PSIBAR(R) CVD types 1200 Series / 1600 Series - OEM Transducers Featuring Exceptional Proof Pressure and Stability Specifications Gauge, Vacuum, and Compound Pressure Models General Purpose and Wash down Enclosures High Proof Pressure Achieved by Thicker Diaphragm Construction Voltage and Current Output Models The 1200 Series features stability and toughness via its CVD and ASIC design coupled with a thicker diaphragm. The thicker diaphragm enables these sensors to survive most pressure spikes caused by pump ripple, solenoid valves, etc. The 1600 Series extends the packaging options by providing an all welded stainless steel back end for demanding industrial applications. A modular design allows special ordering of fittings, electrical cables, etc. for OEM applications. The ASIC and CVD technology enables Gems to offer almost any output over any pressure range. Input Pressure Range Proof Pressure Burst Pressure Fatigue Life Performance Supply Voltage Sensitivity Long Term Drift Accuracy Thermal Error Compensated Temperatures Operating Temperatures Zero Tolerance Span Tolerance Response Time Mechanical Configuration Pressure Port Wetted Parts Electrical Connection Enclosure Vibration Acceleration Shock Approvals Weight Vacuum to 6000 psi (400 bar) 4 x Full Scale (FS) (<1% FS Zero Shift) >35 x FS <= 60 psi (4 bar); >20 x FS <= 600 psi (40 bar); >5 x FS <= 6000 psi (400 bar) Designed for more than 100 million FS cycles 0.01% FS/Volt 0.2% FS/year (non-cumulative) 0.5% FS typical 2.0% FS typical -5F to +180F (-20C to +80C) -40F to +260F (-40C to +125C) for elec. codes A, B, C, 1 -5F to +180F (-20C to +80C) for elec. codes 2, D, G, 3 -5F to +125F (-20C to +50C) for elec. code F temperatures >100C supply is limited to 24 VDC 1% of span 1% of span 0.5 ms see ordering chart 17-4 PH Stainless Steel see ordering chart 316 SS, 17-4 PH ss IP65 NEMA 4 for elec. codes A,B,C,D,G,1,2,3 IP67 for elec. codes F IP30 for elec. code "3" with flying leads 70g, peak to peak sinusoidal, 5 to 2000 Hz (Random Vibration: 20 to 200 Hz @ 20g Peak per MIL-STD.-810E Method 514.4) 100g steady acceleration in any direction 0.032% FS/g for 15 psi (1 bar) range decreasing logarithmically to 0.0007% FS/g for 6000 psi (400 bar) range. 20g, 11 ms, per MIL-STD.-810E Method 516.4 Procedure I CE, UR (12 ET, 16 ET Intrinsically safe) approx. 100 grams (additional; cable 75 g/m) Along with the superiority of the CVD strain gauge, Psibar(R) transducers incorporate components to leverage the sensing element's strength. The output is a product with a unique balance of performance and value unmatched in today's pressure sensing market. Thicker diaphragm for handling pulsating pressures - all stainless steel wetted parts. CVD sensor stability and high sensitivity allows use of our thicker diaphragm. 17-4 PH SS sensor beam is laser welded for distortion-free construction. Weldless stainless steel case. ASIC chip is the brains behind the brawn. Programmability provides greater linearity correction than common thermal compensation methods. Visit www.GemsSensors.com for most current information. PRESSURE TRANSDUCERS Specifications RFI/EMI & ESD protection circuit meets and exceeds requirements for CE marking. Protecting against noise, voltage spikes and static discharge. H-7 Individual Specifications Voltage Output units Output Supply Voltage (Vs) Min. Load Resistance Current Output units Output Supply Voltage (Vs) Max. Loop Resistance POWER SUPPLY (-) (+) See ordering chart 1.5 VDC above span to 35 VDC (FS output / 2) Kohms (-) VOLTAGE OUTPUT (+) OUT(+) TRANSDUCER READOUT 4-20 mA (2 wire) 24 VDC, (7-35 VDC) (Vs-7) x 50 ohms POWER SUPPLY (-) (+) Voltage Units Electrical Connection Cable Current Units (4-20 mA) IN+ COM OUT+ EARTH (+) (-) EARTH (+) CURRENT OUTPUT (-) TRANSDUCER READOUT A, B, G "DIN" PIN 1 2 3 4 1 2 4 C "10-6 Bayonet" PIN A C B E A B E D "cable" R BK W DRAIN R BK DRAIN Cable Legend: F "IP 67 cable" R BK W DRAIN R BK DRAIN R = Red 1 "8-4 Bayonet" A C B D A B D BL = Blue 2 "cable" R BK W DRAIN R BK DRAIN 3 "conduit & cable" R BK W DRAIN R BK DRAIN PIN + (-) BK = Black W = White Y = Yellow Electromagnetic Capability Table 1 - Cable Length Meets the requirement for CE marking of EN50081-2 for emissions and EN50082-2 for susceptibility. Test Data: * EN61000-4-2 Electrostatic Discharge. 8kV air discharge, 4kV contact discharge. Unit survived. * ENV50140 Radiated RF Susceptibility. 10V/m, 80MHz-1GHz, 1kHz mod. Maximum recorded output error was <1% * ENV50204 Radiated RF Susceptibility to Mobile Telephones. 10V/m, 900MHz. Maximum recorded output error was <1%. * EN61000-4-4 Fast Burst Transient. 2kV, 5/50ns, 5kHz for 1 minute. Unit survived. * ENV50141 Conducted RF Susceptibility. 10Vms, 1kHz mod, 150kHz - 80MHz. Maximum recorded output error was <1% PRESSURE TRANSDUCERS Monitor Liquid Level with Gems Psibar(R) Pressure Transducers Continuously Monitor Liquid Levels Stainless Steel Wetted Parts are Compatible With Most Fluids Digital Panel Meter Mount Through Top or Side of Tanks Code Length (M) Code Length (M) U No Cable Fitted M 40 D 1 N 50 E 3 P 75 F 5 Q 100 G 10 R 125 H 15 S 150 J 20 4 170 K 25 5 200 L 30 6 225 115 VAC 1/2 NPT Gems Psibar pressure transducers provide a great, cost-effective method for measuring liquid levels. From measuring inventories in process storage tanks to monitoring hot water feed tanks, our design flexibility promotes easy installation, with mounting either through the tank top or from the side. (R) Getting Started... Tank content is be determined from the pressure exerted on the sensor, so you need to know the depth and the specific gravity of the liquid being measured. When these two factors are known, the following equation can be used to determine the pressure range needed to specify an applicable pressure transducer: Pressure in PSI = Liquid Level (in feet) x (Specific Gravity x 0.433) Example: Tank Level: Pressure in PSI = Liquid Level (in feet) x (Specific Gravity x 0.433) Pressure in PSI = 30 x (1.0 x 0.433) Pressure in PSI = 12.99 PSI Using a Psibar Series 1200, 1600, 2200 or 2600 transducer, specify Pressure Range code F15 (0-15 PSI). H-8 IN (+) COMMON 115V Immersible Pressure Transducer Any Gems Transducer Visit www.GemsSensors.com for most current information. Nose Cone Custom 2 NPTM J-Box/Flange Assembly P/N 7800629 CONSULT FACTORY 3-Day PSIBAR(R) CVD types Delivery on Most Transducers Dimensions 1200 Series 1600 Series IP67 Cable (Weatherproof) Mini 4 Pin Code A IP67 or NEMA 4 Cable Code F 1.02 26.0 10-6 or 8-4 Mil-C Connector 10-6 Code C 8-4 Code 1 Code D or 2 1.37 35.0 Large DIN 43650 Plug Code G 2.76 70.1 Conduit Connector with Cable Code 3 1/2" NPT 1.30 33.0 MAX 0.87 22 2.43 MAX 61.60 MAX 1.70 43 MAX 0.59 15 0.79 20 1/2-14 NPT 0.95 24 Code 02 Code 08 MAX 1.70 43 1.07 27.3 MAX 1/4-18 NPT Internal 1/4-18 NPT MAX 1/2" NPT 2.09 MAX 53.2 1.07 MAX 27.3 1/8 NPT Code 3 with length U 2.65 68 MAX MAX Conduit Connector with Flying Leads MAX 1.02 26.0 MAX Code 0H Code 0E (0J with snubber) 7/16 - 20 UNF-2A (SAE J514) 9/16-18 UNF-2A 0.75 19 G 1/8 MAX 0.67 17 MAX Code IP Code 04 G1/4 External Code 09 0.67 17 Code 01 R 1/4 0.79 20 Code 0A How to Order Use the bold characters from the chart below to construct a product code 1600 Output B - 4-20mA C - 1-6V D - 1-11V H - 1-5V 12 ET4 B G A60 01 D 3 D A Performance Code 16 ET4 Cable Length1 U - None D - 1m (3ft) J - 0.5-5.5V R - 0-5V S - 0-10V E - 3m (9ft) F - 5m (16ft) G - 10m (32ft) Apparatus Protection 3 - Amplified Only RFI Protected CE Mark, UR E - Amplified only IS mark (Div. 1 only)4 T - Amplified only IS mark (Div. 1 and 2)4 5 Datum G - Gauge Pressure Range3 - psi F15 - 0-15 F30 - 0-30 F60 - 0-60 G10 - 0-100 G15 - 0-150 G20 - 0-200 G30 - 0-300 G50 - 0-500 G60 - 0-600 H10 - 0-1.000 H15 - 0-1.500 H20 - 0-2.000 H30 - 0-3.000 H40 - 0-4.000 H50 - 0-5.000 H60 - 0-6.000 Vac = -15 psi 1F5 - Vac-0 3F0 - Vac-15 6F0 - Vac-45 1G0 - Vac-135 1G5 - Vac-135 2G0 - Vac-185 3G0 - Vac-285 Pressure Range3 - bar A10 - 0-1 A16 - 0-1.6 A25 - 0-2.5 A40 - 0-4 A60 - 0-6 B10 - 0-10 B16 - 0-16 B25 - 0-25 B40 - 0-40 B60 - 0-60 C10 - 0-100 C16 - 0-160 C25 - 0-250 C40 - 0-400 Vac = -1 bar 1A0 - Vac-0 1A6 - Vac-0.6 2A5 - Vac-1.5 4A0 - Vac-3 6A0 - Vac-5 1B0 - Vac-9 1B6 - Vac-15 2B5 - Vac-24 4B0 - Vac-39 Electrical Connection 1200 Series A - Mini Din with mate B - Mini Din without mate F - IP67 Weatherproof Cable Gland2 2 - NEMA 4 Cable2 1600 Series C - 10-6 Mil C Connector 1 - 8-4 Mil C Connector G - Large DIN 43650 Plug 3 - Conduit Connector with 1 Meter Leads (for cable specify length code) PRESSURE TRANSDUCERS 1600 Series 1200 Pressure Port European Threads 08 - 1/8-27 NPT External 09 - G 1/8 Internal 02 - 1/4-18 NPT External 01 - G 1/4 External 0J - 1/4 NPT External w/snubber 0A - R 1/4 External 0E - 1/4 NPT Internal 0H -1/2-14 NPT External 04 - 7/16-20 External (SAE #4, J514) 1P - 9/16-18 External (SAE #6, J1926-2) IJ - 7/16-20 External (SAE #4, J1926-2) Notes: 1. When electrical connection is cable please select a cable length from Table 1 (opposite page). When electrical connection is DIN or plug style "U" must be specified. 2. Electrical Connections "F" and "2" are 24AWG, Shielded, PVC Cable. 3. Additional Pressure Ranges are available. Please consult factory. 4. Intrinsically safe transducers are available with amplified outputs only. (ETL, entity approved for Class I, Division 1, Groups C & D, hazardous areas; Class I, Divisions 1 and 2, Groups C & D for Electrical Connection Codes -A, -B, -G or -3 only.) 5. Apparatus Protection Code -T is available for Electrical Connection Codes -A, -B, -G or -3 only. Visit www.GemsSensors.com for most current information. H-9