Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
MECHANICAL DIMENSIONS (Unit:mm)
CASE A
CASE B
CASE C
MECHANICAL DIMENSIONS
FEATURES
The HGN-375(A,B, C) series offers filters in three different
package styles - Flange mount (sides), Flange mount (top/
bottom), & snap-in type. This cost effective series offers more
component options with better performance in curbing
common and differential mode noise. These filters are
equipped with IEC connector, fuse holder for one or two 5 x
20 mm fuses, 2 pole on/off switch and fully enclosed metal
housing.
These filters are also available for Medical equipment with
low leakage current and have been designed to bring various
medical equipments into compliance with EN55011 and FCC
Part 15J, Class B conducted emissions limits.
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
TECHNICAL DATA
Rated Voltage: 125/250VAC
Rated Current: 1A, 2A, 3A, 4A, 6A, 10A
Power Line Frequency: 50/60Hz
Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.5mA, max
@ 250VAC 50Hz: 1.0mA, max
@ 125VAC 60Hz: 2µA*, max
@ 250VAC 50Hz: 5µA*, max
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
Temperature Range: -25C to +85C
* Medical application
(Unit:mm)
FUSED WITH ON/OFF SWITCH, IEC 60320 POWER INLET
SOCKET WITH FUSE/S (5X20MM)
HGN-375(A, B, C)
29 6.3 TYP.
72.0
60.8
R2.5 TYP.
RECOMMENDED PANEL CUTOUT
(MOUNT FROM FRONT)
29.3
2x 3.5
+0.5
+0.5
+0.1
59.8
48.7 (3.5)
82 72
2x 3.3
Use only with a 250V fuse
Employer uniquement avec
un fusible de 250V
29 6.3 TYP.
R2.5 TYP.
29.3
61.4
+0.5
+0.3
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
THICKNESS OF PANEL IS FROM
1.00mm to 1.6mm
59.8
(56.2)
48.7 (3.5)
(61.3)
28
65
32
59.5
Use only with a 250V fuse
Employer uniquement avec
un fusible de 250V
60.0
49.37
3.5
55.04
60.71
28.5
6.30 TYP.
4x R0.5
2x M3
40.0+
--0.2
61.5
29.5
81
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com
HGN-375(A, B, C) Series Example & Ordering Code
HGN-375
CURRENT RATING (A): = 01
= 02
= 03
= 04
= 06
= 10**
TERMINAL: = Q
= S
= W
OPTIONS:
= 0
= 5
= 6
= 7
= 8
= 9
QUICK CONNECT
SOLDER
WIRE
- -
NO BLEEDER RESISTOR & NO GROUND CHOKE
BLEEDER RESISTOR (1/4 W, 1M)
BLEEDER RESISTOR (1/2 W, 1M)
BLEEDER RESISTOR (1/4 W, 1M) & GROUND CHOKE
BLEEDER RESISTOR (1/2 W, 1M) & GROUND CHOKE
GROUND CHOKE (400µH)
COMPONENT LOCATIONS: = 1
= 2
= 1M
= 2M
STANDARD TYPE
STANDARD TYPE; ADDITIONAL C(X) BEHIND L
WITHOUT C(Y); C(X) ONLY
WITHOUT C(Y); ADDITIONAL C(X) BEHIND L
6.3/0.25
4.0/0.187
UL 1015, 18AWG
STRANDED, 4”
01 Q151SCHEMATICS
MEDICAL
SCHEMATICS
ATTENUATION CODE TABLE:
Capacitor C(x) 1A (mH) 2A (mH) 3A (mH) 4A (mH) 6A (mH) 10A (mH)
0.1µF 6.5 3.8 2.5 1.6 0.8 0.2
0.1µF 3.7 2.7 1.8 1.3 0.8 0.3
0.22µF 7.5 5.5 2.5 2.0 0.8 0.4
0.22µF 10.5 6.5 2.5 2.7 1.05 0.4
Medical applications, select Attenuation code with corresponding component values from the table.
Non-Medical applications, select Attenuation code with corresponding component values from the table.
Capacitor C(x) Capacitor C(y) 1A (mH) 2A (mH) 3A (mH) 4A (mH) 6A (mH) 10A (mH)
0.1µF 2200pF 6.5 3.8 2.5 1.6 0.8 0.2
0.1µF 3300pF 3.7 2.7 1.8 1.3 0.8 0.3
0.22µF 2200pF 7.5 5.5 2.5 2.0 0.8 0.4
0.22µF 3300pF 10.5 6.5 2.5 2.7 1.05 0.4
= A
= B
= C
= D
1
2
1M
2M
= M1
= M2
= M3
= M4
8.0
3.0-3.6L
6.6
2.0-3.0L
A
FUSE & SWITCH
OPTIONS: = 1
= 2
= 3
= 4
= 5
= 6
BLACK, NON-ILLUMINATED SWITCH, 1 FUSE (5X20MM)
BLACK, NON-ILLUMINATED SWITCH, 2 FUSE (5X20MM)
RED ILLUMINATED SWITCH, 1 FUSE (5X20MM)
RED ILLUMINATED SWITCH, 2 FUSE (5X20MM)
GREEN ILLUMINATED SWITCH, 1 FUSE (5X20MM)
GREEN ILLUMINATED SWITCH, 2 FUSE (5X20MM)
CX
G
LOAD
L mH
L mH
Cy
L
L'
N'
G'
Lg
Cy
R
FUSE
L
N
LINE
FUSE
CX
G
LOAD
L mH
L mH
L
L'
N'
Lg
R
FUSE
L
N
LINE
FUSE G'
CX
GL mH
L mH
L
R
FUSE
L
N
LINE
FUSE
LOAD
L'
N'
G'
Cy
Cy
CX
CX
L mH
L mH
L
R
FUSE
L
N
LINE
FUSE
LOAD
L'
N'
CX
G'
G
Contact PDI for attenuation numbers
**UL and cUL approved to 10A; VDE approved
to 6.3A
Not available for Schematic 2 & 2M
OPTIONS:
A
CASE CODE:
= A
= B
= C
FLANGE MOUNT, SIDES
FLANGE MOUNT, TOP/BOTTOM
SNAP-IN
82
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com
HGN-375(A, B, C) Series Attenuation Tables
Comm. Mode(L-G) in MHz Diff. mode(L-L) in MHz
.15 .5 1 5 10 30 .15 .5 1 5 10 30
35 38 40 32 20 24 8 25 37 71 62 12
30 34 36 31 18 22 8 23 34 68 64 14
27 34 36 29 23 22 8 19 27 58 65 15
22 27 28 29 26 13 8 18 26 43 51 31
20 25 26 27 25 32 8 18 25 29 38 31
9 13 19 19 17 13 7 17 23 39 47 27
28 35 37 28 22 24 8 20 29 61 48 15
25 33 58 51 56 41 8 20 30 57 47 13
11 16 18 18 16 12 8 18 24 47 36 24
19 23 24 27 27 21 8 19 27 47 45 30
11 16 18 18 16 12 8 18 24 47 36 24
37 45 41 22 30 19 17 35 47 57 44 34
31 35 37 31 37 15 16 34 48 57 54 18
25 29 30 26 19 12 15 28 38 52 47 19
24 27 28 30 27 22 14 26 37 44 45 23
19 24 25 25 23 17 15 26 33 50 44 27
14 16 18 20 20 15 14 26 34 37 35 26
17 36 49 65 47 23 38 42 42 25 43 16
35 38 40 33 20 24 16 33 45 66 53 14
26 30 31 27 19 14 14 27 37 60 46 20
19 24 25 25 24 17 14 25 33 45 42 29
Attenuation
Code
A
B
C
D
Attenuation
Code
M1
M2
M3
M4
Current
Rating
1A
2A
3A
4A
6A
10A
1A
2A
3A
4A
10A
1A
2A
3A
4A
6A
10A
1A
2A
4A
6A
Current
Rating
1A
2A
3A
4A
6A
10A
1A
2A
3A
4A
6A
10A
1A
2A
3A
4A
6A
10A
1A
2A
3A
4A
6A
10A
Comm. Mode(L-G) in MHz Diff. mode(L-L) in MHz
.15 .5 1 5 10 30 .15 .5 1 5 10 30
34 38 40 32 26 11 8 25 37 71 62 12
29 32 55 48 49 51 8 23 34 68 64 14
28 36 39 45 48 39 8 19 27 58 65 15
22 27 30 48 54 47 8 19 28 66 72 34
18 24 28 44 50 47 8 18 26 43 51 31
8 14 18 33 41 39 8 18 25 29 38 31
29 33 47 53 57 41 8 23 35 73 58 14
28 37 44 52 56 41 8 19 27 74 59 17
25 33 46 53 57 44 8 19 29 63 62 13
19 24 27 43 53 38 8 18 25 57 60 32
19 29 36 49 55 46 8 18 23 50 54 24
11 19 24 41 53 36 8 18 24 51 46 25
37 44 52 47 48 49 17 35 48 65 57 36
31 34 48 50 52 50 16 33 48 63 62 17
25 30 34 45 47 39 15 27 37 59 57 21
27 28 33 50 56 48 14 26 35 51 57 24
19 25 30 43 51 44 15 25 32 60 59 29
14 19 24 41 54 42 14 25 33 45 56 31
36 54 53 45 32 40 26 60 84 49 36 17
35 42 50 51 57 59 15 32 45 70 71 14
25 31 37 48 52 37 15 27 37 60 56 23
26 32 41 49 51 45 14 26 36 64 57 23
19 27 32 47 56 45 14 25 31 56 59 31
14 18 22 38 49 41 17 42 64 58 49 29
This table applies to schematic 1 only.
Visit our website or contact PDI for other schematic attenuation numbers.
This table applies to schematic 1M only.
Visit our website or contact PDI for other schematic attenuation numbers.
Medical ApplicationsNon-Medical Applications
Insertion loss in dB (50 Ohm circuit) Insertion loss in dB (50 Ohm circuit)
83
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •