FEATURES BENEFIT
HOW TO ORDER
E
CLIPSE
S
ERIES
PRESSURE
TRANSDUCER
APPLICATIONS
HYDRAULIC/
PNEUMATIC CONTROLS
AIR
COMPRESSORS
ENERGY
MANAGEMENT
‘smart’ compressors,
refrigeration/chiller
control
PROCESS CONTROL
SYSTEMS
ENGINE CONTROLS
AND MONITORS
Voltage or current output Flexibility for the designer
15 PSIG through 7100 PSIS ranges Suitable for many applications
CE versions available Ready for Europe
Weather proof type connector High reliability in tough environments
Reverse polarity protection Not damaged by reversed excitation
Low excitation voltage Suitable for ORV or marine use
IP65 sealed steel case Complete environmental protection for electronics
MODEL ECLIPSE • OEM PRESSURE TRANSDUCER
The Eclipse is designed for OEM's needing a
reliable pressure transmitter for industrial or other
heavy duty applications. The Eclipse's combination
of rugged packaging, internal signal amplification
and price make it ideal for many applications.
The pressure media is contained by a brazed
assembly of stainless steel. There are no hidden
O-rings or elastomers containing the media. A plated
steel case protects the internal electronics.
It is available with either a 0.5 to 4.5 volt or 4 to
20 mA output. The 4 to 20 mA output is useful for
applications where electrical noise may be a concern.
Units with the Hirschmann connector are CE
approved.
Note: Not all combinations are available. Minimum quantity orders apply. Contact the factory for more details.
Model
Range
Unit
Output
Termination
Pressure Port
EC 100 P S 1 P G
P = PSI
C = 0.5-4.5 VDC
G = 4-20 mA
P = Packard
H = Hirschmann
1 = 1/8 NPT
6 = G 1/4 BSP
001 010 050
002 015 100
004 020 200
007 035 350
500
BAR
015 200 02K
025 300 03K
050 500 05K
100 01K 07K
PSI
Reference
G = Gage (PSIG)
S = Sealed (PSIS)
P = BAR
www.honeywell.com/sensing/products/di
E
CLIPSE
S
ERIES
PRESSURE
TRANSDUCER
TECHNICAL SPECIFICATIONS
Sensing and Control
Honeywell
100 Discovery W ay
Acton, MA 01720 USA
T el: (877) 384-1300; Fax: (978) 263-0630
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local
sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell
will repair or replace without charge those items it finds defective. The foregoing is Buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of merchantability and fitness for a particular purpose.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer
to determine the suitability of the product in the application.
Item # 1096500 M.G. 3/01
DIMENSIONS
xx.xx = inches
(xx.x) = mm
RANGE
0-15, 25, 50 psig
0-100, 200, 300, 500, 1000, 2000, 3000, 5000, 7180 psis
0-1, 2, 4, 7 bar g
0-10, 15, 20, 35, 50, 100, 200, 350, 500 bar s
PHYSICAL
Proof Pressure 1.5 x rated range without damage
Burst Pressure 5 x rated range without bursting
Material in Contact 300 series SS,
With Media braze compound
Shock 50 g’s peak (5 milliseconds)
Vibration Meets MIL-STD 810B, Figure 514-4,
Curve AK, Time Schedule II
Random Vibration Test (Overall g rms = 20.7 minimum)
ELECTRICAL Voltage out Current out
Span 4.00 V nominal 16 mA
(0.5 - 4.5 V) (4 - 20mA)
Zero output 0.5 V nominal 4 mA nominal
Excitation 5.0 Vdc ±0.25 Vdc 10 to 40 Vdc
@ 20 mA max (linear derating to 35 Vdc
from 25° to 100° C)
Reverse Polarity Protection Yes
Insulation Resistance 1000 MW @ 250 Vdc
Electrical Standard Packard Metri-Pack™.
Connection Requires Packard #12065287 mating
connector, not included.
Optional Hirschmann connector, mate included.
PERFORMANCE
Accuracy ±1% of F.S.O. from best fit straight line.
Including effects of non-linearity,
hysteresis and non-repeatability
Compensated 30° to 180°F (-1° to 82°C)
Temperature Range
Operating and Storage -40° to 221°F (-40° to 105°C)
Temperature Range
Total Error ±4% of full scale. Includes the effects
of zero output error, calibration error, temperature,
non-linearity, hysteresis, and repeatability.
NOTE: All specifications are measured at 25
°
C and rated excitation unless otherwise
specified.
egatloVtnerruC
1niPCNCN
2niPtuptuOlangiSCN
3niPnommoC noitaticxE- )nruteR(
4niPnoitaticxE+noitaticxE+
psi: 1/8-27 NPT, 5/8 (15.9) Hex
bar: G 1/4 (16) Hex
(23)
7/8" 1 1/2" 1.0 MAX
1"
(25)
(38)
ca
b
Ground
Signal
Supply
voltage
(25)
2
4
3
1
(38) 1.0 MAX
1"
(25)
psi: 1/8-27 NPT, 5/8 (15.9) Hex
bar: G 1/4 (16) Hex
.55
(13)
3.0 MAX
1 1/2"
23
4
Ground
Supply
volta
g
e
Signal
(25)
(76)
egatloVtnerruC
anoitaticxE+noitaticxE+
btuptuO noitaticxE- )nruteR(
cnommoCCN
PACKARD CONNECTOR PINS
HIRSCHMANN CONNECTOR PINS