MINI-PS-100-240AC/24DC/C2LPS
Order No.: 2866336
http://eshop.phoenixcontact.co.uk/phoenix/treeViewClick.do?UID=2866336
DIN rail power supply unit, primary-switched mode, slim design,
output: 24 V DC / 100 W, NEC Class 2 approval.
Commercial data
EAN
4 017918 975043
Pack 1
Customs tariff 85044081
Country of Origin CN
Catalog page information Page 597 (IF-2011)
Product notes
WEEE/RoHS-compliant since:
17/01/2008
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation at http://
www.download.phoenixcontact.com.
The General Terms and Conditions
of Use apply to Internet downloads.
Technical data
Input data
Nominal input voltage 100 V AC ... 240 V AC
AC input voltage range 85 V AC ... 264 V AC
DC input voltage range 90 V DC ... 350 V DC
AC frequency range 45 Hz ... 65 Hz
MINI-PS-100-240AC/24DC/C2LPS Order No.: 2866336
http://eshop.phoenixcontact.co.uk/phoenix/treeViewClick.do?UID=2866336
PHOENIX CONTACT Ltd Page 2 / 6
http://www.phoenixcontact.co.uk 20-Jan-2012
DC frequency range 0 Hz
Current consumption Approx. 1.3 A (120 V AC)
0.8 A (230 V AC)
Approx. 1.3 A (90 V DC)
Approx. 0.4 A (350 V DC)
Inrush surge current < 15 A (typical)
Power failure bypass > 20 ms (120 V AC)
> 100 ms (230 V AC)
Input fuse 3.15 A (slow-blow, internal)
Permissible backup fuse B6
B10
B16
Output data
Nominal output voltage 24 V DC ±1%
Setting range of the output voltage 22.5 V DC ... 26 V DC (> 24 V constant capacity)
Output current 3.8 A (-25 °C ... 60 °C)
Derating 60 °C ... 70 °C (2.5%/K)
Connection in parallel Yes, for redundancy and increased capacity
Connection in series Yes
Residual ripple < 40 mVPP (20 MHz)
Peak switching voltages idling < 100 mVPP (20 MHz)
Maximum power dissipation idling 2.5 W
Power loss nominal load max. 12 W
General data
Width 67.5 mm
Height 99 mm
Depth 107 mm
Net weight 0.4 kg
Operating voltage display Green LED
Efficiency > 88 % (for 230 V AC and nominal values)
Insulation voltage input/output 3 kV (routine test)
3 kV (type test)
Degree of protection IP20
Protection class II (in an enclosed control cabinet)
MINI-PS-100-240AC/24DC/C2LPS Order No.: 2866336
http://eshop.phoenixcontact.co.uk/phoenix/treeViewClick.do?UID=2866336
PHOENIX CONTACT Ltd Page 3 / 6
http://www.phoenixcontact.co.uk 20-Jan-2012
MTBF (IEC 61709, SN 29500) > 500000 h
Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C derating)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, no condensation)
Mounting position horizontal DIN rail NS 35, EN 60715
Assembly instructions Can be aligned: Horizontally 0 mm, vertically 50 mm
Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC
Noise emission EN 50081-2
Noise immunity EN 61000-6-2:2005
Low Voltage Directive Conformance with LV directive 2006/95/EC
Standard - Safety of transformers EN 61558-2-17
Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in
electrical power installations and their assembly
into electrical power installations
EN 50178/VDE 0160 (PELV)
Standard - Safe isolation DIN VDE 0100-410
DIN VDE 0106-1010
Standard – Limitation of mains harmonic currents EN 61000-3-2
Standard – Equipment safety GS (tested safety)
UL approvals UL/C-UL listed UL 508
UL/C-UL Recognized UL 60950
UL/C-UL Listed UL 1604 Class I, Division 2, Groups A, B, C, D
NEC Class 2 as per UL 1310
Surge voltage category III
Connection data, input
Connection method Pluggable screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section stranded min. 0.2 mm²
Conductor cross section stranded max. 2.5 mm²
Conductor cross section AWG/kcmil min. 24
Conductor cross section AWG/kcmil max 12
Stripping length 7 mm
Screw thread M3
MINI-PS-100-240AC/24DC/C2LPS Order No.: 2866336
http://eshop.phoenixcontact.co.uk/phoenix/treeViewClick.do?UID=2866336
PHOENIX CONTACT Ltd Page 4 / 6
http://www.phoenixcontact.co.uk 20-Jan-2012
Connection data, output
Connection method Pluggable screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section stranded min. 0.2 mm²
Conductor cross section stranded max. 2.5 mm²
Conductor cross section AWG/kcmil min. 24
Conductor cross section AWG/kcmil max 12
Stripping length 7 mm
Signaling
Output name DC OK active
Output description UOUT > 21.5 V: High signal
Maximum switching voltage ≤ 24 V
Output voltage + 24 V (signal)
Continuous load current ≤ 20 mA
Status display "DC OK" LED green
Note on status display UOUT > 21.5 V: LED lights up
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section stranded min. 0.2 mm²
Conductor cross section stranded max. 2.5 mm²
Conductor cross section AWG/kcmil min. 24
Conductor cross section AWG/kcmil max 12
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm
Screw thread M3
Certificates
Certification CUL, CUL Listed, UL, UL Listed
Certification Ex: CUL-EX LIS, UL-EX LIS
MINI-PS-100-240AC/24DC/C2LPS Order No.: 2866336
http://eshop.phoenixcontact.co.uk/phoenix/treeViewClick.do?UID=2866336
PHOENIX CONTACT Ltd Page 5 / 6
http://www.phoenixcontact.co.uk 20-Jan-2012
Drawings
Block diagram
Diagram
Output characteristic curve
MINI-PS-100-240AC/24DC/C2LPS Order No.: 2866336
http://eshop.phoenixcontact.co.uk/phoenix/treeViewClick.do?UID=2866336
PHOENIX CONTACT Ltd Page 6 / 6
http://www.phoenixcontact.co.uk 20-Jan-2012
Address
PHOENIX CONTACT Ltd
Halesfield 13
Telford / Shropshire / TF7 4PG,England
Phone 01952 681 700
Fax 01952 681 799
http://www.phoenixcontact.co.uk
Phoenix Contact Ltd.
Technical modifications reserved;