equal to 0, AVA, BVA, CVA, AWATT, BWATT, CWATT, AVAR, BVAR, and CVAR. For the ADE7868 and ADE7878, HSDC transmits sixteen 32-bit words in the following order: IAWV, VAWV, IBWV, VBWV, ICWV, VCWV, INWV, AVA, BVA, CVA, AWATT, BWATT, CWATT, AVAR, BVAR, and CVAR. 01 = for the ADE7854 and ADE7858, HSDC transmits six instantaneous values of currents and voltages: IAWV, VAWV, IBWV, VBWV, ICWV, and VCWV, and one 32-bit word equal to 0. For the ADE7868 and ADE7878, HSDC transmits seven instantaneous values of currents and voltages: IAWV, VAWV, IBWV, VBWV, ICWV, VCWV, and INWV. 10 = for the ADE7854, HSDC transmits six instantaneous values of phase powers: AVA, BVA, CVA, AWATT, BWATT, and CWATT and three 32-bit words equal to 0. For the ADE7858, ADE7868, and ADE7878, HSDC transmits nine instantaneous values of phase powers: AVA, BVA, CVA, AWATT, BWATT, CWATT, AVAR, BVAR, and CVAR. 11 = reserved. If set, the ADE7854/ADE7858/ADE7868/ADE7878 behave as if HXFER[1:0] = 00. 0: SS/HSA output pin is active low. 1: SS/HSA output pin is active high. Reserved. These bits do not manage any functionality. Table 54. LPOILVL Register (Address 0xEC00)1 Bit Location 2:0 7:3 1 Bit Mnemonic LPOIL[2:0] LPLINE[4:0] Default Value 111 00000 Description Threshold is put at a value corresponding to full scale multiplied by LPOIL/8. The measurement period is (LPLINE + 1)/50 seconds. The LPOILVL register is available only for the ADE7868 and ADE7878; it is reserved for ADE7854 and ADE7858. Table 55. CONFIG2 Register (Address 0xEC01) Bit Location 0 Bit Mnemonic EXTREFEN Default Value 0 1 I2C_LOCK 0 7:2 Reserved 0 Description When this bit is 0, it signifies that the internal voltage reference is used in the ADCs. When this bit is 1, an external reference is connected to the Pin 17 REFIN/OUT. When this bit is 0, the SS/HSA pin can be toggled three times to activate the SPI port. If I2C is the active serial port, this bit must be set to 1 to lock it in. From this moment on, spurious toggling of the SS/HSA pin and an eventual switch into using the SPI port is no longer possible. If SPI is the active serial port, any write to CONFIG2 register locks the port. From this moment on, a switch into using I2C port is no longer possible. Once locked, the serial port choice is maintained when the ADE7854/ADE7858/ADE7868/ADE7878 change PSMx power modes. Reserved. These bits do not manage any functionality. Rev. E| Page 92 of 96 ADE7854/ADE7858/ADE7868/ADE7878 OUTLINE DIMENSIONS 0.30 0.23 0.18 31 40 30 0.50 BSC 1 0.80 0.75 0.70 0.45 0.40 0.35 10 11 20 0.05 MAX 0.02 NOM COPLANARITY 0.08 0.20 REF SEATING PLANE 4.45 4.30 SQ 4.25 EXPOSED PAD 21 TOP VIEW PIN 1 INDICATOR BOTTOM VIEW 0.25 MIN FOR PROPER CONNECTION OF THE EXPOSED PAD, REFER TO THE PIN CONFIGURATION AND FUNCTION DESCRIPTIONS SECTION OF THIS DATA SHEET. COMPLIANT TO JEDEC STANDARDS MO-220-WJJD. 111808-A PIN 1 INDICATOR 6.10 6.00 SQ 5.90 Figure 90. 40-Lead Lead Frame Chip Scale Package [LFCSP_WQ] 6 mm x 6 mm Body, Very Very Thin Quad (CP-40-10) Dimensions shown in millimeters ORDERING GUIDE Model 1 ADE7854ACPZ ADE7854ACPZ-RL ADE7858ACPZ ADE7858ACPZ-RL ADE7868ACPZ ADE7868ACPZ-RL ADE7878ACPZ ADE7878ACPZ-RL 1 Temperature Range -40C to +85C -40C to +85C -40C to +85C -40C to +85C -40C to +85C -40C to +85C -40C to +85C -40C to +85C Package Description 40-Lead LFCSP_WQ 40-Lead LFCSP_WQ, 13" Tape and Reel 40-Lead LFCSP_WQ 40-Lead LFCSP_WQ, 13" Tape and Reel 40-Lead LFCSP_WQ 40-Lead LFCSP_WQ, 13" Tape and Reel 40-Lead LFCSP_WQ 40-Lead LFCSP_WQ, 13" Tape and Reel Z = RoHS Compliant Part. Rev. E| Page 93 of 96 Package Option CP-40-10 CP-40-10 CP-40-10 CP-40-10 CP-40-10 CP-40-10 CP-40-10 CP-40-10 ADE7854/ADE7858/ADE7868/ADE7878 NOTES Rev. E| Page 94 of 96 ADE7854/ADE7858/ADE7868/ADE7878 NOTES Rev. E| Page 95 of 96 ADE7854/ADE7858/ADE7868/ADE7878 NOTES I2C refers to a communications protocol originally developed by Philips Semiconductors (now NXP Semiconductors). (c)2010-2011 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective owners. D08510-0-4/11(E) Rev. E| Page 96 of 96