HFD2 SUBMINIATURE DIP RELAY Features File No.:E133481 High sensitive: 150mW Matching standard16 pin IC socket High switching capacity: 125VA / 90W Bifurcated contacts Epoxy sealed for automatic wave soldering and cleaning Single side stable and latching type available File No.: R 50306253 File No.:CQC13002095174(Single side stable) CQC13002095175(Latching) RoHS compliant CONTACT DATA COIL 2C Contact arrangement 100m max. (at 10mA 30mVDC) Contact resistance Contact material see ordering info. Max. switching voltage 250VAC / 220VDC Max. switching current 3A Max. switching power 125VA / 90W 1) Min. applicable load 10mV 10A Mechanical endurance Electrical endurance 2) 1 x 108OPS 4 5 x 10 OPS (2A 30VDC, Ag contact, Resistive load, at 70 C, 1s on 9s off) o Notes: 1) Min. applicable load is reference value. Please perform the confirmation test with the actual load before production since reference value may change according to switching frequencies, environmental conditions and expected contact resistance and reliability. 2) Electric endurance data are collected in one pair CO contact test. 1 coil latching Insulation resistance Between coil & contacts Standard Approx. 150mW Approx. 75mW Approx. 150mW Approx. 200mW Approx. 100mW Approx. 200mW Temperature rise 65K max. COIL DATA at 23 Single side stable Standard type Coil Nominal Pick-up Drop-out Coil Voltage Voltage Resistance Voltage VDC VDC Code x(1 10%) VDC max. min. Max. Voltage VDC 3 2.30 0.3 45 6 005-M 5 3.75 0.5 125 10 006-M 6 4.50 0.6 180 12 009-M 9 6.75 0.9 405 18 012-M 12 9.00 1.2 720 24 1 coil: 1500VAC 1min 015-M 15 11.25 1.5 1125 30 2 coils: 1000VAC 1min 024-M 24 18.0 2.4 2880 48 1000VAC 1min 048-M 48 36.0 4.8 11520 96 1000M (at 500VDC) Between open contacts Operate time (at rated. volt.) 4.5ms max. Release time (at rated. volt.) 3.5ms max. Set time (latching) 4.5ms max. Reset time (latching) 4.5ms max. Ambient temperature -40 Humidity Vibration resistance 2 coils latching Sensitive 003-M CHARACTERISTICS Shock resistance Coil power 1A 125VAC, 2A 30VDC 3A 30VDC Contact rating (Res. load) Dielectric strength Single side stable to 85 Single side stable Sensitive type Coil Pick-up Drop-out Nominal Voltage Voltage Resistance Coil Voltage VDC VDC x(1 10%) Code VDC max. min. Max. Voltage VDC 5% to 85% RH 005-S 5 4.0 0.5 167 11.5 10Hz to 55Hz 1.5mm DA 006-S 6 4.8 0.6 240 13.8 009-S 9 7.2 0.9 540 20.8 012-S 12 9.6 1.2 960 27.7 Functional 490m/s2 Destructive 980m/s2 Termination PCB (DIP) Unit weight Approx. 4.5g 015-S 15 12.0 1.5 1500 34.6 Plastic sealed 024-S 24 19.2 2.4 3840 55.4 Construction Notes: 1) The data shown above are initial values. 2) UL insulation system: Class A HONGFA RELAY ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED 2020 Rev. 1.00 57 COIL DATA 1 coil latching at 23 Standard type 2 coils latching Standard type Coil Resistance x(1 10%) Max. Voltage VDC Coil Code Nominal Voltage VDC Set / Reset Voltage VDC max. 2.25 90 8.4 003-M-L2 3 2.25 45 6 3.75 250 14 005-M-L2 5 3.75 125 10 6 4.5 360 17 006-M-L2 6 4.5 180 12 009-M-L1 9 6.75 810 25 009-M-L2 9 6.75 405 18 012-M-L1 12 9.0 1440 34 012-M-L2 12 9.0 720 24 015-M-L1 15 11.25 2220 42 015-M-L2 15 11.25 1125 30 024-M-L1 24 18.0 4000 56 024-M-L2 24 18.0 2040 48 Coil Code Nominal Voltage VDC Set / Reset Voltage VDC max. 003-M-L1 3 005-M-L1 5 006-M-L1 1 coil latching 2 coils latching Sensitive type Coil Resistance x(1 10%) Max. Voltage VDC Sensitive type Coil Resistance x(1 10%) Max. Voltage VDC Coil Code Nominal Voltage VDC Set / Reset Voltage VDC max. Coil Resistance x(1 10%) Max. Voltage VDC 2.4 60 6.9 003-S-L2 3 2.4 60 6.9 4.0 330 16 005-S-L2 5 4.0 167 11.5 6 4.8 480 19 006-S-L2 6 4.8 240 13.8 009-S-L1 9 7.2 1080 29 009-S-L2 9 7.2 540 20.8 012-S-L1 12 9.6 1920 39 012-S-L2 12 9.6 960 27.7 015-S-L1 15 12.0 3000 43 015-S-L2 15 12.0 1500 34.6 024-S-L1 24 19.2 7680 78 024-S-L2 24 19.2 3840 55.4 Coil Code Nominal Voltage VDC Set / Reset Voltage VDC max. 003-S-L1 3 005-S-L1 5 006-S-L1 Notes: 1) When user's requirements can't be found in the above table, special order allowed. 2) In case 5V of transistor drive circuit, it is recommended to use 4.5V type relay, and 3V to use 2.4V type relay. TYPICAL CONTACT LIFE EXPECTANCY SAFETY APPROVAL RATINGS 0.5A 60VDC Electrical endurance Voltage Power Resistive Load Inductive Load (For AC coso=0.7) 50mVDC 50W 5 x 107 OPS 5 x 107 OPS 30VDC 20W 3 x 106 OPS 1 x 106 OPS 30VDC 30W 6 1 x 10 5 OPS 5 OPS 4 OPS 3 x 10 30VDC 60W 1 x 10 60VDC 20W 3 x 106 OPS -- 60VDC 30W 5 x 105 OPS -- 60VDC 60W 1 x 105 OPS -- 30VAC 40VA 3 x 106 OPS 1 x 106 OPS 30VAC 80VA 1 x 106 OPS 3 x 105 OPS 30VAC 120VA 1 x 105 OPS 1.5 x 104 OPS 60VAC 40VA 3 x 106 OPS 1 x 106 OPS 60VAC 80VA 1 x 106 OPS 3 x 105 OPS 1.5 x 10 60VAC 120VA 1 x 10 OPS 1.5 x 104 OPS 125VAC 40VA 3 x 106 OPS 1 x 106 OPS 125VAC 80VA 1 x 106 OPS 3 x 105 OPS 125VAC 58 125VA 5 OPS 5 1 x 10 OPS 1.5 x 104 OPS AgPd/AgPd+Gold plated AgPd/Ag+Gold plated 2A 30VDC 1A 125VAC 2A 125VAC UL/CUL AgPd/Ag+Gold plated 3A 40VDC(40 C) Ag+Gold plated/ Ag+Gold plated 3A 30VDC(70 C) o 2A 30VDC o 1A 125VAC 2A 125VAC TUV AgPd/AgPd+Gold plated 2A 30VDC(70 C) AgPd/Ag+Gold plated 3A 30VDC(70 C) Ag+Gold plated o o 1A 125VAC(70 C) o Notes: 1) All values unspecified are at room temperature. 2) Only typical loads are listed above. Other load specifications can be available upon request. ORDERING INFORMATION H FD 2 / 0 12 -S - L2 -A (XXX) Type Coil voltage 3, 5, 6, 9, 12, 15, 24, 48VDC 1) Coil power M: Standard Sort L1: 1 coil latching L2: 2 coils latching Nil: Single side stable Contact material A: AgPd/AgPd+Gold plated D: Ag+Gold plated/Ag+Gold plated Nil: AgPd/Ag+Gold plated 2) Special code3) XXX: Customer special requirement S: Sensitive Nil: Standard Notes: 1) 48VDC coil voltage is only for single side stable & standard type. 2)XXX1/XXX2 : XXX1 stands for movable contact material, XXX2 stands for stationary contact material, for example, "A" means that the movable contact material is AgPd,stationary contact material AgPd+Gold plated. 3) The customer special requirement express as special code after evaluating by Hongfa. 4) Standard tube packing length is 527mm. Any special requirement needed, please contact us for more details. 5) For products that should meet the explosion-proof requirements of "IEC 60079 series",please note [Ex] after the specification while placing orders.Not all products have explosion-proof certification,so please contact us if necessary, in order to select the suitable products. OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT Outline Dimensions PCB Layout Wiring Diagram (Bottom view) (Bottom view) Single side stable Unit: mm or 1 coil latching 20.2 10.2 8x O1 1 4 6 2.54 8 2.54 16 1.2 2xO0.4 13 11 9 Matching 16 pin IC socket Orientation mark 6-0.5x0.25 For latching, diagram shows the "reset" position Energize terminals 1 and 16 to "set" Reverse energize terminals 1 and 16 to "reset" 20.2 10.2 2 coils latching 10x O1 1 2 4 6 2.54 8 2.54 1.2 16 4xO0.4 6-0.5x0.25 15 13 11 9 Orientation mark Matching 16 pin IC socket Diagram shows the "reset" position Energize terminals 1 and 16 to "set" Energize terminals 2 and 15 to "reset" Remark: 1) In case of no tolerance shown in outline dimension: outline dimension 1mm, tolerance should be 0.2mm; outline dimension 1mm and 5mm, tolerance should be 0.3mm; outline dimension 5mm, tolerance should be 0.4mm. 2) The tolerance without indicating for PCB layout is always 0.1mm. 3) The width of the gridding is 2.54mm. 59 CHARACTERISTIC CURVES MAXIMUM SWITCHING POWER COIL TEMPERATURE RISE +60 1000V AC Resistive Load +50 Full Load 100V +40 DC Resistive Load No Load +30 10V +20 10mV 0 10uA 100mA 1A 10A Contact Current Test conditions: o Resistive load, at 70 C, 1s on 9s off. 100 200 300 400 500 600 700 800 900 Coil Power (mW) Notice 1) This relay is highly sensitive polarized relay, if correct polarity is not applied to the coil terminals, the relay does not operate properly. 2) To avoid using relays under strong magnetic field which will change the parameters of relays such as pick-up voltage and drop-out voltage. 3) Relay is on the "reset" status when being released from stock, with the consideration of shock risen from transit and relay mounting, it should be changed to the "set" status when application(connecting to the power supply). Please reset the relay to "set" or "reset" status on request. 4) Energizing coil with rated voltage is basic for normal operation of a relay, please make sure the energized voltage to relay coil have reached the rated voltage. Regarding latching relay, in order to maintain the "set" or "reset" status, impulse width of the rated voltage applied to coil should be more than 5 times of "set" or "reset" time. 5) For 2 coil latching relay, do not energize voltage to "set" coil and "reset" coil simultaneously. 6) The relay may be damaged because of falling or when shocking conditions exceed the requirement. 7) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays on PCB. o 8) Regarding the plastic sealed relay, we should leave it cooling naturally untill below 40 C after welding, then clean it and deal with coating, o remarkably the temperature of solvents should also be controlled below 40 C.Please avoid cleaning the relay by ultrasonic, avoid using the solvents like gasoline, Freon, and so on, which would affect the configuration of relay or influence the environment. 9) About preferable condition of operation, storage and transportation, please refer to "Explanation to terminology and guidetines of relay". Disclaimer The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice. We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user's responsibility to determine which product should be used only. (c) Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved. 60